39 resultados para elbow radiography
Resumo:
OBJECTIVE The purpose of this study was to investigate the feasibility of microdose CT using a comparable dose as for conventional chest radiographs in two planes including dual-energy subtraction for lung nodule assessment. MATERIALS AND METHODS We investigated 65 chest phantoms with 141 lung nodules, using an anthropomorphic chest phantom with artificial lung nodules. Microdose CT parameters were 80 kV and 6 mAs, with pitch of 2.2. Iterative reconstruction algorithms and an integrated circuit detector system (Stellar, Siemens Healthcare) were applied for maximum dose reduction. Maximum intensity projections (MIPs) were reconstructed. Chest radiographs were acquired in two projections with bone suppression. Four blinded radiologists interpreted the images in random order. RESULTS A soft-tissue CT kernel (I30f) delivered better sensitivities in a pilot study than a hard kernel (I70f), with respective mean (SD) sensitivities of 91.1% ± 2.2% versus 85.6% ± 5.6% (p = 0.041). Nodule size was measured accurately for all kernels. Mean clustered nodule sensitivity with chest radiography was 45.7% ± 8.1% (with bone suppression, 46.1% ± 8%; p = 0.94); for microdose CT, nodule sensitivity was 83.6% ± 9% without MIP (with additional MIP, 92.5% ± 6%; p < 10(-3)). Individual sensitivities of microdose CT for readers 1, 2, 3, and 4 were 84.3%, 90.7%, 68.6%, and 45.0%, respectively. Sensitivities with chest radiography for readers 1, 2, 3, and 4 were 42.9%, 58.6%, 36.4%, and 90.7%, respectively. In the per-phantom analysis, respective sensitivities of microdose CT versus chest radiography were 96.2% and 75% (p < 10(-6)). The effective dose for chest radiography including dual-energy subtraction was 0.242 mSv; for microdose CT, the applied dose was 0.1323 mSv. CONCLUSION Microdose CT is better than the combination of chest radiography and dual-energy subtraction for the detection of solid nodules between 5 and 12 mm at a lower dose level of 0.13 mSv. Soft-tissue kernels allow better sensitivities. These preliminary results indicate that microdose CT has the potential to replace conventional chest radiography for lung nodule detection.
Resumo:
In many designs for radioactive waste repositories, cement and clay will come into direct contact. The geochemical contrast between cement and clay will lead to mass fluxes across the interface, which consequently results in alteration of structural and transport properties of both materials that may affect the performance of the multi-barrier system. We present an experimental approach to study cement-clay interactions with a cell to accommodate small samples of cement and clay. The cell design allows both in situ measurement of water content across the sample using neutron radiography and measurement of transport parameters using through-diffusion tracer experiments. The aim of the high- resolution neutron radiography experiments was to monitor changes in water content (porosity) and their spatial extent. Neutron radiographs of several evolving cement-clay interfaces delivered quantitative data which allow resolving local water contents within the sample domain. In the present work we explored the uncertainties of the derived water contents with regard to various input parameters and with regard to the applied image correction procedures. Temporal variation of measurement conditions created absolute uncertainty of the water content in the order of ±0.1 (m3/m3), which could not be fully accounted for by correction procedures. Smaller relative changes in water content between two images can be derived by specific calibrations to two sample regions with different, invariant water contents.
Resumo:
BACKGROUND Ulnar nerve decompression at the elbow traditionally requires regional or general anesthesia. We wished to assess the feasibility of performing ulnar nerve decompression and transposition at the elbow under local anesthesia. METHODS We examined retrospectively the charts of 50 consecutive patients having undergone ulnar nerve entrapment surgery either under general or local anesthesia. Patients were asked to estimate pain on postoperative days 1 and 7 and satisfaction was assessed at 1 year. RESULTS On day 1, pain was comparable among all groups. On day 7, pain scores were twice as high when transposition was performed under general anesthesia when compared with local anesthesia. Patient satisfaction was slightly increased in the local anesthesia group. These patients were significantly more willing to repeat the surgery. CONCLUSION Ulnar nerve decompression and transposition at the elbow can be performed under local anesthesia without added morbidity when compared with general anesthesia.
Resumo:
BACKGROUND AND OBJECTIVES Despite the recommendations of national and international societies for the treatment of patients with acute neck and back pain, still too many radiologic examinations were performed. The purpose of this study was to analyze and optimize diagnostics and treatment of patients with acute back pain. METHODS The medical records of 484 patients presented to the emergency clinic with acute neck or back pain were analyzed for clinical history, physical examination, radiographic findings and therapy. RESULTS Radiographs of the lumbar, cervical, or thoracic spine were performed in 338 cases (70%). Radiographs were normal in 142 patients (42%) and degenerative changes were identified in 123 patients (36%). Only 2 patients (0.4%) had radiographic findings that had direct therapeutic relevance: 1 patient with metastatic disease and 1 patient with posttraumatic C1-C2 instability. For most patients without sensorimotor deficits and absent specific indications for radiography (“red flags”), therapy was not affected by the results of radiography. CONCLUSIONS Plain radiography of the spine was unnecessary in most patients initially evaluated with non-specific acute back pain and does not improve the clinical outcome. The implementation of national and international guidelines is a slow process, but helps to reduce costs and to protect patients from unnecessary ionizing radiation exposure.
Resumo:
OBJECTIVE To compare the accuracy of radiography and computed tomography (CT) in predicting implant position in relation to the vertebral canal in the cervical and thoracolumbar vertebral column. STUDY DESIGN In vitro imaging and anatomic study. ANIMALS Medium-sized canine cadaver vertebral columns (n=12). METHODS Steinmann pins were inserted into cervical and thoracolumbar vertebrae based on established landmarks but without predetermination of vertebral canal violation. Radiographs and CT images were obtained and evaluated by 6 individuals. A random subset of pins was evaluated for ability to distinguish left from right pins on radiographs. The ability to correctly identify vertebral canal penetration for all pins was assessed both on radiographs and CT. Spines were then anatomically prepared and visual examination of pin penetration into the canal served as the gold standard. RESULTS Left/right accuracy was 93.1%. Overall sensitivity of radiographs and CT to detect vertebral canal penetration by an implant were significantly different and estimated as 50.7% and 93.4%, respectively (P<.0001). Sensitivity was significantly higher for complete versus partial penetration and for radiologists compared with nonradiologists for both imaging modalities. Overall specificity of radiographs and CT to detect vertebral canal penetration was 82.9% and 86.4%, respectively (P=.049). CONCLUSIONS CT was superior to radiographic assessment and is the recommended imaging modality to assess penetration into the vertebral canal. CLINICAL RELEVANCE CT is significantly more accurate in identifying vertebral canal violation by Steinmann pins and should be performed postoperatively to assess implant position.