39 resultados para OTO
Resumo:
Local skin flaps can be divided into two types: random flaps and axial flaps. An axial flap is defined as a flap containing a named artery in its pedicle. For the paramedian forehead flap (PMFF) a lot of surgeons insist on the point that the pedicle must contain the supratrochlear artery. To demonstrate that median forehead flaps (MFF) need not contain a named artery, we selected first 8 patients with a PMFF and further 12 patients who had undergone reconstructive surgery using a MFF. After division, we analysed the pedicle of the flap histologically and measured the diameter of the arteries or arterioles and compared them to anatomical descriptions of the frontal arteries. In none of the 12 cases could we find a functional artery of approximately 1 mm in diameter that could correspond to the supratrochlear artery. The MFF is an axial flap but not in accordance with the current definition of this term. In contrast to published literature, we show that only in a part of cases a named artery was present in the pedicle. Despite this fact, the MFF is a secure flap for full thickness defect repair on the nose.
Resumo:
Abstract Conclusions: Specific requests for cochlear implantations by persons with psychogenic hearing loss are a relatively new phenomenon. A number of features seems to be over-represented in this group of patients. The existence of these requests stresses the importance of auditory brainstem response (ABR) measurements before cochlear implantation. Objective: To describe the phenomenon of patients with psychogenic hearing losses specifically requesting cochlear implantation, and to gain first insights into the characteristics of this group. Methods: Analysis of all cases seen between 2004 and 2013 at the University Hospital of Bern, Switzerland. Results: Four cochlear implant candidates with psychogenic hearing loss were identified. All were female, aged 23-51 years. Hearing thresholds ranged from 86 dB to 112 dB HL (pure-tone average 500-4000 Hz). ABRs and otoacoustic emissions (OAEs) showed bilaterally normal hearing in two subjects, and hearing thresholds between 30 and 50 dB in the other two subjects. Three subjects suffered from depression and one from a pathologic fear of cancer. Three had a history of five or more previous surgeries. Three were smokers and three reported other close family members with hearing losses. All four were hearing aid users at the time of presentation.
Resumo:
Sharp neck injuries in suicidal intention often present as serious emergency situations with the need for an immediate diagnosis and treatment. We report our study of the clinical evolution of this emergency condition. This study investigates the cases of sharp neck injuries in suicidal intention treated at our institution between 2000 and 2010. Patient records were collected in a retrospectively reviewed and analyzed database. The current literature was compared to our findings. We found 36 cases (10 female and 26 male). The neck injuries were superficial and profound in 16 and 20 patients, respectively. Twenty-two patients were seen by the Head and Neck surgeon. A surgical neck exploration was necessary in 19 cases. Tracheal, laryngeal, pharyngeal and vascular injuries were found in one, five, three and three cases, respectively. The hospital stay ranged from 1 to 47 days. All the patients underwent emergency psychiatric assessment and were subsequently referred for psychiatric treatment. One patient died in the emergency room from an additional arterial injury to the wrist. Sharp neck injuries in suicidal intention treated with an interdisciplinary medical, surgical and psychiatric emergency assessment and treatment have low mortality and morbidity.
Resumo:
A retrospective evaluation of glass ionomer cement (GIC) in middle ear surgery with emphasis on short- and long-term safety was conducted at the tertiary referral center. GIC was applied between 1995 and 2006 in 444 patients in otologic surgery. Technical aspects, safety, benefits and complications due to GIC were analysed until 2011 (follow-up 5-16 years; mean 10 years). GIC was applied in stapes surgery (228 primary, 92 revisions), cochlear implants (108) and implantable hearing aids (7), ossiculoplasty (7), for coverage of opened mastoid air cells towards the external ear canal (1) and inner ear fistula closure (1). GIC turned out to be very handy in stapes surgery for optimal prosthesis fixation at the incus (260) and on the malleus handle (60) without complications. Results suggest that GIC may diminish the danger of incus necrosis in primary stapedotomy. In cochlear implants and implantable hearing aids, GIC was used for casing alone (74), casing and electrode fixation (27) and electrode alone fixation (14). Inflammatory reactions were observed in five cases (4.3 %), mostly after trauma. Broken cement fragments appeared to promote foreign body rejection. In seven cases an incudo-stapedial gap was repaired with GIC with excellent hearing gain; in three cases (43 %) revision surgery was needed due to cement breakage. In one case, GIC was applied for a watertight coverage of opened mastoid cells, and in the other for fistula closure of the lateral semi-circular canal over cartilage, covered with bone pathé; follow-up was uneventful. Targeted use of GIC in middle ear surgery rarely poses problems. GIC cannot be used in neuro-otosurgery in contact with cerebrospinal fluid because of possible aluminium encephalopathy.
