122 resultados para biomechanics


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The interest in automatic volume meshing for finite element analysis (FEA) has grown more since the appearance of microfocus CT (μCT), due to its high resolution, which allows for the assessment of mechanical behaviour at a high precision. Nevertheless, the basic meshing approach of generating one hexahedron per voxel produces jagged edges. To prevent this effect, smoothing algorithms have been introduced to enhance the topology of the mesh. However, whether smoothing also improves the accuracy of voxel-based meshes in clinical applications is still under question. There is a trade-off between smoothing and quality of elements in the mesh. Distorted elements may be produced by excessive smoothing and reduce accuracy of the mesh. In the present work, influence of smoothing on the accuracy of voxel-based meshes in micro-FE was assessed. An accurate 3D model of a trabecular structure with known apparent mechanical properties was used as a reference model. Virtual CT scans of this reference model (with resolutions of 16, 32 and 64 μm) were then created and used to build voxel-based meshes of the microarchitecture. Effects of smoothing on the apparent mechanical properties of the voxel-based meshes as compared to the reference model were evaluated. Apparent Young’s moduli of the smooth voxel-based mesh were significantly closer to those of the reference model for the 16 and 32 μm resolutions. Improvements were not significant for the 64 μm, due to loss of trabecular connectivity in the model. This study shows that smoothing offers a real benefit to voxel-based meshes used in micro-FE. It might also broaden voxel-based meshing to other biomechanical domains where it was not used previously due to lack of accuracy. As an example, this work will be used in the framework of the European project ContraCancrum, which aims at providing a patient-specific simulation of tumour development in brain and lungs for oncologists. For this type of clinical application, such a fast, automatic, and accurate generation of the mesh is of great benefit.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to search the orthodontic literature and determine the frequency of reporting of confidence intervals (CIs) in orthodontic journals with an impact factor. The six latest issues of the American Journal of Orthodontics and Dentofacial Orthopedics, the European Journal of Orthodontics, and the Angle Orthodontist were hand searched and the reporting of CIs, P values, and implementation of univariate or multivariate statistical analyses were recorded. Additionally, studies were classified according to the type/design as cross-sectional, case-control, cohort, and clinical trials, and according to the subject of the study as growth/genetics, behaviour/psychology, diagnosis/treatment, and biomaterials/biomechanics. The data were analyzed using descriptive statistics followed by univariate examination of statistical associations, logistic regression, and multivariate modelling. CI reporting was very limited and was recorded in only 6 per cent of the included published studies. CI reporting was independent of journal, study area, and design. Studies that used multivariate statistical analyses had a higher probability of reporting CIs compared with those using univariate statistical analyses. Misunderstanding of the use of P values and CIs may have important implications in implementation of research findings in clinical practice.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sinotubular junction dilation is one of the most frequent pathologies associated with aortic root incompetence. Hence, we create a finite element model considering the whole root geometry; then, starting from healthy valve models and referring to measures of pathological valves reported in the literature, we reproduce the pathology of the aortic root by imposing appropriate boundary conditions. After evaluating the virtual pathological process, we are able to correlate dimensions of non-functional valves with dimensions of competent valves. Such a relation could be helpful in recreating a competent aortic root and, in particular, it could provide useful information in advance in aortic valve sparing surgery.