42 resultados para incompleteness and inconsistency detection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Newborns with hypoplastic left heart syndrome (HLHS) or right heart syndrome or other malformations with a single ventricle physiology and associated hypoplasia of the great arteries continue to be a challenge in terms of survival. The vast majority of these forms of congenital heart defects relate to abnormal morphogenesis during early intrauterine development and can be diagnosed accurately by fetal echocardiography. Early knowledge of these conditions not only permits a better understanding of the progression of these malformations but encourages some researchers to explore new minimally invasive therapeutic options with a view to early pre- and postnatal cardiac palliation. DATA SOURCES: PubMed database was searched with terms of "congenital heart defects", "fetal echocardiography" and "neonatal cardiac surgery". RESULTS: At present, early prenatal detection has been applied for monitoring pregnancy to avoid intrauterine cardiac decompensation. In principle, the majority of congenital heart defects can be diagnosed by prenatal echocardiography and the detection rate is 85%-95% at tertiary perinatal centers. The majority, particularly of complex congenital lesions, show a steadily progressive course including subsequent secondary phenomena such as arrhythmias or myocardial insufficiency. So prenatal treatment of an abnormal fetus is an area of perinatal medicine that is undergoing a very dynamic development. Early postnatal treatment is established for some time, and prenatal intervention or palliation is at its best experimental stage in individual cases. CONCLUSION: The upcoming expansion of fetal cardiac intervention to ameliorate critically progressive fetal lesions intensifies the need to address issues about the adequacy of technological assessment and patient selection as well as the morbidity of those who undergo these procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PCR tests for the rapid and valid detection of methicillin-resistant Staphylococcus aureus (MRSA) are now available. We evaluated the costs associated with contact screening for MRSA carriage in a tertiary-care hospital with low MRSA endemicity. Between 1 October 2005 and 28 February 2006, 232 patients were screened during 258 screening episodes (644 samples) for MRSA carriage by GenoType MRSA Direct (Hain Lifescience GmbH, Nehren, Germany). Conventional culture confirmed all PCR results. According to in-house algorithms, 34 of 258 screening episodes (14.7%) would have qualified for preemptive contact isolation, but such isolation was not done upon negative PCR results. MRSA carriage was detected in 4 (1.5%) of 258 screening episodes (i.e., in four patients), of which none qualified for preemptive contact isolation. The use of PCR for all 258 screening episodes added costs (in Swiss francs [CHF]) of CHF 104,328.00 and saved CHF 38,528.00 (for preemptive isolation). The restriction of PCR screening to the 34 episodes that qualified for preemptive contact isolation and screening all others by culture would have lowered costs for PCR to only CHF 11,988.00, a savings of CHF 38,528.00. Therefore, PCR tests are valuable for the rapid detection of MRSA carriers, but high costs require the careful evaluation of their use. In patient populations with low MRSA endemicity, the broad use of PCR probably is not cost-effective.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aquatic toxicology is facing the challenge to assess the impact of complex mixtures of compounds on diverse biological endpoints. So far, ecotoxicology focuses mainly on apical endpoints such as growth, lethality and reproduction, but does not consider sublethal toxic effects that may indirectly cause ecological effects. One such sublethal effect is toxicant-induced impairment of neurosensory functions which will affect important behavioural traits of exposed organisms. Here, we critically review the mechanosensory lateral line (LL) system of zebrafish as a model to screen for chemical effects on neurosensory function of fish in particular and vertebrates in general. The LL system consists of so-called neuromasts, composed of centrally located sensory hair cells, and surrounding supporting cells. The function of neuromasts is the detection of water movements that is essential for the fish's ability to detect prey, to escape predator, to socially interact or to show rheotactic behaviour. Recent advances in the study of these organs provided researchers with a broad area of molecular tools for easy and rapid detection of neuromasts dysfunction and/or disturbed development. Further, genes involved in neuromasts differentiation have been identified using auditory/mechanosensory