40 resultados para health technology assessment
Resumo:
PURPOSE The objective of this study was to assess the risk of bias of randomized controlled trials (RCTs) published in prosthodontic and implant dentistry journals. MATERIALS AND METHODS The last 30 issues of 9 journals in the field of prosthodontic and implant dentistry (Clinical Implant Dentistry and Related Research, Clinical Oral Implants Research, Implant Dentistry, International Journal of Oral & Maxillofacial Implants, International Journal of Periodontics and Restorative Dentistry, International Journal of Prosthodontics, Journal of Dentistry, Journal of Oral Rehabilitation, and Journal of Prosthetic Dentistry) were hand-searched for RCTs. Risk of bias was assessed using the Cochrane Collaboration's risk of bias tool and analyzed descriptively. RESULTS From the 3,667 articles screened, a total of 147 RCTs were identified and included. The number of published RCTs increased with time. The overall distribution of a high risk of bias assessment varied across the domains of the Cochrane risk of bias tool: 8% for random sequence generation, 18% for allocation concealment, 41% for masking, 47% for blinding of outcome assessment, 7% for incomplete outcome data, 12% for selective reporting, and 41% for other biases. CONCLUSION The distribution of high risk of bias for RCTs published in the selected prosthodontic and implant dentistry journals varied among journals and ranged from 8% to 47%, which can be considered as substantial.
Resumo:
BACKGROUND Arrhythmias in cardiac amyloidosis (CA) result in significant comorbidity and mortality but have not been well characterized. OBJECTIVE The purpose of this study was to define intracardiac conduction, atrial arrhythmia substrate, and ablation outcomes in a group of advanced CA patients referred for electrophysiologic study. METHODS Electrophysiologic study with or without catheter ablation was performed in 18 CA patients. Findings and catheter ablation outcomes were compared to age- and gender-matched non-CA patients undergoing catheter ablation of persistent atrial fibrillation (AF). RESULTS Supraventricular tachycardias were seen in all 18 CA patients (1 AV nodal reentrant tachycardia, 17 persistent atrial tachycardia [AT]/AF). The HV interval was prolonged (>55 ms) in all CA patients, including 6 with normal QRS duration (≤100 ms). Thirteen supraventricular tachycardia ablations were performed in 11 patients. Of these, 7 underwent left atrial (LA) mapping and ablation for persistent AT/AF. Compared to non-CA age-matched comparator AF patients, CA patients had more extensive areas of low-voltage areas LA (63% ± 22% vs 34% ± 22%, P = .009) and a greater number of inducible ATs (3.3 ± 1.9 ATs vs 0.2 ± 0.4 ATs, P <.001). The recurrence rate for AT/AF 1 year after ablation was greater in CA patients (83% vs 25%), and the hazard ratio for postablation AT/AF recurrence in CA patients was 5.4 (95% confidence interval 1.9-35.5, P = .007). CONCLUSION In this group of patients with advanced CA and atrial arrhythmias, there was extensive conduction system disease and LA endocardial voltage abnormality. Catheter ablation persistent AT/AF in advanced CA was associated with a high recurrence rate and appears to have a limited role in control of these arrhythmias.
Resumo:
This paper presents a novel technique to create a computerized fluoroscopy with zero-dose image updates for computer-assisted fluoroscopy-based close reduction and osteosynthesis of diaphyseal fracture of femurs. With the novel technique, repositioning of bone fragments during close fracture reduction will lead to image updates in each acquired imaging plane, which is equivalent to using several fluoroscopes simultaneously from different directions but without any X-ray radiation. Its application facilitates the whole fracture reduction and osteosynthesis procedure when combining with the existing leg length and antetorsion restoration methods and may result in great reduction of the X-ray radiation to the patient and to the surgical team. In this paper, we present the approach for achieving such a technique and the experimental results with plastic bones.
Resumo:
This paper presents a system for 3-D reconstruction of a patient-specific surface model from calibrated X-ray images. Our system requires two X-ray images of a patient with one acquired from the anterior-posterior direction and the other from the axial direction. A custom-designed cage is utilized in our system to calibrate both images. Starting from bone contours that are interactively identified from the X-ray images, our system constructs a patient-specific surface model of the proximal femur based on a statistical model based 2D/3D reconstruction algorithm. In this paper, we present the design and validation of the system with 25 bones. An average reconstruction error of 0.95 mm was observed.
