51 resultados para Study skills--Evaluation.


Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND Conventional factors do not fully explain the distribution of cardiovascular outcomes. Biomarkers are known to participate in well-established pathways associated with cardiovascular disease, and may therefore provide further information over and above conventional risk factors. This study sought to determine whether individual and/or combined assessment of 9 biomarkers improved discrimination, calibration and reclassification of cardiovascular mortality. METHODS 3267 patients (2283 men), aged 18-95 years, at intermediate-to-high-risk of cardiovascular disease were followed in this prospective cohort study. Conventional risk factors and biomarkers were included based on forward and backward Cox proportional stepwise selection models. RESULTS During 10-years of follow-up, 546 fatal cardiovascular events occurred. Four biomarkers (interleukin-6, neutrophils, von Willebrand factor, and 25-hydroxyvitamin D) were retained during stepwise selection procedures for subsequent analyses. Simultaneous inclusion of these biomarkers significantly improved discrimination as measured by the C-index (0.78, P = 0.0001), and integrated discrimination improvement (0.0219, P<0.0001). Collectively, these biomarkers improved net reclassification for cardiovascular death by 10.6% (P<0.0001) when added to the conventional risk model. CONCLUSIONS In terms of adverse cardiovascular prognosis, a biomarker panel consisting of interleukin-6, neutrophils, von Willebrand factor, and 25-hydroxyvitamin D offered significant incremental value beyond that conveyed by simple conventional risk factors.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND Aortic dissection is a severe pathological condition in which blood penetrates between layers of the aortic wall and creates a duplicate channel - the false lumen. This considerable change on the aortic morphology alters hemodynamic features dramatically and, in the case of rupture, induces markedly high rates of morbidity and mortality. METHODS In this study, we establish a patient-specific computational model and simulate the pulsatile blood flow within the dissected aorta. The k-ω SST turbulence model is employed to represent the flow and finite volume method is applied for numerical solutions. Our emphasis is on flow exchange between true and false lumen during the cardiac cycle and on quantifying the flow across specific passages. Loading distributions including pressure and wall shear stress have also been investigated and results of direct simulations are compared with solutions employing appropriate turbulence models. RESULTS Our results indicate that (i) high velocities occur at the periphery of the entries; (ii) for the case studied, approximately 40% of the blood flow passes the false lumen during a heartbeat cycle; (iii) higher pressures are found at the outer wall of the dissection, which may induce further dilation of the pseudo-lumen; (iv) highest wall shear stresses occur around the entries, perhaps indicating the vulnerability of this region to further splitting; and (v) laminar simulations with adequately fine mesh resolutions, especially refined near the walls, can capture similar flow patterns to the (coarser mesh) turbulent results, although the absolute magnitudes computed are in general smaller. CONCLUSIONS The patient-specific model of aortic dissection provides detailed flow information of blood transport within the true and false lumen and quantifies the loading distributions over the aorta and dissection walls. This contributes to evaluating potential thrombotic behavior in the false lumen and is pivotal in guiding endovascular intervention. Moreover, as a computational study, mesh requirements to successfully evaluate the hemodynamic parameters have been proposed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

STUDY OBJECTIVE To determine the effectiveness of an esophageal doppler device to non-invasively detect experimental pseudo-electromechanical dissociation (pseudo-EMD). DESIGN Prospective, controlled, laboratory investigation using an asphyxial canine cardiac arrest model and a newly-developed esophageal flat-flow probe doppler unit. INTERVENTIONS Mongrel dogs (20) were instrumented for hemodynamic monitoring. The esophageal doppler probe was placed in the distal esophagus of each animal. Electromechanical dissociation (EMD) was induced by clamping the endotracheal tube. MEASUREMENTS AND MAIN RESULTS A period of pseudo-EMD was defined as the time where cardiac contractility was present, measured by a micromanometer tipped thoracic aortic catheter, without concurrent femoral pulses by palpation. The pseudo-EMD period could be produced consistently in all 20 animals. The characteristic doppler flow sounds were easily heard using the esophageal device in all animals. The time from endotracheal tube clamping until loss of femoral pulses was 622 +/- 96 s; until loss of radial artery doppler signals was 616 +/- 92 s; until loss of esophageal doppler signals was 728 +/- 88 s; and until loss of aortic fluctuations by thoracic aortic catheter was 728 +/- 82 s. The times to loss of esophageal doppler sounds and loss of aortic fluctuations were not significantly different. However, they were significantly longer than the time to loss of femoral pulses (P < 0.02). CONCLUSIONS The canine asphyxial EMD model can be used for short experimental studies of pseudo-EMD. Pseudo-EMD can be consistently and non-invasively detected with this esophageal doppler device. The device is as reliable as a micromanometer tipped aortic arch catheter in detecting pseudo-EMD. The doppler device could potentially be useful in improving recognition of near cardiac arrest in pre-hospital and emergency department settings. Further research on the utility of this device in other models of low-flow states should be performed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the suitability of a minipig model for the study of bone healing and osseointegration of dental implants following bone splitting and expansion of narrow ridges. MATERIAL AND METHODS In four minipigs, the mandibular