298 resultados para esophagus stenosis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atrial fibrillation (AF) is an important risk factor for stroke and is common among elderly patients undergoing transcatheter aortic valve implantation. The aim of this study was to assess the impact of AF on clinical outcomes among patients undergoing transcatheter aortic valve implantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stroke is the most debilitating cardiovascular event. It has a variety of causes that may be present simultaneously. In young or otherwise healthy people, the search for a patent foramen ovale (PFO) has become standard. In stroke of the elderly, atherosclerosis and atrial fibrillation are in the foreground but the PFO should not be ignored. The risk of a PFO-related stroke over time is controversial and so is its prevention by device closure. The association of proximal aortic plaques in arteries subtending the brain and stroke is considered strong, ignoring that it is as putative as that of the PFO. Statins can prevent progression of such plaques. Antiplatelet agents in asymptomatic and surgical endarterectomy in symptomatic patients or highly ulcerated lesions are the treatment of choice. Stenting with protection devices was shown competitive in selected patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the past decades, endoscopic mucosal resection (EMR) has been developed to treat early intramucosal esophageal cancers and dysplastic Barrett's esophagus. The primary drawback of this method is severe postsurgical esophageal stricture formation. The purpose of this preclinical study was to assess strategies for prevention of this major complication by injecting autologous keratinocytes in the EMR mucosal defect in the sheep model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Renovascular hypertension is due to reduced renal parenchymal perfusion. The correct diagnosis can be difficult. It is important to note that the demonstration of renal artery stenosis in a patient with hypertension does not necessarily constitute renovascular hypertension. Often, clinically nonsignificant and asymptomatic renal artery stenosis are found in patients with essential hypertension, or renal failure of other origin. Renovascular disease is a complex disorder with various clinical presentations. In patients with significant renovascular hypertension plasma renin is increased. For this reason the therapy aims to block the renin-angiotensin-aldosterone system. Bilateral renal artery stenosis causes renal sodium retention. In this situation a diuretic drug has to be added to the therapy. Endovascular or surgical therapy has to be considered in patients with flash pulmonary edema or fibromuscular dysplasia. The control of cardiovascular risk factors is important.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the long-term results of double bicanalicular silicone tubes in canalicular (presaccal) stenosis of the nasolacrimal duct system, a retrospective follow-up was performed on patients operated between 1992 and 2002. Forty-five patients were included in the study, 44 of whom had eyes with canalicular stenosis (primary dacryocystorhinostomy), 4 with congenital agenesis of the lacrimal duct system, and 3 cases after primary external dacryocystorhinostomy. Double bicanalicular silicone tubes were inserted, fixed in the vestibulum nasi, and left in place as long-term space holders. Of the 51 endonasal primary dacryocystorhinostomies with canalicular stenosis, 32 (63%) became symptom-free after one procedure. Nineteen (37%) patients had a relapse. Double silicone bicanalicular tube insertion as long-term spacers in canalicular stenoses has a number of advantages, but canalicular stenoses still remain a challenging area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: The goal of this study was to assess the prevalence of left ventricular (LV) hypertrophy in patients with aortic stenosis late (>6 months) after aortic valve replacement and its impact on cardiac-related morbidity and mortality. METHODS AND RESULTS: In a single tertiary centre, echocardiographic data of LV muscle mass were collected. Detailed information of medical history and angiographic data were gathered. Ninety-nine of 213 patients (46%) had LV hypertrophy late (mean 5.8 +/- 5.4 years) after aortic valve replacement. LV hypertrophy was associated with impaired exercise capacity, higher New York Heart Association dyspnoea class, a tendency for more frequent chest pain expressed as higher Canadian Cardiovascular Society class, and more rehospitalizations. 