229 resultados para PERI-IMPLANT BONE


Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: To assess dimensional ridge alterations following immediate implant placement in molar extraction sites. MATERIAL AND METHODS: Twelve subjects received 12 immediate transmucosal implants in molar extraction sites. Peri-implant defects were treated according to the principles of Guided Bone Regeneration by means of a deproteinized bone substitute and a bioresorbable collagen membrane. Changes in vertical (IS-BD, CREST-BD) and horizontal distances (EC-I, IC-I) of alveolar bony walls to the bottom of the defects (BD) and to the implant surfaces (I) were compared between implant placement and surgical re-entry at 6 months. RESULTS: The implant survival rate at 6 months was 100%. Statistically significant differences (P<0.01) were observed in the mean changes in vertical distances IS-BD and CREST-BD between baseline and re-entry. At re-entry, all peri-implant marginal defects assessed from the internal socket wall to the implant surface (IC-I) were healed. The residual combined thickness of the buccal wall with the newly formed peri-implant bone at sites with an initial thickness of 1 mm was statistically significantly smaller (P<0.05) compared with that of sites with an initial buccal thickness of 2 mm (2.50 +/- 0.76 vs. 4+/-0 mm). CONCLUSIONS: The marginal defects around immediate implants placed in molar extraction sites were completely filled after 6 months of healing through de novo bone formation. Bone resorption was observed from the external aspects of the buccal and oral socket walls. Dimensional changes of the external socket walls were mostly pronounced at the buccal aspects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this prospective case series study, 20 patients with an implant-borne single crown following early implant placement with simultaneous contour augmentation were followed for 6 years. Clinical, radiologic, and esthetic parameters were assessed. In addition, cone beam computed tomography (CBCT) was used at 6 years to examine the facial bone wall. During the study period, all 20 implants were successfully integrated, and the clinical parameters remained stable over time. Pleasing esthetic outcomes were noted, as assessed by the pink esthetic scores. None of the implants developed mucosal recession of 1 mm or more. The periapical radiographs yielded stable peri-implant bone levels, with a mean DIB of 0.44 mm at 6 years. The CBCT scans showed that all 20 implants had a detectable facial bone wall at 6 years, with a mean thickness of around 1.9 mm. In summary, this prospective case series study demonstrated stable peri-implant hard and soft tissues for all 20 implants, and pleasing esthetic outcomes overall. The follow-up of 6 years confirmed that the risk for mucosal recession is low with early implant placement. In addition, contour augmentation with guided bone regeneration (GBR) was able to establish and maintain a facial bone wall in all 20 patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Early implant placement with simultaneous contour augmentation is documented with short- and medium-term studies. The long-term stability of contour augmentation is uncertain. METHODS In this prospective, cross-sectional study, 41 patients with an implant-borne single crown were examined twice, in 2006 and 2010. Clinical, radiologic, and esthetic parameters were assessed at both examinations. In addition, a cone beam computed tomographic (CBCT) image was obtained during the second examination to assess the dimensions of the facial bone wall. RESULTS All 41 implants demonstrated ankylotic stability without signs of peri-implant infection at both examinations. The clinical parameters remained stable over time. Satisfactory esthetic outcomes were noted, as assessed by the pink and white esthetic score (PES/WES) indices. Overall, the PES scores were slightly higher than the WES scores. None of the implants developed mucosal recession over time, as confirmed by values of the distance between implant shoulder and mucosal margin and cast measurements. The periapical radiographs yielded stable peri-implant bone levels, with a mean distance between implant shoulder and first visible bone-implant contact value of 2.18 mm. The CBCT analysis demonstrated a mean thickness of the facial bone wall ≈2.2 mm. In two implants (4.9%) no facial bone wall was detectable radiographically. CONCLUSIONS This prospective cross-sectional study demonstrates stable peri-implant hard and soft tissues for all 41 implants examined and satisfactory esthetic outcomes overall. The follow-up of 5 to 9 years confirmed again that the risk for mucosal recession is low with early implant placement. In addition, contour augmentation with guided bone regeneration was able