110 resultados para Verification Bias


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We previously reported that nuclear grade assignment of prostate carcinomas is subject to a cognitive bias induced by the tumor architecture. Here, we asked whether this bias is mediated by the non-conscious selection of nuclei that "match the expectation" induced by the inadvertent glance at the tumor architecture. 20 pathologists were asked to grade nuclei in high power fields of 20 prostate carcinomas displayed on a computer screen. Unknown to the pathologists, each carcinoma was shown twice, once before a background of a low grade, tubule-rich carcinoma and once before the background of a high grade, solid carcinoma. Eye tracking allowed to identify which nuclei the pathologists fixated during the 8 second projection period. For all 20 pathologists, nuclear grade assignment was significantly biased by tumor architecture. Pathologists tended to fixate on bigger, darker, and more irregular nuclei when those were projected before kigh grade, solid carcinomas than before low grade, tubule-rich carcinomas (and vice versa). However, the morphometric differences of the selected nuclei accounted for only 11% of the architecture-induced bias, suggesting that it can only to a small part be explained by the unconscious fixation on nuclei that "match the expectation". In conclusion, selection of « matching nuclei » represents an unconscious effort to vindicate the gravitation of nuclear grades towards the tumor architecture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: In the Swiss version of the Freiburg speech intelligibility test five test words from the original German recording which are rarely used in Switzerland have been exchanged. Furthermore, differences in the transfer functions between headphone and loudspeaker presentation are not taken into account during calibration. New settings for the levels of the individual test words in the recommended recording and small changes in calibration procedures led us to make a verification of the currently used normative values.PATIENTS AND METHODS: Speech intelligibility was measured in 20 subjects with normal hearing using monosyllabic words and numbers via headphones and loudspeakers.RESULTS: On average, 50% speech intelligibility was reached at levels which were 7.5 dB lower under free-field conditions than for headphone presentation. The average difference between numbers and monosyllabic words was found to be 9.6 dB, which is considerably lower than the 14 dB of the current normative curves.CONCLUSIONS: There is a good agreement between our measurements and the normative values for tests using monosyllabic words and headphones, but not for numbers or free-field measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Long-term follow up of patients with total hip arthroplasty (THA) revealed a marked deterioration of walking capacities in Charnley class B after postoperative year 4. We hypothesized that a specific group of patients, namely those with unilateral hip arthroplasty and an untreated but affected contralateral hip was responsible for this observation. Therefore, we conducted a study taking into consideration the two subclasses that make up Charnley class B: patients with unilateral THA and contralateral hip disease and patients with bilateral THA. A sample of 15,160 patients with 35,773 follow ups that were prospectively collected over 10 years was evaluated. The sample was categorized into four classes according to a new modified Charnley classification. Annual analyses of the proportion of patients with ambulation longer than 60 min were conducted. The traditionally labeled Charnley class B consists of two very different patient groups with respect to their walking capacities. Those with unilateral THA and contralateral hip disease have underaverage walking capacities and a deterioration of ambulation beginning 3 to 4 years after surgery. Those with bilateral THA have stable overaverage walking capacities similar to Charnley class A. An extension of the traditional Charnley classification is proposed, taking into account the two different patient groups in Charnley class B. The new fourth Charnley class consists of patients with bilateral THA and was labeled BB in order to express the presence of two artificial hip joints and to preserve the traditional classification A through C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Many studies showing effects of traffic-related air pollution on health rely on self-reported exposure, which may be inaccurate. We estimated the association between self-reported exposure to road traffic and respiratory symptoms in preschool children, and investigated whether the effect could have been caused by reporting bias. METHODS: In a random sample of 8700 preschool children in Leicestershire, UK, exposure to road traffic and respiratory symptoms were assessed by a postal questionnaire (response rate 80%). The association between traffic exposure and respiratory outcomes was assessed using unconditional logistic regression and conditional regression models (matching by postcode). RESULTS: Prevalence odds ratios (95% confidence intervals) for self-reported road traffic exposure, comparing the categories 'moderate' and 'dense', respectively, with 'little or no' were for current wheezing: 1.26 (1.13-1.42) and 1.30 (1.09-1.55); chronic rhinitis: 1.18 (1.05-1.31) and 1.31 (1.11-1.56); night cough: 1.17 (1.04-1.32) and 1.36 (1.14-1.62); and bronchodilator use: 1.20 (1.04-1.38) and 1.18 (0.95-1.46). Matched analysis only comparing symptomatic and asymptomatic children living at the same postcode (thus exposed to similar road traffic) showed similar ORs, suggesting that parents of children with respiratory symptoms reported more road traffic than parents of asymptomatic children. CONCLUSIONS: Our study suggests that reporting bias could explain some or even all the association between reported exposure to road traffic and disease. Over-reporting of exposure by only 10% of parents of symptomatic children would be sufficient to produce the effect sizes shown in this study. Future research should be based only on objective measurements of traffic exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Short-acting