67 resultados para eterogeneità, texture, analysis, CT, perfusionale, tumore


Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To prospectively determine quantitatively and qualitatively the timing of maximal enhancement of the normal small-bowel wall by using contrast material-enhanced multi-detector row computed tomography (CT). MATERIALS AND METHODS: This HIPAA-compliant study was approved by the institutional review board. After information on radiation risk was given, written informed consent was obtained from 25 participants with no history of small-bowel disease (mean age, 58 years; 19 men) who had undergone single-level dynamic CT. Thirty seconds after the intravenous administration of contrast material, a serial dynamic acquisition, consisting of 10 images obtained 5 seconds apart, was performed. Enhancement measurements were obtained over time from the small-bowel wall and the aorta. Three independent readers qualitatively assessed small-bowel conspicuity. Quantitative and qualitative data were analyzed during the arterial phase, the enteric phase (which represented peak small-bowel mural enhancement), and the venous phase. Statistical analysis included paired Student t test and Wilcoxon signed rank test with Bonferroni correction. A P value less than .05 was used to indicate a significant difference. RESULTS: The mean time to peak enhancement of the small-bowel wall was 49.3 seconds +/- 7.7 (standard deviation) and 13.5 seconds +/- 7.6 after peak aortic enhancement. Enhancement values were highest during the enteric phase (P < .05). Regarding small-bowel conspicuity, images obtained during the enteric phase were most preferred qualitatively; there was a significant difference between the enteric and arterial phases (P < .001) but not between the enteric and venous phases (P = .18). CONCLUSION: At multi-detector row CT, peak mural enhancement of the normal small bowel occurs on average about 50 seconds after intravenous administration of contrast material or 14 seconds after peak aortic enhancement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: To evaluate the effect of a modified abdominal multislice computed tomography (CT) protocol for obese patients on image quality and radiation dose. MATERIALS AND METHODS: An adult female anthropomorphic phantom was used to simulate obese patients by adding one or two 4-cm circumferential layers of fat-equivalent material to the abdominal portion. The phantom was scanned with a subcutaneous fat thickness of 0, 4, and 8 cm using the following parameters (detector configuration/beam pitch/table feed per rotation/gantry rotation time/kV/mA): standard protocol A: 16 x 0.625 mm/1.75/17.5 mm/0.5 seconds/140/380, and modified protocol B: 16 x 1.25 mm/1.375/27.5 mm/1.0 seconds/140/380. Radiation doses to six abdominal organs and the skin, image noise values, and contrast-to-noise ratios (CNRs) were analyzed. Statistical analysis included analysis of variance, Wilcoxon rank sum, and Student's t-test (P < .05). RESULTS: Applying the modified protocol B with one or two fat rings, the image noise decreased significantly (P < .05), and simultaneously, the CNR increased significantly compared with protocol A (P < .05). Organ doses significantly increased, up to 54.7%, comparing modified protocol B with one fat ring to the routine protocol A with no fat rings (P < .05). However, no significant change in organ dose was seen for protocol B with two fat rings compared with protocol A without fat rings (range -2.1% to 8.1%) (P > .05). CONCLUSIONS: Using a modified abdominal multislice CT protocol for obese patients with 8 cm or more of subcutaneous fat, image quality can be substantially improved without a significant increase in radiation dose to the abdominal organs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To prospectively evaluate, for the depiction of simulated hypervascular liver lesions in a phantom, the effect of a low tube voltage, high tube current computed tomographic (CT) technique on image noise, contrast-to-noise ratio (CNR), lesion conspicuity, and radiation dose. MATERIALS AND METHODS: A custom liver phantom containing 16 cylindric cavities (four cavities each of 3, 5, 8, and 15 mm in diameter) filled with various iodinated solutions to simulate hypervascular liver lesions was scanned with a 64-section multi-detector row CT scanner at 140, 120, 100, and 80 kVp, with corresponding tube current-time product settings at 225, 275, 420, and 675 mAs, respectively. The CNRs for six simulated lesions filled with different iodinated solutions were calculated. A figure of merit (FOM) for each lesion was computed as the ratio of CNR2 to effective dose (ED). Three radiologists independently graded the conspicuity of 16 simulated lesions. An anthropomorphic phantom was scanned to evaluate the ED. Statistical analysis included one-way analysis of variance. RESULTS: Image noise increased by 45% with the 80-kVp protocol compared with the 140-kVp protocol (P < .001). However, the lowest ED and the highest CNR were achieved with the 80-kVp protocol. The FOM results indicated that at a constant ED, a reduction of tube voltage from 140 to 120, 100, and 80 kVp increased the CNR by factors of at least 1.6, 2.4, and 3.6, respectively (P < .001). At a constant CNR, corresponding reductions in ED were by a factor of 2.5, 5.5, and 12.7, respectively (P < .001). The highest lesion conspicuity was achieved with the 80-kVp protocol. CONCLUSION: The CNR of simulated hypervascular liver lesions can be substantially increased and the radiation dose reduced by using an 80-kVp, high tube current CT technique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To prospectively