35 resultados para PAIR DISTRIBUTION FUNCTION


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The results of a search for direct pair production of the scalar partner to the top quark using an integrated luminosity of 20.1fb−1 of proton-proton collision data at s√=8 TeV recorded with the ATLAS detector at the LHC are reported. The top squark is assumed to decay via t~→tχ~01 or t~→bχ~±1→bW(∗)χ~01, where χ~01 (χ~±1) denotes the lightest neutralino (chargino) in supersymmetric models. The search targets a fully-hadronic final state in events with four or more jets and large missing transverse momentum. No significant excess over the Standard Model background prediction is observed, and exclusion limits are reported in terms of the top squark and neutralino masses and as a function of the branching fraction of t~→tχ~01. For a branching fraction of 100%, top squark masses in the range 270-645 GeV are excluded for χ~01 masses below 30 GeV. For a branching fraction of 50% to either t~→tχ~01 or t~→bχ~±1, and assuming the χ~±1 mass to be twice the χ~01 mass, top squark masses in the range 250-550 GeV are excluded for χ~01 masses below 60 GeV.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Surgical robots have been proposed ex vivo to drill precise holes in the temporal bone for minimally invasive cochlear implantation. The main risk of the procedure is damage of the facial nerve due to mechanical interaction or due to temperature elevation during the drilling process. To evaluate the thermal risk of the drilling process, a simplified model is proposed which aims to enable an assessment of risk posed to the facial nerve for a given set of constant process parameters for different mastoid bone densities. The model uses the bone density distribution along the drilling trajectory in the mastoid bone to calculate a time dependent heat production function at the tip of the drill bit. Using a time dependent moving point source Green's function, the heat equation can be solved at a certain point in space so that the resulting temperatures can be calculated over time. The model was calibrated and initially verified with in vivo temperature data. The data was collected in minimally invasive robotic drilling of 12 holes in four different sheep. The sheep were anesthetized and the temperature elevations were measured with a thermocouple which was inserted in a previously drilled hole next to the planned drilling trajectory. Bone density distributions were extracted from pre-operative CT data by averaging Hounsfield values over the drill bit diameter. Post-operative [Formula: see text]CT data was used to verify the drilling accuracy of the trajectories. The comparison of measured and calculated temperatures shows a very good match for both heating and cooling phases. The average prediction error of the maximum temperature was less than 0.7 °C and the average root mean square error was approximately 0.5 °C. To analyze potential thermal damage, the model was used to calculate temperature profiles and cumulative equivalent minutes at 43 °C at a minimal distance to the facial nerve. For the selected drilling parameters, temperature elevation profiles and cumulative equivalent minutes suggest that thermal elevation of this minimally invasive cochlear implantation surgery may pose a risk to the facial nerve, especially in sclerotic or high density mastoid bones. Optimized drilling parameters need to be evaluated and the model could be used for future risk evaluation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The production of electron–positron pairs in time-dependent electric fields (Schwinger mechanism) depends non-linearly on the applied field profile. Accordingly, the resulting momentum spectrum is extremely sensitive to small variations of the field parameters. Owing to this non-linear dependence it is so far unpredictable how to choose a field configuration such that a predetermined momentum distribution is generated. We show that quantum kinetic theory along with optimal control theory can be used to approximately solve this inverse problem for Schwinger pair production. We exemplify this by studying the superposition of a small number of harmonic components resulting in predetermined signatures in the asymptotic momentum spectrum. In the long run, our results could facilitate the observation of this yet unobserved pair production mechanism in quantum electrodynamics by providing suggestions for tailored field configurations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION Known genetic variants with reference to preeclampsia only explain a proportion of the heritable contribution to the development of this condition. The association between preeclampsia and the risk of cardiovascular disease later in life has encouraged the study of genetic variants important in thrombosis and vascular inflammation also in relation to preeclampsia. The von Willebrand factor-cleaving protease, ADAMTS13, plays an important role in micro vascular thrombosis, and partial deficiencies of this enzyme have been observed in association with cardiovascular disease and preeclampsia. However, it remains unknown whether decreased ADAMTS13 levels represent a cause or an effect of the event in placental and cardiovascular disease. METHODS We studied the distribution of three functional genetic variants of ADAMTS13, c.1852C>G (rs28647808), c.4143_4144dupA (rs387906343), and c.3178C>T (rs142572218) in women with preeclampsia and their controls in a nested case-control study from the second Nord-Trøndelag Health Study (HUNT2). We also studied the association between ADAMTS13 activity and preeclampsia, in serum samples procured unrelated in time of the preeclamptic pregnancy. RESULTS No differences were observed in genotype, allele or haplotype frequencies of the different ADAMTS13 variants when comparing cases and controls, and no association to preeclampsia was found with lower levels of ADAMTS13 activity. CONCLUSION Our findings indicate that ADAMTS13 variants and ADAMTS13 activity do not contribute to an increased risk of preeclampsia in the general population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Proton therapy is a high precision technique in cancer radiation therapy which allows irradiating the tumor with minimal damage to the surrounding healthy tissues. Pencil beam scanning is the most advanced dose distribution technique and it is based on a variable energy beam of a few millimeters FWHM which is moved to cover the target volume. Due to spurious effects of the accelerator, of dose distribution system and to the unavoidable scattering inside the patient's body, the pencil beam is surrounded by a halo that produces a peripheral dose. To assess this issue, nuclear emulsion films interleaved with tissue equivalent material were used for the first time to characterize the beam in the halo region and to experimentally evaluate the corresponding dose. The high-precision tracking performance of the emulsion films allowed studying the angular distribution of the protons in the halo. Measurements with this technique were performed on the clinical beam of the Gantry1 at the Paul Scherrer Institute. Proton tracks were identified in the emulsion films and the track density was studied at several depths. The corresponding dose was assessed by Monte Carlo simulations and the dose profile was obtained as a function of the distance from the center of the beam spot.