agents for neuromuscular block (NMB) require frequent dosing adjustments for individual patient's needs. In this study, we verified a new closed-loop controller for mivacurium dosing in clinical trials. METHODS: Fifteen patients were studied. T1% measured with electromyography was used as input signal for the model-based controller. After induction of propofol/opiate anaesthesia, stabilization of baseline electromyography signal was awaited and a bolus of 0.3 mg kg-1 mivacurium was then administered to facilitate endotracheal intubation. Closed-loop infusion was started thereafter, targeting a neuromuscular block of 90%. Setpoint deviation, the number of manual interventions and surgeon's complaints were recorded. Drug use and its variability between and within patients were evaluated. RESULTS: Median time of closed-loop control for the 11 patients included in the data processing was 135 [89-336] min (median [range]). Four patients had to be excluded because of sensor problems. Mean absolute deviation from setpoint was 1.8 +/- 0.9 T1%. Neither manual interventions nor complaints from the surgeons were recorded. Mean necessary mivacurium infusion rate was 7.0 +/- 2.2 microg kg-1 min-1. Intrapatient variability of mean infusion rates over 30-min interval showed high differences up to a factor of 1.8 between highest and lowest requirement in the same patient. CONCLUSIONS: Neuromuscular block can precisely be controlled with mivacurium using our model-based controller. The amount of mivacurium needed to maintain T1% at defined constant levels differed largely between and within patients. Closed-loop control seems therefore advantageous to automatically maintain neuromuscular block at constant levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cardinal feature of spatial neglect is severely impaired exploration of the contralesional space, a failure resulting in unawareness of many contralesional stimuli. This deficit is exacerbated by a reflexive attentional bias toward ipsilesional items. Here we show that, in addition to these spatially lateralized failures, neglect patients also exhibit a severe bias favouring stimuli presented at fixation. We tested neglect patients and matched healthy and right-hemisphere damaged patients without neglect in a task requiring saccade execution to targets in the left or right hemifield. Targets were presented alone or simultaneously with a distracter that appeared in the same hemifield, in the opposite hemifield, or at fixation. We found two fundamental biases in saccade initiation of neglect patients: irrelevant distracters presented in the preserved hemifield tended to capture gaze reflexively, resulting in a large number of saccades erroneously directed toward the distracter. Additionally, distracters presented at fixation severely disrupted saccade initiation irrespective of saccade direction, leading to disproportionately increased latencies of left and right saccades. This latency increase was specific to oculomotor responses of neglect patients and was not observed when a manual response was required. These results show that, in addition to their failure to inhibit reflexive glances toward ipsilesional items neglect patients exhibit a strong oculomotor bias favouring fixated stimuli. We conclude that impaired initiation of saccades in any direction contributes to the deficits of spatial exploration that characterize spatial neglect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The verification possibilities of dynamically collimated treatment beams with a scanning liquid ionization chamber electronic portal image device (SLIC-EPID) are investigated. The ion concentration in the liquid of a SLIC-EPID and therefore the read-out signal is determined by two parameters of a differential equation describing the creation and recombination of the ions. Due to the form of this equation, the portal image detector describes a nonlinear dynamic system with memory. In this work, the parameters of the differential equation were experimentally determined for the particular chamber in use and for an incident open 6 MV photon beam. The mathematical description of the ion concentration was then used to predict portal images of intensity-modulated photon beams produced by a dynamic delivery technique, the sliding window approach. Due to the nature of the differential equation, a mathematical condition for 'reliable leaf motion verification' in the sliding window technique can be formulated. It is shown that the time constants for both formation and decay of the equilibrium concentration in the chamber is in the order of seconds. In order to guarantee reliable leaf motion verification, these time constants impose a constraint on the rapidity of the image-read out for a given maximum leaf speed. For a leaf speed of 2 cm s(-1), a minimum image acquisition frequency of about 2 Hz is required. Current SLIC-EPID systems are usually too slow since they need about a second to acquire a portal image. However, if the condition is fulfilled, the memory property of the system can be used to reconstruct the leaf motion. It is shown that a simple edge detecting algorithm can be employed to determine the leaf positions. The method is also very robust against image noise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensure that the planned dosimetric coverage of the tumor volume is actually realized in the patient. Since the direction of setup fields often deviates from the direction of the treatment beams, extra dose is delivered to the patient during the acquisition of these portal images which may reach clinical relevance. The aim of this work was to develop a new acquisition mode for the PortalVision aS500 electronic portal imaging device from Varian Medical Systems that allows one to take portal images with reduced dose while keeping good image quality. The new acquisition mode, called RadMode, selectively enables and disables beam pulses during image acquisition allowing one to stop wasting valuable dose during the initial acquisition of "reset frames." Images of excellent quality can be taken with 1 MU only. This low dose per image facilitates daily setup verification with considerably reduced extra dose.