24% of patients with normal LV mass vs. 39% of patients with LV hypertrophy reported cardiac-related morbidity (p = 0.04). In a multivariate logistic regression model, LV hypertrophy was an independent predictor of cardiac-related morbidity (odds ratio 2.31, 95% CI 1.08 to 5.41), after correction for gender, baseline ejection fraction, and coronary artery disease and its risk factors. Thirty seven deaths occurred during a total of 1959 patient years of follow-up (mean follow-up 9.6 years). Age at aortic valve replacement (hazard ratio 1.85, 95% CI 1.39 to 2.47, for every 5 years increase in age), coexisting coronary artery disease at the time of surgery (hazard ratio 3.36, 95% CI 1.31 to 8.62), and smoking (hazard ratio 4.82, 95% CI 1.72 to 13.45) were independent predictors of overall mortality late after surgery, but not LV hypertrophy. CONCLUSIONS: In patients with aortic valve replacement for isolated aortic stenosis, LV hypertrophy late after surgery is associated with increased morbidity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe the case of 77-year-old woman who underwent five coronary angiographies in 9 months due to in-stent re-stenosis of Cypher-Stents, and who finally required coronary artery bypass grafting surgery. Preoperative investigations revealed a significant internal carotid stenosis, which was due to a fractured and embolized Cypher-Stent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND STUDY AIMS: The reference surveillance method in patients with Barrett's esophagus is careful endoscopic observation, with targeted as well as random four-quadrant biopsies. Autofluorescence endoscopy (AFE) may make it easier to locate neoplasia. The aim of this study was to elucidate the diagnostic accuracy of surveillance with AFE-guided plus four-quadrant biopsies in comparison with the conventional approach. PATIENTS AND METHODS: A total of 187 of 200 consecutive Barrett's esophagus patients who were initially enrolled (73 % male, mean age 67 years, mean Barrett's segment length 4.6 cm), who underwent endoscopy for Barrett's esophagus in four study centers, were randomly assigned to undergo either AFE-targeted biopsy followed by four-quadrant biopsies or conventional endoscopic surveillance, also including four-quadrant biopsies (study phase 1). After exclusion of patients with early cancer or high-grade dysplasia, who underwent endoscopic or surgical treatment, as well as those who declined to participate in phase 2 of the study, 130 patients remained. These patients were examined again with the alternative method after a mean of 10 weeks, using the same methods described. The main study parameter was the detection of early cancer/adenocarcinoma or high-grade dysplasia (HGD), comparing both approaches in study phase 1; the secondary study aim in phase 2 was to assess the additional value of the AFE-guided approach after conventional surveillance, and vice versa. Test accuracy measures were derived from study phase 1. RESULTS: In study phase 1, the AFE and conventional approaches yielded adenocarcinoma/HGD rates of 12 % and 5.3 %, respectively, on a per-patient basis. With AFE, four previously unrecognized adenocarcinoma/HGD lesions were identified (4.3 % of the patients); with the conventional approach, one new lesion (1.1 %) was identified. Of the 19 adenocarcinoma/HGD lesions detected during AFE endoscopy in study phase 1, eight were visualized, while 11 were only detected using untargeted four-quadrant biopsies (sensitivity 42 %). Of the 766 biopsies classified at histology as being nonneoplastic, 58 appeared suspicious (specificity 92 %, positive predictive value 12 %, negative predictive value 98.5 %). In study phase 2, AFE detected two further lesions in addition to the initial alternative approach in 3.2 % of cases, in comparison with one lesion with conventional endoscopy (1.7 %). CONCLUSIONS: In this referral Barrett's esophagus population with a higher prevalence of neoplastic lesions, the AFE-guided approach improved the diagnostic yield for neoplasia in comparison with the conventional approach using four-quadrant biopsies. However, AFE alone was not suitable for replacing the standard four-quadrant biopsy protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Multislice computed tomography (MSCT) is a promising noninvasive method of detecting coronary artery disease (CAD). However, most data have been obtained in selected series of patients. The purpose of the present study was to investigate the accuracy of 64-slice MSCT (64 MSCT) in daily practice, without any patient selection. METHODS AND RESULTS: Using 64-slice MSCT coronary angiography (CTA), 69 consecutive patients, 39 (57%) of whom had previously undergone stent implantation, were evaluated. The mean heart rate during scan was 72 beats/min, scan time 13.6 s and the amount of contrast media 72 mL. The mean time span between invasive coronary angiography (ICAG) and CTA was 6 days. Significant stenosis was defined as a diameter reduction of > 50%. Of 966 segments, 884 (92%) were assessable. Compared with ICAG, the sensitivity of CTA to diagnose significant stenosis was 90%, specificity 94%, positive predictive value (PPV) 89% and negative predictive value (NPV) 95%. With regard to 58 stented lesions, the sensitivity, specificity, PPV and NPV were 93%, 96%, 87% and 98%, respectively. On the patient-based analysis, the sensitivity, specificity, PPV and NPV of CTA to detect CAD were 98%, 86%, 98% and 86%, respectively. Eighty-two (8%) segments were not assessable because of irregular rhythm, calcification or tachycardia. CONCLUSION: Sixty-four-MSCT has a high accuracy for the detection of significant CAD in an unselected patient population and therefore can be considered as a valuable noninvasive technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Current concepts of catheter ablation for atrial fibrillation (AF) commonly use three-dimensional (3D) reconstructions of the left atrium (LA) for orientation, catheter navigation, and ablation line placement. OBJECTIVES: The purpose of this study was to compare the 3D electroanatomic