177 resultados para percutaneous transluminal coronary angioplasty
Resumo:
The aim of this analysis was to assess the effect of body mass index (BMI) on 1-year outcomes in patients enrolled in a contemporary percutaneous coronary intervention trial comparing a sirolimus-eluting stent with a durable polymer to a biolimus-eluting stent with a biodegradable polymer. A total of 1,707 patients who underwent percutaneous coronary intervention were randomized to treatment with either biolimus-eluting stents (n = 857) or sirolimus-eluting stents (n = 850). Patients were assigned to 1 of 3 groups according to BMI: normal (<25 kg/m(2)), overweight (25 to 30 kg/m(2)), or obese (>30 kg/m(2)). At 1 year, the incidence of the composite of cardiac death, myocardial infarction, and clinically justified target vessel revascularization was assessed. In addition, rates of clinically justified target lesion revascularization and stent thrombosis were assessed. Cox proportional-hazards analysis, adjusted for clinical differences, was used to develop models for 1-year mortality. Forty-five percent of the patients (n = 770) were overweight, 26% (n = 434) were obese, and 29% (n = 497) had normal BMIs. At 1-year follow-up, the cumulative rate of cardiac death, myocardial infarction, and clinically justified target vessel revascularization was significantly higher in the obese group (8.7% in normal-weight, 11.3% in overweight, and 14.5% in obese patients, p = 0.01). BMI (hazard ratio 1.47, 95% confidence interval 1.02 to 2.14, p = 0.04) was an independent predictor of stent thrombosis. Stent type had no impact on the composite of cardiac death, myocardial infarction, and clinically justified target vessel revascularization at 1 year in the 3 BMI groups (hazard ratio 1.08, 95% confidence interval 0.63 to 1.83, p = 0.73). In conclusion, BMI was an independent predictor of major adverse cardiac events at 1-year clinical follow-up. The higher incidence of stent thrombosis in the obese group may suggest the need for a weight-adjusted dose of clopidogrel.
Resumo:
This registry has aimed to collect data on cardiac catheterisation procedures in Europe in 2006.
Resumo:
Diagnostic coronary balloon occlusion (CBO) is mandatory for collateral function assessment, during angioscopy and optical coherence imaging, and when using certain coronary protection devices against emboli. Thus far, the safety of diagnostic CBO regarding procedural and long-term complications in normal coronary arteries has not been studied. In 316 patients, diagnostic CBO was performed for collateral function measurement in 426 angiographically normal vessels. The angioplasty balloon was inflated for 60 to 120 seconds using inflation pressures of 1 to 3 atm, followed by control angiography during and after CBO. Patients were divided into groups with entirely normal (n = 133) and partially normal (n = 183) vessels. Primary end points were procedural and long-term complications. De novo stenosis development was assessed by quantitative coronary angiography in 35% of the patients. Secondary end points were cardiac events at 5 years of follow-up. Procedural complications occurred in 1 patient (0.2%). In 150 repeat angiographic procedures in 92 patients (follow-up duration 10 +/- 15 months), quantitative coronary angiography revealed no difference in percentage diameter narrowing between baseline and follow-up (4.1% vs 3.9%, p = 0.69). During follow-up periods of 14 and 72 months, respectively, a new stenotic lesion was detected in 1 patient in each group (1.3%). Major cardiac events and percutaneous coronary intervention for stable angina were less frequent in the group with entirely normal than with partially normal vessels (0.8% vs 5.5%, p = 0.02, and 0.8% vs 18%, p <0.0001). In conclusion, low-inflation pressure diagnostic CBO in angiographically normal coronary arteries bears a minimal risk for procedural and long-term complications and can therefore be regarded as a safe procedure.
Resumo:
There is an interest to keep the arterial access site for percutaneous coronary interventions (PCI) small. Using sheaths for introduction of arterial catheters is standard. The effective outer diameter of the usual introducer sheaths is about 1.5 French (F) larger than the labeled size. Omitting the sheath affords a smaller access without loss of working lumen.
Resumo:
Coronary artery disease (CAD) is frequently present in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). While revascularisation affects peri-operative outcome in patients undergoing surgical aortic valve replacement, the impact of percutaneous coronary intervention (PCI) in patients undergoing TAVI is not well established.
Resumo:
Unprotected left main (ULM) coronary artery disease is encountered in 3%-10% of coronary angiograms and is associated with high mortality. The survival of patients with ULM disease presenting with acute coronary syndromes (ACS) depends on different variables and is lowest in those with cardiogenic shock (CS). The aim of the present study was to estimate the impact of baseline characteristics on the subsequent clinical outcome in patients treated by percutaneous coronary intervention (PCI) of ULM for ACS.
Resumo:
To investigate the ability of SYNTAX score and Clinical SYNTAX score (CSS) to predict very long-term outcomes in an all-comers population receiving drug-eluting stents.
