55 resultados para simultaneous shape and topology optimisation
Resumo:
The multi-target screening method described in this work allows the simultaneous detection and identification of 700 drugs and metabolites in biological fluids using a hybrid triple-quadrupole linear ion trap mass spectrometer in a single analytical run. After standardization of the method, the retention times of 700 compounds were determined and transitions for each compound were selected by a "scheduled" survey MRM scan, followed by an information-dependent acquisition using the sensitive enhanced product ion scan of a Q TRAP hybrid instrument. The identification of the compounds in the samples analyzed was accomplished by searching the tandem mass spectrometry (MS/MS) spectra against the library we developed, which contains electrospray ionization-MS/MS spectra of over 1,250 compounds. The multi-target screening method together with the library was included in a software program for routine screening and quantitation to achieve automated acquisition and library searching. With the help of this software application, the time for evaluation and interpretation of the results could be drastically reduced. This new multi-target screening method has been successfully applied for the analysis of postmortem and traffic offense samples as well as proficiency testing, and complements screening with immunoassays, gas chromatography-mass spectrometry, and liquid chromatography-diode-array detection. Other possible applications are analysis in clinical toxicology (for intoxication cases), in psychiatry (antidepressants and other psychoactive drugs), and in forensic toxicology (drugs and driving, workplace drug testing, oral fluid analysis, drug-facilitated sexual assault).
Resumo:
In humans, there are different types of cutaneous cold-sensitive afferents responsible for cold sensation and cold pain. Innocuous cold is primarily mediated by a population of slow A delta afferents, based on psychophysical and neurophysiological studies. Noxious cold (usually below 15 degrees C) is mediated, at least in part, by polymodal nociceptors. There is also a population of unmyelinated afferents responsive to innocuous low temperature, some of which also respond to heat, whose sensory function has not been completely defined. A paradoxical hot/burning evoked by cooling is unmasked by A-fibre block, and similar sensations are evoked by applying simultaneous cool and warm stimuli to adjacent skin areas. These unmyelinated fibres activated by innocuous cooling (and heating) may contribute to this hot/burning sensation, along with other thermoregulatory functions.
Resumo:
We report a case of an accidental death or potential suicide by revolver with subsequent injury of another person. A 44-year-old man shot himself in the head while manipulating his.38 caliber special revolver in the kitchen in the presence of his wife, standing approximately 1.5 m next to him. After passing through the husband's head, the lead round-nose bullet entered the region underneath his wife's left eye. When the bullet left the man's head, it retained the energy to penetrate the soft tissue at this distance, including the skin and thin bone plates like the orbital wall. Owing to the low energy of the projectile, the entry wound was of atypical in shape and without loss of tissue. Only a small line-resembling a cut-was externally visible. The man died in the hospital from his injuries; his wife suffered visual loss of her left eye.
Resumo:
In this paper we present a new population-based implant design methodology, which advances the state-of-the-art approaches by combining shape and bone quality information into the design strategy. The method may enhance the mechanical stability of the fixation and reduces the intra-operative in-plane bending which might impede the functionality of the locking mechanism. The computational method is presented for the case of mandibular locking fixation plates, where the mandibular angle and the bone quality at screw locations are taken into account. The method automatically derives the mandibular angle and the bone thickness and intensity values at the path of every screw from a set of computed tomography images. An optimization strategy is then used to optimize the two parameters of plate angle and screw position. The method was applied to two populations of different genders. Results for the new design are presented along with a comparison with a commercially available mandibular locking fixation plate (MODUS(®) TriLock(®) 2.0/2.3/2.5, Medartis AG, Basel, Switzerland). The proposed designs resulted in a statistically significant improvement in the available bone thickness when compared to the standard plate. There is a higher probability that the proposed implants cover areas of thicker cortical bone without compromising the bone mineral density around the screws. The obtained results allowed us to conclude that an angle and screw separation of 129° and 9 mm for females and 121° and 10 mm for males are more suitable designs than the commercially available 120° and 9 mm.
