37 resultados para short range order


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Astronomical Institute of the University of Bern (AIUB) is conducting several search campaigns for orbital debris. The debris objects are discovered during systematic survey observations. In general only a short observation arc, or tracklet, is available for most of these objects. From this discovery tracklet a first orbit determination is computed in order to be able to find the object again in subsequent follow-up observations. The additional observations are used in the orbit improvement process to obtain accurate orbits to be included in a catalogue. In this paper, the accuracy of the initial orbit determination is analyzed. This depends on a number of factors: tracklet length, number of observations, type of orbit, astrometric error, and observation geometry. The latter is characterized by both the position of the object along its orbit and the location of the observing station. Different positions involve different distances from the target object and a different observing angle with respect to its orbital plane and trajectory. The present analysis aims at optimizing the geometry of the discovery observation is depending on the considered orbit.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes a technique to significantly improve upon the mass peak shape and mass resolution of spaceborne quadrupolemass spectrometers (QMSs) through higher order auxiliary excitation of the quadrupole field. Using a novel multiresonant tank circuit, additional frequency components can be used to drive modulating voltages on the quadrupole rods in a practical manner, suitable for both improved commercial applications and spaceflight instruments. Auxiliary excitation at frequencies near twice that of the fundamental quadrupole RF frequency provides the advantages of previously studied parametric excitation techniques, but with the added benefit of increased sensed excitation amplitude dynamic range and the ability to operate voltage scan lines through the center of upper stability islands. Using a field programmable gate array, the amplitudes and frequencies of all QMS signals are digitally generated and managed, providing a robust and stable voltage control system. These techniques are experimentally verified through an interface with a commercial Pfeiffer QMG422 quadrupole rod system. When operating through the center of a stability island formed from higher order auxiliary excitation, approximately 50% and 400% improvements in 1% mass resolution and peak stability were measured, respectively, when compared with traditional QMS operation. Although tested with a circular rod system, the presented techniques have the potential to improve the performance of both circular and hyperbolic rod geometry QMS sensors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The electrochemical reduction of CO2 has been extensively studied over the past decades. Nevertheless, this topic has been tackled so far only by using a very fundamental approach and mostly by trying to improve kinetics and selectivities toward specific products in half-cell configurations and liquid-based electrolytes. The main drawback of this approach is that, due to the low solubility of CO2 in water, the maximum CO2 reduction current which could be drawn falls in the range of 0.01–0.02 A cm–2. This is at least an order of magnitude lower current density than the requirement to make CO2-electrolysis a technically and economically feasible option for transformation of CO2 into chemical feedstock or fuel thereby closing the CO2 cycle. This work attempts to give a short overview on the status of electrochemical CO2 reduction with respect to challenges at the electrolysis cell as well as at the catalyst level. We will critically discuss possible pathways to increase both operating current density and conversion efficiency in order to close the gap with established energy conversion technologies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cancer is one of the most severe and widespread diseases and an ideal treatment has not yet been found. In the last decades, cisplatinum was commonly applied in cancer therapy with very good results. However, serious side effects and resistant tumors necessitated the development of new antineoplastic agents, such as metallocenes dihalides. These are metal-based compounds exhibiting two cyclopentadienyl ligands and a cis-dihalide motif. They resemble the cis-chloro configuration of cisplatinum, which propounds a similar mode of action. Metallocenes comprising one of the transition metals titanium, molybdenum, vanadium, niobium, and zirconium as the metal center have been shown to be effective against several cancer cell lines. Evidence for the accumulation of metallocenes in the nucleus implied that DNA is one of the major targets. Although several studies reported adduct formation of metallocenes with nuclear DNA, as yet substantial information about the general binding pattern and the binding to higher-order structures is lacking. Mass spectrometry can fill this gap as it constitutes a powerful technique to investigate the formation of organometallic adducts. Presented data demonstrate that the two agents titanocene dichloride and molybdenocene dichloride bind to single-stranded DNA and RNA. Distinct fragment ions formed upon collision-induced dissociation help to unravel preferential binding sites within the oligonucleotides. Moreover, adducts with duplexes and quadruplexes shed light on the molecular mechanism of action.