50 resultados para Rate of change


Relevância:

100.00% 100.00%

Publicador:

Resumo:

If change over time is compared in several groups, it is important to take into account baseline values so that the comparison is carried out under the same preconditions. As the observed baseline measurements are distorted by measurement error, it may not be sufficient to include them as covariate. By fitting a longitudinal mixed-effects model to all data including the baseline observations and subsequently calculating the expected change conditional on the underlying baseline value, a solution to this problem has been provided recently so that groups with the same baseline characteristics can be compared. In this article, we present an extended approach where a broader set of models can be used. Specifically, it is possible to include any desired set of interactions between the time variable and the other covariates, and also, time-dependent covariates can be included. Additionally, we extend the method to adjust for baseline measurement error of other time-varying covariates. We apply the methodology to data from the Swiss HIV Cohort Study to address the question if a joint infection with HIV-1 and hepatitis C virus leads to a slower increase of CD4 lymphocyte counts over time after the start of antiretroviral therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS In colorectal cancer (CRC), tumour buds represent an aggressive cell type at the invasive front with apparently low proliferation. The aim of this study was to determine proliferation and apoptotic rates of buds in comparison to tumour centre, front and mucosa. METHODS AND RESULTS Whole tissue sections from 188 CRC patients underwent immunohistochemistry for Ki67. Ten high-power fields (HPFs) were evaluated in mucosa, tumour centre, tumour front and tumour buds (total = 40 HPFs/case). Caspase-3 and M30 immunohistochemistry were performed on a multipunch tissue microarray from the same cohort. Ki67, caspase-3 and M30 immunoreactivity were correlated with outcome. The average percentage of cells showing Ki67 positivity was 5.2% in mucosa, and was not significantly different between the centre and front of the tumour (38.2% and 34.9%; P < 0.0001); 0.3% of buds showed Ki67 positivity (P < 0.0001). Caspase-3 expression was similar in mucosa, tumour centre and tumour front, but lower in tumour buds (<0.1%; P < 0.0001). M30 staining in buds was decreased (0.01%; P < 0.0001) in comparison to other areas. Ki67 positivity in buds was detrimental to survival in univariate (P = 0.0352) and multivariate (P = 0.0355) analysis. Caspase-3-positive tumours showed better outcome than negative tumours (P = 0.0262); but tumours with caspase-3-positive buds showed a worse outcome than those with caspase-3-negative buds (P = 0.0235). CONCLUSIONS Ki67, caspase-3 and M30 staining is absent in most tumour buds, suggesting decreased proliferation and apoptosis. However, the fact that Ki67 and caspase-3 immunoreactivity was associated with unfavourable prognosis points to a heterogeneous population of tumour buds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES Tenofovir is associated with reduced renal function. It is not clear whether patients can be expected to fully recover their renal function if tenofovir is discontinued. METHODS We calculated the estimated glomerular filtration rate (eGFR) for patients in the Swiss HIV Cohort Study remaining on tenofovir for at least 1 year after starting a first antiretroviral therapy regimen with tenofovir and either efavirenz or the ritonavir-boosted protease inhibitor lopinavir, atazanavir or darunavir. We estimated the difference in eGFR slope between those who discontinued tenofovir after 1 year and those who remained on tenofovir. RESULTS A total of 1049 patients on tenofovir for at least 1 year were then followed for a median of 26 months, during which time 259 patients (25%) discontinued tenofovir. After 1 year on tenofovir, the difference in eGFR between those starting with efavirenz and those starting with lopinavir, atazanavir and darunavir was - 0.7 [95% confidence interval (CI) -2.3 to 0.8], -1.4 (95% CI -3.2 to 0.3) and 0.0 (95% CI -1.7 to 1.7) mL/min/1.73 m(2) , respectively. The estimated linear rate of decline in eGFR on tenofovir was -1.1 (95% CI -1.5 to -0.8) mL/min/1.73 m(2) per year and its recovery after discontinuing tenofovir was 2.1 (95% CI 1.3 to 2.9) mL/min/1.73 m(2) per year. Patients starting tenofovir with either lopinavir or atazanavir appeared to have the same rates of decline and recovery as those starting tenofovir with efavirenz. CONCLUSIONS If patients discontinue tenofovir, clinicians can expect renal function to recover more rapidly than it declined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Greenland NEEM (North Greenland Eemian Ice Drilling) operation in 2010 provided the first opportunity to combine trace-gas measurements by laser spectroscopic instruments and continuous-flow analysis along a