34 resultados para thoracolumbar


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vertebral compression fracture is a common medical problem in osteoporotic individuals. The quantitative computed tomography (QCT)-based finite element (FE) method may be used to predict vertebral strength in vivo, but needs to be validated with experimental tests. The aim of this study was to validate a nonlinear anatomy specific QCT-based FE model by using a novel testing setup. Thirty-seven human thoracolumbar vertebral bone slices were prepared by removing cortical endplates and posterior elements. The slices were scanned with QCT and the volumetric bone mineral density (vBMD) was computed with the standard clinical approach. A novel experimental setup was designed to induce a realistic failure in the vertebral slices in vitro. Rotation of the loading plate was allowed by means of a ball joint. To minimize device compliance, the specimen deformation was measured directly on the loading plate with three sensors. A nonlinear FE model was generated from the calibrated QCT images and computed vertebral stiffness and strength were compared to those measured during the experiments. In agreement with clinical observations, most of the vertebrae underwent an anterior wedge-shape fracture. As expected, the FE method predicted both stiffness and strength better than vBMD (R2 improved from 0.27 to 0.49 and from 0.34 to 0.79, respectively). Despite the lack of fitting parameters, the linear regression of the FE prediction for strength was close to the 1:1 relation (slope and intercept close to one (0.86 kN) and to zero (0.72 kN), respectively). In conclusion, a nonlinear FE model was successfully validated through a novel experimental technique for generating wedge-shape fractures in human thoracolumbar vertebrae.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To compare the accuracy of radiography and computed tomography (CT) in predicting implant position in relation to the vertebral canal in the cervical and thoracolumbar vertebral column. STUDY DESIGN In vitro imaging and anatomic study. ANIMALS Medium-sized canine cadaver vertebral columns (n=12). METHODS Steinmann pins were inserted into cervical and thoracolumbar vertebrae based on established landmarks but without predetermination of vertebral canal violation. Radiographs and CT images were obtained and evaluated by 6 individuals. A random subset of pins was evaluated for ability to distinguish left from right pins on radiographs. The ability to correctly identify vertebral canal penetration for all pins was assessed both on radiographs and CT. Spines were then anatomically prepared and visual examination of pin penetration into the canal served as the gold standard. RESULTS Left/right accuracy was 93.1%. Overall sensitivity of radiographs and CT to detect vertebral canal penetration by an implant were significantly different and estimated as 50.7% and 93.4%, respectively (P<.0001). Sensitivity was significantly higher for complete versus partial penetration and for radiologists compared with nonradiologists for both imaging modalities. Overall specificity of radiographs and CT to detect vertebral canal penetration was 82.9% and 86.4%, respectively (P=.049). CONCLUSIONS CT was superior to radiographic assessment and is the recommended imaging modality to assess penetration into the vertebral canal. CLINICAL RELEVANCE CT is significantly more accurate in identifying vertebral canal violation by Steinmann pins and should be performed postoperatively to assess implant position.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objectives of this study were to describe a new spinal cord injury scale for dogs, evaluate repeatability through determining inter-rater variability of scores, compare these scores to another established system (a modified Frankel scale), and determine if the modified Frankel scale and the newly developed scale were useful as prognostic indicators for return to ambulation. A group of client-owned dogs with spinal cord injury were examined by 2 independent observers who applied the new Texas Spinal Cord Injury Score (TSCIS) and a modified Frankel scale that has been used previously. The newly developed scale was designed to describe gait, postural reactions and nociception in each limb. Weighted kappa statistics were utilized to determine inter-rater variability for the modified Frankel scale and individual components of the TSCIS. Comparisons were made between raters for the overall TSCIS score and between scales using Spearman's rho. An additional group of dogs with surgically treated thoracolumbar disk herniation was enrolled to look at correlation of both scores with spinal cord signal characteristics on magnetic resonance imaging (MRI) and ambulatory outcome at discharge. The actual agreement between raters for the modified Frankel scale was 88%, with a weighted kappa value of 0.93. The TSCIS had weighted kappa scores for gait, proprioceptive positioning and nociception components that ranged from 0.72 to 0.94. Correlation between raters for the overall TSCIS score was Spearman's rho=0.99 (P<0.001). Comparison of the overall TSCIS score to the modified Frankel score resulted in a Spearman's rho value of 0.90 (P<0.001). The modified Frankel score was weakly correlated with the length of hyperintensity of the spinal cord: L2 vertebral body length ratio on mid-sagittal T2-weighted MRI (Spearman's rho=-0.45, P=0.042) as was the overall TSCIS score (Spearman's rho=-0.47, P=0.037). There was also a significant difference in admitting modified Frankel scores (P=0.029) and admitting overall TSCIS scores (P=0.02) between dogs that were ambulatory at discharge and those that were not. Results from this study suggest that the TSCIS is an easy to administer scale for evaluating canine spinal cord injury based on the standard neurological exam and correlates well with a previously described modified Frankel scale.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To determine the success of medical management of presumptive cervical disk herniation in dogs and variables associated with treatment outcome. DESIGN Retrospective case series. ANIMALS Dogs (n=88) with presumptive cervical disk herniation. METHODS Dogs with presumptive cervical and thoracolumbar disk herniation were identified from medical records at 2 clinics and clients were mailed a questionnaire related to the success of therapy, clinical recurrence of signs, and quality of life (QOL) as interpreted by the owner. Signalment, duration and degree of neurologic dysfunction, and medication administration were determined from medical records. RESULTS Ninety-seven percent of dogs (84/87) with complete information were described as ambulatory at initial evaluation. Successful treatment was reported for 48.9% of dogs with 33% having recurrence of clinical signs and 18.1% having therapeutic failure. Bivariable logistic regression showed that non-steroidal anti-inflammatory drug (NSAID) administration was associated with success (P=.035; odds ratio [OR]=2.52). Duration of cage rest and glucocorticoid administration were not significantly associated with success or QOL. Dogs with less-severe neurologic dysfunction were more likely to have a successful outcome (OR=2.56), but this association was not significant (P=.051). CONCLUSIONS Medical management can lead to an acceptable outcome in many dogs with presumptive cervical disk herniation. Based on these data, NSAIDs should be considered as part of the therapeutic regimen. Cage rest duration and glucocorticoid administration do not appear to benefit these dogs, but this should be interpreted cautiously because of the retrospective data collection and use of client self-administered questionnaire follow-up. CLINICAL RELEVANCE These results provide insight into the success of medical management for presumptive cervical disk herniation in dogs and may allow for refinement of treatment protocols.