Resumo:
AIMS: To compare morphometric parameters and diagnostic performance of the new Stratus Optical Coherence Tomograph (OCT) Disc mode and the Heidelberg Retina Tomograph (HRT); to evaluate OCT's accuracy in determining optic nerve head (ONH) borders. METHODS: Controls and patients with ocular hypertension, glaucoma-like discs, and glaucoma were imaged with OCT Disc mode, HRT II, and colour disc photography (DISC-PHOT). In a separate session, automatically depicted ONH shape and size in OCT were compared with DISC-PHOT, and disc borders adjusted manually where required. In a masked fashion, all print-outs and photographs were studied and discs classified as normal, borderline, and abnormal. The Cohen kappa method was then applied to test for agreement of classification. Bland-Altman analysis was used for comparison of disc measures. RESULTS: In all, 49 eyes were evaluated. Automated disc margin recognition failed in 53%. Misplaced margin points were more frequently found in myopic eyes, but only 31/187 were located in an area of peripapillary atrophy. Agreement of OCT with photography-based diagnosis was excellent in normally looking ONHs, but moderate in discs with large cups, where HRT performed better. OCT values were consistently larger than HRT values for disc and cup area. Compared with HRT, small rim areas and volumes tended to be minimized by OCT, and larger ones to be magnified. CONCLUSIONS: Stratus OCT Disc protocol performed overall well in differentiating between normal and glaucomatous ONHs. However, failure of disc border recognition was frequently observed, making manual correction necessary. ONH measures cannot be directly compared between HRT and OCT.
Resumo:
Cell-based therapies and tissue engineering initiatives are gathering clinical momentum for next-generation treatment of tissue deficiencies. By using gravity-enforced self-assembly of monodispersed primary cells, we have produced adult and neonatal rat cardiomyocyte-based myocardial microtissues that could optionally be vascularized following coating with human umbilical vein endothelial cells (HUVECs). Within myocardial microtissues, individual cardiomyocytes showed native-like cell shape and structure, and established electrochemical coupling via intercalated disks. This resulted in the coordinated beating of microtissues, which was recorded by means of a multi-electrode complementary metal-oxide-semiconductor microchip. Myocardial microtissues (microm3 scale), coated with HUVECs and cast in a custom-shaped agarose mold, assembled to coherent macrotissues (mm3 scale), characterized by an extensive capillary network with typical vessel ultrastructures. Following implantation into chicken embryos, myocardial microtissues recruited the embryo's capillaries to functionally vascularize the rat-derived tissue implant. Similarly, transplantation of rat myocardial microtissues into the pericardium of adult rats resulted in time-dependent integration of myocardial microtissues and co-alignment of implanted and host cardiomyocytes within 7 days. Myocardial microtissues and custom-shaped macrotissues produced by cellular self-assembly exemplify the potential of artificial tissue implants for regenerative medicine.
Resumo:
OBJECTIVE: The purpose of our study was to determine if preoperative MRI can differentiate between occult ganglion and synovitis in the chronic painful wrist. CONCLUSION: MRI is accurate in preoperatively distinguishing between ganglion and synovitis in the setting of chronic dorsal wrist pain. Four main criteria were useful: margin, shape, internal structure, and enhancement after administration of contrast material, with shape and internal structure being most helpful.
Resumo:
Osteoarthritis is thought to be caused by a combination of intrinsic vulnerabilities of the joint, such as anatomic shape and alignment, and environmental factors, such as body weight, injury, and overuse. It has been postulated that much of osteoarthritis is due to anatomic deformities. Advances in surgical techniques such as the periacetabular osteotomy, safe surgical dislocation of the hip, and hip arthroscopy have provided us with effective and safe tools to correct these anatomical problems. The limiting factor in treatment outcome in many mechanically compromised hips is the degree of cartilage damage which has occurred prior to treatment. In this regard, the role of imaging, utilizing plain radiographs in conjunction with magnetic resonance imaging, is becoming vitally important for the detection of these anatomic deformities and pre-radiographic arthritis. In this article, we will outline the plain radiographic features of hip deformities that can cause instability or impingement. Additionally, we will illustrate the use of MRI imaging to detect subtle anatomic abnormalities, as well as the use of biochemical imaging techniques such as dGEMRIC to guide clinical decision making.
