165 resultados para low drug dose
Resumo:
CT pulmonary angiography is the currently accepted standard in ruling out acute pulmonary embolism. Issues of radiation dose received by patients via CT have been extensively disputed by radiologists and reported by the media. In recent years there has been considerable research performed to find ways for reducing radiation exposure from CT. Herein, we will discuss specific measures that have been shown to be valuable for CT pulmonary angiography. The limitations and the potential benefits of reduced CT peak tube kilovoltage will be detailed as this method is capable of reducing both radiation exposure and iodine load to the patient simultaneously. We discuss some of the emerging tools, which will hopefully play a significant role in wider acceptance of low-dose CT pulmonary angiography protocols.
Resumo:
recombinant activated factor VII (rFVIIa) is used off-label for massive bleeding. There is no convincing evidence of the benefits of this practice and the minimal effective dose is unknown. The aim of the study was to evaluate our in-house guideline recommending a low dose of 60 μg/kg for off-label use of rFVIIa.
Resumo:
The temporal bone is ideal for low-dose CT because of its intrinsic high contrast. The aim of this study was to retrospectively evaluate image quality and radiation doses of a new low-dose versus a standard high-dose pediatric temporal bone CT protocol and to review dosimetric data from the literature.
Resumo:
PURPOSE: The purpose of our study was to retrospectively evaluate the specificity, sensitivity and accuracy of computed tomography (CT), digital radiography (DR) and low-dose linear slit digital radiography (LSDR, Lodox(®)) in the detection of internal cocaine containers. METHODS: Institutional review board approval was obtained. The study collectively consisted of 83 patients (76 males, 7 females, 16-45 years) suspected of having incorporated cocaine drug containers. All underwent radiological imaging; a total of 135 exams were performed: nCT=35, nDR=70, nLSDR=30. An overall calculation of all "drug mules" and a specific evaluation of body packers, pushers and stuffers were performed. The gold standard was stool examination in a dedicated holding cell equipped with a drug toilet. RESULTS: There were 54 drug mules identified in this study. CT of all drug carriers showed the highest diagnostic accuracy 97.1%, sensitivity 100% and specificity 94.1%. DR in all cases was 71.4% accurate, 58.3% sensitive and 85.3% specific. LSDR of all patients with internal cocaine was 60% accurate, 57.9% sensitive and 63.4% specific. CONCLUSIONS: CT was the most accurate test studied. Therefore, the detection of internal cocaine drug packs should be performed by CT, rather than by conventional X-ray, in order to apply the most sensitive exam in the medico-legal investigation of suspected drug carriers. Nevertheless, the higher radiation applied by CT than by DR or LSDR needs to be considered. Future studies should include evaluation of low dose CT protocols in order to address germane issues and to reduce dosage.
Resumo:
The activation of 5-hydroxytryptamine-3 (5-HT-3) receptors in spinal cord can enhance intrinsic spinal mechanisms of central hypersensitivity, possibly leading to exaggerated pain responses. Clinical studies suggest that 5-HT-3 receptor antagonists may have an analgesic effect. This randomized, double-blind, placebo-controlled crossover study tested the hypothesis that the 5-HT-3 receptor antagonist tropisetron attenuates pain and central hypersensitivity in patients with chronic low back pain. Thirty patients with chronic low back pain, 15 of whom were women (aged 53 ± 14 years) and 15 men (aged 48 ± 14 years), were studied. A single intravenous injection of 0.9% saline solution, tropisetron 2mg, and tropisetron 5mg was administrated in 3 different sessions, in a double-blind crossover manner. The main outcome was the visual analogue scale (VAS) score of spontaneous low back pain before, and 15, 30, 60, and 90 minutes after drug administration. Secondary outcomes were nociceptive withdrawal reflexes to single and repeated electrical stimulation, area of reflex receptive fields, pressure pain detection and tolerance thresholds, conditioned pain modulation, and area of clinical pain. The data were analyzed by analysis of variance and panel multiple regressions. All 3 treatments reduced VAS scores. However, there was no statistically significant difference between tropisetron and placebo in VAS scores. Compared to placebo, tropisetron produced a statistically significant increase in pain threshold after single electrical stimulation, but no difference in all other secondary outcomes was found. A single-dose intravenous administration of tropisetron in patients with chronic low back pain had no significant specific effect on intensity of pain and most parameters of central hypersensitivity.
