104 resultados para Rapid diagnostic test
Resumo:
Lumbar spinal stenosis is a frequent indication for spinal surgery. The predictive quality of treadmill testing and MRI for diagnostic verification is not yet clearly defined. Aim of the current study was to assess correlations between treadmill testing and MRI findings in the lumbar spine. Twenty-five patients with lumbar spinal stenosis were prospectively examined. Treadmill tests were performed and the area of the dural sac and neuroforamina was examined with MRI for the narrowest spinal segment. VAS and ODI were used for clinical assessment. The median age of the patients was 67 years. In the narrowest spinal segment the median area of the dural sac was 91 mm(2). The median ODI was 66 per cent. The median walking distance in the treadmill test was 70 m. The distance reached in the treadmill test correlated with the area of the dural sac (Spearman's rho = 0.53) and ODI (rho = -0.51), but not with the area of the neuroforamina and VAS. The distance reached in the treadmill test predicts the grade of stenosis in MRI but has a limited diagnostic importance for the level of clinical symptoms in lumbar spinal stenosis.
Resumo:
There is no accepted way of measuring prothrombin time without time loss for patients undergoing major surgery who are at risk of intraoperative dilution and consumption coagulopathy due to bleeding and volume replacement with crystalloids or colloids. Decisions to transfuse fresh frozen plasma and procoagulatory drugs have to rely on clinical judgment in these situations. Point-of-care devices are considerably faster than the standard laboratory methods. In this study we assessed the accuracy of a Point-of-care (PoC) device measuring prothrombin time compared to the standard laboratory method. Patients undergoing major surgery and intensive care unit patients were included. PoC prothrombin time was measured by CoaguChek XS Plus (Roche Diagnostics, Switzerland). PoC and reference tests were performed independently and interpreted under blinded conditions. Using a cut-off prothrombin time of 50%, we calculated diagnostic accuracy measures, plotted a receiver operating characteristic (ROC) curve and tested for equivalence between the two methods. PoC sensitivity and specificity were 95% (95% CI 77%, 100%) and 95% (95% CI 91%, 98%) respectively. The negative likelihood ratio was 0.05 (95% CI 0.01, 0.32). The positive likelihood ratio was 19.57 (95% CI 10.62, 36.06). The area under the ROC curve was 0.988. Equivalence between the two methods was confirmed. CoaguChek XS Plus is a rapid and highly accurate test compared with the reference test. These findings suggest that PoC testing will be useful for monitoring intraoperative prothrombin time when coagulopathy is suspected. It could lead to a more rational use of expensive and limited blood bank resources.
Resumo:
Recently, screening tests for monitoring the prevalence of transmissible spongiform encephalopathies specifically in sheep and goats became available. Although most countries require comprehensive test validation prior to approval, little is known about their performance under normal operating conditions. Switzerland was one of the first countries to implement 2 of these tests, an enzyme-linked immunosorbent assay (ELISA) and a Western blot, in a 1-year active surveillance program. Slaughtered animals (n = 32,777) were analyzed in either of the 2 tests with immunohistochemistry for confirmation of initial reactive results, and fallen stock samples (n = 3,193) were subjected to both screening tests and immunohistochemistry in parallel. Initial reactive and false-positive rates were recorded over time. Both tests revealed an excellent diagnostic specificity (>99.5%). However, initial reactive rates were elevated at the beginning of the program but dropped to levels below 1% with routine and enhanced staff training. Only those in the ELISA increased again in the second half of the program and correlated with the degree of tissue autolysis in the fallen stock samples. It is noteworthy that the Western blot missed 1 of the 3 atypical scrapie cases in the fallen stock, indicating potential differences in the diagnostic sensitivities between the 2 screening tests. However, an estimation of the diagnostic sensitivity for both tests on field samples remained difficult due to the low disease prevalence. Taken together, these results highlight the importance of staff training, sample quality, and interlaboratory comparison trials when such screening tests are implemented in the field.
