The mammalian inner ear has very limited ability to regenerate lost sensory hair cells. This deficiency becomes apparent when hair cell loss leads to hearing loss as a result of either ototoxic insult or the aging process. Coincidently, with this inability to regenerate lost hair cells, the adult cochlea does not appear to harbor cells with a proliferative capacity that could serve as progenitor cells for lost cells. In contrast, adult mammalian vestibular sensory epithelia display a limited ability for hair cell regeneration, and sphere-forming cells with stem cell features can be isolated from the adult murine vestibular system. The neonatal inner ear, however, does harbor sphere-forming stem cells residing in cochlear and vestibular tissues. Here, we provide protocols to isolate sphere-forming stem cells from neonatal vestibular and cochlear sensory epithelia as well as from the spiral ganglion. We further describe procedures for sphere propagation, cell differentiation, and characterization of inner ear cell types derived from spheres. Sphere-forming stem cells from the mouse inner ear are an important tool for the development of cellular replacement strategies of damaged inner ears and are a bona fide progenitor cell source for transplantation studies.
Resumo:
Postnatally ascertained trisomy 16 mosaicism is a rare diagnosis, with only three reported cases to date with no defined clinical phenotype. Trisomy 16 mosaicism diagnosed prenatally is common and associated with variable pregnancy outcomes ranging from stillbirth with multiple congenital abnormalities to an apparently normal newborn, making the genetic counseling very challenging. It is not clear whether uniparental disomy (UPD) 16 contributes to the phenotype, although it has been suggested that maternal UPD 16 affects the rate of intra-uterine growth retardation (IUGR) and congenital anomalies. We report on two further cases of trisomy 16 mosaicism confined to fibroblasts diagnosed postnatally. Patient 1 presented at birth with severe hypospadias, unilateral postaxial polydactyly, and different hair color with midline demarcation. His growth and development were normal at 11 months of age. Patient 2 was born with IUGR, significant craniofacial and body asymmetry, asymmetric skin hyperpigmentation, unilateral hearing loss, scoliosis, VSD, unexplained dilated cardiomyopathy, feeding difficulties, failure to thrive, and recurrent respiratory tract infections. She died at 7 months of age from respiratory failure. These two further cases of postnatally diagnosed trisomy 16 mosaicism highlight the variability of clinical features and outcome in this diagnosis. While Patient 2 presented with typical features of chromosomal mosaicism, Patient 1 had mild and transient features with essentially normal outcome, suggesting that trisomy 16 mosaicism may be under-diagnosed.
Resumo:
OBJECTIVE: Multiple studies have proved that microvascular decompression (MVD) is the treatment of choice in cases of medically refractory trigeminal neuralgia (TN). In the elderly, however, the surgical risks related to MVD are assumed to be unacceptably high and various alternative therapies have been proposed. We evaluated the outcomes of MVD in patients aged older than 65 years of age and compared them with the outcomes in a matched group of younger patients. The focus was on procedure-related morbidity rate and long-term outcome. METHODS: This was a retrospective study of 112 patients with TN operated on consecutively over 22 years. The main outcome measures were immediate and long-term postoperative pain relief and neurological status, especially function of trigeminal, facial, and cochlear nerves, as well as surgical complications. A questionnaire was used to assess long-term outcome: pain relief, duration of a pain-free period, need for pain medications, time to recurrence, pain severity, and need for additional treatment. RESULTS: The mean age was 70.35 years. The second and third branches of the trigeminal nerve were most frequently affected (37.3%). The mean follow-up period was 90 months (range, 48-295 months). Seventy-five percent of the patients were completely pain free, 11% were never pain free, and 14% experienced recurrences. No statistically significant differences existed in the outcome between the younger and older patient groups. Postoperative morbidity included trigeminal hypesthesia in 6.25%, hypacusis in 5.4%, and complete hearing loss, vertigo, and partial facial nerve palsy in 0.89% each. Cerebrospinal fluid leak and meningitis occurred in 1 patient each. There were no mortalities in both groups. CONCLUSION: MVD for TN is a safe procedure even in the elderly. The risk of serious morbidity or mortality is similar to that in younger patients. Furthermore, no significant differences in short- and long-term outcome were found. Thus, MVD is the treatment of choice in patients with medically refractory TN, unless their general condition prohibits it.