premolars and first molars were extracted together with removal of the buccal bone plate. Three months later, ridge splitting and expansion was performed with simultaneous placement of three titanium implants per quadrant. On one side of the mandible, the expanded bone gap between the implants was filled with an alloplastic biphasic calcium phosphate (BCP) material, while the gap on the other side was left unfilled. A barrier membrane was placed in half of the quadrants. After a healing period of 6 weeks, the animals were sacrificed for histological evaluation. RESULTS In all groups, no bone fractures occurred, no implants were lost, all 24 implants were osseointegrated, and the gap created by bone splitting was filled with new bone, irrespective of whether BCP or a barrier membrane was used. Slight exposure of five implants was observed, but did not lead to implant loss. The level of the most coronal bone-to-implant contact varied without being dependent on the use of BCP or a barrier membrane. In all groups, the BCP particles were not present deep in the bone-filled gap. However, BCP particles were seen at the crestal bone margin, where they were partly integrated in the new bone. CONCLUSIONS This new minipig model holds great promise for studying experimental ridge splitting/expansion. However, efforts must be undertaken to reduce implant exposure and buccal bone resorption.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the correlation between clinical measures of disease activity and a ultrasound (US) scoring system for synovitis applied by many different ultrasonographers in a daily routine care setting within the Swiss registry for RA (SCQM) and further to determine the sensitivity to change of this US Score. METHODS One hundred and eight Swiss rheumatologists were trained in performing the Swiss Sonography in Arthritis and Rheumatism (SONAR) score. US B-mode and Power Doppler (PwD) scores were correlated with DAS28 and compared between the clinical categories in a cross-sectional cohort of patients. In patients with a second US (longitudinal cohort), we investigated if change in US score correlated with change in DAS and evaluated the responsiveness of both methods. RESULTS In the cross-sectional cohort with 536 patients, correlation between the B-mode score and DAS28 was significant but modest (Pearson coefficient r = 0.41, P < 0.0001). The same was true for the PwD score (r = 0.41, P < 0.0001). In the longitudinal cohort with 183 patients we also found a significant correlation between change in B-mode and in PwD score with change in DAS28 (r = 0.54, P < 0.0001 and r = 0.46, P < 0.0001, respectively). Both methods of evaluation (DAS and US) showed similar responsiveness according to standardized response mean (SRM). CONCLUSIONS The SONAR Score is practicable and was applied by many rheumatologists in daily routine care after initial training. It demonstrates significant correlations with the degree of as well as change in disease activity as measured by DAS. On the level of the individual, the US score shows many discrepancies and overlapping results exist.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND Children and adolescents are at high risk of sustaining fractures during growth. Therefore, epidemiological assessment is crucial for fracture prevention. The AO Comprehensive Injury Automatic Classifier (AO COIAC) was used to evaluate epidemiological data of pediatric long bone fractures in a large cohort. METHODS Data from children and adolescents with long bone fractures sustained between 2009 and 2011, treated at either of two tertiary pediatric surgery hospitals in Switzerland, were retrospectively collected. Fractures were classified according to the AO Pediatric Comprehensive Classification of Long Bone Fractures (PCCF). RESULTS For a total of 2716 patients (60% boys), 2807 accidents with 2840 long bone fractures (59% radius/ulna; 21% humerus; 15% tibia/fibula; 5% femur) were documented. Children's mean age (SD) was 8.2 (4.0) years (6% infants; 26% preschool children; 40% school children; 28% adolescents). Adolescent boys sustained more fractures than girls (p < 0.001). The leading cause of fractures was falls (27%), followed by accidents occurring during leisure activities (25%), at home (14%), on playgrounds (11%), and traffic (11%) and school accidents (8%). There was boy predominance for all accident types except for playground and at home accidents. The distribution of accident types differed according to age classes (p < 0.001). Twenty-six percent of patients were classed as overweight or obese - higher than data published by the WHO for the corresponding ages - with a higher proportion of overweight and obese boys than in the Swiss population (p < 0.0001). CONCLUSION Overall, differences in the fracture distribution were sex and age related. Overweight and obese patients seemed to be at increased risk of sustaining fractures. Our data give valuable input into future development of prevention strategies. The AO PCCF proved to be useful in epidemiological reporting and analysis of pediatric long bone fractures.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A career workshop that applies models of the Cognitive Information Processing Approach (Sampson, Reardon, Peterson, & Lenz, 2004) and incorporates critical ingredients (Brown and Ryan Krane, 2000) to promote the career choice readiness of young adolescents was developed and evaluated with 334 Swiss students in seventh grade applying a Solomon four group design with a three-month follow-up. Participants significantly increased their performance in terms of career decidedness, career planning, career exploration, and vocational identity. Implications for evaluation research and counselling practice are presented.