91 resultados para initial chirp


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: No large clinical end-point trials have been conducted comparing regimens among human immunodeficiency virus type 1-positive persons starting antiretroviral therapy. We examined clinical progression according to initial regimen in the Antiretroviral Therapy Cohort Collaboration, which is based on 12 European and North American cohort studies. METHODS: We analyzed progression to death from any cause and to AIDS or death (AIDS/death), comparing efavirenz (EFV), nevirapine (NVP), nelfinavir, idinavir, ritonavir (RTV), RTV-boosted protease inhibitors (PIs), saquinavir, and abacavir. We also compared nucleoside reverse-transcriptase inhibitor pairs: zidovudine/lamivudine (AZT/3TC), stavudine (D4T)/3TC, D4T/didanosine (DDI), and others. RESULTS: A total of 17,666 treatment-naive patients, 55,622 person-years at risk, 1,617 new AIDS events, and 895 deaths were analyzed. Compared with EFV, the adjusted hazard ratio (HR) for AIDS/death was 1.28 (95% confidence interval [CI], 1.03-1.60) for NVP, 1.31 (95% CI, 1.01-1.71) for RTV, and 1.45 (95% CI, 1.15-1.81) for RTV-boosted PIs. For death, the adjusted HR for NVP was 1.65 (95% CI, 1.16-2.36). The adjusted HR for death for D4T/3TC was 1.35 (95% CI, 1.14-1.59), compared with AZT/3TC. CONCLUSIONS: Outcomes may vary across initial regimens. Results are observational and may have been affected by bias due to unmeasured or residual confounding. There is a need for large, randomized, clinical end-point trials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the primary success and short-term patency associated with a new 4-F sheath-compatible self-expanding nitinol stent after failed conventional angioplasty of distal popliteal and infrapopliteal lesions in severe lifestyle-limiting claudication (LLC) and chronic critical limb ischemia (CLI). MATERIALS AND METHODS: Between May 2003 and July 2005, 35 patients with Rutherford category 3-5 disease (16 patients with CLI, 19 patients with LLC) underwent percutaneous transluminal angioplasty (PTA) and stent implantation. Indications for stent placement were residual stenosis, flow-limiting dissections, or elastic recoil after PTA. Before and after the intervention and during the 6-month follow-up, clinical investigation, color-flow and duplex Doppler ultrasonography, and digital subtraction angiography were performed. Technical success, primary patency at 6 months, clinical improvement as defined by Rutherford with clinical and hemodynamic measures, and complications were evaluated. RESULTS: A total of 22 patients underwent distal popliteal artery stent placement and 13 underwent tibioperoneal artery stent placement. Stent implantation was successfully performed in all patients. After stent placement, the primary cumulative patency rate for the study group at 6 months was 82%. The mean resting ankle-brachial index at baseline was 0.50 +/- 0.16 and significantly increased to 0.90 +/- 0.17 at 12-24 hours after intervention and 0.82 +/- 0.24 at latest follow-up (P < .001 for both). The sustained clinical improvement rate was 80% at the 6-month follow-up. The 6-month limb salvage rate regarding major amputation was 100%. The rate of major complications was 17%. CONCLUSIONS: Infrapopliteal application of the new nitinol stent is a safe, feasible, and effective method with good short-term patency rate in the treatment of severe LLC and chronic CLI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To develop and evaluate a short form of the 24-item Geriatric Pain Measure (GPM) for use in community-dwelling older adults. DESIGN: Derivation and validation of a 12-item version of the GPM in a European and an independent U.S. sample of community-dwelling older adults. SETTING: Three community-dwelling sites in London, United Kingdom; Hamburg, Germany; Solothurn, Switzerland; and two ambulatory geriatrics clinics in Los Angeles, California. PARTICIPANTS: European sample: 1,059 community-dwelling older persons from three sites (London, UK; Hamburg, Germany; Solothurn, Switzerland); validation sample: 50 persons from Los Angeles, California, ambulatory geriatric clinics. MEASUREMENTS: Multidimensional questionnaire including self-reported demographic and clinical information. RESULTS: Based on item-to-total scale correlations in the European sample, 11 of 24 GPM items were selected for inclusion in the short form. One additional item (pain-related sleep problems) was included based on clinical relevance. In the validation sample, the Cronbach alpha of GPM-12 was 0.92 (individual subscale range 0.77-0.92), and the Pearson correlation coefficient (r) between GPM-12 and the original GPM was 0.98. The