Resumo:
Radon plays an important role for human exposure to natural sources of ionizing radiation. The aim of this article is to compare two approaches to estimate mean radon exposure in the Swiss population: model-based predictions at individual level and measurement-based predictions based on measurements aggregated at municipality level. A nationwide model was used to predict radon levels in each household and for each individual based on the corresponding tectonic unit, building age, building type, soil texture, degree of urbanization, and floor. Measurement-based predictions were carried out within a health impact assessment on residential radon and lung cancer. Mean measured radon levels were corrected for the average floor distribution and weighted with population size of each municipality. Model-based predictions yielded a mean radon exposure of the Swiss population of 84.1 Bq/m(3) . Measurement-based predictions yielded an average exposure of 78 Bq/m(3) . This study demonstrates that the model- and the measurement-based predictions provided similar results. The advantage of the measurement-based approach is its simplicity, which is sufficient for assessing exposure distribution in a population. The model-based approach allows predicting radon levels at specific sites, which is needed in an epidemiological study, and the results do not depend on how the measurement sites have been selected.
Resumo:
Patients with amnestic mild cognitive impairment are at high risk for developing Alzheimer's disease. Besides episodic memory dysfunction they show deficits in accessing contextual knowledge that further specifies a general spatial navigation task or an executive function (EF) virtual action planning. There has been only one previous work with virtual reality and the use of a virtual action planning supermarket for the diagnosis of mild cognitive impairment. The authors of that study examined the feasibility and the validity of the virtual action planning supermarket (VAP-S) for the diagnosis of patients with mild cognitive impairment (MCI) and found that the VAP-S is a viable tool to assess EF deficits. In our study we employed the in-house platform of virtual action planning museum (VAP-M) and a sample of 25 MCI and 25 controls, in order to investigate deficits in spatial navigation, prospective memory and executive function. In addition, we used the morphology of late components in event-related potential (ERP) responses, as a marker for cognitive dysfunction. The related measurements were fed to a common classification scheme facilitating the direct comparison of both approaches. Our results indicate that both the VAP-M and ERP averages were able to differentiate between healthy elders and patients with amnestic mild cognitive impairment and agree with the findings of the virtual action planning supermarket (VAP-S). The sensitivity (specificity) was 100% (98%) for the VAP-M data and 87%(90%) for the ERP responses. Considering that ERPs have proven to advance the early detection and diagnosis of "presymptomatic AD", the suggested VAP-M platform appears as an appealing alternative.
Resumo:
The Personal Health Assistant Project (PHA) is a pilot system implementation sponsored by the Kozani Region Governors’ Association (KRGA) and installed in one of the two major public hospitals of the city of Kozani. PHA is intended to demonstrate how a secure, networked, multipurpose electronic health and food benefits digital signage system can transform common TV sets inside patient homes or hospital rooms into health care media players and facilitate information sharing and improve administrative efficiency among private doctors, public health care providers, informal caregivers, and nutrition program private companies, while placing individual patients firmly in control of the information at hand. This case evaluation of the PHA demonstration is intended to provide critical information to other decision makers considering implementing PHA or related digital signage technology at other institutions and public hospitals around the globe.
Resumo:
The unique characteristics of special populations such as pre-school children and Down syndrome kids in crisis and their distorted self-image were never studied before, because of the difficulty of crisis reproduction. This study proposes a VR setting that tries to model some special population's behaviour in the time of crises and offers them a training scenario. The sample population consisted of 30 pre-school children and 20 children with Down syndrome. The VR setting involved a high-speed PC, a VPL EyePhone 1, a MR toolkit, a vibrations plate, a motion capture system and other sensors. The system measured and modelled the typical behaviour of these special populations in a Virtual Earthquake scenario with sight and sound and calculated a VR anthropomorphic model that reproduced their behaviour and emotional state. Afterwards one group received an emotionally enhanced VR self-image as feedback for their training, one group received a plain VR self-image and another group received verbal instructions. The findings strongly suggest that the training was a lot more biased by the emotionally enhanced VR self-image than the other approaches. These findings could highlight the special role of the self-image to therapy and training and the interesting role of imagination to emotions, motives and learning. Further studies could be done with various scenarios in order to measure the best-biased behaviour and establish the most natural and affective VR model. This presentation is going to highlight the main findings and some theories behind them.
Resumo:
Despite ubiquitous digitisation and the advent of Digital Rights Management Systems, it seems that collecting societies are not quite yet six feet under. Even in a world of rapid technological developments collecting societies will keep providing services to authors, users and the public facilitating the management of rights and performing additionally certain important social and cultural functions. However, agreeing on the future of collecting societies and on the particular design of both individual and collective rights administration is not an easy task and the opinions of the major stakeholders are diverse and often conflicting.