Resumo:
OBJECTIVE To confirm the clinical efficacy and safety of a direct acoustic cochlear implant. STUDY DESIGN Prospective multicenter study. SETTING The study was performed at 3 university hospitals in Europe (Germany, The Netherlands, and Switzerland). PATIENTS Fifteen patients with severe-to-profound mixed hearing loss because of otosclerosis or previous failed stapes surgery. INTERVENTION Implantation with a Codacs direct acoustic cochlear implant investigational device (ID) combined with a stapedotomy with a conventional stapes prosthesis MAIN OUTCOME MEASURES Preoperative and postoperative (3 months after activation of the investigational direct acoustic cochlear implant) audiometric evaluation measuring conventional pure tone and speech audiometry, tympanometry, aided thresholds in sound field and hearing difficulty by the Abbreviated Profile of Hearing Aid Benefit questionnaire. RESULTS The preoperative and postoperative air and bone conduction thresholds did not change significantly by the implantation with the investigational Direct Acoustic Cochlear Implant. The mean sound field thresholds (0.25-8 kHz) improved significantly by 48 dB. The word recognition scores (WRS) at 50, 65, and 80 dB SPL improved significantly by 30.4%, 75%, and 78.2%, respectively, after implantation with the investigational direct acoustic cochlear implant compared with the preoperative unaided condition. The difficulty in hearing, measured by the Abbreviated Profile of Hearing Aid Benefit, decreased by 27% after implantation with the investigational direct acoustic cochlear implant. CONCLUSION Patients with moderate-to-severe mixed hearing loss because of otosclerosis can benefit substantially using the Codacs investigational device.
Resumo:
Objective: To investigate objective and subjective effects of an adjunctive contralateral routing of signal (CROS) device at the untreated ear in patients with a unilateral cochlear implant (CI). Design: Prospective study of 10 adult experienced unilateral CI users with bilateral severe-to-profound hearing loss. Speech in noise reception (SNR) and sound localization were measured with and without the additional CROS device. SNR was measured by applying speech signals at the untreated/CROS side while noise signals came from the front (S90N0). For S0N90, signal sources were switched. Sound localization was measured in a 12-loudspeaker full circle setup. To evaluate the subjective benefit, patients tried the device for 2 weeks at home, then filled out the abbreviated Speech, Spatial and Qualities of Hearing Scale as well as the Bern benefit in single-sided deafness questionnaires. Results: In the setting S90N0, all patients showed a highly significant SNR improvement when wearing the additional CROS device (mean 6.4 dB, p < 0.001). In the unfavorable setting S0N90, only a minor deterioration of speech understanding was noted (mean -0.66 dB, p = 0.54). Sound localization did not improve substantially with CROS. In the two questionnaires, 12 of 14 items showed an improvement in mean values, but none of them was statistically significant. Conclusion: Patients with unilateral CI benefit from a contralateral CROS device, particularly in a noisy environment, when speech comes from the CROS ear side. © 2014 S. Karger AG, Basel.
Resumo:
OBJECTIVE To evaluate the speech intelligibility in noise with a new cochlear implant (CI) processor that uses a pinna effect imitating directional microphone system. STUDY DESIGN Prospective experimental study. SETTING Tertiary referral center. PATIENTS Ten experienced, unilateral CI recipients with bilateral severe-to-profound hearing loss. INTERVENTION All participants performed speech in noise tests with the Opus 2 processor (omnidirectional microphone mode only) and the newer Sonnet processor (omnidirectional and directional microphone mode). MAIN OUTCOME MEASURE The speech reception threshold (SRT) in noise was measured in four spatial settings. The test sentences were always presented from the front. The noise was arriving either from the front (S0N0), the ipsilateral side of the CI (S0NIL), the contralateral side of the CI (S0NCL), or the back (S0N180). RESULTS The directional mode improved the SRTs by 3.6 dB (p < 0.01), 2.2 dB (p < 0.01), and 1.3 dB (p < 0.05) in the S0N180, S0NIL, and S0NCL situations, when compared with the Sonnet in the omnidirectional mode. There was no statistically significant difference in the S0N0 situation. No differences between the Opus 2 and the Sonnet in the omnidirectional mode were observed. CONCLUSION Speech intelligibility with the Sonnet system was statistically different to speech recognition with the Opus 2 system suggesting that CI users might profit from the pinna effect imitating directionality mode in noisy environments.