to establish and maintain a facial bone wall in 95% of patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE Crohn's disease is a chronic inflammatory process that has recently been associated with a higher risk of early implant failure. Herein we provide information on the impact of colitis on peri-implant bone formation using preclinical models of chemically induced colitis. METHODS Colitis was induced by intrarectal instillation of 2,4,6-trinitro-benzene-sulfonic-acid (TNBS). Colitis was also induced by feeding rats dextran-sodium-sulfate (DSS) in drinking water. One week after disease induction, titanium miniscrews were inserted into the tibia. Four weeks after implantation, peri-implant bone volume per tissue volume (BV/TV) and bone-to-implant contacts (BIC) were determined by histomorphometric analysis. RESULTS Cortical histomorphometric parameters were similar in the control (n = 10), DSS (n = 10) and TNBS (n = 8) groups. Cortical BV/TV was 92.2 ± 3.7%, 92.0 ± 3.0% and 92.6 ± 2.7%. Cortical BIC was 81.3 ± 8.8%, 83.2 ± 8.4% and 84.0 ± 7.0%, respectively. No significant differences were observed when comparing the medullary BV/TV and BIC (19.5 ± 6.4%, 16.2 ± 5.6% and 15.4 ± 9.0%) and (48.8 ± 12.9%, 49.2 ± 6.2 and 41.9 ± 11.7%), respectively. Successful induction of colitis was confirmed by loss of body weight and colon morphology. CONCLUSIONS The results suggest bone regeneration around implants is not impaired in chemically induced colitis models. Considering that Crohn's disease can affect any part of the gastrointestinal tract including the mouth, our model only partially reflects the clinical situation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE Extended grafting procedures in atrophic ridges are invasive and time-consuming and increase cost and patient morbidity. Therefore, ridge-splitting techniques have been suggested to enlarge alveolar crests. The aim of this cohort study was to report techniques and radiographic outcomes of implants placed simultaneously with a piezoelectric alveolar ridge-splitting technique (RST). Peri-implant bone-level changes (ΔIBL) of implants placed with (study group, SG) or without RST (control group, CG) were compared. MATERIALS AND METHODS Two cohorts (seven patients in each) were matched regarding implant type, position, and number; superstructure type; age; and gender and received 17 implants each. Crestal implant bone level (IBL) was measured at surgery (T0), loading (T1), and 1 year (T2) and 2 years after loading (T3). For all implants, ΔIBL values were determined from radiographs. Differences in ΔIBL between SG and CG were analyzed statistically (Mann-Whitney U test). Bone width was assessed intraoperatively, and vertical bone mapping was performed at T0, T1, and T3. RESULTS After a mean observation period of 27.4 months after surgery, the implant survival rate was 100%. Mean ΔIBL was -1.68 ± 0.90 mm for SG and -1.04 ± 0.78 mm for CG (P = .022). Increased ΔIBL in SG versus CG occurred mainly until T2. Between T2 and T3, ΔIBL was limited (-0.11 ± 1.20 mm for SG and -0.05 ± 0.16 mm for CG; P = .546). Median bone width increased intraoperatively by 4.7 mm. CONCLUSIONS Within the limitations of this study, it can be suggested that RST is a well-functioning one-stage alternative to extended grafting procedures if the ridge shows adequate height. ΔIBL values indicated that implants with RST may fulfill accepted implant success criteria. However, during healing and the first year of loading, increased IBL alterations must be anticipated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE The purpose of this study was to document the long-term outcome of Brånemark implants installed in augmented maxillary bone and to identify parameters that are associated with peri-implant bone level. MATERIAL AND METHODS Patients of a periodontal practice who had been referred to a maxillofacial surgeon for iliac crest bone grafting in the atrophic maxilla were retrospectively recruited. Five months following grafting, they received 7-8 turned Brånemark implants. Following submerged healing of another 5 months, implants were uncovered and restorative procedures for fixed rehabilitation were initiated 2-3 months thereafter. The primary outcome variable was bone level defined as the distance from the implant-abutment interface to the first visible bone-to-implant contact. Secondary outcome variables included plaque index, bleeding index, probing depth, and levels of 40 species in subgingival plaque samples as identified by means of checkerboard DNA-DNA hybridization. RESULTS Nine out of 16 patients (eight females, one male; mean age 59) with 71 implants agreed to come in for evaluation after on average 9 years (SD 4; range 3-13) of function. One implant was deemed mobile at the time of inspection. Clinical