51 resultados para Technical Diagnostics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two years ago, CE certified interferon-gamma release assays (IGRA) were launched on the German market (QuantiFERON-TB Gold In-Tube and T-SPOT-TB). Since this time, a multitude of studies have analysed these assays. Guidelines have been elaborated by national expert committees of England, the USA and Switzerland. However, standards of tuberculosis diagnostics and management may vary from country to country. This statement provides practice relevant recommendations for indications, pre-analytics and the interpretation of IGRA test results under different clinical conditions. The IGRA are integrated into existing guidelines for the management of tuberculosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Digital imaging methods are a centrepiece for diagnosis and management of macular disease. A recently developed imaging device is composed of simultaneous confocal scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT). By means of clinical samples the benefit of this technique concerning diagnostic and therapeutic follow-up will be assessed. METHODS: The combined OCT-SLO-System (Ophthalmic Technologies Inc., Toronto, Canada) allows for confocal en-face fundus imaging and high resolution OCT scanning at the same time. OCT images are obtained from transversal line scans. One light source and the identical scanning rate yield a pixel-to-pixel correspondence of images. Three-dimensional thickness maps are derived from C-scan stacking. RESULTS: We followed-up patients with cystoid macular edema, pigment epithelium detachment, macular hole, venous branch occlusion, and vitreoretinal tractions during their course of therapy. The new imaging method illustrates the reduction of cystoid volume, e.g. after intravitreal injections of either angiostatic drugs or steroids. C-scans are used for appreciation of lesion diameters, visualisation of pathologies involving the vitreoretinal interface, and quantification of retinal thickness change. CONCLUSION: The combined OCT-SLO system creates both topographic and tomographic images of the retina. New therapeutic options can be followed-up closely by observing changes in lesion thickness and cyst volumes. For clinical use further studies are needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Complete correction of Tetralogy of Fallot, the most common cyanotic congenital heart defect, has now become routine. However, late residual lesions, primarily chronic pulmonary valve insufficiency, may have a negative impact on right-ventricular function, leading to the need for reoperation to insert a competent valve at the right-ventricular outflow. The diagnostic modalities pertaining to the failing right ventricle, the timing for eventual reintervention and the various surgical reconstruction possibilities of the right-ventricular outflow tract are still controversial and evolving, and are reviewed with a brief overview on current trends and future outlooks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECT: The aim of our study was to demonstrate the image quality of the new device using human cadavers, extending the horizon of available imaging modalities in forensic medicine. MATERIALS AND METHODS: Six human cadavers were examined, revealing C-arm data sets of the head, neck thorax, abdomen and pelvis. High-resolution mode was performed with 500 fluoroscopy shots during a 190 degrees orbital movement with a constant tube voltage of 100 kV and a current of 4.6 mA. Based on these data sets subsequent three-dimensional reconstructions were generated. RESULTS: Reconstructed data sets revealed high-resolution images of all skeletal structures in a near-CT quality. The same image quality was available in all reconstruction planes. Artefacts caused by restorative dental materials are less accentuated in CBCT data sets. The system configuration was not powerful enough to generate sufficient images of intracranial structures. CONCLUSION: After the here-demonstrated encouraging preliminary results, the forensic indications that would be suitable for imaging with a 3D C-arm have to be defined. Promising seems the visualization local limited region of interest as the cervical spine or the facial skeleton.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eosinophils and gastrointestinal tract interact in an intimate and enigmatic relationship. Under inflammatory conditions, eosinophil infiltration in the gastrointestinal tract is a common feature of numerous eosinophilic gastrointestinal disorders (EGIDs). EGIDs are disorders, for which the diagnosis is relatively difficult. Nevertheless, some common laboratory techniques are currently used for their diagnosis and disease monitoring. Besides eosinophils, mast cells and T cells have also been suggested to play a role in the pathogenesis of these disorders. Here, we review the pathogenesis and common laboratory approaches applied for their diagnosis, in particular eosinophil and mast cell markers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Autoantibodies play a key role in diagnostic laboratories as markers of autoimmune diseases. In addition to their role as markers they mediate diverse effects in vivo. Autoantibodies with protective effect have been described. Natural protective IgM autoantibodies against tumour-antigens