determine the accuracy of 64-section computed tomographic (CT) angiography for the depiction of coronary artery disease (CAD) that induces perfusion defects at myocardial perfusion imaging with single photon emission computed tomography (SPECT), by using myocardial perfusion imaging as the reference standard. MATERIALS AND METHODS: All patients gave written informed consent after the study details, including radiation exposure, were explained. The study protocol was approved by the local institutional review board. In patients referred for elective conventional coronary angiography, an additional 64-section CT angiography study and a myocardial perfusion imaging study (1-day adenosine stress-rest protocol) with technetium 99m-tetrofosmin SPECT were performed before conventional angiography. Coronary artery diameter narrowing of 50% or greater at CT angiography was defined as stenosis and was compared with the myocardial perfusion imaging findings. Quantitative coronary angiography served as a reference standard for CT angiography. RESULTS: A total of 1093 coronary segments in 310 coronary arteries in 78 patients (mean age, 65 years +/- 9 [standard deviation]; 35 women) were analyzed. CT angiography revealed stenoses in 137 segments (13%) corresponding to 91 arteries (29%) in 46 patients (59%). SPECT revealed 14 reversible, 13 fixed, and six partially reversible defects in 31 patients (40%). Sensitivity, specificity, and negative and positive predictive values, respectively, of CT angiography in the detection of reversible myocardial perfusion imaging defects were 95%, 53%, 94%, and 58% on a per-patient basis and 95%, 75%, 96%, and 72% on a per-artery basis. Agreement between CT and conventional angiography was very good (96% and kappa = 0.92 for patient-based analysis, 93% and kappa = 0.84 for vessel-based analysis). CONCLUSION: Sixty-four-section CT angiography can help rule out hemodynamically relevant CAD in patients with intermediate to high pretest likelihood, although an abnormal CT angiography study is a poor predictor of ischemia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To prospectively assess the depiction rate and morphologic features of myocardial bridging (MB) of coronary arteries with 64-section computed tomographic (CT) coronary angiography in comparison to conventional coronary angiography. MATERIALS AND METHODS: Patients were simultaneously enrolled in a prospective study comparing CT and conventional coronary angiography, for which ethics committee approval and informed consent were obtained. One hundred patients (38 women, 62 men; mean age, 63.8 years +/- 11.6 [standard deviation]) underwent 64-section CT and conventional coronary angiography. Fifty additional patients (19 women, 31 men; mean age, 59.2 years +/- 13.2) who underwent CT only were also included. CT images were analyzed for the direct signs length, depth, and degree of systolic compression, while conventional angiograms were analyzed for the indirect signs step down-step up phenomenon, milking effect, and systolic compression of the tunneled segment. Statistical analysis was performed with Pearson correlation analysis, the Wilcoxon two-sample test, and Fisher exact tests. RESULTS: MB was detected with CT in 26 (26%) of 100 patients and with conventional angiography in 12 patients (12%). Mean tunneled segment length and depth at CT (n = 150) were 24.3 mm +/- 10.0 and 2.6 mm +/- 0.8, respectively. Systolic compression in the 12 patients was 31.3% +/- 11.0 at CT and 28.2% +/- 10.5 at conventional angiography (r = 0.72, P < .001). With CT, a significant correlation was not found between systolic compression and length (r = 0.16, P = .25, n = 150) but was found with depth (r = 0.65, P < .01, n = 150) of the tunneled segment. In 14 patients in whom MB was found at CT but not at conventional angiography, length, depth, and systolic compression were significantly lower than in patients in whom both modalities depicted the anomaly (P < .001, P < .01, and P < .001, respectively). CONCLUSION: The depiction rate of MB is greater with 64-section CT coronary angiography than with conventional coronary angiography. The degree of systolic compression of MB significantly correlates with tunneled segment depth but not length.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: This study investigated the role of a negative FAST in the diagnostic and therapeutic algorithm of multiply injured patients with liver or splenic lesions. METHODS: A retrospective analysis of 226 multiply injured patients with liver or splenic lesions treated at Bern University Hospital, Switzerland. RESULTS: FAST failed to detect free fluid or organ lesions in 45 of 226 patients with spleen or liver injuries (sensitivity 80.1%). Overall specificity was 99.5%. The positive and negative predictive values were 99.4% and 83.3%. The overall likelihood ratios for a positive and negative FAST were 160.2 and 0.2. Grade III-V organ lesions were detected more frequently than grade I and II lesions. Without the additional diagnostic accuracy of a CT scan, the mean ISS of the FAST-false-negative patients would be significantly underestimated and 7 previously unsuspected intra-abdominal injuries would have been missed. CONCLUSION: FAST is an expedient tool for the primary assessment of polytraumatized patients to rule out high grade intra-abdominal injuries. However, the low overall diagnostic sensitivity of FAST may lead to underestimated injury patterns and delayed complications may occur. Hence, in hemodynamically stable patients with abdominal trauma, an early CT scan should be considered and one must be aware of the potential shortcomings of a "negative FAST".