conditions were acceptable with 11% of the implants showing pockets ≥ 5 mm. Periodontopathogens were encountered frequently and in high numbers. Clinical parameters and bacterial levels were highly patient dependent. The mean bone level was 2.30 mm (SD 1.53; range 0.00-6.95), with 23% of the implants demonstrating advanced resorption (bone level > 3 mm). Regression analysis showed a significant association of the patient (p < .001) and plaque index (p = .007) with bone level. CONCLUSIONS The long-term outcome of Brånemark implants installed in iliac crest-augmented maxillary bone is acceptable; however, advanced peri-implant bone loss is rather common and indicative of graft resorption. This phenomenon is patient dependent and seems also associated with oral hygiene.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The concept of platform switching has been introduced to implant dentistry based on clinical observations of reduced peri-implant crestal bone loss. However, published data are controversial, and most studies are limited to 12 months. The aim of the present randomized clinical trial was to test the hypothesis that platform switching has a positive impact on crestal bone-level changes after 3 years. Two implants with a diameter of 4 mm were inserted crestally in the posterior mandible of 25 patients. The intraindividual allocation of platform switching (3.3-mm platform) and the standard implant (4-mm platform) was randomized. After 3 months of submerged healing, single-tooth crowns were cemented. Patients were followed up at short intervals for monitoring of healing and oral hygiene. Statistical analysis for the influence of time and platform type on bone levels employed the Brunner-Langer model. At 3 years, the mean radiographic peri-implant bone loss was 0.69 ± 0.43 mm (platform switching) and 0.74 ± 0.57 mm (standard platform). The mean intraindividual difference was 0.05 ± 0.58 mm (95% confidence interval: -0.19, 0.29). Crestal bone-level alteration depended on time (p < .001) but not on platform type (p = .363). The present randomized clinical trial could not confirm the hypothesis of a reduced peri-implant crestal bone loss, when implants had been restored according to the concept of platform switching.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES To histologically and immunologically assess experimental peri-implant mucositis at surface enhanced modified (mod) hydrophilic titanium implants. MATERIALS AND METHODS In a split-mouth design (n = 6 foxhounds), four different implants were inserted on each side of the maxilla: three titanium-zirconium alloy implants (TiZr) with either modSLA (sand-blasted, acid etched and chemically mod), modMA (machined, acid etched and chemically mod), or M (machined) surfaces in the transmucosal portion, and one titanium implant with a machined transmucosal portion (TiM). Experimental mucositis was induced at one randomly assigned side (NPC), whereas the contra-lateral maxillary side received mechanical plaque removal three times per week (PC). At 16 weeks, tissue biopsies were processed for histological (primary outcome: apical extension of the inflammatory cell infiltrate measured from the mucosal margin - PM-aICT) and immunohistochemical (CD68 antigen reactivity) analyses. Peri-implant sulcus fluid was analysed for interleukin (IL)-1β, IL-8, matrix metalloproteinase (MMP)-8 and myeloperoxidase (MPO). RESULTS Mean PM-aICT values varied between 1.86 (TiZrmodSLA) and 3.40 mm (TiM) in the UPC group, and between 0.88 (TiZrmodSLA) and 2.08 mm (TiZrM) in the PC group. Mean CD68, IL-1β, IL-8, MMP-8 and MPO values were equally distributed between mod- and control implants in both NPC and PC groups. CONCLUSIONS The progression of experimental mucositis was comparable at all implant surfaces investigated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose.This retrospective cohort study evaluated factors for peri-implant bone level changes (ΔIBL) associated with an implant type with inner-cone implant-abutment connection, rough neck surface, and platform switching (AT). Materials and Methods. All AT placed at the Department of Prosthodontics of the University of Bern between January 2004 and December 2005 were included in this study. All implants were examined by single radiographs using the parallel technique taken at surgery (T0) and obtained at least 6 months after surgery (T1). Possible influencing factors were analysed first using t-test (normal distribution) or the nonparametric Wilcoxon test (not normal distribution), and then a mixed model q variance analysis was performed. Results. 43 patients were treated with 109 implants. Five implants in 2 patients failed (survival rate: 95.4%).Mean ΔIBL in group 1 (T1: 6–12 months after surgery) was −0.65 ± 0.82mm and −0.69 ± 0.82mm in group 2 (T1: >12 months after surgery) (

