102 resultados para performance test


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The original and modified Wells score are widely used prediction rules for pre-test probability assessment of deep vein thrombosis (DVT). The objective of this study was to compare the predictive performance of both Wells scores in unselected patients with clinical suspicion of DVT.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Synchronization programs have become standard in the dairy industry in many countries. In Switzerland, these programs are not routinely used for groups of cows, but predominantly as a therapy for individual problem cows. The objective of this study was to compare the effect of a CIDR-Select Synch and a 12-d CIDR protocol on the pregnancy rate in healthy, multiparous dairy cows in Swiss dairy farms. Methods Cows (N = 508) were randomly assigned to CIDR-Select Synch (N = 262) or 12-d CIDR (N = 246) protocols. Cows in the CIDR-Select Synch group received a CIDR and 2.5 ml of buserelin i.m. on d 0. On d 7, the CIDR insert was removed and 5 ml of dinoprost was administered i.m.. Cows in the 12-d CIDR group received the CIDR on d 0 and it was removed on d 12 (the routine CIDR protocol in Swiss dairies). On d 0 a milk sample for progesterone analysis was taken. Cows were inseminated upon observed estrus. Pregnancy was determined at or more than 35 days after artificial insemination. As a first step, the two groups were compared as to indication for treatment, breed, stud book, stall, pasture, and farmer's business using chi square tests or Fisher's exact test. Furthermore, groups were compared as to age, DIM, number of AI's, number of cows per farm, and yearly milk yield per cow using nonparametric ANOVA. A multiple logistic model was used to relate the success of the protocols to all of the available factors; in particular treatment (CIDR-Select Synch/12-d CIDR), milk progesterone value, age, DIM, previous treatment of the uterus, previous gynecological treatment, and number of preceding inseminations. Results The pregnancy rate was higher in cows following the CIDR-Select Synch compared to the 12-d CIDR protocol (50.4% vs. 22.4%; P < 0.0001). Conclusion The CIDR-Select Synch protocol may be highly recommended for multiparous dairy cows. The reduced time span of the progesterone insert decreased the number of days open, improved the pregnancy rate compared to the 12-d CIDR protocol and the cows did not to have to be handled more often.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated (1) the micromorphology by scanning electron microscopy (SEM) and (2) the adhesive performance by microtensile bond strength (μTBS) of diamond bur-treated dentin compared to Er:YAG laser-treated dentin of human primary teeth. (1) For qualitative SEM evaluation, dentin of 18 second primary molars (n = 3/method) was treated with either diamond bur as a control (group 1a: 40 μm diamond bur only (clinical situation); group 1b: grinding + 40 μm diamond bur) or with Er:YAG laser (group 2a (clinical situation, manufacturer's settings): 200 mJ/25 Hz (5 W) + 100 mJ/35 Hz (3.5 W) laser only; group 2b (experimental setting "high"): grinding + 400 mJ/20 Hz (8 W); group 2c (manufacturer's setting "finishing"): grinding + 100 mJ/35 Hz (3.5 W); group 2d (experimental setting "low"): grinding + 50 mJ/35 Hz (1.75 W)). (2) For evaluation of adhesive performance, 64 second primary molars were divided into four groups and treated as described for group 1b and groups 2b/c/d (n = 16/method), and μTBS of Clearfil SE/Clearfil Majesty Esthetic to dentin was measured. The SEM micrographs were qualitatively analyzed. The μTBS values were compared with a Kruskal-Wallis test. The significance level was set at α = 0.05. SEM micrographs showed the typical micromorphologies with a smear layer for the diamond bur groups and open dentin tubules for all laser-treated groups. However, in group 2d, the laser beam had insufficiently irradiated the dentin area, rendering the underlying ground surface partly visible. There were no statistically significant differences between μTBS values of the four groups (p = 0.394). This suggests that Er:YAG laser treatment of dentin of primary molars provides bond strengths similar to those obtained following diamond bur treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study investigates whether a 6-wk intermittent hypoxia training (IHT), designed to avoid reductions in training loads and intensities, improves the endurance performance capacity of competitive distance runners. Eighteen athletes were randomly assigned to train in normoxia [Nor group; n = 9; maximal oxygen uptake (VO2 