Resumo:
To analyze the outcome after low-dose-rate (LDR) or high-dose-rate (HDR) brachytherapy for lip cancer.
Resumo:
To assess the effect of radiation dose reduction on the appearance and visual quantification of specific CT patterns of fungal infection in immuno-compromised patients.
Resumo:
The purpose of this study was to simulate pulmonary emboli (PE) and image quality at low tube energy and reduced contrast material volume in normal-dose pulmonary CT angiography (CTA) images and to analyze the diagnostic accuracy with normal- and low-dose pulmonary CTA.
Resumo:
OBJECTIVE: Foreign body ingestion is common and potentially lethal. This study evaluates the use of low-dose Statscans (LODOX) in emergency departments. DESIGN: This comparative cross-sectional study retrospectively assessed 28 289 digital chest x-rays and 2301 LODOX scans performed between 2006 and 2010 at a tertiary emergency centre. The radiographic appearance, image quality and location of ingested foreign bodies were evaluated in standard digital chest and LODOX radiography. The mean irradiation (μSv) and cumulative mean radiation dose per patient with the ingested foreign body were calculated according to literature-based data, together with the sensitivity and specificity for each modality. RESULTS: A total of 62 foreign bodies were detected in 39 patients, of whom 19 were investigated with LODOX and 20 with conventional digital chest radiography. Thirty-three foreign bodies were located in the two upper abdominal quadrants, 21 in the lower quadrants-which are not visible on conventional digital chest radiography-seven in the oesophagus and one in the bronchial system. The sensitivity and specificity of digital chest radiography were 44.4% and 94.1%, respectively, and for the LODOX Statscan 90% and 100%, respectively. The calculated mean radiation dose for LODOX investigations was 184 μS, compared with 524 μS for digital chest radiography. CONCLUSIONS: LODOX Statscan is superior to digital chest radiography in the diagnostic work-up of ingested foreign bodies because it makes it possible to enlarge the field of view to the entire body, has higher sensitivity and specificity, and reduces the radiation dose by 65%.
Resumo:
Vinblastine sulphate (VBS) is an anticancer drug that acts by disrupting microtubule dynamics of highly mitotic tissue cells. The consequences of VBS on the olfactory mucosa (OM), a tissue with high mitotic numbers, are not clearly understood. We used qualitative and quantitative methods to determine the structural changes that may be produced on the rabbit OM by VBS. Following a single dose (0.31 mg/kg) of this drug, the structure of the mucosa was greatly altered on the first 3-5 days. The alteration was characterized by disarrangement of the normal layering of nuclei of the epithelia, degeneration of axonal bundles, occurrence of blood vessels within the bundles, localized death of cells of Bowman's glands and glandular degeneration. Surprisingly on or after day 7 and progressively to day 15 post-exposure, the OM was observed to regenerate and acquire normal morphology, and the vessels disappeared from the bundles. Relative to control values, bundle diameters, olfactory cell densities and cilia numbers decreased to as low as 53.1, 75.2 and 71.4%, respectively, on day 5. Volume density for the bundles, which was 28.6% in controls, decreased to a lowest value of 16.8% on day 5. In contrast, the volume density for the blood vessels was significantly lower in controls (19.9%) than in treated animals at day 2 (25.8%), day 3 (34.3%) and day 5 (31.5%). These findings suggest that the changes induced on the rabbit OM by VBS are transient and that regenerative recovery leads to the restoration of the normal structure of the mucosa.
Resumo:
To assess the ability of low-dose CT to detect and characterize the most common CT patterns of pulmonary disease.
Resumo:
To evaluate the antibiotic treatment regime in patients with indwelling JJ stents, the benefits and disadvantages of a peri-interventional antibiotic prophylaxis were compared with those of a continuous low-dose antibiotic treatment in a prospective randomised trial.