Resumo:
The tremendous application potential of nanosized materials stays in sharp contrast to a growing number of critical reports of their potential toxicity. Applications of in vitro methods to assess nanoparticles are severely limited through difficulties in exposing cells of the respiratory tract directly to airborne engineered nanoparticles. We present a completely new approach to expose lung cells to particles generated in situ by flame spray synthesis. Cerium oxide nanoparticles from a single run were produced and simultaneously exposed to the surface of cultured lung cells inside a glovebox. Separately collected samples were used to measure hydrodynamic particle size distribution, shape, and agglomerate morphology. Cell viability was not impaired by the conditions of the glovebox exposure. The tightness of the lung cell monolayer, the mean total lamellar body volume, and the generation of oxidative DNA damage revealed a dose-dependent cellular response to the airborne engineered nanoparticles. The direct combination of production and exposure allows studying particle toxicity in a simple and reproducible way under environmental conditions.
Resumo:
OBJECTIVE: The effects of mechanical deformation of intact cartilage tissue on chondrocyte biosynthesis in situ have been well documented, but the mechanotransduction pathways that regulate such phenomena have not been elucidated completely. The goal of this study was to examine the effects of tissue deformation on the morphology of a range of intracellular organelles which play a major role in cell biosynthesis and metabolism. DESIGN: Using chemical fixation, high pressure freezing, and electron microscopy, we imaged chondrocytes within mechanically compressed cartilage explants at high magnification and quantitatively and qualitatively assessed changes in organelle volume and shape caused by graded levels of loading. RESULTS: Compression of the tissue caused a concomitant reduction in the volume of the extracellular matrix (ECM), chondrocyte, nucleus, rough endoplasmic reticulum, and mitochondria. Interestingly, however, the Golgi apparatus was able to resist loss of intraorganelle water and retain a portion of its volume relative to the remainder of the cell. These combined results suggest that a balance between intracellular mechanical and osmotic gradients govern the changes in shape and volume of the organelles as the tissue is compressed. CONCLUSIONS: Our results lead to the interpretive hypothesis that organelle volume changes appear to be driven mainly by osmotic interactions while shape changes are mediated by structural factors, such as cytoskeletal interactions that may be linked to extracellular matrix deformations. The observed volume and shape changes of the chondrocyte organelles and the differential behavior between organelles during tissue compression provide evidence for an important mechanotransduction pathway linking translational and post-translational events (e.g., elongation and sulfation of glycosaminoglycans (GAGs) in the Golgi) to cell deformation.
Resumo:
OBJECTIVE: The paper aims to define the parameters available before surgery which could predict immediate facial nerve function after excision of a vestibular schwannoma (VS). METHODS: Ninety-nine patients with VS operated consecutively by a single surgeon using an identical surgical technique have been evaluated retrospectively. Data were collected regarding patients' sex, age at onset of symptoms and at surgery, initial symptoms, neurological status at presentation, early post-operative neurological status and complications. The main radiological parameters included in the study were tumour extension pattern, diameters, shape, and volume, as well as extent of bony changes of the internal auditory canal. RESULTS: As the tumour stage and volume increase, facial nerve function is worse after surgery (p < 0.001 and p < 0.05, respectively). Concomitantly, larger extra-meatal tumour diameters in three dimensions (sagittal, coronal and axial) led to worse function (p < 0.01). Anterior and/or caudal tumour extension (p = 0.001 and p = 0.004, respectively) had more significant correlation than posterior and/or cranial extension (p = 0.022 and p = 0.353, respectively). Polycyclic VS had the worst prognosis, followed by the tumours with oval shape. The extent of intra-meatal tumour growth does not correlate with immediate facial nerve outcome. The different angles, lengths and diameters of the internal auditory channel showed no significant correlation with facial nerve outcome. Patients with headache as an initial symptom and those with gait instability and/or pre-operative poor facial nerve function had significantly worse immediate facial nerve outcome. CONCLUSION: Our data suggests that the analysis of the radiological and neurological patient data prior to surgery could give reliable clues regarding the immediate post-operative facial nerve function.
