86 resultados para needle examination


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Currently, in forensic medicine cross-sectional imaging gains recognition and a wide use as a non-invasive examination approach. Today, computed tomography (CT) or magnetic resonance imaging that are available for patients are unable to provide tissue information on the cellular level in a non-invasive manner and also diatom detection, DNA, bacteriological, chemical toxicological and other specific tissue analyses are impossible using radiology. We hypothesised that post-mortem minimally invasive tissue sampling using needle biopsies under CT guidance might significantly enhance the potential of virtual autopsy. The purpose of this study was to test the use of a clinically approved biopsy needle for minimally invasive post-mortem sampling of tissue specimens under CT guidance. MATERIAL AND METHODS: ACN III biopsy core needles 14 gauge x 160 mm with automatic pistol device were used on three bodies dedicated to research from the local anatomical institute. Tissue probes from the brain, heart, lung, liver, spleen, kidney and muscle tissue were obtained under CT fluoroscopy. RESULTS: CT fluoroscopy enabled accurate placement of the needle within the organs and tissues. The needles allowed for sampling of tissue probes with a mean width of 1.7 mm (range 1.2-2 mm) and the maximal length of 20 mm at all locations. The obtained tissue specimens were of sufficient size and adequate quality for histological analysis. CONCLUSION: Our results indicate that, similar to the clinical experience but in many more organs, the tissue specimens obtained using the clinically approved biopsy needle are of a sufficient size and adequate quality for a histological examination. We suggest that post-mortem biopsy using the ACN III needle under CT guidance may become a reliable method for targeted sampling of tissue probes of the body.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The Baxter Amicus Version 2.51 (A) and the Gambro BCT Trima Accel Version 5.0 (T) cell separators may produce multiple platelet (PLT) concentrates within a single donation. STUDY DESIGN AND METHODS: The single-needle multiple plateletpheresis procedures of the two devices were compared in a prospective, randomized, paired crossover study in 60 donors. The 120 donations were compared for donor comfort, collection efficiency, residual white blood cell (WBC) count, and (in selected patients) corrected count increment (CCI). RESULTS: The mean PLT yield and the resultant mean number of units per donation were significantly lower for A (6.06 x 10(11) vs. 7.48 x 10(11) and 2.57 vs. 3.19, respectively, both p < 0.001), in spite of a longer apheresis duration (89 min vs. 79 min; p < 0.001). This resulted in a higher collection rate of T (5.68 x 10(11) PLTs/hr vs. 4.10 x 10(11) PLTs/hr, p < 0.001). Residual WBC count of every unit was fewer than 5 x 10(6), but significantly fewer A-PLT donations contained more than 10(5) WBCs per unit (1 vs. 9, p = 0.008). Although the ACD-A consumption was slightly higher for A (489 mL vs. 469 mL, p = 0.04), a trend to a higher frequency of side effects was found for T (42.4% vs. 23.7%, p = 0.06). The 1-hour CCIs of 33 transfused A-PLT units were comparable with those of 43 T-PLT units (11.8 vs. 13.9, p = 0.480). CONCLUSIONS: Both cell separators showed safe collections of up to 4 PLT units per donation with adequate CCI. T produced a higher PLT yield despite shorter apheresis duration, but with slightly higher residual WBC counts and a trend to a higher side-effect frequency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The examination of urine in children can be very complex, due to the difficulty to obtain clean urine specimens in infants and toddlers. Clean catch is an easy system to obtain urine but patience is needed. Transurethral catheterization or suprapubic aspiration is useful in infants and toddlers with sign of pyelonephritis. Urine bag specimens are not useful in the diagnosis of urinary tract infection because of the high rate of false positive cultures. The 24 hours urine collection is frequently replaced by a spot urine and the ratio of the measured substances with the urine creatinine are calculated. Urine microscopy is needed for the evaluation of pathological results in the dipstick testing: confirm that red urine is due to haematuria by demonstration of red blood cells on urine microscopy, dysmorphic cells and red-cell casts are pathognomonic of glomerular bleeding, white-cell casts signify glomerular inflammation and bacteria are easily seen in unstained urine. A urine culture is