36 resultados para reduction of acetaldehyde
Resumo:
This paper presents a novel technique to create a computerized fluoroscopy with zero-dose image updates for computer-assisted fluoroscopy-based close reduction and osteosynthesis of diaphyseal fracture of femurs. With the novel technique, repositioning of bone fragments during close fracture reduction will lead to image updates in each acquired imaging plane, which is equivalent to using several fluoroscopes simultaneously from different directions but without any X-ray radiation. Its application facilitates the whole fracture reduction and osteosynthesis procedure when combining with the existing leg length and antetorsion restoration methods and may result in great reduction of the X-ray radiation to the patient and to the surgical team. In this paper, we present the approach for achieving such a technique and the experimental results with plastic bones.
Resumo:
Dose reduction in digital panoramic radiography was studied. Intentional underexposure was performed with the Orthophos DS while six different human mandibles were radiographed. Exposure settings were 69 kV/15 mA (standard), 64 kV/16 mA, and 60 kV/16 mA. Standardized spherical defects, each either 1 or 1.25 mm in diameter, were simulated in 288 of 432 images, and seven observers decided whether defects were present or not. Areas under the receiver operating characteristics curves were calculated. They showed no significant differences in the detectability of the 1-mm defect at 69, 64, or 60 kV. For the 1.25-mm defect, no difference was found between the 69 and 60 kV images, but a statistically significant different detectability was found for 64 kV images in comparison with both 69 and 60 kV images. A dose reduction of up to 43% was ascertained with a Pedo-RT-Humanoid phantom when panoramic radiography was performed at 60 kV/16 mA. The conclusion is that with the Orthophos DS, it seems possible to reduce the dose rate of x-rays without loss of diagnostic quality in the case of radiolucent changes.
Resumo:
Chronic ethanol consumption is a strong risk factor for the development of certain types of cancer including those of the upper aerodigestive tract, the liver, the large intestine and the female breast. Multiple mechanisms are involved in alcohol-mediated carcinogenesis. Among those the action of acetaldehyde (AA), the first metabolite of ethanol oxidation is of particular interest. AA is toxic, mutagenic and carcinogenic in animal experiments. AA binds to DNA and forms carcinogenic adducts. Direct evidence of the role of AA in alcohol-associated carcinogenesis derived from genetic linkage studies in alcoholics. Polymorphisms or mutations of genes coding for AA generation or detoxifying enzymes resulting in elevated AA concentrations are associated with increased cancer risk. Approximately 40% of Japanese, Koreans or Chinese carry the AA dehydrogenase 2*2 (ALDH2*2) allele in its heterozygous form. This allele codes for an ALDH2 enzyme with little activity leading to high AA concentrations after the consumption of even small amounts of alcohol. When individuals with this allele consume ethanol chronically, a significant increased risk for upper alimentary tract and colorectal cancer is noted. In Caucasians, alcohol dehydrogenase 1C*1 (ADH1C*1) allele encodes for an ADH isoenzyme which produces 2.5 times more AA than the corresponding allele ADH1C*2. In studies with moderate to high alcohol intake, ADH1C*1 allele frequency and rate of homozygosity was found to be significantly associated with an increased risk for cancer of the upper aerodigestive tract, the liver, the colon and the female breast. These studies underline the important role of acetaldehyde in ethanol-mediated carcinogenesis.
