70 resultados para Sulfate ferreux--Pacifique Nord


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The SLC13 family comprises five genes (SLC13A1, SLC13A2, SLC13A3, SLC13A4, and SLC13A5) encoding structurally related multi-spanning transporters (8-13 transmembrane domains) with orthologues found in prokaryotes and eukaryotes. Mammalian SLC13 members mediate the electrogenic Na(+)-coupled anion cotransport at the plasma membrane of epithelial cells (mainly kidney, small intestine, placenta and liver) or cells of the central nervous system. While the two SLC13 cotransporters NaS1 (SLC13A1) and NaS2 (SLC13A4) transport anions such sulfate, selenate and thiosulfate, the three other SLC13 members, NaDC1 (SLC13A2), NaCT (SLC13A5) and NaDC3 (SLC13A3), transport di- and tri-carboxylate Krebs cycle intermediates such as succinate, citrate and α-ketoglutarate. All these transporters play a variety of physiological and pathophysiological roles in the different organs. Thus, the purpose of this review is to summarize the roles of SLC13 members in human physiology and pathophysiology and what the therapeutic perspectives are. We have also described the most recent advances on the structure, expression, function and regulation of SLC13 transporters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Ethyl glucuronide (EtG) and ethyl sulfate (EtS) are non-oxidative minor metabolites of ethanol. They are detectable in various body fluids shortly after initial consumption of ethanol and have a longer detection time frame than the parent compound. They are regarded highly sensitive and specific markers of recent alcohol uptake. This study evaluates the determination of EtG and EtS from dried blood spots (DBS), a simple and cost-effective sampling method that would shorten the time gap between offense and blood sampling and lead to a better reflectance of the actual impairment. METHODS: For method validation, EtG and EtS standard and quality control samples were prepared in fresh human heparinized blood and spotted on DBS cards, then extracted and measured by an LC-ESI-MS/MS method. Additionally, 76 heparinized blood samples from traffic offense cases were analyzed for EtG and EtS as whole blood and as DBS specimens. The results from these measurements were then compared by calculating the respective mean values, by a matched-paired t test, by a Wilcoxon test, and by Bland-Altman and Mountain plots. RESULTS AND DISCUSSION: Calibrations for EtG and EtS in DBS were linear over the studied calibration range. The precision and accuracy of the method met the requirements of the validation guidelines that were employed in the study. The stability of the biomarkers stored as DBS was demonstrated under different storage conditions. The t test showed no significant difference between whole blood and DBS in the determination of EtG and EtS. In addition, the Bland-Altman analysis and Mountain plot confirmed that the concentration differences that were measured in DBS specimens were not relevant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Herbal and dietary supplements are widely used as measures to improve and preserve health and well-being. Among the bestselling preparations are dietary supplement containing glucosamine and chondroitine sulfate taken to improve symptoms of osteoarthritis. METHODS AND RESULTS We here present a case of a male patient with biopsy-proven acute and severe autoimmune hepatitis subsequent to intake of a preparation containing glucosamine and chondroitine sulfate. Response to steroids was favorable and resulted in complete remission of the patient. Diagnostic work-up of the case revealed no other possible cause of liver injury, and causality assessment using the Roussel Uclaf Causality Assessment Method (RUCAM) resulted in a possible causal relationship between intake of glucosamine and chondroitine sulfate and the adverse hepatic reaction. CONCLUSION The present case recalls that products containing glucosamine and chondroitine sulfate can occasionally cause acute liver injury mimicking autoimmune hepatitis, and reminds of the potential dangers of compounds with poor efficacy and ill-defined safety records.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thin and ultrathin cryosections of mouse cornea were labeled with affinity-purified antibodies directed against either laminin, its central segments (domain 1), the end of its long arm (domain 3), the end of one of its short arms (domain 4), nidogen, or low density heparan sulfate proteoglycan. All basement membrane proteins are detected by indirect immunofluorescence exclusively in the epithelial basement membrane, in Descemet's membrane, and in small amorphous plaques located in the stroma. Immunoelectron microscopy using the protein A-gold technique demonstrated laminin domain 1 and nidogen in a narrow segment of the lamina densa at the junction to the lamina lucida within the epithelial basement membrane. Domain 3 shows three preferred locations at both the cellular and stromal boundaries of the epithelial basement membrane and in its center. Domain 4 is located predominantly in the lamina lucida and the adjacent half of the lamina densa. The low density heparan sulfate proteoglycan is found all across the basement membrane showing a similar uniform distribution as with antibodies against the whole laminin molecule. In Descemet's membrane an even distribution was found with all these antibodies. It is concluded that within the epithelial basement membrane the center of the laminin molecule is located near the lamina densa/lamina lucida junction and that its long arm favors three major orientations. One is close to the cell surface indicating binding to a cell receptor, while the other two are directed to internal matrix structures. The apparent codistribution of laminin domain 1 and nidogen agrees with biochemical evidence that nidogen binds to this domain.