reconstruction (Carto) of the LA, pulmonary veins (PVs), and esophagus with the true anatomy displayed on multislice computed tomography (CT). METHODS: In this prospective study, 100 patients undergoing AF catheter ablation underwent contrast-enhanced spiral CT scan with barium swallow and subsequent multiplanar and 3D reconstructions. Using Carto, circumferential plus linear LA lesions were placed. The esophagus was tagged and integrated into the Carto map. RESULTS: Compared with the true anatomy on CT, the electroanatomic reconstruction accurately displayed the true distance between the lower PVs; the distances between left upper PV, left lower PV, right lower PV, and center of the esophagus; the longitudinal diameter of the encircling line around the funnel of the left PVs; and the length of the mitral isthmus line. Only the distances between the upper PVs, the distance between the right upper PV and esophagus, and the diameter of the right encircling line were significantly shorter on the electroanatomic reconstructions. Furthermore, electroanatomic tagging of the esophagus reliably visualized the true anatomic relationship to the LA. On multiple tagging and repeated CT scans, the LA and esophagus showed a stable anatomic relationship, without relevant sideward shifting of the esophagus. CONCLUSION: Electroanatomic reconstruction can display with high accuracy the true 3D anatomy of the LA and PVs in most of the regions of interest for AF catheter ablation. In addition, Carto was able to visualize the true anatomic relationship between the esophagus and LA. Both structures showed a stable anatomic relationship on Carto and CT without relevant sideward shifting of the esophagus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: We sought to determine both the procedural performance and safety of percutaneous implantation of the second (21-French [F])- and third (18-F)-generation CoreValve aortic valve prosthesis (CoreValve Inc., Irvine, California). BACKGROUND: Percutaneous aortic valve replacement represents an emerging alternative therapy for high-risk and inoperable patients with severe symptomatic aortic valve stenosis. METHODS: Patients with: 1) symptomatic, severe aortic valve stenosis (area <1 cm2); 2) age > or =80 years with a logistic EuroSCORE > or =20% (21-F group) or age > or =75 years with a logistic EuroSCORE > or =15% (18-F group); or 3) age > or =65 years plus additional prespecified risk factors were included. Introduction of the 18-F device enabled the transition from a multidisciplinary approach involving general anesthesia, surgical cut-down, and cardiopulmonary bypass to a truly percutaneous approach under local anesthesia without hemodynamic support. RESULTS: A total of 86 patients (21-F, n = 50; 18-F, n = 36) with a mean valve area of 0.66 +/- 0.19 cm2 (21-F) and 0.54 +/- 0.15 cm2 (18-F), a mean age of 81.3 +/- 5.2 years (21-F) and 83.4 +/- 6.7 years (18-F), and a mean logistic EuroSCORE of 23.4 +/- 13.5% (21-F) and 19.1 +/- 11.1% (18-F) were recruited. Acute device success was 88%. Successful device implantation resulted in a marked reduction of aortic transvalvular gradients (mean pre 43.7 mm Hg vs. post 9.0 mm Hg, p < 0.001) with aortic regurgitation grade remaining unchanged. Acute procedural success rate was 74% (21-F: 78%; 18-F: 69%). Procedural mortality was 6%. Overall 30-day mortality rate was 12%; the combined rate of death, stroke, and myocardial infarction was 22%. CONCLUSIONS: Treatment of severe aortic valve stenosis in high-risk patients with percutaneous implantation of the CoreValve prosthesis is feasible and associated with a lower mortality rate than predicted by risk algorithms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This study was designed to compare the long-term clinical outcome of coronary artery bypass grafting (CABG) with intracoronary stenting of patients with isolated proximal left anterior descending coronary artery. BACKGROUND: Although numerous trials have compared coronary angioplasty with bypass surgery, none assessed the clinical evaluation in the long term. METHODS: We evaluated the 10-year clinical outcome in the SIMA (Stent versus Internal Mammary Artery grafting) trial. Patients were randomly assigned to stent implantation versus CABG. RESULTS: Of 123 randomized patients, 59 underwent CABG and 62 received a stent (2 patients were excluded). Follow-up after 10 years was obtained for 98% of the randomized patients. Twenty-six patients (42%) in the percutaneous coronary intervention group and 10 patients (17%) in the CABG group reached an end point (p < 0.001). This difference was due to a higher need for additional revascularization. The incidences of death and myocardial infarction were identical at 10%. Progression of the disease requiring additional revascularization was rare (5%) and was similar for the 2 groups. Stent thrombosis occurred in 2 patients (3%). Angina functional class showed no significant differences between the 2 groups. CONCLUSIONS: Both stent implantation and CABG are safe and highly effective in relieving symptoms in patients with isolated, proximal left anterior descending coronary artery stenosis. Stenting with bare-metal stents is associated with a higher need for repeat interventions. The long-term prognosis for these patients is excellent with either mode of revascularization.