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Although urinalysis is simple and inexpensive to perform, the finding of microhaematuria on urinalysis may be unreliable for diagnosing urolithiasis. OBJECTIVE: To evaluate microhaematuria as a diagnostic marker for urolithiasis compared with low-dose unenhanced multidetector computed tomography (MDCT) as the "gold standard". SETTING: A level 1 emergency department in a tertiary referral university teaching hospital. DESIGN: Retrospective analysis. METHODS: A study was undertaken to assess whether the finding of microhaematuria was diagnostic for urolithiasis using a low-dose unenhanced MDCT-based diagnosis as the reference standard by reviewing the records of all patients who presented to the emergency department with colicky flank pain and underwent a CT scan between January 2003 and December 2005. RESULTS: Urolithiasis was present (as defined by low-dose unenhanced MDCT) in 507/638 patients (79%); 341/638 (53%) were true positive for urolithiasis, 76 (12%) were true negative, 55 (9%) were false positive and 166 (26%) were false negative. Microhaematuria as a test for urolithiasis in patients presenting to the emergency department therefore has a sensitivity, specificity, positive predictive value and negative predictive value of 67%, 58%, 86% and 31%, respectively. 58% of the urinalysis results were negative for haematuria in the subset of patients with significant alternative diagnoses. CONCLUSIONS: The sensitivity, specificity and negative predictive value of microhaematuria on urinalysis for urolithiasis using unenhanced MDCT as the reference standard were low. This suggests that, when urolithiasis is clinically suspected, unenhanced MDCT is indicated without urinalysis being a prerequisite.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to validate the accuracy, consistency, and reproducibility/reliability of a new method for correction of pelvic tilt and rotation of radiographic hip parameters for pincer type of femoroacetabular impingement on an anteroposterior pelvic radiograph. Thirty cadaver hips and 100 randomized, blinded AP pelvic radiographs were used for investigation. To detect the software accuracy, the calculated femoral head coverage and classic hip parameters determined with our software were compared to reference measurements based on CT scans or conventional radiographs in a neutral orientation as gold standard. To investigate software consistency, differences among the different parameters for each cadaver pelvis were calculated when reckoned back from a random to the neutral orientation. Intra- and interobserver comparisons were used to analyze the reliability and reproducibility of all parameters. All but two parameters showed a good-to-very good accuracy with the reference measurements. No relevant systematic errors were detected in the Bland-Altman analysis. Software consistency was good-to-very good for all parameters. A good-to-very good reliability and reproducibility was found for a substantial number of the evaluated radiographic acetabular parameters. The software appears to be an accurate, consistent, reliable, and reproducible method for analysis of acetabular pathomorphologies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: In this prospective study we set out to investigate the diagnostic value of [(11)C]choline-PET/CT in patients with suspected lymph node metastases before salvage lymph node dissection. PATIENTS AND METHODS: 15 consecutive patients with rising PSA underwent [(11)C]choline-PET/CT and consecutive open salvage pelvic/retroperitoneal extended lymph node dissection due to uptake of [(11)C]choline in at least 1 lymph node. Mean age was 62.1 (range 53-73). RESULTS: [(11)C]choline-PET/CT results were compared with the histopathology reports and clinical follow-up (mean 13.7 months, range 6-24). Mean time to progression was 23.6 months (range 4-81). [(11)C]choline uptake was observed in nodes along the external and internal and common iliac arteries and in the paraaortic region. A positive histology was reported in 8/15 patients. Only one patient had a PSA nadir of <0.1 ng/ml after salvage surgery. Another patient had stable disease with a PSA of 0.5 ng/ml. Three patients developed bone metastases during follow-up. CONCLUSIONS: This interim analysis indicates that [(11)C]choline-PET/CT may be a useful technique in detection of lymph node metastases when rising PSA occurs after definite prostate cancer therapy. The presented cohort is limited in size, but there is still strong evidence that the patients benefit from [(11)C]choline-PET/CT and consecutive salvage lymph node dissection is rather small.