147 resultados para corrective orthodontics


Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this article was to assess the effect of wire adaptation on the lingual surfaces of mandibular anterior teeth with 3 types of lingual retainers on the development of vertical and labiolingual forces.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to assess the changes in inclination of the maxillary second (M2) and third (M3) molars after orthodontic treatment of Class II Division 1 malocclusion with extraction of maxillary first molars.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Three-dimensional (3D) models of teeth and soft and hard tissues are tessellated surfaces used for diagnosis, treatment planning, appliance fabrication, outcome evaluation, and research. In scientific publications or communications with colleagues, these 3D data are often reduced to 2-dimensional pictures or need special software for visualization. The portable document format (PDF) offers a simple way to interactively display 3D surface data without additional software other than a recent version of Adobe Reader (Adobe, San Jose, Calif). The purposes of this article were to give an example of how 3D data and their analyses can be interactively displayed in 3 dimensions in electronic publications, and to show how they can be exported from any software for diagnostic reports and communications among colleagues.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The flexible spiral wire (FSW) canine-to-canine lingual retainer bonded to all 6 anterior teeth is a frequently used type of mandibular fixed retainer. This study aimed to assess the long-term effectiveness of FSW canine-to-canine lingual retainers in maintaining the alignment of the mandibular anterior teeth after orthodontic treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate maxillary dental arch dimensions in pre-school children with a complete unilateral cleft lip and palate (CUCLP) after early alveolar bone grafting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Our aim was to quantitatively determine the bisphenol-A (BPA) released from a light-cured orthodontic adhesive used to bond lingual fixed retainers.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aortic stenosis has become the most frequent type of valvular heart disease in Europe and North America and presents in the large majority of patients as calcified aortic stenosis in adults of advanced age. Surgical aortic valve replacement has been recognized to be the definitive therapy which improves considerably survival for severe aortic stenosis since more than 40 years. In the most recent period, operative mortality of isolated aortic valve replacement for aortic stenosis varies between 1–3% in low-risk patients younger than 70 years and between 4 and 8% in selected older adults. Long-term survival following aortic valve replacement is close to that observed in a control population of similar age. Numerous observational studies have consistently demonstrated that corrective surgery in symptomatic patients is invariably followed by a subjective improvement in quality of life and a substantial increase in survival rates. More recently, transcatheter aortic valve implantation (TAVI) has been demonstrated to be feasible in patients with high surgical risk using either a retrograde transfemoral or transsubclavian approach or an antegrade, transapical access. Reported 30-day mortality ranges between 5 and 15%) and is acceptable when compared to the risk predicted by the logistic EuroSCORE (varying between 20 and 35%) and the STS Score, although the EuroScore has been shown to markedly overestimate the effective operative risk. One major concern remains the high rate of paravalvular regurgitation which is observed in up to 85% of the patients and which requires further follow-up and critical evaluation. In addition, long-term durability of these valves with a focus on the effects of crimping remains to be addressed, although 3-5 year results are promising. Sutureless biological valves were designed to simplify and significantly accelerate the surgical replacement of a diseased valve and allow complete excision of the calcified native valve. Until now, there are 3 different sutureless prostheses that have been approved. The 3f Enable valve from ATS-Medtronic received CE market approval in 2010, the Perceval S from Sorin during Q1 of 2011 and the intuity sutureless prosthesis from Edwards in 2012. All these devices aim to facilitate valve surgery and therefore have the potential to decrease the invasivness and to shorten the conventional procedure without compromise in term of excision of the diseased valve. This review summarizes the history and the current knowledge of sutureless valve technology.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the enamel loss and composite remnants after debonding and clean-up. The tested null hypothesis is that there are no differences between different polishing systems regarding removing composite remnants without damaging the tooth surface. Brackets were bonded to 75 extracted human molars and removed after a storage period of 100 hours. The adhesive remnant index (ARI) was evaluated. The clean-up was carried out with five different procedures: 1. carbide bur; 2. carbide bur and Brownie and Greenie silicone polishers; 3. carbide bur and Astropol polishers; 4. carbide bur and Renew polishers; and 5. carbide bur, Brownie, Greenie and PoGo polishers. Silicone impressions were made at baseline (T0) and after debonding (T1) and polishing (T2) to produce plaster replicas. The replicas were analysed with a three-dimensional laser scanner and measured with analytical software. Statistical analysis was performed with the Kruskal-Wallis test and pairwise Wilcoxon tests with Bonferroni-Holm adjustment (α = 0.05). Enamel breakouts after debonding were detectable in 27 per cent of all cases, with a mean volume loss of 0.02 mm(3) (±0.03 mm(3)) and depth of 44.9 μm (±48.3 μm). The overall ARI scores was 3 with a few scores of 1 and 2. The composite remnants after debonding had a mean volume of 2.48 mm(3) (±0.92 mm(3)). Mean volume loss due to polishing was 0.05 mm(3) (±0.26 mm(3)) and the composite remnants had a mean volume of 0.22 mm(3) (±0.32 mm(3)). There were no statistically significant differences in volumetric changes after polishing (P = 0.054) between the different clean-up methods. However, sufficient clean-up without enamel loss was difficult to achieve.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bonding a flexible spiral wire retainer to the lingual surfaces of all 6 anterior mandibular teeth is a commonly used type of retention. Complications are rare but can be serious enough to produce biologic damage. This article presents a serious complication of a lingual flexible spiral wire retainer. Four years after the orthodontic treatment, a 20-year-old man sought treatment for a broken flexible spiral wire retainer. The clinical examination showed about 35° of buccal root torque of that tooth. A cone-beam computed tomography image showed that the root and the apex of the tooth were almost completely out of the bone on its buccal side. Surprisingly, the tooth's vitality was preserved. The tooth was moved back, nearly to its original position; clinically, only a gingival recession remained. Orthodontists and dentists should be aware of possible complications of bonded retainers. Patients should be clearly informed how to detect problems at an early stage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate dental arch relationship in preschoolers with unilateral cleft lip and palate after early alveolar bone grafting (ABG).

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Optimal reporting of randomized trials and abstracts enhances transparency and facilitates assessment and identification of trials. The purpose of this study was to investigate the quality of reporting of abstracts of randomized controlled trials published in orthodontic journals.