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Antimicrobial photodynamic therapy (PDT) has attracted much attention for the treatment of pathogenic biofilm associated with peridontitis and peri-implantitis. However, data from randomized controlled clinical studies (RCTs) are limited and, to some extent, controversial, making it difficult to provide appropriate recommendations. Therefore, the aims of the present study were (a) to provide an overview on the current evidence from RCTs evaluating the potential clinical benefit for the additional use of PDT to subgingival mechanical debridement (ie, scaling and root planing) alone in nonsurgical periodontal therapy; and (b) to provide clinical recommendations for the use of PDT in periodontal practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM To systematically assess the efficacy of patient-administered mechanical and/or chemical plaque control protocols in the management of peri-implant mucositis (PM). MATERIAL AND METHODS Randomized (RCTs) and Controlled Clinical Trials (CCTs) were identified through an electronic search of three databases complemented by manual search. Identification, screening, eligibility and inclusion of studies was performed independently by two reviewers. Studies without professional intervention or with only mechanical debridement professionally administered were included. Quality assessment was performed by means of the Cochrane Collaboration's tool for assessing risk of bias. RESULTS Eleven RCTs with a follow-up from 3 to 24 months were included. Definition of PM was lacking or heterogeneously reported. Complete resolution of PM was not achieved in any study. One study reported 38% of patients with complete resolution of PM. Surrogate end-point outcomes of PM therapy were often reported. The choice of control interventions showed great variability. The efficacy of powered toothbrushes, a triclosan-containing toothpaste and adjunctive antiseptics remains to be established. High quality of methods and reporting was found in four studies. CONCLUSIONS Professionally- and patient-administered mechanical plaque control alone should be considered the standard of care in the management of PM. Therapy of PM is a prerequisite for the prevention of peri-implantitis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS Over the past decades, the placement of dental implants has become a routine procedure in the oral rehabilitation of fully and partially edentulous patients. However, the number of patients/implants affected by peri-implant diseases is increasing. As there are--in contrast to periodontitis--at present no established and predictable concepts for the treatment of peri-implantitis, primary prevention is of key importance. The management of peri-implant mucositis is considered as a preventive measure for the onset of peri-implantitis. Therefore, the remit of this working group was to assess the prevalence of peri-implant diseases, as well as risks for peri-implant mucositis and to evaluate measures for the management of peri-implant mucositis. METHODS Discussions were informed by four systematic reviews on the current epidemiology of peri-implant diseases, on potential risks contributing to the development of peri-implant mucositis, and on the effect of patient and of professionally administered measures to manage peri-implant mucositis. This consensus report is based on the outcomes of these systematic reviews and on the expert opinion of the participants. RESULTS Key findings included: (i) meta-analysis estimated a weighted mean prevalence for peri-implant mucositis of 43% (CI: 32-54%) and for peri-implantitis of 22% (CI: 14-30%); (ii) bleeding on probing is considered as key clinical measure to distinguish between peri-implant health and disease; (iii) lack of regular supportive therapy in patients with peri-implant mucositis was associated with increased risk for onset of peri-implantitis; (iv) whereas plaque accumulation has been established as aetiological factor, smoking was identified as modifiable patient-related and excess cement as local risk indicator for the development of peri-implant mucositis; (v) patient-administered mechanical plaque control (with manual or powered toothbrushes) has been shown to be an effective preventive measure; (vi) professional intervention comprising oral hygiene instructions and mechanical debridement revealed a reduction in clinical signs of inflammation; (vii) adjunctive measures (antiseptics, local and systemic antibiotics, air-abrasive devices) were not found to improve the efficacy of professionally administered plaque removal in reducing clinical signs of inflammation. CONCLUSIONS Consensus was reached on recommendations for patients with dental implants and oral