correlation between the GPM-12 and the McGill Pain Questionnaire was 0.63 (P<.001), similar to the correlation between the original GPM and the McGill Pain Questionnaire (Pearson r=0.63; P<.001). Exploratory factor analysis indicated that the GPM-12 covers three subfactors (pain intensity, pain with ambulation, disengagement because of pain). CONCLUSION: The GPM-12 demonstrated good validity and reliability in these European and U.S. populations of older adults. Despite its brevity, the GPM-12 captures the multidimensional nature of pain in three subscales. The self-administered GPM-12 may be useful in the clinical assessment process and management of pain and in pain-related research in older persons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this randomized, cross-over in situ study was to determine the effects of 4 chewing gums on artificial caries-like subsurface lesions. Two chewing gums (1 with zinc citrate and 1 without) contained dicalcium phosphate (3.9%), calcium gluconate (1.8%) and calcium lactate (0.45%), 1 chewing gum contained casein phosphopeptide-amorphous calcium phosphate nanocomplexes (0.7%), and another one contained no calcium. Fifteen subjects without current caries activity (7 male, 8 female; mean age: 27.5 +/- 2.5 years) wore removable buccal appliances in the lower jaw with 4 bovine enamel slabs with subsurface lesions. The appliances were inserted immediately before gum chewing for 20 min and then retained for an additional 20 min. This was performed 4 times per day. Every subject chewed 4 different chewing gums over 4 periods of 14 days each. During a fifth period (control) the subjects only wore the appliances without chewing gum. At completion of each period the enamel slabs were embedded, sectioned and subjected to transversal microradiography. With regard to change of mineral loss and of lesion depth no significant differences could be found between chewing gums containing calcium and calcium-free chewing gums. Moreover, the chewing gum groups and the control group did not differ significantly if adjustments were made for baseline values (p > 0.05; ANCOVA). Under the conditions of the present study it may be concluded that the use of chewing gum offers no additional remineralizing benefit to buccal tooth surfaces, even if the chewing gum contains calcium compounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One limitation to the widespread implementation of Monte Carlo (MC) patient dose-calculation algorithms for radiotherapy is the lack of a general and accurate source model of the accelerator radiation source. Our aim in this work is to investigate the sensitivity of the photon-beam subsource distributions in a MC source model (with target, primary collimator, and flattening filter photon subsources and an electron subsource) for 6- and 18-MV photon beams when the energy and radial distributions of initial electrons striking a linac target change. For this purpose, phase-space data (PSD) was calculated for various mean electron energies striking the target, various normally distributed electron energy spread, and various normally distributed electron radial intensity distributions. All PSD was analyzed in terms of energy, fluence, and energy fluence distributions, which were compared between the different parameter sets. The energy spread was found to have a negligible influence on the subsource distributions. The mean energy and radial intensity significantly changed the target subsource distribution shapes and intensities. For the primary collimator and flattening filter subsources, the distribution shapes of the fluence and energy fluence changed little for different mean electron energies striking the target, however, their relative intensity compared with the target subsource change, which can be accounted for by a scaling factor. This study indicates that adjustments to MC source models can likely be limited to adjusting the target subsource in conjunction with scaling the relative intensity and energy spectrum of the primary collimator, flattening filter, and electron subsources when the energy and radial distributions of the initial electron-beam change.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The clinical role of CAD systems to detect breast cancer, which have not been on cancer containing mammograms not detected by the radiologist was proven retrospectively. METHODS: All patients from 1992 to 2005 with a histologically verified malignant breast lesion and a mammogram at our department, were analyzed in retrospect focussing on the time of detection of the malignant lesion. All prior mammograms were analyzed by CAD (CADx, USA). The resulting CAD printout was matched with the cancer containing images yielding to the radiological diagnosis of breast cancer. CAD performance, sensitivity as well as the association of CAD and radiological features were analyzed. RESULTS: 278 mammograms fulfilled the inclusion criteria. 