38 resultados para SEC interpretations of Rule 14a-8(i)(10)
Resumo:
Insect bite hypersensitivity (IBH) is an allergic dermatitis of horses caused by IgE-mediated reactions to bites of insects of the genus Culicoides. IBH does not occur in Iceland due to the absence of Culicoides. However, Icelandic horses exported to mainland Europe as adults (1st generation) have a >/=50% incidence of developing IBH. In contrast, their progeny (2nd generation) has a <10% incidence of IBH. Here we show that peripheral blood mononuclear cells (PBMC) from Icelandic horses born in mainland Europe and belonging either to the IBH or healthy subgroup produce less interleukin (IL)-4 after polyclonal or allergen-specific stimulation when compared with counterparts from horses born in Iceland. We examined a role of IL-10 and transforming growth factor (TGF)-beta1 in down-regulation of IL-4 in healthy 2nd generation Icelandic horses. Supernatants of PBMC from 2nd generation healthy horses down-regulated the proportion of IL-4-producing cells and IL-4 production in stimulated cultures of PBMC from 1st generation IBH. This inhibition was mimicked by a combination of IL-10 and TGF-beta1 but not by the single cytokines. Cultures of stimulated PBMC of healthy 2nd generation horses produced a low level of IL-4, but IL-4 production was increased by anti-equine IL-10 and anti-human TGF-beta1. This shows for the first time that in horses, IL-10 and TGF-beta1 combined regulate IL-4 production in vitro. It is suggested that in this naturally occurring IgE-mediated allergy, IL-10 and TGF-beta1 have a role in the down-regulation of IL-4-induced allergen-specific Th2 cells, thereby reducing the incidence of IBH.
Resumo:
BACKGROUND Conventional factors do not fully explain the distribution of cardiovascular outcomes. Biomarkers are known to participate in well-established pathways associated with cardiovascular disease, and may therefore provide further information over and above conventional risk factors. This study sought to determine whether individual and/or combined assessment of 9 biomarkers improved discrimination, calibration and reclassification of cardiovascular mortality. METHODS 3267 patients (2283 men), aged 18-95 years, at intermediate-to-high-risk of cardiovascular disease were followed in this prospective cohort study. Conventional risk factors and biomarkers were included based on forward and backward Cox proportional stepwise selection models. RESULTS During 10-years of follow-up, 546 fatal cardiovascular events occurred. Four biomarkers (interleukin-6, neutrophils, von Willebrand factor, and 25-hydroxyvitamin D) were retained during stepwise selection procedures for subsequent analyses. Simultaneous inclusion of these biomarkers significantly improved discrimination as measured by the C-index (0.78, P = 0.0001), and integrated discrimination improvement (0.0219, P<0.0001). Collectively, these biomarkers improved net reclassification for cardiovascular death by 10.6% (P<0.0001) when added to the conventional risk model. CONCLUSIONS In terms of adverse cardiovascular prognosis, a biomarker panel consisting of interleukin-6, neutrophils, von Willebrand factor, and 25-hydroxyvitamin D offered significant incremental value beyond that conveyed by simple conventional risk factors.