mutants and morphants. A number of environmental toxicants including metals and pharmaceuticals have been shown to affect neuromasts development and/or function. The use of the LL organ for toxicological studies offers the advantage to integrate the available profound knowledge on developmental biology of the neuromasts with the study of chemical toxicity. This combination may provide a powerful tool in environmental risk assessment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES Mortality in patients starting antiretroviral therapy (ART) is higher in Malawi and Zambia than in South Africa. We examined whether different monitoring of ART (viral load [VL] in South Africa and CD4 count in Malawi and Zambia) could explain this mortality difference. DESIGN Mathematical modelling study based on data from ART programmes. METHODS We used a stochastic simulation model to study the effect of VL monitoring on mortality over 5 years. In baseline scenario A all parameters were identical between strategies except for more timely and complete detection of treatment failure with VL monitoring. Additional scenarios introduced delays in switching to second-line ART (scenario B) or higher virologic failure rates (due to worse adherence) when monitoring was based on CD4 counts only (scenario C). Results are presented as relative risks (RR) with 95% prediction intervals and percent of observed mortality difference explained. RESULTS RRs comparing VL with CD4 cell count monitoring were 0.94 (0.74-1.03) in scenario A, 0.94 (0.77-1.02) with delayed switching (scenario B) and 0.80 (0.44-1.07) when assuming a 3-times higher rate of failure (scenario C). The observed mortality at 3 years was 10.9% in Malawi and Zambia and 8.6% in South Africa (absolute difference 2.3%). The percentage of the mortality difference explained by VL monitoring ranged from 4% (scenario A) to 32% (scenarios B and C combined, assuming a 3-times higher failure rate). Eleven percent was explained by non-HIV related mortality. CONCLUSIONS VL monitoring reduces mortality moderately when assuming improved adherence and decreased failure rates.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Little is known about the potential benefit of skin self-examination for melanoma prevention and early detection. Objectives: To determine whether skin self-examination is associated with reduced melanoma risk, self-detection of tumours, and reduced risk of deeper melanomas. METHODS We used data from a population-based case-control study (423 cases, 678 controls) to assess recent skin self-examination in relation to self-detection, melanoma risk and tumour depth ( ≤1 mm; > 1 mm). Logistic regression was used to estimate odds ratios (ORs) and confidence intervals (CIs) for associations of interest. RESULTS Skin self-examination conducted 1-11 times during a recent year was associated with a possible decrease in melanoma risk (OR 0·74; 95% CI 0·54-1·02). Melanoma risk was decreased for those who conducted skin self-examination and saw a doctor (OR 0·52; 95% CI 0·30-0·90). Among cases, those who examined their skin were twice as likely to self-detect the melanoma (OR 2·23; 95% CI 1·47-3·38), but self-detection was not associated with shallower tumours. Tumour depth was reduced for those who conducted skin self-examination 1-11 times during a recent year (OR 0·39; 95% CI 0·18-0·81), but was not influenced by seeing a doctor, or by conducting skin self-examination and seeing a doctor. CONCLUSIONS Risk of a deeper tumour and possibly risk of melanoma were reduced by skin self-examination 1-11 times annually. Melanoma risk was markedly reduced by skin self-examination coupled with a doctor visit. We cannot, however, exclude the possibility that our findings reflect bias or confounding. Additional studies are needed to elucidate the potential benefits of skin self-examination for melanoma prevention and early detection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES To synthesise the available evidence on pharmacological and non-pharmacological interventions recommended for fibromyalgia syndrome (FMS). METHODS Electronic databases including MEDLINE, PsycINFO, Scopus, the Cochrane Controlled Trials Registry and the Cochrane Library were searched for randomised controlled trials comparing any therapeutic approach as recommended in FMS guidelines (except complementary and alternative medicine) with control interventions in patients with FMS. Primary outcomes were pain and quality of life. Data extraction was done using standardised forms. RESULTS 102 trials in 14 982 patients and eight active interventions (tricyclic antidepressants, selective serotonin reuptake inhibitors, serotonin noradrenaline reuptake inhibitors (SNRIs), the gamma-amino butyric acid analogue pregabalin, aerobic