115 resultados para acoustic tracking


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Daily use of conventional electronic portal imaging devices (EPID) for organ tracking is limited due to the relatively high dose required for high quality image acquisition. We studied the use of a novel dose saving acquisition mode (RadMode) allowing to take images with one monitor unit per image in prostate cancer patients undergoing intensity-modulated radiotherapy (IMRT) and tracking of implanted fiducial gold markers. PATIENTS AND METHODS: Twenty five patients underwent implantation of three fiducial gold markers prior to the planning CT. Before each treatment of a course of 37 fractions, orthogonal localization images from the antero-posterior and from the lateral direction were acquired. Portal images of both the setup procedure and the five IMRT treatment beams were analyzed. RESULTS: On average, four localization images were needed for a correct patient setup, resulting in four monitor units extra dose per fraction. The mean extra dose delivered to the patient was thereby increased by 1.2%. The procedure was precise enough to reduce the mean displacements prior to treatment to < o =0.3 mm. CONCLUSIONS: The use of a new dose saving acquisition mode enables to perform daily EPID-based prostate tracking with a cumulative extra dose of below 1 Gy. This concept is efficiently used in IMRT-treated patients, where separation of setup beams from treatment beams is mandatory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An Internet survey demonstrated the existence of problems related to intraoperative tracking camera set-up and alignment. It is hypothesized that these problems are a result of the limited field of view of today's optoelectronic camera systems, which is usually insufficiently large to keep the entire site of surgical action in view during an intervention. A method is proposed to augment a camera's field of view by actively controlling camera orientation, enabling it to track instruments as they are used intraoperatively. In an experimental study, an increase of almost 300% was found in the effective volume in which instruments could be tracked.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Situationally adaptive behavior relies on the identification of relevant target stimuli, the evaluation of these with respect to the current context and the selection of an appropriate action. We used functional magnetic resonance imaging (fMRI) to disentangle the neural networks underlying these processes within a single task. Our results show that activation of mid-ventrolateral prefrontal cortex (PFC) reflects the perceived presence of a target stimulus regardless of context, whereas context-appropriate evaluation is subserved by mid-dorsolateral PFC. Enhancing demands on response selection by means of response conflict activated a network of regions, all of which are directly connected to motor areas. On the midline, rostral anterior paracingulate cortex was found to link target detection and response selection by monitoring for the presence of behaviorally significant conditions. In summary, we provide new evidence for process-specific functional dissociations in the frontal lobes. In target-centered processing, target detection in the VLPFC is separable from contextual evaluation in the DLPFC. Response-centered processing in motor-associated regions occurs partly in parallel to these processes, which may enhance behavioral efficiency, but it may also lead to reaction time increases when an irrelevant response tendency is elicited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To demonstrate the safety and feasibility of a new concept for CTO recanalization using a controlled antegrade and retrograde subintimal tracking technique (CART technique). BACKGROUND: A successful percutaneous recanalization of chronic coronary occlusions results in improved survival, as well as enhanced left ventricular function, reduction in angina, and improved exercise tolerance. However, successful recanalization of CTOs is still not optimal, and needs further improvements. METHODS: Ten patients with a CTO underwent the CART procedure. This technique combines the simultaneous use of the antegrade and retrograde approaches. A subintimal dissection is created antegradely and retrogradely, which allows the operator to limit the extension of the subintimal dissection in the CTO portion. A retrograde approach means that the occlusion site is approached in a retrograde fashion through the best collateral channel from any other patent coronary artery. RESULTS: The occlusion site was located in the RCA in 9 patients, and in the LAD in 1 patient. CTO duration varied from 7 to 84 months. Vessel recanalization was achieved in all patients. In all cases, the subintimal dissection was limited to the CTO region. No complications occurred in the collateral channel used for the retrograde approach. There were no in-hospital major adverse cardiac events. CONCLUSIONS: The CART technique is feasible, safe, and has a high success rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alveolar echinococcosis (AE)--caused by the cestode Echinococcus multilocularis--is a severe zoonotic disease found in temperate and arctic regions of the northern hemisphere. Even though the transmission patterns observed in different geographical areas are heterogeneous, the nuclear and mitochondrial targets usually used for the genotyping of E. multilocularis have shown only a marked genetic homogeneity in this species. We used microsatellite sequences, because of their high typing resolution, to explore the genetic diversity of E. multilocularis. Four microsatellite targets (EmsJ, EmsK, and EmsB, which were designed in our laboratory, and NAK1, selected from the literature) were tested on a panel of 76 E. multilocularis samples (larval and adult stages) obtained from Alaska, Canada, Europe, and Asia. Genetic diversity for each target was assessed by size polymorphism analysis. With the EmsJ and EmsK targets, two alleles were found for each locus, yielding two and three genotypes, respectively, discriminating European isolates from the other groups. With NAK1, five alleles were found, yielding seven genotypes, including those specific to Tibetan and Alaskan isolates. The EmsB target, a tandem repeated multilocus microsatellite, found 17 alleles showing a complex pattern. Hierarchical clustering analyses were performed with the EmsB findings, and 29 genotypes were identified. Due to its higher genetic polymorphism, EmsB exhibited a higher discriminatory power than the other targets. The complex EmsB pattern was able to discriminate isolates on a regional and sectoral level, while avoiding overdistinction. EmsB will be used to assess the putative emergence of E. multilocularis in Europe.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new implantable hearing system, the direct acoustic cochlear stimulator (DACS) is presented. This system is based on the principle of a power-driven stapes prosthesis and intended for the treatment of severe mixed hearing loss due to advanced otosclerosis. It consists of an implantable electromagnetic transducer, which transfers acoustic energy directly to the inner ear, and an audio processor worn externally behind the implanted ear. The device is implanted using a specially developed retromeatal microsurgical approach. After removal of the stapes, a conventional stapes prosthesis is attached to the transducer and placed in the oval window to allow direct acoustical coupling to the perilymph of the inner ear. In order to restore the natural sound transmission of the ossicular chain, a second stapes prosthesis is placed in parallel to the first one into the oval window and attached to the patient's own incus, as in a conventional stapedectomy. Four patients were implanted with an investigational DACS device. The hearing threshold of the implanted ears before implantation ranged from 78 to 101 dB (air conduction, pure tone average, 0.5-4 kHz) with air-bone gaps of 33-44 dB in the same frequency range. Postoperatively, substantial improvements in sound field thresholds, speech intelligibility as well as in the subjective assessment of everyday situations were found in all patients. Two years after the implantations, monosyllabic word recognition scores in quiet at 75 dB improved by 45-100 percent points when using the DACS. Furthermore, hearing thresholds were already improved by the second stapes prosthesis alone by 14-28 dB (pure tone average 0.5-4 kHz, DACS switched off). No device-related serious medical complications occurred and all patients have continued to use their device on a daily basis for over 2 years. Copyright (c) 2008 S. Karger AG, Basel.