Resumo:
Für Patienten an der Hämodialyse ist nach Versagen der klassischen arterio-venösen Fisteln oder Shunts ein direkter Gefässzugang mittels Katheter lebensnotwendig. Permanente zentralvenöse Katheter penetrieren die Hals- und Thoraxweichteile und die Haut ohne rigide Befestigung. Die Infektionsrate ist hoch und führt oft zur Explantation. Knochenverankerte Hörgeräte sind zur Behandlung bei Schalleitungsschwerhörigkeit etabliert. Das Implantat sitzt fest im Felsenbein und der Aufsatz penetriert die Haut. Schwere Infektionen, die eine Explantation nötig machen, sind sehr selten. Wir nehmen an, dass einer der Hauptgründe für die tiefe Komplikationsrate die starke Befestigung des Implantats am Knochen ist, wodurch die Hautbewegungen relativ zum Knochen minimiert werden. Basierend auf den Erfahrungen mit implantierten Hörsystemen haben wir einen perkutanen knochenverankerten Hämodialysezugang im Bereich des Felsenbeins als vorteilhafte Alternative zum herkömmlichen zentralvenösen Katheterzugang entwickelt. Dabei wurde die Felsenbeinanatomie und Knochendicke zur Lokalisierung des idealen Implantationsortes untersucht; die Schraubenstabilität im Knochen getestet; ein Titanimplantat inklusive Ventile und Katheter, sowie chirurgische Instrumente zur sicheren Implantation entwickelt. Der knochenverankerte Hämodialysezugang wurde auf Flussrate, Dichtigkeit und Reinigung getestet; die Platzierung des Katheters mittels Seldingertechnik in die V. jugularis interna über eine Halsinzision festgelegt. Die Resultate unserer Arbeit zeigen die technische Machbarkeit eines im Felsenbein verankerten neuartigen Hämodialysezuganges und bilden die Grundlage einer inzwischen bewilligten klinischen Pilotstudie.
Resumo:
CONCLUSION Bone conduction implants are useful in patients with conductive and mixed hearing loss for whom conventional surgery or hearing aids are no longer an option. They may also be used in patients affected by single-sided deafness. OBJECTIVES To establish a consensus on the quality standards required for centers willing to create a bone conduction implant program. METHOD To ensure a consistently high level of service and to provide patients with the best possible solution the members of the HEARRING network have established a set of quality standards for bone conduction implants. These standards constitute a realistic minimum attainable by all implant clinics and should be employed alongside current best practice guidelines. RESULTS Fifteen items are thoroughly analyzed. They include team structure, accommodation and clinical facilities, selection criteria, evaluation process, complete preoperative and surgical information, postoperative fitting and assessment, follow-up, device failure, clinical management, transfer of care and patient complaints.
Resumo:
Inner ear pathologies are associated with major morbidity and loss of life quality in affected patients. In many of these conditions, production of reactive oxygen-species (ROS) is thought to be a key pathological mechanism. While the sources of ROS are complex (including for example mitochondria), there is increasing evidence that activation of NOX enzymes, in particular NOX3, plays a key role. NOX3 is a multi-subunit NADPH oxidase, functionally and structurally closely related to NOX1 and NOX2. In both the vestibular and the cochlear compartments of the inner ear, high levels of NOX3 mRNA are expressed. In NOX3 mutant mice, the vestibular function is perturbed due to a lack of otoconia, while only minor alterations of hearing have been documented. However, there is increasing evidence that activation of NOX3 through drugs, noise and probably also aging, leads to hearing loss. Thus, NOX3 is an interesting target to treat and prevent inner ear pathologies and a few first animal models based on drug - or molecular therapy have been reported. So far however, there are no specific NOX3 inhibitors with a documented penetration into the inner ear. Nevertheless, certain antioxidants and non-specific NOX inhibitors diminish hearing loss in animal models. Development of small molecules inhibitors or molecular strategies against NOX3 could improve specificity and efficiency of redox-targeted treatments. In this review, we will discuss arguments for the involvement of NOX3 in inner ear pathologies and therapeutic approaches to target NOX3 activity.