pathologic if the colony count exceeds 10(4) in the transurethral catheterization or clean void. In the suprapubic aspiration is any number of colony pathologic. Urate crystals in the urine of infants may cause a pink discoloration to nappies. Urine screenings are not very useful and should be performed only at the age of 5 years or by sexual-active adolescents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During 2003, a total of 258 new patients with oral soft tissue lesions were admitted at the Stomatology Service of the Department of Oral Surgery and Stomatology at the University of Berne. For the present study, 185 patients with clinically and histopathologically verified diagnoses were included. The following data was collected: prevalence of oral mucosal lesions, distribution of benign, precancerous and malign lesions in different age groups, and the concordance of the referral with the working diagnosis at the Stomatology Service. The most frequent pathological soft tissue findings were fibrous hyperplasias (n = 44) and oral lichen planus (n = 30). Precancerous lesions were present in 41 cases (30 patients with oral lichen planus, eleven oral leukoplakias), and ten patients had oral malignomas. Most lesions were found in patients between the age of 40 and 60 years. The referral diagnosis concurred in 36.6% (n = 67) of the cases with the definite diagnosis before initiation of treatment, the working diagnosis in 70% (n = 128) of the cases. Therefore, it can be concluded that a specialised Stomatology Service serves as a center of competence due to large numbers of patients/cases seen and treated, and the resulting high level of clinical experience of the staff. Moreover, it is important in the primary diagnosis of oral squamous cell carcinoma, in collaboration with the referring dentist in private practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective-To evaluate pulsed-wave Doppler spectral parameters as a method for distinguishing between neoplastic and inflammatory peripheral lymphadenopathy in dogs. Sample Population-40 superficial lymph nodes from 33 dogs with peripheral lymphadenopathy. Procedures-3 Doppler spectral tracings were recorded from each node. Spectral Doppler analysis including assessment of the resistive index, peak systolic velocity-to-end diastolic velocity (S:D) ratio, diastolic notch velocity-to-peak systolic velocity (N:S) ratio, and end diastolic velocity-to-diastolic notch velocity ratio was performed for each tracing. Several calculation methods were used to determine the Doppler indices for each lymph node. After the ultrasonographic examination, fine needle aspirates or excisional biopsy specimens of the examined lymph nodes were obtained, and lymphadenopathy was classified as either inflammatory or neoplastic (lymphomatous or metastatic) via cytologic or histologic examination. Results of Doppler analysis were compared with cytologic or histopathologic findings. Results-The Doppler index with the highest diagnostic accuracy was the S:D ratio calculated from the first recorded tracing; a cutoff value of 3.22 yielded sensitivity of 91%, specificity of 100%, and negative predictive value of 89% for detection of neoplasia. Overall diagnostic accuracy was 95%. At a sensitivity of 100%, the most accurate index was the N:S ratio calculated from the first recorded tracing; a cutoff value of 0.45 yielded specificity of 67%, positive predictive value of 81%, and overall diagnostic accuracy of 86.5%. Conclusions and Clinical Relevance-Results suggested that noninvasive Doppler spectral analysis may be useful in the diagnosis of neoplastic versus inflammatory peripheral lymphadenopathy in dogs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Pericard 6 (P6) is one of the most frequently used acupuncture points, especially in preventing nausea and vomiting. At this point, the median nerve is located very superficially. OBJECTIVES: To investigate the distance between the needle tip and the median nerve during acupuncture at P6, we conducted a prospective observational ultrasound (US) imaging study. We tested the hypothesis that de qi (a sensation that is typical of acupuncture needling) is evoked when the needle comes into contact with the epineural tissue and thereby prevents nerve penetration. SETTINGS/LOCATION: The outpatient pain clinic of the Medical University of Vienna, Austria. SUBJECTS: Fifty (50) patients receiving acupuncture treatment including P6 bilaterally. INTERVENTIONS: Patients were examined at both forearms using US (a 10-MHz linear transducer) after insertion of the needle at P6. OUTCOME MEASURES: The distance between the needle