max) = 61.5 +/- 1.1 ml x kg(-1) x min(-1)] or intermittently in hypoxia (Hyp group; n = 9; VO2 max = 64.2 +/- 1.2 ml x kg(-1) x min(-1)). Into their usual normoxic training schedule, athletes included two weekly high-intensity (second ventilatory threshold) and moderate-duration (24-40 min) training sessions, performed either in normoxia [inspired O2 fraction (FiO2) = 20.9%] or in normobaric hypoxia (FiO2) = 14.5%). Before and after training, all athletes realized 1) a normoxic and hypoxic incremental test to determine VO2 max and ventilatory thresholds (first and second ventilatory threshold), and 2) an all-out test at the pretraining minimal velocity eliciting VO2 max to determine their time to exhaustion (T(lim)) and the parameters of O2 uptake (VO2) kinetics. Only the Hyp group significantly improved VO2 max (+5% at both FiO2, P < 0.05), without changes in blood O2-carrying capacity. Moreover, T(lim) lengthened in the Hyp group only (+35%, P < 0.001), without significant modifications of VO2 kinetics. Despite similar training load, the Nor group displayed no such improvements, with unchanged VO2 max (+1%, nonsignificant), T(lim) (+10%, nonsignificant), and VO2 kinetics. In addition, T(lim) improvements in the Hyp group were not correlated with concomitant modifications of other parameters, including VO2 max or VO2 kinetics. The present IHT model, involving specific high-intensity and moderate-duration hypoxic sessions, may potentialize the metabolic stimuli of training in already trained athletes and elicit peripheral muscle adaptations, resulting in increased endurance performance capacity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Congestive heart failure (CHF) is a major public health problem. The use of B-type natriuretic peptide (BNP) tests shows promising diagnostic accuracy. Herein, we summarize the evidence on the accuracy of BNP tests in the diagnosis of CHF and compare the performance of rapid enzyme-linked immunosorbent assay (ELISA) and standard radioimmunosorbent assay (RIA) tests. METHODS: We searched electronic databases and the reference lists of included studies, and we contacted experts. Data were extracted on the study population, the type of test used, and methods. Receiver operating characteristic (ROC) plots and summary ROC curves were produced and negative likelihood ratios pooled. Random-effect meta-analysis and metaregression were used to combine data and explore sources of between-study heterogeneity. RESULTS: Nineteen studies describing 22 patient populations (9 ELISA and 13 RIA) and 9093 patients were included. The diagnosis of CHF was verified by echocardiography, radionuclide scan, or echocardiography combined with clinical criteria. The pooled negative likelihood ratio overall from random-effect meta-analysis was 0.18 (95% confidence interval [CI], 0.13-0.23). It was lower for the ELISA test (0.12; 95% CI, 0.09-0.16) than for the RIA test (0.23; 95% CI, 0.16-0.32). For a pretest probability of 20%, which is typical for patients with suspected CHF in primary care, a negative result of the ELISA test would produce a posttest probability of 2.9%; a negative RIA test, a posttest probability of 5.4%. CONCLUSIONS: The use of BNP tests to rule out CHF in primary care settings could reduce demand for echocardiography. The advantages of rapid ELISA tests need to be balanced against their higher cost.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Publication bias and related bias in meta-analysis is often examined by visually checking for asymmetry in funnel plots of treatment effect against its standard error. Formal statistical tests of funnel plot asymmetry have been proposed, but when applied to binary outcome data these can give false-positive rates that are higher than the nominal level in some situations (large treatment effects, or few events per trial, or all trials of similar sizes). We develop a modified linear regression test for funnel plot asymmetry based on the efficient score and its variance, Fisher's information. The performance of this test is compared to the other proposed tests in simulation analyses based on the characteristics of published controlled trials. When there is little or no between-trial heterogeneity, this modified test has a false-positive rate close to the nominal level while maintaining similar power to the original linear regression test ('Egger' test). When the degree of between-trial heterogeneity is large, none of the tests that have been proposed has uniformly good properties.