246 resultados para Subaortic Stenosis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atrial fibrillation (AF) is an important risk factor for stroke and is common among elderly patients undergoing transcatheter aortic valve implantation. The aim of this study was to assess the impact of AF on clinical outcomes among patients undergoing transcatheter aortic valve implantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stroke is the most debilitating cardiovascular event. It has a variety of causes that may be present simultaneously. In young or otherwise healthy people, the search for a patent foramen ovale (PFO) has become standard. In stroke of the elderly, atherosclerosis and atrial fibrillation are in the foreground but the PFO should not be ignored. The risk of a PFO-related stroke over time is controversial and so is its prevention by device closure. The association of proximal aortic plaques in arteries subtending the brain and stroke is considered strong, ignoring that it is as putative as that of the PFO. Statins can prevent progression of such plaques. Antiplatelet agents in asymptomatic and surgical endarterectomy in symptomatic patients or highly ulcerated lesions are the treatment of choice. Stenting with protection devices was shown competitive in selected patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In adults with congenital heart disease and a systemic right ventricle, subaortic ventricular systolic dysfunction is common. Echocardiographic assessment of systolic right ventricular (RV) function in these patients is important but challenging. The aim of the present study was to assess the reliability of conventional echocardiographic RV functional parameters to quantify the systolic performance of a subaortic right ventricle. We compared 56 contemporary echocardiograms and cardiac magnetic resonance studies in 37 adults, aged 26.9 ± 7.4 years, with complete transposition and a subaortic right ventricle. The fractional area change (FAC), lateral tricuspid annular plane systolic excursion, lateral RV systolic motion velocities by tissue Doppler, RV myocardial performance index, and the rate of systolic RV pressure increase (dp/dt) measured across the tricuspid regurgitant jet were assessed by echocardiography and correlated with the cardiac magnetic resonance-derived RV ejection fraction (EF). The mean RVEF was 48.0 ± 7.8%. FAC (r(2) = 0.206, p = 0.001) and dp/dt (r(2) = 0.173, p = 0.009) significantly correlated with RVEF, and the other nongeometric echocardiographic parameters failed to show a significant correlation with RVEF by linear regression analysis. FAC <33% and dp/dt <1,000 mm Hg/s identified a RVEF of <50% with a sensitivity of 77% and 69% and a specificity of 58% and 87%, respectively. In conclusion, in patients with a systemic right ventricle, routine nongeometric echocardiographic parameters of RV function correlated weakly with cardiac magnetic resonance-derived EF. RV FAC and the measurement of the rate of systolic RV pressure increase (dp/dt) should be preferentially used to assess systemic systolic function in adult patients with a subaortic right ventricle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Renovascular hypertension is due to reduced renal parenchymal perfusion. The correct diagnosis can be difficult. It is important to note that the demonstration of renal artery stenosis in a patient with hypertension does not necessarily constitute renovascular hypertension. Often, clinically nonsignificant and asymptomatic renal artery stenosis are found in patients with essential hypertension, or renal failure of other origin. Renovascular disease is a complex disorder with various clinical presentations. In patients with significant renovascular hypertension plasma renin is increased. For this reason the therapy aims to block the renin-angiotensin-aldosterone system. Bilateral renal artery stenosis causes renal sodium retention. In this situation a diuretic drug has to be added to the therapy. Endovascular or surgical therapy has to be considered in patients with flash pulmonary edema or fibromuscular dysplasia. The control of cardiovascular risk factors is important.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To assess the long-term results of double bicanalicular silicone tubes in canalicular (presaccal) stenosis of the nasolacrimal duct system, a retrospective follow-up was performed on patients operated between 1992 and 2002. Forty-five patients were included in the study, 44 of whom had eyes with canalicular stenosis (primary dacryocystorhinostomy), 4 with congenital agenesis of the lacrimal duct system, and 3 cases after primary external dacryocystorhinostomy. Double bicanalicular silicone tubes were inserted, fixed in the vestibulum nasi, and left in place as long-term space holders. Of the 51 endonasal primary dacryocystorhinostomies with canalicular stenosis, 32 (63%) became symptom-free after one procedure. Nineteen (37%) patients had a relapse. Double silicone bicanalicular tube insertion as long-term spacers in canalicular stenoses has a number of advantages, but canalicular stenoses still remain a challenging area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: The goal of this study was to assess the prevalence of left ventricular (LV) hypertrophy in patients with aortic stenosis late (>6 months) after aortic valve replacement and its impact on cardiac-related morbidity and mortality. METHODS AND RESULTS: In a single tertiary centre, echocardiographic data of LV muscle mass were collected. Detailed information of medical history and angiographic data were gathered. Ninety-nine of 213 patients (46%) had LV hypertrophy late (mean 5.8 +/- 5.4 years) after aortic valve replacement. LV hypertrophy was associated with impaired exercise capacity, higher New York Heart Association dyspnoea class, a tendency for more frequent chest pain expressed as higher Canadian Cardiovascular Society class, and more rehospitalizations. 24% of patients with normal LV mass vs. 39% of patients with LV hypertrophy reported cardiac-related morbidity (p = 0.04). In a multivariate logistic regression model, LV hypertrophy was an independent predictor of cardiac-related morbidity (odds ratio 2.31, 95% CI 1.08 to 5.41), after correction for gender, baseline ejection fraction, and coronary artery disease and its risk factors. Thirty seven deaths occurred during a total of 1959 patient years of follow-up (mean follow-up 9.6 years). Age at aortic valve replacement (hazard ratio 1.85, 95% CI 1.39 to 2.47, for every 5 years increase in age), coexisting coronary artery disease at the time of surgery (hazard ratio 3.36, 95% CI 1.31 to 8.62), and smoking (hazard ratio 4.82, 95% CI 1.72 to 13.45) were independent predictors of overall mortality late after surgery, but not LV hypertrophy. CONCLUSIONS: In patients with aortic valve replacement for isolated aortic stenosis, LV hypertrophy late after surgery is associated with increased morbidity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe the case of 77-year-old woman who underwent five coronary angiographies in 9 months due to in-stent re-stenosis of Cypher-Stents, and who finally required coronary artery bypass grafting surgery. Preoperative investigations revealed a significant internal carotid stenosis, which was due to a fractured and embolized Cypher-Stent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Multislice computed tomography (MSCT) is a promising noninvasive method of detecting coronary artery disease (CAD). However, most data have been obtained in selected series of patients. The purpose of the present study was to investigate the accuracy of 64-slice MSCT (64 MSCT) in daily practice, without any patient selection. METHODS AND RESULTS: Using 64-slice MSCT coronary angiography (CTA), 69 consecutive patients, 39 (57%) of whom had previously undergone stent implantation, were evaluated. The mean heart rate during scan was 72 beats/min, scan time 13.6 s and the amount of contrast media 72 mL. The mean time span between invasive coronary angiography (ICAG) and CTA was 6 days. Significant stenosis was defined as a diameter reduction of > 50%. Of 966 segments, 884 (92%) were assessable. Compared with ICAG, the sensitivity of CTA to diagnose significant stenosis was 90%, specificity 94%, positive predictive value (PPV) 89% and negative predictive value (NPV) 95%. With regard to 58 stented lesions, the sensitivity, specificity, PPV and NPV were 93%, 96%, 87% and 98%, respectively. On the patient-based analysis, the sensitivity, specificity, PPV and NPV of CTA to detect CAD were 98%, 86%, 98% and 86%, respectively. Eighty-two (8%) segments were not assessable because of irregular rhythm, calcification or tachycardia. CONCLUSION: Sixty-four-MSCT has a high accuracy for the detection of significant CAD in an unselected patient population and therefore can be considered as a valuable noninvasive technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: We sought to determine both the procedural performance and safety of percutaneous implantation of the second (21-French [F])- and third (18-F)-generation CoreValve aortic valve prosthesis (CoreValve Inc., Irvine, California). BACKGROUND: Percutaneous aortic valve replacement represents an emerging alternative therapy for high-risk and inoperable patients with severe symptomatic aortic valve stenosis. METHODS: Patients with: 1) symptomatic, severe aortic valve stenosis (area <1 cm2); 2) age > or =80 years with a logistic EuroSCORE > or =20% (21-F group) or age > or =75 years with a logistic EuroSCORE > or =15% (18-F group); or 3) age > or =65 years plus additional prespecified risk factors were included. Introduction of the 18-F device enabled the transition from a multidisciplinary approach involving general anesthesia, surgical cut-down, and cardiopulmonary bypass to a truly percutaneous approach under local