111 cases showed a retrospectively visible lesion (71 masses, 23 single microcalcification clusters, 16 masses with microcalcifications, in one case two microcalcification clusters). 54/87 masses and 34/41 microcalcifications were detected by CAD. Detection rates varied from 9/20 (ACR 1) to 5/7 (ACR 4) (45% vs. 71%). The detection of microcalcifications was not influenced by breast tissue density. CONCLUSION: CAD might be useful in an earlier detection of subtle breast cancer cases, which might remain otherwise undetected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this single-center study was to report our initial experience with an implantable remote pressure sensor for aneurysm sac pressure measurement in patients post-endovascular aneurysm repair (EVAR) including short-term follow-up. A pressure sensor (EndoSure, Atlanta, GA) was implanted in 12 patients treated with different commercially available aortic endografts for EVAR. Pressure was read pre- and post-EVAR in the operating room. One-month follow-up (30 days +/- 6 days) was performed including sac pressure readings and IV contrast CT scans. Variables were compared using the paired Student's t test. An intraprocedure type-I endoleak and a type-III endoleak were successfully treated resulting in decreasing sac pressures. In all patients, post-EVAR systolic sac pressure decreased by an average of 33% (P

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To prospectively determine quantitatively and qualitatively the timing of maximal enhancement of the normal small-bowel wall by using contrast material-enhanced multi-detector row computed tomography (CT). MATERIALS AND METHODS: This HIPAA-compliant study was approved by the institutional review board. After information on radiation risk was given, written informed consent was obtained from 25 participants with no history of small-bowel disease (mean age, 58 years; 19 men) who had undergone single-level dynamic CT. Thirty seconds after the intravenous administration of contrast material, a serial dynamic acquisition, consisting of 10 images obtained 5 seconds apart, was performed. Enhancement measurements were obtained over time from the small-bowel wall and the aorta. Three independent readers qualitatively assessed small-bowel conspicuity. Quantitative and qualitative data were analyzed during the arterial phase, the enteric phase (which represented peak small-bowel mural enhancement), and the venous phase. Statistical analysis included paired Student t test and Wilcoxon signed rank test with Bonferroni correction. A P value less than .05 was used to indicate a significant difference. RESULTS: The mean time to peak enhancement of the small-bowel wall was 49.3 seconds +/- 7.7 (standard deviation) and 13.5 seconds +/- 7.6 after peak aortic enhancement. Enhancement values were highest during the enteric phase (P < .05). Regarding small-bowel conspicuity, images obtained during the enteric phase were most preferred qualitatively; there was a significant difference between the enteric and arterial phases (P < .001) but not between the enteric and venous phases (P = .18). CONCLUSION: At multi-detector row CT, peak mural enhancement of the normal small bowel occurs on average about 50 seconds after intravenous administration of contrast material or 14 seconds after peak aortic enhancement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The use of vascular plug devices for the occlusion of high-flow lesions is a relatively new and successful procedure in peripheral and cardiopulmonary interventions. We report on the use and efficiency of the Amplatzer vascular plug in a small clinical series and discuss its potential for occlusion of large vessels and high-flow lesions in neurointerventions. METHODS: Between 2005 and 2007 four patients (mean age 38.5 years, range 16-62 years) were treated with the device, in three patients to achieve parent artery occlusion of the internal carotid artery, in one patient to occlude a high-flow arteriovenous fistula of the neck. The application, time to occlusion, and angiographic and clinical results and the follow-up were evaluated. RESULTS: Navigation, positioning and detachment of the device were satisfactory in all cases. No flow-related migration of the plug was seen. The cessation of flow was delayed by a mean of 10.5 min after deployment of the first device. In the procedures involving vessel sacrifice, two devices had to be deployed to achieve total occlusion. No patient