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Budgets are often simultaneously used for the conflicting purposes of planning and performance evaluation. While economic theory suggests that firms should use separate budgets for conflicting purposes this contrasts with existing evidence that firms rarely do so. We address two open questions related to these observations in an experiment. Specifically, we investigate how a planning task that is in conflict with the performance evaluation task affects behavior in budget negotiations and their outcomes. Additionally, we analyze whether a single budget can be effectively used for both purposes compared to two separate budgets. We develop theory to predict that adding a planning task that is in conflict with the superior’s performance evaluation task increases the subordinate’s cooperation in and after the negotiation of a performance evaluation budget. Moreover, we predict that subordinate cooperation increases even more when the superior is restricted to use a single budget for both purposes. Our results broadly support our hypotheses. Specifically, we find that when budgets are used for both planning and performance evaluation, this increases the subordinate’s budget proposals during the negotiation and his performance after the negotiation. These effects tend to be even larger when the superior is restricted to a single budget rather than separate budgets for planning and performance evaluation, particularly with respect to subordinate performance. In our experimental setting, the benefits of increased subordinate cooperation even more than offset the loss in flexibility from the superior’s restriction to a single budget. The results of this study add to the understanding of the interdependencies of conflicting budgeting purposes and contribute to explain why firms often use a single budget for multiple purposes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: Since 2011, the new national final examination in human medicine has been implemented in Switzerland, with a structured clinical-practical part in the OSCE format. From the perspective of the national Working Group, the current article describes the essential steps in the development, implementation and evaluation of the Federal Licensing Examination Clinical Skills (FLE CS) as well as the applied quality assurance measures. Finally, central insights gained from the last years are presented. Methods: Based on the principles of action research, the FLE CS is in a constant state of further development. On the foundation of systematically documented experiences from previous years, in the Working Group, unresolved questions are discussed and resulting solution approaches are substantiated (planning), implemented in the examination (implementation) and subsequently evaluated (reflection). The presented results are the product of this iterative procedure. Results: The FLE CS is created by experts from all faculties and subject areas in a multistage process. The examination is administered in German and French on a decentralised basis and consists of twelve interdisciplinary stations per candidate. As important quality assurance measures, the national Review Board (content validation) and the meetings of the standardised patient trainers (standardisation) have proven worthwhile. The statistical analyses show good measurement reliability and support the construct validity of the examination. Among the central insights of the past years, it has been established that the consistent implementation of the principles of action research contributes to the successful further development of the examination. Conclusion: The centrally coordinated, collaborative-iterative process, incorporating experts from all faculties, makes a fundamental contribution to the quality of the FLE CS. The processes and insights presented here can be useful for others planning a similar undertaking. Keywords: national final examination, licensing examination, summative assessment, OSCE, action research

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This chapter examines the state of evaluation training programs at European universities in 2012. It summarises the results of a survey that was conducted among representatives of 15 programs located in Belgium, Denmark, Greece, Italy, France, The Netherlands, Romania, Spain, Sweden and Switzerland. Some basic information about the programs are reported (e.g. organising body, degree offered, admission requirements, duration in months, price), as well as the programs’ core subjects and learning outcomes. The chapter discusses the challenges for university-based study programmes that arise from the current situation of the evaluation profession, and concludes with some thoughts on education and training as requirements for professionalisation in evaluation

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: To compare the biomechanical properties of a ventral transarticular lag screw fixation technique, a new dorsal atlantoaxial instability (AAI) clamp, and a new ventral AAI hook plate under sagittal shear loading after transection of the ligaments of the atlantoaxial joint. STUDY DESIGN: Cadaveric biomechanical study. ANIMALS: Canine cadavers (n = 10). MATERIALS AND METHODS: The occipitoatlantoaxial region of Beagles euthanatized for reasons unrelated to the study was prepared leaving only ligamentous structures and the joint capsules between the first 2 cervical vertebrae (C1 and C2). The atlanto-occipital joints were stabilized with 2 transarticular diverging positive threaded K-wires. The occipital bone and the caudal end of C2 were embedded in polymethylmethacrylate and loaded in shear to a force of 50 Newtons. The range of motion (ROM) and neutral zone (NZ) of the atlantoaxial joint were determined after 3 loading cycles with atlantoaxial ligaments intact, after ligament transection, and after fixation with each implant. The testing order of implants was randomly assigned. The implants tested last were subjected to failure testing. RESULTS: All stabilization procedures decreased the ROM and NZ of the atlantoaxial joint compared to transected ligament specimens. Only stabilization with transarticular lag screws and ventral plates produced a significant reduction of ROM compare to intact specimens. CONCLUSION: Fixation with transarticular lag screws and a ventral hook plate was biomechanically similar and provided more rigidity compared to dorsal clamp fixation. Further load cycling to failure tests and clinical studies are required before making clinical recommendations.