tip and the median nerve, the number of nerve contacts and nerve penetrations, as well as the number of successfully elicited de qi sensations were recorded. RESULTS: Complete data could be obtained from 97 cases. The mean distance from the needle tip to the nerve was 1.8 mm (standard deviation 2.2; range 0-11.3). Nerve contacts were recorded in 52 cases, in 14 of which the nerve was penetrated by the needle. De qi was elicited in 85 cases. We found no association between the number of nerve contacts and de qi. The 1-week follow-up showed no complications or neurologic problems. CONCLUSIONS: This is the first investigation demonstrating the relationship between acupuncture needle placement and adjacent neural structures using US technology. The rate of median nerve penetrations by the acupuncture needle at P6 was surprisingly high, but these seemed to carry no risk of neurologic sequelae. De qi at P6 does not depend on median nerve contact, nor does it prevent median nerve penetration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Recent advances in medical imaging have brought post-mortem minimally invasive computed tomography (CT) guided percutaneous biopsy to public attention. AIMS: The goal of the following study was to facilitate and automate post-mortem biopsy, to suppress radiation exposure to the investigator, as may occur when tissue sampling under computer tomographic guidance, and to minimize the number of needle insertion attempts for each target for a single puncture. METHODS AND MATERIALS: Clinically approved and post-mortem tested ACN-III biopsy core needles (14 gauge x 160 mm) with an automatic pistol device (Bard Magnum, Medical Device Technologies, Denmark) were used for probe sampling. The needles were navigated in gelatine/peas phantom, ex vivo porcine model and subsequently in two human bodies using a navigation system (MEM centre/ISTB Medical Application Framework, Marvin, Bern, Switzerland) with guidance frame and a CT (Emotion 6, Siemens, Germany). RESULTS: Biopsy of all peas could be performed within a single attempt. The average distance between the inserted needle tip and the pea centre was 1.4mm (n=10; SD 0.065 mm; range 0-2.3 mm). The targets in the porcine liver were also accurately punctured. The average of the distance between the needle tip and the target was 0.5 mm (range 0-1 mm). Biopsies of brain, heart, lung, liver, pancreas, spleen, and kidney were performed on human corpses. For each target the biopsy needle was only inserted once. The examination of one body with sampling of tissue probes at the above-mentioned locations took approximately 45 min. CONCLUSIONS: Post-mortem navigated biopsy can reliably provide tissue samples from different body locations. Since the continuous update of positional data of the body and the biopsy needle is performed using optical tracking, no control CT images verifying the positional data are necessary and no radiation exposure to the investigator need be taken into account. Furthermore, the number of needle insertions for each target can be minimized to a single one with the ex vivo proven adequate accuracy and, in contrast to conventional CT guided biopsy, the insertion angle may be oblique. Navigation for minimally invasive tissue sampling is a useful addition to post-mortem CT guided biopsy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new scoring system, the Basic Erosive Wear Examination (BEWE), has been designed to provide a simple tool for use in general practice and to allow comparison to other more discriminative indices. The most severely affected surface in each sextant is recorded with a four level score and the cumulative score classified and matched to risk levels which guide the management of the condition. The BEWE allows re-analysis and integration of results from existing studies and, in time, should initiate a consensus within the scientific community and so avoid continued proliferation of indices. Finally, this process should lead to the development of an internationally accepted, standardised and validated index. The BEWE further aims to increase the awareness of tooth erosion amongst clinicians and general dental practitioners and to provide a guide as to its management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared the performance of fluorescence-based methods, radiographic examination, and International Caries Detection and Assessment System (ICDAS) II on occlusal surfaces. One hundred and nineteen permanent human molars were assessed twice by 2 experienced dentists using the laser fluorescence (LF and LFpen) and fluorescence camera (FC) devices, ICDAS II and bitewing