experienced new neurological deficits; the 3-month follow-up revealed stable results. CONCLUSION: The Amplatzer vascular plug can be adapted for the treatment of high-flow lesions and parent artery occlusions in the head and neck. In this small series the use of the devices was uncomplicated and safe. The rigid and large delivery device and the delayed cessation of flow currently limit the device's use in neurointerventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the effect of two pairs of echo times (TEs) for in-phase (IP) and opposed-phase (OP) 3.0-T magnetic resonance (MR) imaging on (a) quantitative analysis prospectively in a phantom study and (b) diagnostic accuracy retrospectively in a clinical study of adrenal tumors, with use of various reference standards in the clinical study. MATERIALS AND METHODS: A fat-saline phantom was used to perform IP and OP 3.0-T MR imaging for various fat fractions. The institutional review board approved this HIPAA-compliant study, with waiver of informed consent. Single-breath-hold IP and OP 3.0-T MR images in 21 patients (14 women, seven men; mean age, 63 years) with 23 adrenal tumors (16 adenomas, six metastases, one adrenocortical carcinoma) were reviewed. The MR protocol involved two acquisition schemes: In scheme A, the first OP echo (approximately 1.5-msec TE) and the second IP echo (approximately 4.9-msec TE) were acquired. In scheme B, the first IP echo (approximately 2.4-msec TE) and the third OP echo (approximately 5.8-msec TE) were acquired. Quantitative analysis was performed, and analysis of variance was used to test for differences between adenomas and nonadenomas. RESULTS: In the phantom study, scheme B did not enable discrimination among voxels that had small amounts of fat. In the clinical study, no overlap in signal intensity (SI) index values between adenomas and nonadenomas was seen (P < .05) with scheme A. However, with scheme B, no overlap in the adrenal gland SI-to-liver SI ratio between adenomas and nonadenomas was seen (P < .05). With scheme B, no overlap in adrenal gland SI index-to-liver SI index ratio between adenomas and nonadenomas was seen (P < .05). CONCLUSION: This initial experience indicates SI index is the most reliable parameter for characterization of adrenal tumors with 3.0-T MR imaging when obtaining OP echo before IP echo. When acquiring IP echo before OP echo, however, nonadenomas can be mistaken as adenomas with use of the SI index value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To prospectively determine if changes in intrarenal oxygenation during acute unilateral ureteral obstruction can be depicted with blood oxygen level-dependent (BOLD) magnetic resonance (MR) imaging. MATERIALS AND METHODS: The study was approved by the local ethics committee, and written informed consent was obtained from all patients. BOLD MR imaging was performed in 10 male patients (mean age, 45 years +/- 17 [standard deviation]; range, 20-73 years) with a distal unilateral ureteral calculus and in 10 healthy age-matched male volunteers to estimate R2*, which is inversely related to tissue Po(2). R2* values were determined in the cortex and medulla of the obstructed and the contralateral nonobstructed kidneys. To reduce external effects on R2*, the R2* ratio between the medulla and cortex was also analyzed. Statistical analysis was performed with nonparametric rank tests. P < .05 was considered to indicate a significant difference. RESULTS: All patients had significantly lower medullary and cortical R2* values in the obstructed kidney (median R2* in medulla, 10.9 sec(-1) [range, 9.1-14.3 sec(-1)]; median R2* in cortex, 10.4 sec(-1) [range, 9.7-11.3 sec(-1)]) than in the nonobstructed kidney (median R2* in medulla, 17.2 sec(-1) [range, 14.6-23.2 sec(-1)], P = .005; median R2* in cortex, 11.7 sec(-1) [range, 11.0-14.0 sec(-1)], P = .005); values in the obstructed kidneys were also significantly lower than values in the kidneys of healthy control subjects (median R2* in medulla, 16.1 sec(-1) [range, 13.9-18.1 sec(-1)], P < .001; median R2* in cortex, 11.6 sec(-1) [range, 10.5-12.9 sec(-1)], P < .001). R2* ratios in the obstructed kidneys (median, 1.06; range, 0.85-1.27) were significantly lower than those in the nonobstructed kidneys (median, 1.49; range, 1.26-1.71; P = .005) and those in the kidneys of healthy control subjects (median, 1.38; range, 1.23-1.47; P < .001). In contrast, R2* ratios in the nonobstructed kidneys of patients were significantly higher than those in kidneys of healthy control subjects (P = .01). CONCLUSION: Increased oxygen content in the renal cortex and medulla occurs with acute unilateral ureteral obstruction, suggesting reduced function of the affected kidney.