freshly drilled ice core in a field-based setting. We present the resulting atmospheric methane (CH4) record covering the time period from 107.7 to 9.5 ka b2k (thousand years before 2000 AD). Companion discrete CH4 measurements are required to transfer the laser spectroscopic data from a relative to an absolute scale. However, even on a relative scale, the high-resolution CH4 data set significantly improves our knowledge of past atmospheric methane concentration changes. New significant sub-millennial-scale features appear during interstadials and stadials, generally associated with similar changes in water isotopic ratios of the ice, a proxy for local temperature. In addition to the midpoint of Dansgaard–Oeschger (D/O) CH4 transitions usually used for cross-dating, sharp definition of the start and end of these events brings precise depth markers (with ±20 cm uncertainty) for further cross-dating with other palaeo- or ice core records, e.g. speleothems. The method also provides an estimate of CH4 rates of change. The onsets of D/O events in the methane signal show a more rapid rate of change than their endings. The rate of CH4 increase associated with the onsets of D/O events progressively declines from 1.7 to 0.6 ppbv yr−1 in the course of marine isotope stage 3. The largest observed rate of increase takes place at the onset of D/O event #21 and reaches 2.5 ppbv yr−1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND The risk of Kaposi sarcoma (KS) among HIV-infected persons on antiretroviral therapy (ART) is not well defined in resource-limited settings. We studied KS incidence rates and associated risk factors in children and adults on ART in Southern Africa. METHODS We included patient data of 6 ART programs in Botswana, South Africa, Zambia, and Zimbabwe. We estimated KS incidence rates in patients on ART measuring time from 30 days after ART initiation to KS diagnosis, last follow-up visit, or death. We assessed risk factors (age, sex, calendar year, WHO stage, tuberculosis, and CD4 counts) using Cox models. FINDINGS We analyzed data from 173,245 patients (61% female, 8% children aged <16 years) who started ART between 2004 and 2010. Five hundred and sixty-four incident cases were diagnosed during 343,927 person-years (pys). The overall KS incidence rate was 164/100,000 pys [95% confidence interval (CI): 151 to 178]. The incidence rate was highest 30-90 days after ART initiation (413/100,000 pys; 95% CI: 342 to 497) and declined thereafter [86/100,000 pys (95% CI: 71 to 105), >2 years after ART initiation]. Male sex [adjusted hazard ratio (HR): 1.34; 95% CI: 1.12 to 1.61], low current CD4 counts (≥500 versus <50 cells/μL, adjusted HR: 0.36; 95% CI: 0.23 to 0.55), and age (5-9 years versus 30-39 years, adjusted HR: 0.20; 95% CI: 0.05 to 0.79) were relevant risk factors for developing KS. INTERPRETATION Despite ART, KS risk in HIV-infected persons in Southern Africa remains high. Early HIV testing and maintaining high CD4 counts is needed to further reduce KS-related morbidity and mortality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to examine the success rate of paramedian palatal Orthosystem first- and second-generation implants used for anchorage in orthodontic treatment in patients treated by one experienced orthodontist. The records of 143 patients (90 female, 53 male, median age: 15.7 years, range: 10.2-50.9) receiving 145 palatal implants of the first or second generation (Orthosystem, Straumann AG, Basel, Switzerland) were examined. All the palatal implants were placed in a paramedian palatal location by three experienced surgeons. Stable implants were orthodontically loaded after a healing period of 3 months. Out of the 145 inserted paramedian palatal implants only seven implants (4.8%) were not considered stable after insertion. All the successfully osseointegrated implants remained stable during orthodontic treatment. Paramedian palatal implants are highly reliable and effective devices to obtain skeletal anchorage for orthodontic treatment. This study has shown that the paramedian location is a good alternative to the median location.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Bolt-kit systems are increasingly used as an alternative to conventional external cerebrospinal fluid (CSF) drainage systems. Since 2009 we regularly utilize bolt-kit external ventricular drainage (EVD) systems with silver-bearing catheters inserted manually with a hand drill and skull screws for emergency ventriculostomy. For non-emergency situations, we use conventional ventriculostomy with subcutaneous tunneled silver-bearing catheters, performed in the operating room with a pneumatic drill. This retrospective analysis compared the two techniques in terms of infection rates. METHODS 152 patients (aged 17-85 years, mean=55.4 years) were included in the final analysis; 95 received bolt-kit silver-bearing catheters and 57 received conventionally implanted silver-bearing catheters. The primary endpoint combined