Resumo:
This study sought to assess the impact of the SYNTAX (Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery) score (SXscore) on clinical outcomes in patients undergoing percutaneous coronary intervention.
Resumo:
This study sought to assess outcomes in patients with ST-segment elevation myocardial infarction undergoing primary percutaneous coronary intervention (PCI) for unprotected left main (LM) disease.
Resumo:
The aim of this study was to investigate the impact of patient and lesion complexity on outcomes with newer-generation zotarolimus-eluting stents (ZES) and everolimus-eluting stents (EES).
Resumo:
The purpose of this study was to assess the impact of body mass index (BMI) on clinical outcome of patients treated by percutaneous coronary intervention (PCI) using drug-eluting stents. Patients were stratified according to BMI as normal (<25 kg/m(2)), overweight (25 to 30 kg/m(2)), or obese (>30 kg/m(2)). At 5-year follow-up all-cause death, myocardial infarction, clinically justified target vessel revascularization (TVR), and definite stent thrombosis were assessed. A complete dataset was available in 7,427 patients, of which 45%, 22%, and 33% were classified according to BMI as overweight, obese, and normal, respectively. Mean age of patients was significantly older in those with a normal BMI (p <0.05). Incidence of diabetes mellitus, hypertension, and dyslipidemia increased as BMI increased (p <0.05). Significantly higher rates of TVR (15.3% vs 12.8%, p = 0.02) and early stent thrombosis (1.5% vs 0.9%, p = 0.04) were observed in the obese compared to the normal BMI group. No significant difference among the 3 BMI groups was observed for the composite of death/myocardial infarction/TVR or for definite stent thrombosis at 5 years, whereas the normal BMI group was at higher risk for all-cause death at 5 years (obese vs normal BMI, hazard ratio 0.74, confidence interval 0.53 to 0.99, p = 0.05; overweight vs normal BMI, hazard ratio 0.73, confidence interval 0.59 to 0.94, p = 0.01) in the multivariate Cox proportional hazard model. Age resulted in a linearly dependent covariate with BMI in the all-cause 5-year mortality multivariate model (p = 0.001). In conclusion, the "obesity paradox" observed in 5-year all-cause mortality could be explained by the higher rate of elderly patients in the normal BMI group and the existence of colinearity between BMI and age. However, obese patients had a higher rate of TVR and early stent thrombosis and a higher rate of other risk factors such as diabetes mellitus, hypertension, and hypercholesterolemia.
Resumo:
Background— The age, creatinine, and ejection fraction (ACEF) score (age/left ventricular ejection fraction+1 if creatinine >2.0 mg/dL) has been established as an effective predictor of clinical outcomes in patients undergoing elective coronary artery bypass surgery; however, its utility in “all-comer” patients undergoing percutaneous coronary intervention is yet unexplored. Methods and Results— The ACEF score was calculated for 1208 of the 1707 patients enrolled in the LEADERS trial. Post hoc analysis was performed by stratifying clinical outcomes at the 1-year follow-up according to ACEF score tertiles: ACEFlow ≤1.0225, 1.0225< ACEFmid ≤1.277, and ACEFhigh >1.277. At 1-year follow-up, there was a significantly lower number of patients with major adverse cardiac event–free survival in the highest tertile of the ACEF score (ACEFlow=92.1%, ACEFmid=89.5%, and ACEFhigh=86.1%; P=0.0218). Cardiac death was less frequent in ACEFlow than in ACEFmid and ACEFhigh (0.7% vs 2.2% vs 4.5%; hazard ratio=2.22, P=0.002) patients. Rates of myocardial infarction were significantly higher in patients with a high ACEF score (6.7% for ACEFhigh vs 5.2% for ACEFmid and 2.5% for ACEFlow; hazard ratio=1.6, P=0.006). Clinically driven target-vessel revascularization also tended to be higher in the ACEFhigh group, but the difference among the 3 groups did not reach statistical significance. The rate of composite definite, possible, and probable stent thrombosis was also higher in the ACEFhigh group (ACEFlow=1.2%, ACEFmid=3.5%, and ACEFhigh=6.2%; hazard ratio=2.04, P<0.001). Conclusions— ACEF score may be a simple way to stratify risk of events in patients treated with percutaneous coronary intervention with respect to mortality and risk of myocardial infarction.
Resumo:
The efficacy of durable polymer drug-eluting stents (DES) is delivered at the expense of delayed healing of the stented vessel. Biodegradable polymer DES aim to avoid this shortcoming and may potentially improve long-term clinical outcomes, with benefit expected to accrue over time. We sought to compare long-term outcomes in patients treated with biodegradable polymer DES vs. durable polymer sirolimus-eluting stents (SES).