A novel mutation in BCS1L associated with deafness, tubulopathy, growth retardation and microcephaly
Resumo:
We report a novel homozygous missense mutation in the ubiquinol-cytochrome c reductase synthesis-like (BCS1L) gene in two consanguineous Turkish families associated with deafness, Fanconi syndrome (tubulopathy), microcephaly, mental and growth retardation. All three patients presented with transitory metabolic acidosis in the neonatal period and development of persistent renal de Toni-Debré-Fanconi-type tubulopathy, with subsequent rachitis, short stature, microcephaly, sensorineural hearing impairment, mild mental retardation and liver dysfunction. The novel missense mutation c.142A>G (p.M48V) in BCS1L is located at a highly conserved region associated with sorting to the mitochondria. Biochemical analysis revealed an isolated complex III deficiency in skeletal muscle not detected in fibroblasts. Native polyacrylamide gel electrophoresis (PAGE) revealed normal super complex formation, but a shift in mobility of complex III most likely caused by the absence of the BCS1L-mediated insertion of Rieske Fe/S protein into complex III. These findings expand the phenotypic spectrum of BCS1L mutations, highlight the importance of biochemical analysis of different primary affected tissue and underline that neonatal lactic acidosis with multi-organ involvement may resolve after the newborn period with a relatively spared neurological outcome and survival into adulthood. CONCLUSION Mutation screening for BCS1L should be considered in the differential diagnosis of severe (proximal) tubulopathy in the newborn period. What is Known: • Mutations in BCS1L cause mitochondrial complex III deficiencies. • Phenotypic presentations of defective BCS1L range from Bjornstad to neonatal GRACILE syndrome. What is New: • Description of a novel homozygous mutation in BCS1L with transient neonatal acidosis and persistent de Toni-Debré-Fanconi-type tubulopathy. • The long survival of patients with phenotypic presentation of severe complex III deficiency is uncommon.
Resumo:
To investigate the effect of low-frequency attenuation of Bone-Anchored Hearing Aids (Bahas) in users with single-sided sensorineural deafness (SSD). The underlying notion is that low-frequency sounds up to approximately 1500 Hz reach the contralateral ear without significant attenuation and that Bahas tend to show more distortion at lower frequencies. Furthermore, to transmit low frequencies, higher moving masses are needed when compared with high frequencies.
Resumo:
Bone-anchored hearing implants (BAHI) are routinely used to alleviate the effects of the acoustic head shadow in single-sided sensorineural deafness (SSD). In this study, the influence of the directional microphone setting and the maximum power output of the BAHI sound processor on speech understanding in noise in a laboratory setting were investigated. Eight adult BAHI users with SSD participated in this pilot study. Speech understanding in noise was measured using a new Slovak speech-in-noise test in two different spatial settings, either with noise coming from the front and noise from the side of the BAHI (S90N0) or vice versa (S0N90). In both spatial settings, speech understanding was measured without a BAHI, with a Baha BP100 in omnidirectional mode, with a BP100 in directional mode, with a BP110 power in omnidirectional and with a BP110 power in directional mode. In spatial setting S90N0, speech understanding in noise with either sound processor and in either directional mode was improved by 2.2-2.8 dB (p = 0.004-0.016). In spatial setting S0N90, speech understanding in noise was reduced by either BAHI, but was significantly better by 1.0-1.8 dB, if the directional microphone system was activated (p = 0.046), when compared to the omnidirectional setting. With the limited number of subjects in this study, no statistically significant differences were found between the two sound processors.