Resumo:
Bovine spongiform encephalopathy (BSE) rapid tests and routine BSE-testing laboratories underlie strict regulations for approval. Due to the lack of BSE-positive control samples, however, full assay validation at the level of individual test runs and continuous monitoring of test performance on-site is difficult. Most rapid tests use synthetic prion protein peptides, but it is not known to which extend they reflect the assay performance on field samples, and whether they are sufficient to indicate on-site assay quality problems. To address this question we compared the test scores of the provided kit peptide controls to those of standardized weak BSE-positive tissue samples in individual test runs as well as continuously over time by quality control charts in two widely used BSE rapid tests. Our results reveal only a weak correlation between the weak positive tissue control and the peptide control scores. We identified kit-lot related shifts in the assay performances that were not reflected by the peptide control scores. Vice versa, not all shifts indicated by the peptide control scores indeed reflected a shift in the assay performance. In conclusion these data highlight that the use of the kit peptide controls for continuous quality control purposes may result in unjustified rejection or acceptance of test runs. However, standardized weak positive tissue controls in combination with Shewhart-CUSUM control charts appear to be reliable in continuously monitoring assay performance on-site to identify undesired deviations.
Resumo:
Human rabies is rare in Western Europe. It is not easily recognized in the absence of a history of exposure. We describe the clinical course, diagnosis and follow-up of an imported human rabies case in Switzerland. The patient, a U.S. citizen, presented at an outpatient clinic in Iraq with pain in his right shoulder on July 5, 2012. On July 8 he was transferred to a hospital in the United Arab Emirates, where he exhibited progressive encephalitis with coma. On July 29, he was transferred to a hospital in Switzerland, where he died on July 31, 2012. The autopsy showed severe encephalitis. Rabies was diagnosed by the rapid fluorescent focus inhibition test (RFFIT) and confirmed by fluorescence antibody testing (FAT) in brain smears and immunohistochemistry on paraffin-embedded brain sections. The viral strain was characterized by RT-PCR followed by sequencing and phylogenetic analysis as an American bat rabies strain associated with Tadarida brasiliensis. Close contacts and exposed health care workers received postexposure prophylaxis (PEP).
Resumo:
A rapid and simple DNA labeling system has been developed for disposable microarrays and has been validated for the detection of 117 antibiotic resistance genes abundant in Gram-positive bacteria. The DNA was fragmented and amplified using phi-29 polymerase and random primers with linkers. Labeling and further amplification were then performed by classic PCR amplification using biotinylated primers specific for the linkers. The microarray developed by Perreten et al. (Perreten, V., Vorlet-Fawer, L., Slickers, P., Ehricht, R., Kuhnert, P., Frey, J., 2005. Microarray-based detection of 90 antibiotic resistance genes of gram-positive bacteria. J.Clin.Microbiol. 43, 2291-2302.) was improved by additional oligonucleotides. A total of 244 oligonucleotides (26 to 37 nucleotide length and with similar melting temperatures) were spotted on the microarray, including genes conferring resistance to clinically important antibiotic classes like β-lactams, macrolides, aminoglycosides, glycopeptides and tetracyclines. Each antibiotic resistance gene is represented by at least 2 oligonucleotides designed from consensus sequences of gene families. The specificity of the oligonucleotides and the quality of the amplification and labeling were verified by analysis of a collection of 65 strains belonging to 24 species. Association between genotype and phenotype was verified for 6 antibiotics using 77 Staphylococcus strains belonging to different species and revealed 95% test specificity and a 93% predictive value of a positive test. The DNA labeling and amplification is independent of the species and of the target genes and could be used for different types of microarrays. This system has also the advantage to detect several genes within one bacterium at once, like in Staphylococcus aureus strain BM3318, in which up to 15 genes were detected. This new microarray-based detection system offers a large potential for applications in clinical diagnostic, basic research, food safety and surveillance programs for antimicrobial resistance.