exercise, balneotherapy, cognitive behavioural therapy (CBT), multicomponent therapy) were included. Most of the trials were small and hampered by methodological quality, introducing heterogeneity and inconsistency in the network. When restricted to large trials with ≥100 patients per group, heterogeneity was low and benefits for SNRIs and pregabalin compared with placebo were statistically significant, but small and not clinically relevant. For non-pharmacological interventions, only one large trial of CBT was available. In medium-sized trials with ≥50 patients per group, multicomponent therapy showed small to moderate benefits over placebo, followed by aerobic exercise and CBT. CONCLUSIONS Benefits of pharmacological treatments in FMS are of questionable clinical relevance and evidence for benefits of non-pharmacological interventions is limited. A combination of pregabalin or SNRIs as pharmacological interventions and multicomponent therapy, aerobic exercise and CBT as non-pharmacological interventions seems most promising for the management of FMS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Amylase activity in exhaled breath condensate (EBC) is usually interpreted as an indication of oropharyngeal contamination despite the fact that amylase can be found in pulmonary excretions. The aim of this study was to recruit and refine an amylase assay in order to detect amylase activity in any EBC sample and to develop a method to identify EBC samples containing amylase of pulmonary origin. EBC was collected from 40 volunteers with an EcoScreen condenser. Amylase assays and methods to discriminate between oropharyngeal and pulmonary proteins were tested and developed using matched EBC and saliva samples. Our refined 2-chloro-4-nitrophenyl-α-D-maltotriosid (CNP-G3) assay was 40-fold more sensitive than the most sensitive commercial assay and allowed detection of amylase activity in 30 µl of EBC. We developed a dot-blot assay which allowed detection of salivary protein in saliva diluted up to 150 000-fold. By plotting amylase activity against staining intensity we identified a few EBC samples with high amylase activity which were aligned with diluted saliva. We believe that EBC samples aligned with diluted saliva contain amylase activity introduced during EBC collection and that all other EBC samples contain amylase activity of pulmonary origin and are basically free of oropharyngeal protein contamination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two proton accelerators have been recently put in operation in Bern: an 18 MeV cyclotron and a 2 MeV RFQ linac. The commercial IBA 18/18 cyclotron, equipped with a specifically conceived 6 m long external beam line ending in a separate bunker, will provide beams for routine 18-F and other PET radioisotope production as well as for novel detector, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. The accelerator is embedded into a complex building hosting two physics laboratories and four Good Manufacturing Practice (GMP) laboratories. This project is the result of a successful collaboration between the Inselspital, the University of Bern and private investors, aiming at the constitution of a combined medical and research centre able to provide the most cutting-edge technologies in medical imaging and cancer radiation therapy. The cyclotron is complemented by the RFQ with the primary goals of elemental analysis via Particle Induced Gamma Emission (PIGE), and the detection of potentially dangerous materials with high nitrogen content using the Gamma-Resonant Nuclear Absorption (GRNA) technique. In this context, beam instrumentation devices have been developed, in particular an innovative beam profile monitor based on doped silica fibres and a setup for emittance measurements using the pepper-pot technique. On this basis, the establishment of a proton therapy centre on the campus of the Inselspital is in the phase of advanced study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE (99)TC combined with blue-dye mapping is considered the best sentinel lymph node (SLN) mapping technique in cervical cancer. Indocyanine green (ICG) with near infrared fluorescence imaging has been introduced as a new methodology for SLN mapping. The aim of this study was to compare these two techniques in the laparoscopic treatment of cervical cancer. METHODS Medical records of patients undergoing laparoscopic SLN mapping for cervical cancer with either (99)Tc and patent blue dye (Group 1) or ICG (Group 2) from April 2008 until August 2012 were reviewed. Sensitivity, specificity, and overall and bilateral detection rates were calculated and compared. RESULTS Fifty-eight patients were included in the study-36 patients in Group 1 and 22 patients in Group 2. Median tumor diameter was 25 and 29 mm, and mean SLN count was 2.1 and 3.7, for Groups 1 and 2, respectively. Mean non-SLN (NSLN) count was 39 for both groups. SLNs were ninefold more likely to be affected by metastatic disease compared with NSLNs (p < 0.005). Sensitivity and specificity were both 100 %. Overall detection rates were 83 and 95.5 % (p = nonsignificant), and bilateral detection rates were 61 and 95.5 % (p < 0.005), for Groups 1 and 2, respectively. In 75 % of cases, SLNs were located along the external or internal iliac nodal basins. CONCLUSIONS ICG SLN mapping in cervical cancer provides high overall and bilateral detection rates that compare favorably with the current standard of care.