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The Roche CARDIAC proBNP point-of-care (POC) test is the first test intended for the quantitative determination of N-terminal pro-brain natriuretic peptide (NT-proBNP) in whole blood as an aid in the diagnosis of suspected congestive heart failure, in the monitoring of patients with compensated left-ventricular dysfunction and in the risk stratification of patients with acute coronary syndromes. METHODS: A multicentre evaluation was carried out to assess the analytical performance of the POC NT-proBNP test at seven different sites. RESULTS: The majority of all coefficients of variation (CVs) obtained for within-series imprecision using native blood samples was below 10% for both 52 samples measured ten times and for 674 samples measured in duplicate. Using quality control material, the majority of CV values for day-to-day imprecision were below 14% for the low control level and below 13% for the high control level. In method comparisons for four lots of the POC NT-proBNP test with the laboratory reference method (Elecsys proBNP), the slope ranged from 0.93 to 1.10 and the intercept ranged from 1.8 to 6.9. The bias found between venous and arterial blood with the POC NT-proBNP method was < or =5%. All four lots of the POC NT-proBNP test investigated showed excellent agreement, with mean differences of between -5% and +4%. No significant interference was observed with lipaemic blood (triglyceride concentrations up to 6.3 mmol/L), icteric blood (bilirubin concentrations up to 582 micromol/L), haemolytic blood (haemoglobin concentrations up to 62 mg/L), biotin (up to 10 mg/L), rheumatoid factor (up to 42 IU/mL), or with 50 out of 52 standard or cardiological drugs in therapeutic concentrations. With bisoprolol and BNP, somewhat higher bias in the low NT-proBNP concentration range (<175 ng/L) was found. Haematocrit values between 28% and 58% had no influence on the test result. Interference may be caused by human anti-mouse antibodies (HAMA) types 1 and 2. No significant influence on the results with POC NT-proBNP was found using volumes of 140-165 muL. High NT-proBNP concentrations above the measuring range of the POC NT-proBNP test did not lead to false low results due to a potential high-dose hook effect. CONCLUSIONS: The POC NT-proBNP test showed good analytical performance and excellent agreement with the laboratory method. The POC NT-proBNP assay is therefore suitable in the POC setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The new device DIAGNOdent pen based on red laser light induced fluorescence was introduced for the detection of approximal and occlusal caries. The aim of this study was to test its performance on occlusal surfaces. The new device comes with two different sapphire fibre tips: a cylindrical tip and a conical tip. The two new sapphire fibre tips were used and compared with the tip currently available with DIAGNOdent (DD). METHODS: The teeth were selected from a pool of extracted permanent human molars, which were stored frozen at -20 degrees C, until use. Prior to being measured the teeth were defrosted and cleaned. One hundred and nineteen teeth were selected and measured with the old tip and with the two new tips of the new device by two independent assessments. The teeth were histologically prepared and assessed for caries extension. RESULTS: Specificity values for D(1), D(2) and D(3) ranged between 0.69 and 0.89, sensitivity between 0.78 and 0.96. There were no statistically significant differences obtained between the two tips of the new and the one tip of the old device (p>0.05). Intra-examiner reliability with kappa values of >0.83 was high. CONCLUSIONS: In this study, the new laser fluorescence device performed on occlusal surfaces as well as the available device.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Autism has been associated with enhanced local processing on visual tasks. Originally, this was based on findings that individuals with autism exhibited peak performance on the block design test (BDT) from the Wechsler Intelligence Scales. In autism, the neurofunctional correlates of local bias on this test have not yet been established, although there is evidence of alterations in the early visual cortex. Functional MRI was used to analyze hemodynamic responses in the striate and extrastriate visual cortex during BDT performance and a color counting control task in subjects with autism compared to healthy controls. In autism, BDT processing was accompanied by low blood oxygenation level-dependent signal changes in the right ventral quadrant of V2. Findings indicate that, in autism, locally oriented processing of the BDT is associated with altered responses of angle and grating-selective neurons, that contribute to shape representation, figure-ground, and gestalt organization. The findings favor a low-level explanation of BDT performance in autism.