Resumo:
OBJECTIVE To analyze the precision of fit of implant-supported screw-retained computer-aided-designed and computer-aided-manufactured (CAD/CAM) zirconium dioxide (ZrO) frameworks. MATERIALS AND METHODS Computer-aided-designed and computer-aided-manufactured ZrO frameworks (NobelProcera) for a screw-retained 10-unit implant-supported reconstruction on six implants (FDI positions 15, 13, 11, 21, 23, 25) were fabricated using a laser (ZrO-L, N = 6) and a mechanical scanner (ZrO-M, N = 5) for digitizing the implant platform and the cuspid-supporting framework resin pattern. Laser-scanned CAD/CAM titanium (TIT-L, N = 6) and cast CoCrW-alloy frameworks (Cast, N = 5) fabricated on the same model and designed similar to the ZrO frameworks were the control. The one-screw test (implant 25 screw-retained) was applied to assess the vertical microgap between implant and framework platform with a scanning electron microscope. The mean microgap was calculated from approximal and buccal values. Statistical comparison was performed with non-parametric tests. RESULTS No statistically significant pairwise difference was observed between the relative effects of vertical microgap between ZrO-L (median 14 μm; 95% CI 10-26 μm), ZrO-M (18 μm; 12-27 μm) and TIT-L (15 μm; 6-18 μm), whereas the values of Cast (236 μm; 181-301 μm) were significantly higher (P < 0.001) than the three CAD/CAM groups. A monotonous trend of increasing values from implant 23 to 15 was observed in all groups (ZrO-L, ZrO-M and Cast P < 0.001, TIT-L P = 0.044). CONCLUSIONS Optical and tactile scanners with CAD/CAM technology allow for the fabrication of highly accurate long-span screw-retained ZrO implant-reconstructions. Titanium frameworks showed the most consistent precision. Fit of the cast alloy frameworks was clinically inacceptable.
Resumo:
We present a derivation and, based on it, an extension of a model originally proposed by V.G. Niziev to describe continuous wave laser cutting of metals. Starting from a local energy balance and by incorporating heat removal through heat conduction to the bulk material, we find a differential equation for the cutting profile. This equation is solved numerically and yields, besides the cutting profiles, the maximum cutting speed, the absorptivity profiles, and other relevant quantities. Our main goal is to demonstrate the model’s capability to explain some of the experimentally observed differences between laser cutting at around 1 and 10 μm wavelengths. To compare our numerical results to experimental observations, we perform simulations for exactly the same material and laser beam parameters as those used in a recent comparative experimental study. Generally, we find good agreement between theoretical and experimental results and show that the main differences between laser cutting with 1- and 10-μm beams arise from the different absorptivity profiles and absorbed intensities. Especially the latter suggests that the energy transfer, and thus the laser cutting process, is more efficient in the case of laser cutting with 1-μm beams.
Resumo:
AIMS High-density lipoprotein (HDL) cholesterol is a strong predictor of cardiovascular mortality. This work aimed to investigate whether the presence of coronary artery disease (CAD) impacts on its predictive value. METHODS AND RESULTS We studied 3141 participants (2191 males, 950 females) of the LUdwigshafen RIsk and Cardiovascular health (LURIC) study. They had a mean ± standard deviation age of 62.6 ± 10.6 years, body mass index of 27.5 ± 4.1 kg/m², and HDL cholesterol of 38.9 ± 10.8 mg/dL. The cohort consisted of 699 people without CAD, 1515 patients with stable CAD, and 927 patients with unstable CAD. The participants were prospectively followed for cardiovascular mortality over a median (inter-quartile range) period of 9.9 (8.7-10.7) years. A total of 590 participants died from cardiovascular diseases. High-density lipoprotein cholesterol by tertiles was inversely related to cardiovascular mortality in the entire cohort (P = 0.009). There was significant interaction between HDL cholesterol and CAD in predicting the outcome (P = 0.007). In stratified analyses, HDL cholesterol was strongly associated with cardiovascular mortality in people without CAD [3rd vs. 1st tertile: HR (95% CI) = 0.37 (0.18-0.74), P = 0.005], but not in patients with stable [3rd vs. 1st tertile: HR (95% CI) = 0.81 (0.61-1.09), P = 0.159] and unstable [3rd vs. 1st tertile: HR (95% CI) = 0.91 (0.59-1.41), P = 0.675] CAD. These results were replicated by analyses in 3413 participants of the AtheroGene cohort and 5738 participants of the ESTHER cohort, and by a meta-analysis comprising all three cohorts. CONCLUSION The inverse relationship of HDL cholesterol with cardiovascular mortality is weakened in patients with CAD. The usefulness of considering HDL cholesterol for cardiovascular risk stratification seems limited in such patients.