93 resultados para instrument


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To (a) develop the Women With Vulvar Neoplasia-Patient-Reported Outcome (WOMAN-PRO) instrument as a measure of women's post-vulvar surgery symptom experience and informational needs, (b) examine its content validity, (c) describe modifications based on pilot testing, and (d) examine the content validity of the revised instrument.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Currently, observations of space debris are primarily performed with ground-based sensors. These sensors have a detection limit at some centimetres diameter for objects in Low Earth Orbit (LEO) and at about two decimetres diameter for objects in Geostationary Orbit (GEO). The few space-based debris observations stem mainly from in-situ measurements and from the analysis of returned spacecraft surfaces. Both provide information about mostly sub-millimetre-sized debris particles. As a consequence the population of centimetre- and millimetre-sized debris objects remains poorly understood. The development, validation and improvement of debris reference models drive the need for measurements covering the whole diameter range. In 2003 the European Space Agency (ESA) initiated a study entitled “Space-Based Optical Observation of Space Debris”. The first tasks of the study were to define user requirements and to develop an observation strategy for a space-based instrument capable of observing uncatalogued millimetre-sized debris objects. Only passive optical observations were considered, focussing on mission concepts for the LEO, and GEO regions respectively. Starting from the requirements and the observation strategy, an instrument system architecture and an associated operations concept have been elaborated. The instrument system architecture covers the telescope, camera and onboard processing electronics. The proposed telescope is a folded Schmidt design, characterised by a 20 cm aperture and a large field of view of 6°. The camera design is based on the use of either a frame-transfer charge coupled device (CCD), or on a cooled hybrid sensor with fast read-out. A four megapixel sensor is foreseen. For the onboard processing, a scalable architecture has been selected. Performance simulations have been executed for the system as designed, focussing on the orbit determination of observed debris particles, and on the analysis of the object detection algorithms. In this paper we present some of the main results of the study. A short overview of the user requirements and observation strategy is given. The architectural design of the instrument is discussed, and the main tradeoffs are outlined. An insight into the results of the performance simulations is provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE, AIMS AND OBJECTIVES: Heart failure (HF) is a severe chronic disease and impairs health-related quality of life (HRQL). While validated specific HRQL instruments are required for evaluation of treatment and rehabilitation in patients with HF, a single validated measure to document changes in HRQL for patients with different heart disease diagnoses would be invaluable. The purpose of this analysis was the psychometric analysis of the German MacNew Heart Disease Questionnaire (MacNew) in HF patients, which has previously been shown to be reliable and valid in patients with myocardial infarction, angina pectoris and arrhythmia. METHODS: We recruited 89 patients (61.7+/-11.5 years; 84.3% male) in two Austrian and one Swiss cardiology department with documented HF (effect sizes 28.9+/-10.1%). The self-administered MacNew, the Short Form-36 (SF-36) and the Hospital Anxiety and Depression Scale were completed. Internal consistency reliability (Cronbach's alpha), discriminative and evaluative validity were assessed. RESULTS: Cronbach's alpha exceeded 0.80. Each MacNew scale differentiated between patients with and without anxiety (3.9+/-1.0 vs. 5.3+/-0.8, all P<0.001), with and without depression (4.2+/-1.2 vs. 5.2+/-0.9 all P<0.03) and by the SF-36 health transition item (deteriorate=4.39, no change=4.95, improve=5.45, all P<0.02). Evaluative validity was demonstrated with effect sizes >0.70 for a subsample attending a 12-week outpatient rehabilitation programme. CONCLUSIONS: The German language version of the MacNew demonstrates consistently acceptable psychometric properties of reliability, validity and responsiveness in patients with documented HF. Together with previous documentation of reliability, validity and responsive, these findings strengthen the argument for the MacNew as a potential 'core' HRQL measure, at least in the German language.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Perceptual-cognitive impairment after general anaesthesia may affect the ability to reliably report pain severity with the standard visual analog scale (VAS). To minimise these limitations, we developed 'PAULA the PAIN-METER' (PAULA): it has five coloured emoticon faces on the forefront, it is twice as long as a standard VAS scale, and patients use a slider to mark their pain experience. Forty-eight postoperative patients rated descriptive pain terms on PAULA and on a standard VAS immediately after admission and before discharge from the postanaesthesia care unit. Visual acuity was determined before both assessments. The values obtained with PAULA showed less variance than those obtained with the standard VAS, even at the first assessment, where only 23% of the patients had regained their visual acuity. Furthermore, the deviations of the absolute VAS values in individual patients for each descriptive pain term were significantly smaller with PAULA than with the standard VAS.