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: In team sports the ability to use peripheral vision is essential to track a number of players and the ball. By using eye-tracking devices it was found that players either use fixations and saccades to process information on the pitch or use smooth pursuit eye movements (SPEM) to keep track of single objects (Schütz, Braun, & Gegenfurtner, 2011). However, it is assumed that peripheral vision can be used best when the gaze is stable while it is unknown whether motion changes can be equally well detected when SPEM are used especially because contrast sensitivity is reduced during SPEM (Schütz, Delipetkose, Braun, Kerzel, & Gegenfurtner, 2007). Therefore, peripheral motion change detection will be examined by contrasting a fixation condition with a SPEM condition. Methods: 13 participants (7 male, 6 female) were presented with a visual display consisting of 15 white and 1 red square. Participants were instructed to follow the red square with their eyes and press a button as soon as a white square begins to move. White square movements occurred either when the red square was still (fixation condition) or moving in a circular manner with 6 °/s (pursuit condition). The to-be-detected white square movements varied in eccentricity (4 °, 8 °, 16 °) and speed (1 °/s, 2 °/s, 4 °/s) while movement time of white squares was constant at 500 ms. 180 events should be detected in total. A Vicon-integrated eye-tracking system and a button press (1000 Hz) was used to control for eye-movements and measure detection rates and response times. Response times (ms) and missed detections (%) were measured as dependent variables and analysed with a 2 (manipulation) x 3 (eccentricity) x 3 (speed) ANOVA with repeated measures on all factors. Results: Significant response time effects were found for manipulation, F(1,12) = 224.31, p < .01, ηp2 = .95, eccentricity, F(2,24) = 56.43; p < .01, ηp2 = .83, and the interaction between the two factors, F(2,24) = 64.43; p < .01, ηp2 = .84. Response times increased as a function of eccentricity for SPEM only and were overall higher than in the fixation condition. Results further showed missed events effects for manipulation, F(1,12) = 37.14; p < .01, ηp2 = .76, eccentricity, F(2,24) = 44.90; p < .01, ηp2 = .79, the interaction between the two factors, F(2,24) = 39.52; p < .01, ηp2 = .77 and the three-way interaction manipulation x eccentricity x speed, F(2,24) = 3.01; p = .03, ηp2 = .20. While less than 2% of events were missed on average in the fixation condition as well as at 4° and 8° eccentricity in the SPEM condition, missed events increased for SPEM at 16 ° eccentricity with significantly more missed events in the 4 °/s speed condition (1 °/s: M = 34.69, SD = 20.52; 2 °/s: M = 33.34, SD = 19.40; 4 °/s: M = 39.67, SD = 19.40). Discussion: It could be shown that using SPEM impairs the ability to detect peripheral motion changes at the far periphery and that fixations not only help to detect these motion changes but also to respond faster. Due to high temporal constraints especially in team sports like soccer or basketball, fast reaction are necessary for successful anticipation and decision making. Thus, it is advised to anchor gaze at a specific location if peripheral changes (e.g. movements of other players) that require a motor response have to be detected. In contrast, SPEM should only be used if a single object, like the ball in cricket or baseball, is necessary for a successful motor response. References: Schütz, A. C., Braun, D. I., & Gegenfurtner, K. R. (2011). Eye movements and perception: A selective review. Journal of Vision, 11, 1-30. Schütz, A. C., Delipetkose, E., Braun, D. I., Kerzel, D., & Gegenfurtner, K. R. (2007). Temporal contrast sensitivity during smooth pursuit eye movements. Journal of Vision, 7, 1-15.