Resumo:
Atrial fibrillation (AF) is the most common sustained arrhythmia in the general population. As an age-related arrhythmia AF is becoming a huge socio-economic burden for European healthcare systems. Despite significant progress in our understanding of the pathophysiology of AF, therapeutic strategies for AF have not changed substantially and the major challenges in the management of AF are still unmet. This lack of progress may be related to the multifactorial pathogenesis of atrial remodelling and AF that hampers the identification of causative pathophysiological alterations in individual patients. Also, again new mechanisms have been identified and the relative contribution of these mechanisms still has to be established. In November 2010, the European Union launched the large collaborative project EUTRAF (European Network of Translational Research in Atrial Fibrillation) to address these challenges. The main aims of EUTRAF are to study the main mechanisms of initiation and perpetuation of AF, to identify the molecular alterations underlying atrial remodelling, to develop markers allowing to monitor this processes, and suggest strategies to treat AF based on insights in newly defined disease mechanisms. This article reports on the objectives, the structure, and initial results of this network.
Resumo:
Conclusion Using a second bone anchored hearing implant (BAHI) mounted on a testband in unilaterally implanted BAHI users to test its potential advantage pre-operatively under-estimates the advantage of two BAHIs placed on two implants. Objectives To investigate how well speech understanding with a second BAHI mounted on a testband approaches the benefit of bilaterally implanted BAHIs. Method Prospective study with 16 BAHI users. Eight were implanted unilaterally (group A) and eight were implanted bilaterally (group B). Aided speech understanding was measured. Speech was presented from the front and noise came either from the left, right, or from the front in two conditions for group A (with one BAHI, and with two BAHIs, where the second device was mounted on a testband) and in three conditions for group B (same two conditions as group A, and in addition with both BAHIs mounted on implants). Results Speech understanding in noise improved with the additional device for noise from the side of the first BAHI (+0.7 to +2.1 dB) and decreased for noise from the other side (-1.8 dB to -3.9 dB). Improvements were highest (+2.1 dB, p = 0.016) and disadvantages were smallest (-1.8 dB, p = 0.047) with both BAHIs mounted on implants. Testbands yielded smaller advantages and higher disadvantages of the additional BAHI (average difference = -0.9 dB).
Resumo:
CONCLUSION Bone conduction implants are useful in patients with conductive and mixed hearing loss for whom conventional surgery or hearing aids are no longer an option. They may also be used in patients affected by single-sided deafness. OBJECTIVES To establish a consensus on the quality standards required for centers willing to create a bone conduction implant program. METHOD To ensure a consistently high level of service and to provide patients with the best possible solution the members of the HEARRING network have established a set of quality standards for bone conduction implants. These standards constitute a realistic minimum attainable by all implant clinics and should be employed alongside current best practice guidelines. RESULTS Fifteen items are thoroughly analyzed. They include team structure, accommodation and clinical facilities, selection criteria, evaluation process, complete preoperative and surgical information, postoperative fitting and assessment, follow-up, device failure, clinical management, transfer of care and patient complaints.
Resumo:
The currently presented large dataset (n = 1,422) consists of results that have been assembled over the last 8 years at science fairs using the 16-item odor identification part of the "Sniffin' Sticks". In this context, the focus was on olfactory function in children; in addition before testing, we asked participants to rate their olfactory abilities and the patency of the nasal airways. We reinvestigated some simple questions, e.g., differences in olfactory odor identification abilities in relation to age, sex, self-ratings of olfactory function and nasal patency. Three major results evolved: first, consistent with previously published reports, we found that identification scores of the youngest and the oldest participants were lower than the scores obtained by people aged 20-60. Second, we observed an age-related increase in the olfactory abilities of children. Moreover, the self-assessed olfactory abilities were related to actual performance in the smell test, but only in adults, and self-assessed nasal patency was not related to the "Sniffin' Sticks" identification score.
Resumo:
The head impulse test (HIT) can identify a deficient vestibulo-ocular reflex (VOR) by the compensatory saccade (CS) generated once the head stops moving. The inward HIT is considered safer than the outward HIT, yet might have an oculomotor advantage given that the subject would presumably know the direction of head rotation. Here, we compare CS latencies following inward (presumed predictable) and outward (more unpredictable) HITs after acute unilateral vestibular nerve deafferentation. Seven patients received inward and outward HITs delivered at six consecutive postoperative days (POD) and again at POD 30. All head impulses were recorded by portable video-oculography. CS included those occurring during (covert) or after (overt) head rotation. Inward HITs included mean CS latencies (183.48 ms ± 4.47 SE) that were consistently shorter than those generated during outward HITs in the first 6 POD (p = 0.0033). Inward HITs induced more covert saccades compared to outward HITs, acutely. However, by POD 30 there were no longer any differences in latencies or proportions of CS and direction of head rotation. Patients with acute unilateral vestibular loss likely use predictive cues of head direction to elicit early CS to keep the image centered on the fovea. In acute vestibular hypofunction, inwardly applied HITs may risk a preponderance of covert saccades, yet this difference largely disappears within 30 days. Advantages of inwardly applied HITs are discussed and must be balanced against the risk of a false-negative HIT interpretation.