Resumo:
Electronic absorption and fluorescence spectra based on transmission measurements of thin layers obtained from new perylene−zeolite L composites and new dye1,dye2−zeolite L sandwich composites, the latter acting as antenna systems, have been investigated and analyzed. The influence of extra- and intraparticle self-absorption on the spectral shape and fluorescence quantum yield is discussed in detail. Due to its intraparticle origin, self-absorption and re-emission can often not be avoided in organized systems such as dye−zeolite L composites where a high density of chromophores is a prerequisite for obtaining the desired photophysical properties. We show, however, that it can be avoided or at least minimized by preparing dye1,dye2−zeolite L sandwich composites where donors are present in a much larger amount than the acceptors because they act as antenna systems.
Resumo:
Short-echo-time magnetic resonance spectra of human brain contain broad contributions from macromolecules. As they are a priori of unknown shape and intensity, they pose a problem if one wants to quantitate the overlying spectral features from low-molecular-weight metabolites. On the other hand, the macromolecular contributions may provide relevant clinical information themselves, if properly evaluated. Several methods, based on T(1), T(2), or spectral shape, have previously been suggested to suppress or edit the macromolecule contributions. Here, a method is presented based on a series of saturation recovery scans and that allows for simultaneous recording of the macromolecular baseline and the fully relaxed metabolite spectrum. In comparison to an inversion recovery technique aimed at nulling signals from long-T(1) components, the saturation recovery method is less susceptible to T(1) differences inherent in signals from different metabolites or introduced by pathology. The saturation recovery method was used to quantitate the macromolecular baseline in white and/or gray matter locations of the human brain in 40 subjects. It was found that the content and composition of MR visible macromolecules depends on cerebral location, as well as the age of the investigated subject, while no gender dependence could be found.
Resumo:
In this paper, we show statistical analyses of several types of traffic sources in a 3G network, namely voice, video and data sources. For each traffic source type, measurements were collected in order to, on the one hand, gain better understanding of the statistical characteristics of the sources and, on the other hand, enable forecasting traffic behaviour in the network. The latter can be used to estimate service times and quality of service parameters. The probability density function, mean, variance, mean square deviation, skewness and kurtosis of the interarrival times are estimated by Wolfram Mathematica and Crystal Ball statistical tools. Based on evaluation of packet interarrival times, we show how the gamma distribution can be used in network simulations and in evaluation of available capacity in opportunistic systems. As a result, from our analyses, shape and scale parameters of gamma distribution are generated. Data can be applied also in dynamic network configuration in order to avoid potential network congestions or overflows. Copyright © 2013 John Wiley & Sons, Ltd.
Resumo:
Quantitative measures of polygon shapes and orientation are important elements of geospatial analysis. These kinds of measures are particularly valuable in the case of lakes, where shape and orientation patterns can help identifying the geomorphological agents behind lake formation and evolution. However, the lack of built-in tools in commercial geographic information system (GIS) software packages designed for this kind of analysis has meant that many researchers often must rely on tools and workarounds that are not always accurate. Here, an easy-to-use method to measure rectangularity R, ellipticity E, and orientation O is developed. In addition, a new rectangularity vs. ellipticity index, REi, is defined. Following a step-by-step process, it is shown how these measures and index can be easily calculated using a combination of GIS built-in functions. The identification of shapes and estimation of orientations performed by this method is applied to the case study of the geometric and oriented lakes of the Llanos de Moxos, in the Bolivian Amazon, where shape and orientation have been the two most important elements studied to infer possible formation mechanisms. It is shown that, thanks to these new indexes, shape and orientation patterns are unveiled, which would have been hard to identify otherwise.