health care professionals with regard to the efficacy of measures to manage peri-implant mucositis. It was particularly emphasized that implant placement and prosthetic reconstructions need to allow proper personal cleaning, diagnosis by probing and professional plaque removal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The treatment of infectious diseases affecting osseointegrated implants in function has become a demanding issue in implant dentistry. Since the early 1990s, preclinical data from animal studies have provided important insights into the etiology, pathogenesis and therapy of peri-implant diseases. Established lesions in animals have shown many features in common with those found in human biopsy material. The current review focuses on animal studies, employing different models to induce peri-implant mucositis and peri-implantitis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES To objectively determine the difference in colour between the peri-implant soft tissue at titanium and zirconia abutments. MATERIALS AND METHODS Eleven patients, each with two contralaterally inserted osteointegrated dental implants, were included in this study. The implants were restored either with titanium abutments and porcelain-fused-to-metal crowns, or with zirconia abutments and ceramic crowns. Prior and after crown cementation, multi-spectral images of the peri-implant soft tissues and the gingiva of the neighbouring teeth were taken with a colorimeter. The colour parameters L*, a*, b*, c* and the colour differences ΔE were calculated. Descriptive statistics, including non-parametric tests and correlation coefficients, were used for statistical analyses of the data. RESULTS Compared to the gingiva of the neighbouring teeth, the peri-implant soft tissue around titanium and zirconia (test group), showed distinguishable ΔE both before and after crown cementation. Colour differences around titanium were statistically significant different (P = 0.01) only at 1 mm prior to crown cementation compared to zirconia. Compared to the gingiva of the neighbouring teeth, statistically significant (P < 0.01) differences were found for all colour parameter, either before or after crown cementation for both abutments; more significant differences were registered for titanium abutments. Tissue thickness correlated positively with c*-values for titanium at 1 mm and 2 mm from the gingival margin. CONCLUSIONS Within their limits, the present data indicate that: (i) The peri-implant soft tissue around titanium and zirconia showed colour differences when compared to the soft tissue around natural teeth, and (ii) the peri-implant soft tissue around zirconia demonstrated a better colour match to the soft tissue at natural teeth than titanium.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although the placement of dental and orthopedic implants is now generally a safe, reliable and successful undertaking, the functional outcome is less assured in patients whose bone-healing capacity is compromised. To enhance peri-implant osteogenesis in these individuals, BMP-2 could be locally administered. However, neither a free suspension nor an implant-adsorbed depot of the agent is capable of triggering sustained bone formation. We hypothesize that this end could be achieved by incorporating BMP-2 into the three-dimensional crystalline latticework of a bone-mineral like, calcium-phosphate implant coating, where from it would be liberated gradually - as the inorganic layer undergoes osteoclast-mediated degradation - not rapidly, as from an implant-adsorbed (two-dimensional) depot. To test this postulate, we compared the osteoinductive efficacies of implant coatings bearing either an incorporated, an adorbed, or an incorporated and an adsorbed depot of BMP-2 at a maxillary site in miniature pigs. The implants were retrieved 1, 2 and 3 weeks after surgery for the histomorphometric analysis of bone formation within a defined 'osteoinductive' space. At each juncture, the volume of newly-formed bone within the osteoinductive space was greatest around implants that bore a coating-incorporated depot of BMP-2, peak osteogenic activity being attained during the first week and sustained thereafter. In the other groups, the temporal course of bone formation was variable, and the peak levels were not sustained. The findings of this study confirm our hypothesis: they demonstrate that we now have at our disposal a means of efficaciously augmenting and expediting peri-implant bone formation. Clinically, this possibility would render the process of implant placement a safer and a more reliable undertaking in patients whose bone-healing capacity is compromised, and would also permit a curtailment of the postoperative recovery period by a forestallment of the mechanical-loading phase.