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: An age-controlled comparison concerning patient satisfaction and electrical performance of microfibres (DTL) and rigid contact lens (Henkes) corneal ERG electrodes was carried out. METHODS: 36 test persons underwent complete ophthalmological examination and were equally distributed into 3 age groups. Electroretinograms were recorded according to ISCEV standards. Randomly, in one eye a Henkes electrode was used and in the other eye a DTL electrode. Amplitudes of a- and b-waves and implicit times were measured and compared for the two electrode types. RESULTS: 34 of 36 test persons preferred DTL electrodes. Electrical performance concerning b-wave amplitudes was comparable. Statistically significant differences were detected only for scotopic combined cone-rod stimulation in the age groups 20 - 40 and 41 - 60 years between the different electrodes. Other recordings did not show differences. A statistically significant reduction of signal amplitudes with age was detected for scotopic isolated rod signals and combined cone-rod signals. Significance level was p < 0.05. No conjunctival or corneal erosions were found after ERG recordings for either electrode. CONCLUSIONS: Electrical performance is comparable between electrodes. For scotopic stimulations age was a significant influencing factor for signal amplitude and should be respected for normative values. DTL electrodes were preferred by the vast majority of patients. No adverse clinical effects were observed for either electrode. DTL electrodes should be preferred due to hygienic reasons (single use) and patient comfort.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Following the idea that response inhibition processes play a central role in concealing information, the present study investigated the influence of a Go/No-go task as an interfering mental activity, performed parallel to the Concealed Information Test (CIT), on the detectability of concealed information. 40 undergraduate students participated in a mock-crime experiment and simultaneously performed a CIT and a Go/No-go task. Electrodermal activity (EDA), respiration line length (RLL), heart rate (HR) and finger pulse waveform length (FPWL) were registered. Reaction times were recorded as behavioral measures in the Go/No-go task as well as in the CIT. As a within-subject control condition, the CIT was also applied without an additional task. The parallel task did not influence the mean differences of the physiological measures of the mock-crime-related probe and the irrelevant items. This finding might possibly be due to the fact that the applied parallel task induced a tonic rather than a phasic mental activity, which did not influence differential responding to CIT items. No physiological evidence for an interaction between the parallel task and sub-processes of deception (e.g. inhibition) was found. Subjects' performance in the Go/No-go parallel task did not contribute to the detection of concealed information. Generalizability needs further investigations of different variations of the parallel task.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Little is known about the genes and proteins involved in the process of human memory. To identify genetic factors related to human episodic memory performance, we conducted an ultra-high-density genome-wide screen at > 500 000 single nucleotide polymorphisms (SNPs) in a sample of normal young adults stratified for performance on an episodic recall memory test. Analysis of this data identified SNPs within the calmodulin-binding transcription activator 1 (CAMTA1) gene that were significantly associated with memory performance. A follow up study, focused on the CAMTA1 locus in an independent cohort consisting of cognitively normal young adults, singled out SNP rs4908449 with a P-value of 0.0002 as the most significant associated SNP in the region. These validated genetic findings were further supported by the identification of CAMTA1 transcript enrichment in memory-related human brain regions and through a functional magnetic resonance imaging experiment on individuals matched for memory performance that identified CAMTA1 allele-specific upregulation of medial temporal lobe brain activity in those individuals harboring the 'at-risk' allele for poorer memory performance. The CAMTA1 locus encodes a purported transcription factor that interfaces with the calcium-calmodulin system of the cell to alter gene expression patterns. Our validated genomic and functional biological findings described herein suggest a role for CAMTA1 in human episodic memory.