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Nonconvulsive status epilepticus (NCSE) is associated with a mortality rate of up to 18%, therefore requiring prompt diagnosis and treatment. Our aim was to evaluate the diagnostic value of perfusion CT (PCT) in the differential diagnosis of NCSE versus postictal states in patients presenting with persistent altered mental states after a preceding epileptic seizure. We hypothesized that regional cortical hyperperfusion can be measured by PCT in patients with NCSE, whereas it is not present in postictal states. MATERIALS AND METHODS: Nineteen patients with persistent altered mental status after a preceding epileptic seizure underwent PCT and electroencephalography (EEG). Patients were stratified as presenting with NCSE (n = 9) or a postictal state (n = 10) on the basis of clinical history and EEG data. Quantitative and visual analysis of the perfusion maps was performed. RESULTS: Patients during NCSE had significantly increased regional cerebral blood flow (P > .0001), increased regional cerebral blood volume (P > .001), and decreased (P > .001) mean transit time compared with the postictal state. Regional cortical hyperperfusion was depicted in 7/9 of patients with NCSE by ad hoc analysis of parametric perfusion maps during emergency conditions but was not a feature of postictal states. The areas of hyperperfusion were concordant with transient clinical symptoms and EEG topography in all cases. CONCLUSIONS: Visual analysis of perfusion maps detected regional hyperperfusion in NCSE with a sensitivity of 78%. The broad availability and short processing time of PCT in an emergency situation is a benefit compared with EEG. Consequently, the use of PCT in epilepsy may accelerate the diagnosis of NCSE. PCT may qualify as a complementary diagnostic tool to EEG in patients with persistent altered mental state after a preceding seizure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To determine if multi–detector row computed tomography (CT) can replace conventional radiography and be performed alone in severe trauma patients for the depiction of thoracolumbar spine fractures. MATERIALS AND METHODS: One hundred consecutive severe trauma patients who underwent conventional radiography of the thoracolumbar spine as well as thoracoabdominal multi–detector row CT were prospectively identified. Conventional radiographs were reviewed independently by three radiologists and two orthopedic surgeons; CT images were reviewed by three radiologists. Reviewers were blinded both to one another’s reviews and to the results of initial evaluation. Presence, location, and stability of fractures, as well as quality of reviewed images, were assessed. Statistical analysis was performed to determine sensitivity and interobserver agreement for each procedure, with results of clinical and radiologic follow-up as the standard of reference. The time to perform each examination and the radiation dose involved were evaluated. A resource cost analysis was performed. RESULTS: Sixty-seven fractured vertebrae were diagnosed in 26 patients. Twelve patients had unstable spine fractures. Mean sensitivity and interobserver agreement, respectively, for detection of unstable fractures were 97.2% and 0.951 for multi–detector row CT and 33.3% and 0.368 for conventional radiography. The median times to perform a conventional radiographic and a multi–detector row CT examination, respectively, were 33 and 40 minutes. Effective radiation doses at conventional radiography of the spine and thoracoabdominal multi–detector row CT, respectively, were 6.36 mSv and 19.42 mSv. Multi–detector row CT enabled identification of 146 associated traumatic lesions. The costs of conventional radiography and multi–detector row CT, respectively, were $145 and $880 per patient. CONCLUSION: Multi–detector row CT is a better examination for depicting spine fractures than conventional radiography. It can replace conventional radiography and be performed alone in patients who have sustained severe trauma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Quantitative characterisation of carotid atherosclerosis and classification into symptomatic or asymptomatic is crucial in planning optimal treatment of atheromatous plaque. The computer-aided diagnosis (CAD) system described in this paper can analyse ultrasound (US) images of carotid artery and classify them into symptomatic or asymptomatic based on their echogenicity characteristics. The CAD system consists of three modules: a) the feature extraction module, where first-order statistical (FOS) features and Laws' texture energy can be estimated, b) the dimensionality reduction module, where the number of features can be reduced using analysis of variance (ANOVA), and c) the classifier module consisting of a neural network (NN) trained by a novel hybrid method based on genetic algorithms (GAs) along with the back propagation algorithm. The hybrid method is able to select the most robust features, to adjust automatically the NN architecture and to optimise the classification performance. The performance is measured by the accuracy, sensitivity, specificity and the area under the receiver-operating characteristic (ROC) curve. The CAD design and development is based on images from 54 symptomatic and 54 asymptomatic plaques. This study demonstrates the ability of a CAD system based on US image analysis and a hybrid trained NN to identify atheromatous plaques at high risk of stroke.