anesthesia without hemodynamic support. RESULTS: A total of 86 patients (21-F, n = 50; 18-F, n = 36) with a mean valve area of 0.66 +/- 0.19 cm2 (21-F) and 0.54 +/- 0.15 cm2 (18-F), a mean age of 81.3 +/- 5.2 years (21-F) and 83.4 +/- 6.7 years (18-F), and a mean logistic EuroSCORE of 23.4 +/- 13.5% (21-F) and 19.1 +/- 11.1% (18-F) were recruited. Acute device success was 88%. Successful device implantation resulted in a marked reduction of aortic transvalvular gradients (mean pre 43.7 mm Hg vs. post 9.0 mm Hg, p < 0.001) with aortic regurgitation grade remaining unchanged. Acute procedural success rate was 74% (21-F: 78%; 18-F: 69%). Procedural mortality was 6%. Overall 30-day mortality rate was 12%; the combined rate of death, stroke, and myocardial infarction was 22%. CONCLUSIONS: Treatment of severe aortic valve stenosis in high-risk patients with percutaneous implantation of the CoreValve prosthesis is feasible and associated with a lower mortality rate than predicted by risk algorithms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This study was designed to compare the long-term clinical outcome of coronary artery bypass grafting (CABG) with intracoronary stenting of patients with isolated proximal left anterior descending coronary artery. BACKGROUND: Although numerous trials have compared coronary angioplasty with bypass surgery, none assessed the clinical evaluation in the long term. METHODS: We evaluated the 10-year clinical outcome in the SIMA (Stent versus Internal Mammary Artery grafting) trial. Patients were randomly assigned to stent implantation versus CABG. RESULTS: Of 123 randomized patients, 59 underwent CABG and 62 received a stent (2 patients were excluded). Follow-up after 10 years was obtained for 98% of the randomized patients. Twenty-six patients (42%) in the percutaneous coronary intervention group and 10 patients (17%) in the CABG group reached an end point (p < 0.001). This difference was due to a higher need for additional revascularization. The incidences of death and myocardial infarction were identical at 10%. Progression of the disease requiring additional revascularization was rare (5%) and was similar for the 2 groups. Stent thrombosis occurred in 2 patients (3%). Angina functional class showed no significant differences between the 2 groups. CONCLUSIONS: Both stent implantation and CABG are safe and highly effective in relieving symptoms in patients with isolated, proximal left anterior descending coronary artery stenosis. Stenting with bare-metal stents is associated with a higher need for repeat interventions. The long-term prognosis for these patients is excellent with either mode of revascularization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lumbar spinal stenosis is a frequent indication for spinal surgery. The predictive quality of treadmill testing and MRI for diagnostic verification is not yet clearly defined. Aim of the current study was to assess correlations between treadmill testing and MRI findings in the lumbar spine. Twenty-five patients with lumbar spinal stenosis were prospectively examined. Treadmill tests were performed and the area of the dural sac and neuroforamina was examined with MRI for the narrowest spinal segment. VAS and ODI were used for clinical assessment. The median age of the patients was 67 years. In the narrowest spinal segment the median area of the dural sac was 91 mm(2). The median ODI was 66 per cent. The median walking distance in the treadmill test was 70 m. The distance reached in the treadmill test correlated with the area of the dural sac (Spearman's rho = 0.53) and ODI (rho = -0.51), but not with the area of the neuroforamina and VAS. The distance reached in the treadmill test predicts the grade of stenosis in MRI but has a limited diagnostic importance for the level of clinical symptoms in lumbar spinal stenosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Sialendoscopy and sialoMRI enables diagnosis of salivary gland obstructive pathologies, such as lithiasis, stenosis, and dilatations. Therefore, a classification of these pathologies is needed, allowing large series comparisons, for better diagnosis and treatment of salivary pathologies. MATERIAL AND METHODS: With help from people from the European Sialendoscopy Training Center (ESTC), the results of sialographies, sialoMRI and sialendoscopies, a comprehensive classification of obstructive salivary pathologies is described, based on the absence or presence of lithiasis (L), stenosis (S), and dilatation (D) ("LSD" classification). DISCUSSION: It appears that a classification of salivary gland obstructive pathologies should be described. We hope it will be widely used and of course criticized to be improved and to compare the results of salivary gland diagnostic methods, such as sialography and sialendoscopy, and also the results and indications for salivary gland therapeutic methods, such as lithotripsy, sialendoscopy, and/or open surgery.