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To determine the clinical performance of a laser fluorescence device (DIAGNOdent pen, KaVo) to discriminate between different occlusal caries depths (D(0)-D(1-4); D(0-2)-D(3,4)) in permanent molars. METHODS: In this prospective, randomized two-centre-study 120 sound/uncavitated carious sites in 120 patients were measured after visual and radiographic caries assessment. In cases of operative intervention (n=86), the lesion depths after caries removal were recorded (reference). In cases of preventive intervention (n=34), the sites were reassessed visually/radiographically after 12 months to verify the status assessed before (reference). The discrimination performance was determined statistically (Mann-Whitney test, Spearman's rho coefficient, and areas under the receiver operating characteristic curves (AUCs)). Sensitivities (SE) and specificities (SP) were plotted as a function of the measured values and cut-off values for the mentioned thresholds suggested. RESULTS: Sound sites (n=13) had significantly minor fluorescence values than carious sites (n=107) (P<0.0001) as had sites with no/enamel caries (n=63) compared to dentinal caries (n=57). The AUCs for the same discriminations were 0.92 and 0.78 (P<0.001). For the D(0)-D(1-4) threshold, a cut-off at a value of 12 (SE: 0.88, SP: 0.85) and for the D(0-2)-D(3,4) threshold at 25 (SE: 0.67, SP: 0.79) can be suggested. A moderate positive correlation between the measurements and the caries depths was calculated (rho=+0.57, P=0.01). CONCLUSION: Within this study, the device's discrimination performance for different caries depths was moderate to very good and it may be recommended as adjunct tool in the diagnosis of occlusal caries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to assess the influence of the zero value subtraction on the performance of laser fluorescence (LFpen) for approximal caries detection. Three areas (cuspal, middle and cervical) of both mesial and distal buccal surfaces of 78 permanent molars were assessed using both wedge-shaped (WDG) and tapered wedge-shaped (TWDG) tips. With the addition of the average, one cut-off value for each area was obtained and the performance was assessed. The areas under the receiver operating characteristics (ROC) curve, specificity, sensitivity and accuracy with and without the zero value subtraction were calculated. The McNemar test revealed a statistically significant difference for specificity at thresholds D(1), D(2) and D(3) (WDG) and D(1) and D(2) (TWDG) when the zero value subtraction was not performed. Influence of the zero value subtraction on the LFpen performance was observed for approximal caries detection. However, when modified cut-off values were used, the zero value subtraction could be eliminated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Over the last 4 years ADAMTS-13 measurement underwent dramatic progress with newer and simpler methods. AIMS: Blind evaluation of newer methods for their performance characteristics. DESIGN: The literature was searched for new methods and the authors invited to join the evaluation. Participants were provided with a set of 60 coded frozen plasmas that were prepared centrally by dilutions of one ADAMTS-13-deficient plasma (arbitrarily set at 0%) into one normal-pooled plasma (set at 100%). There were six different test plasmas ranging from 100% to 0%. Each plasma was tested 'blind' 10 times by each method and results expressed as percentage vs. the local and the common standard provided by the organizer. RESULTS: There were eight functional and three antigen assays. Linearity of observed-vs.-expected ADAMTS-13 levels assessed as r2 ranged from 0.931 to 0.998. Between-run reproducibility expressed as the (mean) CV for repeated measurements was below 10% for three methods, 10-15% for five methods and up to 20% for the remaining three. F-values (analysis of variance) calculated to assess the capacity to distinguish between ADAMTS-13 levels (the higher the F-value, the better the capacity) ranged from 3965 to 137. Between-method variability (CV) amounted to 24.8% when calculated vs. the local and to 20.5% when calculated vs. the common standard. Comparative analysis showed that functional assays employing modified von Willebrand factor peptides as substrate for ADAMTS-13 offer the best performance characteristics. CONCLUSIONS: New assays for ADAMTS-13 have the potential to make the investigation/management of patients with thrombotic microangiopathies much easier than in the past.