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, a computer-aided diagnostic (CAD) system for the classification of hepatic lesions from computed tomography (CT) images is presented. Regions of interest (ROIs) taken from nonenhanced CT images of normal liver, hepatic cysts, hemangiomas, and hepatocellular carcinomas have been used as input to the system. The proposed system consists of two modules: the feature extraction and the classification modules. The feature extraction module calculates the average gray level and 48 texture characteristics, which are derived from the spatial gray-level co-occurrence matrices, obtained from the ROIs. The classifier module consists of three sequentially placed feed-forward neural networks (NNs). The first NN classifies into normal or pathological liver regions. The pathological liver regions are characterized by the second NN as cyst or "other disease." The third NN classifies "other disease" into hemangioma or hepatocellular carcinoma. Three feature selection techniques have been applied to each individual NN: the sequential forward selection, the sequential floating forward selection, and a genetic algorithm for feature selection. The comparative study of the above dimensionality reduction methods shows that genetic algorithms result in lower dimension feature vectors and improved classification performance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To describe the most reliable insertion angle, corridor length and width to place a ventral transarticular atlantoaxial screw in miniature breed dogs. STUDY DESIGN: Retrospective CT imaging study. SAMPLE POPULATION: Cervical CT scans of toy breed dogs (n = 21). METHODS: Dogs were divided into 2 groups--group 1: no atlantoaxial abnormalities; group 2: atlantoaxial instability. Insertion angle in medial to lateral and ventral to dorsal direction was measured in group 1. Corridor length and width were measured in groups 1 and 2. Corridor width was measured at 3 points of the corridor. Each variable was measured 3 times and the mean used for statistical analysis. RESULTS: Mean +/- SD optimal transarticular atlantoaxial insertion angle was determined to be 40 +/- 1 degrees in medial to lateral direction from the midline and 20 +/- 1 degrees in ventral to dorsal direction from the floor of the neural canal of C2. Mean corridor length was 7 mm (range, 4.5-8.0 mm). Significant correlation was found between corridor length, body weight, and age. Mean bone corridor width ranged from 3 to 5 mm. Statistically significant differences were found between individuals, gender and measured side. CONCLUSIONS: Optimal placement of a transarticular screw for atlantoaxial joint stabilization is very demanding because the screw path corridor is very narrow.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Article preview View full access options BoneKEy Reports | Review Print Email Share/bookmark Finite element analysis for prediction of bone strength Philippe K Zysset, Enrico Dall'Ara, Peter Varga & Dieter H Pahr Affiliations Corresponding author BoneKEy Reports (2013) 2, Article number: 386 (2013) doi:10.1038/bonekey.2013.120 Received 03 January 2013 Accepted 25 June 2013 Published online 07 August 2013 Article tools Citation Reprints Rights & permissions Abstract Abstract• References• Author information Finite element (FE) analysis has been applied for the past 40 years to simulate the mechanical behavior of bone. Although several validation studies have been performed on specific anatomical sites and load cases, this study aims to review the predictability of human bone strength at the three major osteoporotic fracture sites quantified in recently completed in vitro studies at our former institute. Specifically, the performance of FE analysis based on clinical computer tomography (QCT) is compared with the ones of the current densitometric standards, bone mineral content, bone mineral density (BMD) and areal BMD (aBMD). Clinical fractures were produced in monotonic axial compression of the distal radii, vertebral sections and in side loading of the proximal femora. QCT-based FE models of the three bones were developed to simulate as closely as possible the boundary conditions of each experiment. For all sites, the FE methodology exhibited the lowest errors and the highest correlations in predicting the experimental bone strength. Likely due to the improved CT image resolution, the quality of the FE prediction in the peripheral skeleton using high-resolution peripheral CT was superior to that in the axial skeleton with whole-body QCT. Because of its projective and scalar nature, the performance of aBMD in predicting bone strength depended on loading mode and was significantly inferior to FE in axial compression of radial or vertebral sections but not significantly inferior to FE in side loading of the femur. Considering the cumulated evidence from the published validation studies, it is concluded that FE models provide the most reliable surrogates of bone strength at any of the three fracture sites.