infection parameters: occurrence of positive CSF culture, colonization of catheter tips, or elevated CSF white blood cell counts (>4/μl). Secondary outcome parameters were presence of microorganisms in CSF or on catheter tips. Incidence of increased CSF cell counts and number of patients with catheter malposition were also compared. RESULTS The primary outcome, defined as analysis of combined infection parameters (occurrence of either positive CSF culture, colonization of the catheter tips or raised CSF white blood cell counts >4/μl)was not significantly different between the groups (58.9% bolt-kit group vs. 63.2% conventionally implanted group, p=0.61, chi-square-test). The bolt-kit group was non-inferior and not superior to the conventional group (relative risk reduction of 6.7%; 90% confidence interval: -19.9% to 25.6%). Secondary outcomes showed no statistically significant difference in the incidence of microorganisms in CSF (2.1% bolt-kit vs. 5.3% conventionally implanted; p=0.30; chi-square-test). CONCLUSIONS This analysis indicates that silver-bearing EVD catheters implanted with a bolt-kit system outside the operating room do not significantly elevate the risk of CSF infection as compared to conventional implant methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Anti-TNFα agents are commonly used for ulcerative colitis (UC) therapy in the event of non-response to conventional strategies or as colon-salvaging therapy. The objectives were to assess the appropriateness of biological therapies for UC patients and to study treatment discontinuation over time, according to appropriateness of treatment, as a measure of outcome. METHODS We selected adult ulcerative colitis patients from the Swiss IBD cohort who had been treated with anti-TNFα agents. Appropriateness of the first-line anti-TNFα treatment was assessed using detailed criteria developed during the European Panel on the Appropriateness of Therapy for UC. Treatment discontinuation as an outcome was assessed for categories of appropriateness. RESULTS Appropriateness of the first-line biological treatment was determined in 186 UC patients. For 64% of them, this treatment was considered appropriate. During follow-up, 37% of all patients discontinued biological treatment, 17% specifically because of failure. Time-to-failure of treatment was significantly different among patients on an appropriate biological treatment compared to those for whom the treatment was considered not appropriate (p=0.0007). Discontinuation rate after 2years was 26% compared to 54% between those two groups. Patients on inappropriate biological treatment were more likely to have severe disease, concomitant steroids and/or immunomodulators. They were also consistently more likely to suffer a failure of efficacy and to stop therapy during follow-up. CONCLUSION Appropriateness of first-line anti-TNFα therapy results in a greater likelihood of continuing with the therapy. In situations where biological treatment is uncertain or inappropriate, physicians should consider other options instead of prescribing anti-TNFα agents.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE Short implants are increasingly used, but there is doubt about their performance being similar to that of regular implants. The aim of this study was to compare the mechanical stability of short implants vs. regular implants placed in the edentulous posterior mandible. MATERIAL AND METHODS Twenty-three patients received a total of 48 short implants (5 × 5.5 mm and 5 × 7 mm) and 42 regular implants (4 × 10 mm and 4 × 11.5 mm) in the posterior mandible. Patients who received short implants had <10 mm of bone height measured from the bone crest to the outer wall of the mandibular canal. Resonance frequency analysis (RFA) was performed at time intervals T0 (immediately after implant placement), T1 (after 15 days), T2 (after 30 days), T3 (after 60 days), and T4 (after 90 days). RESULTS The survival rate after 90 days was 87.5% for the short implants and 100% for regular implants (P < 0.05). There was no significant difference between the implants in time intervals T1, T2, T3, and T4. In T0, the RFA values of 5 × 5.5 implants were higher than values of 5 × 7 and 4 × 11.5 implants (P < 0.05). A total of six short implants that were placed in four patients were lost (three of 5 × 5.5 mm and three of 5 × 7 mm). Three lost implants started with high ISQ values, which progressively decreased. The other three lost implants started with a slightly lower ISQ value, which rose and then began to fall. CONCLUSIONS Survival rate of short implants after 90 days was lower than that of regular implants. However, short implants may be considered a reasonable alternative for rehabilitation of severely resorbed mandibles with reduced height, to avoid performing bone reconstruction before implant placement. Patients need to be aware of the reduced survival rate compared with regular implants before implant placement to avoid disappointments.