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study presents static measurements of the Ca isotopic composition of standard reference materials SRM 915 a/b on a Triton Plus™ thermal ionization mass spectrometer with a specially developed Faraday cup array allowing simultaneous measurement of 40Ca and 48Ca. The total amount of Ca in all analyses was kept < 1 µg. With this setup the measurement uncertainties were 0.06 ‰ for 40Ca/44Ca and 0.12 ‰ for 48Ca/40Ca. Measuring all isotopes simultaneously better allows to test the internal consistency of different Ca isotope abundances reported in the literature. The exponential law was observed to correct incompletely instrumental mass fractionation. An improved fractionation correction based on the exponential law is proposed. It changes the 40Ca/44Ca ratio of SRM 915a (corrected relative to 42Ca/44Ca = 0.31221; 48Ca/44Ca = 0.08871) from 47.1635 ± 0.0028 to 47.1649 ± 0.0047. The measurements of SRM 915b were performed with different analytical conditions (runs were prolonged till complete filament load depletion). Even if the 40Ca/44Ca ratio of SRM 915b, when corrected with the simple exponential law, appears different (47.1532 ± 0.0038) from that of SRM 915a, it becomes coincident (47.1613 ± 0.0028) when corrected with a second-order refinement. This supports the use of the improved exponential law to obtain internally consistent Ca isotope ratio for natural samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Data evaluating the chronological order of appearance of extraintestinal manifestations (EIMs) relative to the time of inflammatory bowel disease (IBD) diagnosis is currently lacking. We aimed to assess the type, frequency, and chronological order of appearance of EIMs in patients with IBD. METHODS Data from the Swiss Inflammatory Bowel Disease Cohort Study were analyzed. RESULTS The data on 1249 patients were analyzed (49.8% female, median age: 40 [interquartile range, 30-51 yr], 735 [58.8%] with Crohn's disease, 483 [38.7%] with ulcerative colitis, and 31 [2.5%] with indeterminate colitis). A total of 366 patients presented with EIMs (29.3%). Of those, 63.4% presented with 1, 26.5% with 2, 4.9% with 3, 2.5% with 4, and 2.7% with 5 EIMs during their lifetime. Patients presented with the following diseases as first EIMs: peripheral arthritis 70.0%, aphthous stomatitis 21.6%, axial arthropathy/ankylosing spondylitis 16.4%, uveitis 13.7%, erythema nodosum 12.6%, primary sclerosing cholangitis 6.6%, pyoderma gangrenosum 4.9%, and psoriasis 2.7%. In 25.8% of cases, patients presented with their first EIM before IBD was diagnosed (median time 5 mo before IBD diagnosis: range, 0-25 mo), and in 74.2% of cases, the first EIM manifested itself after IBD diagnosis (median: 92 mo; range, 29-183 mo). CONCLUSIONS In one quarter of patients with IBD, EIMs appeared before the time of IBD diagnosis. Occurrence of EIMs should prompt physicians to look for potential underlying IBD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To compare the precision of fit of long-span vs. short-span implant-supported screw-retained fixed dental prostheses (FDPs) made from computer-aided-design/computer-aided-manufactured (CAD/CAM) titanium and veneered with ceramic. The null hypothesis was that there is no difference in the vertical microgap between long-span and short-span FDPs. MATERIALS AND METHODS CAD/CAM titanium frameworks for an implant-supported maxillary FDP on implants with a flat platform were fabricated on one single master cast. Group A consisted of six 10-unit FDPs connected to six implants (FDI positions 15, 13, 11, 21, 23, 25) and group B of six 5-unit FDPs (three implants, FDI positions 21, 23, 25). The CAD/CAM system from Biodenta Swiss AG (Berneck, Switzerland) was used for digitizing (laser scanner) the master cast and anatomical CAD of each framework separately. The frameworks were milled (CAM) from a titanium grade V monobloc and veneered with porcelain. Median vertical distance between implant and FDP platforms from the non-tightened implants (one-screw test on implant 25) was calculated from mesial, buccal, and distal scanning electron microscope measurements. RESULTS All measurements showed values <40 μm. Total median vertical microgaps were 23 μm (range 2-38 μm) for group A and 7 μm (4-24 μm) for group B. The difference between the groups was statistically significant at implant 21 (P = 0.002; 97.5% CI -27.3 to -4.9) and insignificant at implant 23 (P = 0.093; -3.9 to 1.0). CONCLUSIONS CAD/CAM fabrication including laboratory scanning and porcelain firing was highly precise and reproducible for all long- and short-span FDPs. While all FDPs showed clinically acceptable values, the short-span FDPs were statistically more precise at the 5-unit span distance.