Resumo:
The characteristic features of Whipple's disease include abdominal pain, diarrhoea, wasting, and arthralgias, with the causative agent, Tropheryma whipplei, being detected mainly in intestinal biopsies. PCR technology has led to the identification of T. whipplei in specimens from various other locations, including the central nervous system and the heart. T. whipplei is now recognized as one of the causes of culture-negative endocarditis, and endocarditis can be the only manifestation of the infection with T. whipplei. Although it is considered a rare disease, the true incidence of endocarditis due to T. whipplei is not clearly established. With the increasing use of molecular methods, it is likely that T. whipplei will be more frequently identified. Questions also remain about the genetic variability of T. whipplei strains, optimal diagnostic procedures and therapeutic options. In the present study, we provide clinical data on four new patients with documented endocarditis due to T. whipplei in the context of the available published literature. There was no clinical involvement of the gastrointestinal tract. Genetic analysis of the T. whipplei strains with DNA isolated from the excised heart valves revealed little to no genetic variability. In a selected case, we describe acridine orange staining for early detection of the disease, prompting early adaptation of the antibiotic therapy. We provide long-term follow-up data on the patients. In our hands, an initial 2-week course of intravenous antibiotics followed by cotrimoxazole for at least 1 year was a suitable treatment option for T. whipplei endocarditis.
Resumo:
The original and modified Wells score are widely used prediction rules for pre-test probability assessment of deep vein thrombosis (DVT). The objective of this study was to compare the predictive performance of both Wells scores in unselected patients with clinical suspicion of DVT.
Resumo:
The best available test for the diagnosis of upper extremity deep venous thrombosis (UEDVT) is contrast venography. The aim of this systematic review was to assess whether the diagnostic accuracy of other tests for clinically suspected UEDVT is high enough to justify their use in clinical practise and to evaluate if any test can replace venography.
Resumo:
Dopamine has long held a prominent role in the interpretation of schizophrenia and other psychoses. Clinical studies on confabulation and disorientation, disorders marked by a confusion of reality in thinking, indicated that the ability to keep thinking in phase with reality depends on a process suppressing the interference of upcoming memories that do not refer to ongoing reality. A host of animal studies and a recent clinical study suggested that this suppression might correspond to the phasic inhibition of dopaminergic neurons in response to the absence of expected outcomes. In this study, we tested healthy subjects with a difficult version of a memory paradigm on which confabulating patients had failed. Subjects participated in three test sessions, in which they received in double-blind, randomized fashion L-dopa, risperidone, or placebo. We found that l-dopa, in comparison with risperidone, impaired performance in a highly specific way, which corresponded to the pattern of patients with reality confusion. Specifically, they had an increase of false positive responses, while overall memory performance and reaction times were unaffected. We conclude that dopaminergic transmission influences the ability to rapidly adapt thinking to ongoing reality.
Resumo:
Background Urinary tract infections (UTI) are frequent in outpatients. Fast pathogen identification is mandatory for shortening the time of discomfort and preventing serious complications. Urine culture needs up to 48 hours until pathogen identification. Consequently, the initial antibiotic regimen is empirical. Aim To evaluate the feasibility of qualitative urine pathogen identification by a commercially available real-time PCR blood pathogen test (SeptiFast®) and to compare the results with dipslide and microbiological culture. Design of study Pilot study with prospectively collected urine samples. Setting University hospital. Methods 82 prospectively collected urine samples from 81 patients with suspected UTI were included. Dipslide urine culture was followed by microbiological pathogen identification in dipslide positive samples. In parallel, qualitative DNA based pathogen identification (SeptiFast®) was performed in all samples. Results 61 samples were SeptiFast® positive, whereas 67 samples were dipslide culture positive. The inter-methodological concordance of positive and negative findings in the gram+, gram- and fungi sector was 371/410 (90%), 477/492 (97%) and 238/246 (97%), respectively. Sensitivity and specificity of the SeptiFast® test for the detection of an infection was 0.82 and 0.60, respectively. SeptiFast® pathogen identifications were available at least 43 hours prior to culture results. Conclusion The SeptiFast® platform identified bacterial DNA in urine specimens considerably faster compared to conventional culture. For UTI diagnosis sensitivity and specificity is limited by its present qualitative setup which does not allow pathogen quantification. Future quantitative assays may hold promise for PCR based UTI pathogen identification as a supplementation of conventional culture methods.