of malignant cells or their precursors may contribute to increased survival rates of carcinoma patients. In a mouse model of systemic lupus erythematosus it has been shown that anti-dsDNA IgM autoantibodies protect from glomerular damage. In contrast, a direct pathogenic role of autoantibodies has been well established e.g. in myasthenia gravis or in Goodpasture syndrome. Similarly autoantibodies against SSA Ro52 are detrimental in neonatal lupus erythematosus with congenital heart block. Moreover, putatively protective autoantibodies may become pathogenic during the course of the disease such as the onconeuronal autoantibodies whose pathogenicity depends on their compartmentalisation. In patients with paraneoplastic syndromes tumour cells express proteins that are also naturally present in the brain. Anti-tumour autoantibodies which temporarily suppress tumour growth can provoke an autoimmune attack on neurons once having crossed the blood-brain barrier and cause specific neurological symptoms. Only a restricted number of autoantibodies are useful follow-up markers for the effectiveness of treatment in autoimmune diseases. Certain autoantibodies hold prognostic value and appear years or even decades before the diagnosis of disease such as the antimitochondrial antibodies in primary biliary cirrhosis or anti-citrullinated protein (CCP)-antibodies in rheumatoid arthritis. It is crucial to know whether the autoantibodies in question recognise linear or conformational epitopes in order to choose the appropriate detection methods. Indirect immunofluorescence microscopy remains a very useful tool for confirmation of results of commercially available immunoassays and for detection of special and rare autoantibodies that otherwise often remain undetected. Standardisation of autoimmune diagnostics is still underway and requires joint efforts by laboratories, clinicians and industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Several technical advances in thoracic aortic surgery, such as the use of antegrade cerebral perfusion, avoidance of cross-clamping and the application of glue, have beneficially influenced postoperative outcome. The aim of the present study was to analyse the impact of these developments on outcome of patients undergoing surgery of the thoracic aorta. METHODS AND RESULTS: Between January 1996 and December 2005, 835 patients (37.6%) out of 2215 aortic patients underwent surgery on the thoracic ascending aorta or the aortic arch at our institution. All in-hospital data were assessed. Two hundred and forty-one patients (28.8%) suffered from acute type A dissection (AADA). Overall aortic caseload increased from 41 patients in 1996 to 141 in 2005 (+339%). The increase was more pronounced for thoracic aortic aneurysms (TAA) (+367.9%), than for acute type A aortic dissections (+276.9%). Especially in TAA, combined procedures increased and the amount of patients with impaired left ventricular function (EF <50%) raised up from 14% in 1996 to 24% in 2005. Average age remained stable. Logistic regression curve revealed a significant decrease in mortality (AADA) and in the overall incidence of neurological deficits. CONCLUSIONS: Technical advances in the field of thoracic aortic surgery lead to a decrease of mortality and morbidity, especially in the incidence of adverse neurological events, in a large collective of patients. Long-term outcome and quality of life are better, since antegrade cerebral perfusion has been introduced.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To systematically appraise the impact of mechanical/technical risk factors on implant-supported reconstructions. MATERIAL AND METHODS: A MEDLINE (PubMed) database search from 1966 to April 2008 was conducted. The search strategy was a combination of MeSH terms and the key words: design, dental implant(s), risk, prosthodontics, fixed prosthodontics, fixed partial denture(s), fixed dental prosthesis (FDP), fixed reconstruction(s), oral rehabilitation, bridge(s), removable partial denture(s), overdenture(s). Randomized controlled trials, controlled trials, and prospective and retrospective cohort studies with a mean follow-up of at least 4 years were included. The material evaluated in each study had to include cases with/without exposure to the risk factor. RESULTS: From 3,568 articles, 111 were selected for full text analysis. Of the 111 articles, 33 were included for data extraction after grouping the outcomes into 10 risk factors: type of retentive elements supporting overdentures, presence of cantilever extension(s), cemented versus screw-retained FDPs, angled/angulated abutments, bruxism, crown/implant ratio, length of the suprastructure, prosthetic materials, number of implants supporting an FDP, and history of mechanical/technical complications. CONCLUSIONS: The absence of a metal framework in overdentures, the presence of cantilever extension(s) > 15 mm and of bruxism, the length of the reconstruction, and a history of repeated complications were associated with increased mechanical/technical complications. The type of retention, the presence of angled abutments, the crown-implant ratio, and the number of implants supporting an FDP were not associated with increased mechanical/technical complications. None of the mechanical/technical risk factors had an impact on implant survival and success rates.