radiographs (BW). After measuring, the teeth were histologically prepared and assessed for caries extension. The sensitivities for dentine caries detection were 0.86 (FC), 0.78 (LFpen), 0.73 (ICDAS II), 0.51 (LF) and 0.34 (BW). The specificities were 0.97 (BW), 0.89 (LF), 0.65 (ICDAS II), 0.63 (FC) and 0.56 (LFpen). BW presented the highest values of likelihood ratio (LR)+ (12.47) and LR- (0.68). Rank correlations with histology were 0.53 (LF), 0.52 (LFpen), 0.41 (FC), 0.59 (ICDAS II) and 0.57 (BW). The area under the ROC curve varied from 0.72 to 0.83. Inter- and intraexaminer intraclass correlation values were respectively 0.90 and 0.85 (LF), 0.93 and 0.87 (LFpen) and 0.85 and 0.76 (FC). The ICDAS II kappa values were 0.51 (interexaminer) and 0.61 (intraexaminer). The BW kappa values were 0.50 (interexaminer) and 0.62 (intraexaminer). The Bland and Altman limits of agreement were 46.0 and 38.2 (LF), 55.6 and 40.0 (LFpen) and 1.12 and 0.80 (FC), for intra- and interexaminer reproducibilities. The posttest probability for dentine caries detection was high for BW and LF. In conclusion, LFpen, FC and ICDAS II presented better sensitivity and LF and BW better specificity. ICDAS II combined with BW showed the best performance and is the best combination for detecting caries on occlusal surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Based on a subgroup analysis of 18-month BAsel Stent Kosten Effektivitäts Trial (BASKET) outcome data, we hypothesized that very late (> 12 months) stent thrombosis occurs predominantly after drug-eluting stent implantation in large native coronary vessel stenting. METHODS: To prove or refute this hypothesis, we set up an 11-center 4-country prospective trial of 2260 consecutive patients treated with > or = 3.0-mm stents only, randomized to receive Cypher (Johnson ; Johnson, Miami Lakes, FL), Vision (Abbott Vascular, Abbott Laboratories, IL), or Xience stents (Abbott Vascular). Only patients with left main or bypass graft disease, in-stent restenosis or stent thrombosis, in need of nonheart surgery, at increased bleeding risk, without compliance/consent are excluded. All patients are treated with dual antiplatelet therapy for 12 months. The primary end point will be cardiac death/nonfatal myocardial infarction after 24 months with further follow-up up to 5 years. RESULTS: By June 12, 229 patients (10% of the planned total) were included with a baseline risk similar to that of the same subgroup of BASKET (n = 588). CONCLUSIONS: This study will answer several important questions of contemporary stent use in patients with large native vessel stenting. The 2-year death/myocardial infarction-as well as target vessel revascularization-and bleeding rates in these patients with a first- versus second-generation drug-eluting stent should demonstrate the benefit or harm of these stents compared to cobalt-chromium bare-metal stents in this relevant, low-risk group of everyday patients. In addition, a comparison with similar BASKET patients will allow to estimate the impact of 12- versus 6-month dual antiplatelet therapy on these outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In an experiment on one of the authors, we used ultrasound to visualise an acupuncture needle completely perforating the median nerve at the acupuncture point PC6. During this procedure only a slight sensation occurred, and no pain. We conclude that, in individual cases, the median nerve might be perforated without causing pain or neurological problems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to analyze and compare the value of fine-needle aspiration cytology (FNAC) and frozen section (FS) analysis in the assessment of parotid gland tumors. STUDY DESIGN: Chart review and cross-sectional analysis. SUBJECTS AND METHODS: FNAC and FS analysis of 110 parotid tumors, 68 malignancies and 42 benign tumors, were analyzed and compared with the final histopathologic diagnosis. RESULTS: The accuracy, sensitivity, and specificity of FNAC in detecting malignant tumors were 79 percent, 74 percent, and 88 percent, respectively. On FS analysis, the accuracy, sensitivity, and specificity in detecting malignant tumors were 94 percent, 93 percent, and 95 percent, respectively. The histologic tumor type was correctly diagnosed by FNAC and FS in 27 of 42 (64%) and 39 of 42 (93%) benign tumors, respectively, and in 24 of 68 (35%) and 49 of 68 (72%) malignant neoplasms, respectively. CONCLUSION: The current analysis showed a superiority of FS compared with FNAC regarding the diagnosis of malignancy and tumor typing. FNAC alone is not prone to determine the surgical management of parotid malignancies.