Resumo:
Aim of the study In this study we examined the effects of Taiji on perceived stress and general self-efficacy (GSE), and investigated the mediating role of a Taiji-induced GSE increase on Taiji-related reduction of perceived stress. Materials and methods 70 healthy participants were randomly allocated either to the Taiji intervention group or the waiting list control group. The intervention lasted for 12 weeks comprising two Taiji classes per week. Before, shortly after, and two months after the intervention, we assessed the degree of perceived stress and GSE in all participants by employing the Perceived Stress Scale (PSS) and the GSE-Scale. Results Compared to controls, participants of the Taiji group showed a significantly stronger decrease of perceived stress and a higher increase in GSE from pre- to post-intervention assessment (PSS: p = 0.009; GSE: p = 0.006), as well as from pre-intervention to follow-up assessment (PSS: p = 0.018; GSE: p = 0.033). A mediator analysis based on a multiple regression approach revealed that a Taiji-related increase in GSE statistically mediated the reduction in perceived stress after Taiji as compared to baseline. Post hoc testing showed that the mediating effect of GSE was significant (p = 0.043). Conclusions Our findings confirm previously reported Taiji-related stress reducing and GSE enhancing effects with GSE increase mediating Taiji related reduction of perceived stress.
Resumo:
The goal of the present study was to examine the suitability of a short pre-stimulation (P) for 15 s followed by a latency period (L) of 30 s before cluster attachment for machine milking. In addition we tested the effect of a periodic reduction of the vacuum under the teat (VR) during the massage phase from 43 kPa to 12-15 kPa on milking characteristics and teat tissue condition. The study was carried out in 9 cows in a cross-over design. Animals were milked twice daily, and each of the 4 treatment combinations was used for six subsequent milkings (P+L vs. continuous P, and standard pulsation vs. VR, respectively). Milk flow was recorded during all experimental milkings. Longitudinal ultrasound cross sections of the teat were performed by B-mode ultrasound after the last milking of each treatment at 0, 5, and 15 min after the end of milking, respectively. None of the evaluated milking characteristics (total milk yield, main milking time, peak flow rate, average milk flow) differed between treatments. Teat measures as obtained by ultrasound cross sections showed no significant difference if individual treatments were compared at the three time points individually. However, teat wall thickness (TWT) tended to be smaller in VR vs. non-VR treatments at 5 min after milking (P=0·05). In conclusion, teat preparation consisting of a short stimulation followed by a latency period represents a similarly efficient pre-stimulation as a continuous pre-stimulation. VR seems to reduce the load on the teat tissue during milking and thus reduces the development of oedema and hence a less pronounced increase of TWT while milking characteristics are similar with or without VR.
Resumo:
OBJECTIVE To evaluate the role of an ultra-low-dose dual-source CT coronary angiography (CTCA) scan with high pitch for delimiting the range of the subsequent standard CTCA scan. METHODS 30 patients with an indication for CTCA were prospectively examined using a two-scan dual-source CTCA protocol (2.0 × 64.0 × 0.6 mm; pitch, 3.4; rotation time of 280 ms; 100 kV): Scan 1 was acquired with one-fifth of the tube current suggested by the automatic exposure control software [CareDose 4D™ (Siemens Healthcare, Erlangen, Germany) using 100 kV and 370 mAs as a reference] with the scan length from the tracheal bifurcation to the diaphragmatic border. Scan 2 was acquired with standard tube current extending with reduced scan length based on Scan 1. Nine central coronary artery segments were analysed qualitatively on both scans. RESULTS Scan 2 (105.1 ± 10.1 mm) was significantly shorter than Scan 1 (127.0 ± 8.7 mm). Image quality scores were significantly better for Scan 2. However, in 5 of 6 (83%) patients with stenotic coronary artery disease, a stenosis was already detected in Scan 1 and in 13 of 24 (54%) patients with non-stenotic coronary arteries, a stenosis was already excluded by Scan 1. Using Scan 2 as reference, the positive- and negative-predictive value of Scan 1 was 83% (5 of 6 patients) and 100% (13 of 13 patients), respectively. CONCLUSION An ultra-low-dose CTCA planning scan enables a reliable scan length reduction of the following standard CTCA scan and allows for correct diagnosis in a substantial proportion of patients. ADVANCES IN KNOWLEDGE Further dose reductions are possible owing to a change in the individual patient's imaging strategy as a prior ultra-low-dose CTCA scan may already rule out the presence of a stenosis or may lead to a direct transferal to an invasive catheter procedure.