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Non-steroidal anti-inflammatory drugs (NSAIDs) are the backbone of osteoarthritis pain management. We aimed to assess the effectiveness of different preparations and doses of NSAIDs on osteoarthritis pain in a network meta-analysis. METHODS For this network meta-analysis, we considered randomised trials comparing any of the following interventions: NSAIDs, paracetamol, or placebo, for the treatment of osteoarthritis pain. We searched the Cochrane Central Register of Controlled Trials (CENTRAL) and the reference lists of relevant articles for trials published between Jan 1, 1980, and Feb 24, 2015, with at least 100 patients per group. The prespecified primary and secondary outcomes were pain and physical function, and were extracted in duplicate for up to seven timepoints after the start of treatment. We used an extension of multivariable Bayesian random effects models for mixed multiple treatment comparisons with a random effect at the level of trials. For the primary analysis, a random walk of first order was used to account for multiple follow-up outcome data within a trial. Preparations that used different total daily dose were considered separately in the analysis. To assess a potential dose-response relation, we used preparation-specific covariates assuming linearity on log relative dose. FINDINGS We identified 8973 manuscripts from our search, of which 74 randomised trials with a total of 58 556 patients were included in this analysis. 23 nodes concerning seven different NSAIDs or paracetamol with specific daily dose of administration or placebo were considered. All preparations, irrespective of dose, improved point estimates of pain symptoms when compared with placebo. For six interventions (diclofenac 150 mg/day, etoricoxib 30 mg/day, 60 mg/day, and 90 mg/day, and rofecoxib 25 mg/day and 50 mg/day), the probability that the difference to placebo is at or below a prespecified minimum clinically important effect for pain reduction (effect size [ES] -0·37) was at least 95%. Among maximally approved daily doses, diclofenac 150 mg/day (ES -0·57, 95% credibility interval [CrI] -0·69 to -0·46) and etoricoxib 60 mg/day (ES -0·58, -0·73 to -0·43) had the highest probability to be the best intervention, both with 100% probability to reach the minimum clinically important difference. Treatment effects increased as drug dose increased, but corresponding tests for a linear dose effect were significant only for celecoxib (p=0·030), diclofenac (p=0·031), and naproxen (p=0·026). We found no evidence that treatment effects varied over the duration of treatment. Model fit was good, and between-trial heterogeneity and inconsistency were low in all analyses. All trials were deemed to have a low risk of bias for blinding of patients. Effect estimates did not change in sensitivity analyses with two additional statistical models and accounting for methodological quality criteria in meta-regression analysis. INTERPRETATION On the basis of the available data, we see no role for single-agent paracetamol for the treatment of patients with osteoarthritis irrespective of dose. We provide sound evidence that diclofenac 150 mg/day is the most effective NSAID available at present, in terms of improving both pain and function. Nevertheless, in view of the safety profile of these drugs, physicians need to consider our results together with all known safety information when selecting the preparation and dose for individual patients. FUNDING Swiss National Science Foundation (grant number 405340-104762) and Arco Foundation, Switzerland.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The improvement and performance of a micellar electrokinetic capillary chromatography assay for cefepime in human serum and plasma with a 50 μm id fused-silica capillary elongated from 40 to 60 cm is reported. Sample preparation with dodecylsulfate protein precipitation at pH 4.5, the pH 9.1 separation medium and the applied voltage were as reported previously[16]. The change resulted in a significant lower current, higher resolution and increased detection time intervals. The performance of the assay with multi-level internal calibration was assessed with calibration and control samples. Quality assurance data of a two year period assessed under the new conditions demonstrated the robustness of the assay. In serum samples of patients who received both cefepime and sulfamethoxazole, cefepime could not be detected due to the inseparability of the two compounds. The presence of an interference can be recognized by an increased peak width (width > 0.2 min), the appearance of a shoulder or an unresolved double peak. The patient data gathered during a three year period reveal that introduction of therapeutic drug monitoring led to a 50% reduction of the median drug level. The data suggest that therapeutic drug monitoring can help to minimize the risk of major adverse reactions and to increase drug safety on an individual basis. This article is protected by copyright. All rights reserved.