Resumo:
In 2003, the QUADAS tool for systematic reviews of diagnostic accuracy studies was developed. Experience, anecdotal reports, and feedback suggested areas for improvement; therefore, QUADAS-2 was developed. This tool comprises 4 domains: patient selection, index test, reference standard, and flow and timing. Each domain is assessed in terms of risk of bias, and the first 3 domains are also assessed in terms of concerns regarding applicability. Signalling questions are included to help judge risk of bias. The QUADAS-2 tool is applied in 4 phases: summarize the review question, tailor the tool and produce review-specific guidance, construct a flow diagram for the primary study, and judge bias and applicability. This tool will allow for more transparent rating of bias and applicability of primary diagnostic accuracy studies.
Resumo:
Background Injuries from skiing and snowboarding became a major challenge for emergency care providers in Switzerland. In the alpine setting, early assessment of injury and health status is essential for the initiation of adequate means of care and transport. Nevertheless, validated standardized protocols for on-slope triage are missing. This article can assist in understanding the characteristics of injured winter sportsmen and exigencies for future on-slope triage protocols. Methods Six-year review of trauma cases in a tertiary trauma centre. Consecutive inclusion of all injured skiers and snowboarders aged >15 (total sample) years with predefined, severe injury to the head, spine, chest, pelvis or abdomen (study sample) presenting at or being transferred to the study hospital. Descriptive analysis of age, gender and injury pattern. Results Amongst 729 subjects (total sample) injured from skiing or snowboarding, 401 (55%, 54% of skiers and 58% of snowboarders) suffered from isolated limb injury. Amongst the remaining 328 subjects (study sample), the majority (78%) presented with monotrauma. In the study sample, injury to the head (52%) and spine (43%) was more frequent than injury to the chest (21%), pelvis (8%), and abdomen (5%). The three most frequent injury combinations were head/spine (10% of study sample), head/thorax (9%), and spine/thorax (6%). Fisher's exact test demonstrated an association for injury combinations of head/thorax (p < 0.001), head/abdomen (p = 0.019), and thorax/abdomen (p < 0.001). Conclusion The data presented and the findings from previous investigations indicate the need for development of dedicated on-slope triage protocols. Future research must address the validity and practicality of diagnostic on-slope tests for rapid decision making by both professional and lay first responders. Thus, large-scale and detailed injury surveillance is the future research priority.
Resumo:
Kyrgyzstan reported 77.5 new human brucellosis cases per 100,000 people in 2007, which is one of the highest incidences worldwide. In Kyrgyzstan, the currently used diagnostic tests in humans and animals are the Rose Bengal Test and the Huddleson test. A national representative cross-sectional study using cluster sampling proportional to size in humans, cattle, sheep, and goats was undertaken to assess the apparent seroprevalence in humans and animals. A total of 4,936 livestock sera and 1,774 human sera were tested in Naryn, Chuy, and Osh Oblasts. The overall apparent seroprevalences of brucellosis were 8.8% in humans (95% CI 4.5-16.5), 2.8% (95% CI 1.6-4.9%) in cattle, 3.3% (95% CI 1.5-6.9%) in sheep, and 2.5% (95% CI 1.4-4.5%) in goats. Naryn Oblast had the highest seroprevalences in humans and sheep. More men than women were seropositive (OR = 1.96; P < 0.001). Human seroprevalence was significantly associated with small ruminant seroprevalence but not with cattle seroprevalence. Annual incidence of human brucellosis exposure, measured by serological tests, was more than ten times higher than the annual incidence of reported clinical brucellosis cases. This indicates an under-reporting of human brucellosis cases, even if only a fraction of seropositive people have clinical symptoms. In conclusion, this study confirms the high seroprevalence of brucellosis in Kyrgyzstan and warrants rapid effective intervention, among others, by mass vaccination of sheep and goats but also of cattle.