75 resultados para Non-invasive method


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND The assessment of hemodynamic status is a crucial task in the initial evaluation of trauma patients. However, blood pressure and heart rate are often misleading, as multiple variables may impact these conventional parameters. More reliable methods such as pulmonary artery thermodilution for cardiac output measuring would be necessary, but its applicability in the Emergency Department is questionable due to their invasive nature. Non-invasive cardiac output monitoring devices may be a feasible alternative. METHODS A systematic literature review was conducted. Only studies that explicitly investigated non-invasive hemodynamic monitoring devices in trauma patients were considered. RESULTS A total of 7 studies were identified as suitable and were included into this review. These studies evaluated in a total of 1,197 trauma patients the accuracy of non-invasive hemodynamic monitoring devices by comparing measurements to pulmonary artery thermodilution, which is the gold standard for cardiac output measuring. The correlation coefficients r between the two methods ranged from 0.79 to 0.92. Bias and precision analysis ranged from -0.02 +/- 0.78 l/min/m(2) to -0.14 +/- 0.73 l/min/m(2). Additionally, data on practicality, limitations and clinical impact of the devices were collected. CONCLUSION The accuracy of non-invasive cardiac output monitoring devices in trauma patients is broadly satisfactory. As the devices can be applied very early in the shock room or even preclinically, hemodynamic shock may be recognized much earlier and therapeutic interventions could be applied more rapidly and more adequately. The devices can be used in the daily routine of a busy ED, as they are non-invasive and easy to master.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES To evaluate the diagnostic performance of seven non-invasive tests (NITs) of liver fibrosis and to assess fibrosis progression over time in HIV/HCV co-infected patients. METHODS Transient elastography (TE) and six blood tests were compared to histopathological fibrosis stage (METAVIR). Participants were followed over three years with NITs at yearly intervals. RESULTS Area under the receiver operating characteristic curve (AUROC) for significant fibrosis (> = F2) in 105 participants was highest for TE (0.85), followed by FIB-4 (0.77), ELF-Test (0.77), APRI (0.76), Fibrotest (0.75), hyaluronic acid (0.70), and Hepascore (0.68). AUROC for cirrhosis (F4) was 0.97 for TE followed by FIB-4 (0.91), APRI (0.89), Fibrotest (0.84), Hepascore (0.82), ELF-Test (0.82), and hyaluronic acid (0.79). A three year follow-up was completed by 87 participants, all on antiretroviral therapy and in 20 patients who completed HCV treatment (9 with sustained virologic response). TE, APRI and Fibrotest did not significantly change during follow-up. There was weak evidence for an increase of FIB-4 (mean increase: 0.22, p = 0.07). 42 participants had a second liver biopsy: Among 38 participants with F0-F3 at baseline, 10 were progessors (1-stage increase in fibrosis, 8 participants; 2-stage, 1; 3-stage, 1). Among progressors, mean increase in TE was 3.35 kPa, in APRI 0.36, and in FIB-4 0.75. Fibrotest results did not change over 3 years. CONCLUSION TE was the best NIT for liver fibrosis staging in HIV/HCV co-infected patients. APRI-Score, FIB-4 Index, Fibrotest, and ELF-Test were less reliable. Routinely available APRI and FIB-4 performed as good as more expensive tests. NITs did not change significantly during a follow-up of three years, suggesting slow liver disease progression in a majority of HIV/HCV co-infected persons on antiretroviral therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A body was found behind a car with a noose tied around its neck, the other end of the rope tied to a tree. Apparently the man committed suicide by driving away with the noose tied around his neck and was dragged out of the car through the open hatchback. postmortem multislice-computed tomography (MSCT) and magnetic resonance imaging (MRI) indicated that the cause of death was cerebral hypoxia due to classic strangulation by hanging, and not due to a brainstem lesion because of a hang-man fracture as would be expected in such a dynamic situation. Furthermore, the MRI displayed intramuscular haemorrhage, bleeding into the clavicular insertions of the sternocleidomastoid muscles and subcutaneous neck tissue. We conclude that MSCT and MRI are useful instruments with an increased value compared with 2D radiographs to augment the external findings of bodies when an autopsy is refused. But further postmortem research and comparing validation is needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of infrared thermography for the identification of lameness in cattle has increased in recent years largely because of its non-invasive properties, ease of automation and continued cost reductions. Thermography can be used to identify and determine thermal abnormalities in animals by characterizing an increase or decrease in the surface temperature of their skin. The variation in superficial thermal patterns resulting from changes in blood flow in particular can be used to detect inflammation or injury associated with conditions such as foot lesions. Thermography has been used not only as a diagnostic tool, but also to evaluate routine farm management. Since 2000, 14 peer reviewed papers which discuss the assessment of thermography to identify and manage lameness in cattle have been published. There was a large difference in thermography performance in these reported studies. However, thermography was demonstrated to have utility for the detection of contralateral temperature difference and maximum foot temperature on areas of interest. Also apparent in these publications was that a controlled environment is an important issue that should be considered before image scanning.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Concurrent analysis of antibiotic resistance of colonising and invasive Streptococcus pneumoniae gives a more accurate picture than looking at either of them separately. Therefore, we analysed 2,129 non-invasive and 10,996 invasive pneumococcal isolates from Switzerland from 2004 to 2014, which spans the time before and after the introduction of the heptavalent (PCV7) and 13-valent (PCV13) conjugated pneumococcal polysaccharide vaccines. Serotype/serogroup information was linked with all antibiotic resistance profiles. During the study period, the proportion of non-susceptible non-invasive and invasive isolates significantly decreased for penicillin, ceftriaxone, erythromycin and trimethoprim/sulfamethoxazole (TMP-SMX). This was most apparent in non-invasive isolates from study subjects younger than five years (penicillin (p = 0.006), erythromycin (p = 0.01) and TMP-SMX (p = 0.002)). Resistant serotypes/serogroups included in PCV7 and/or PCV13 decreased and were replaced by non-PCV13 serotypes (6C and 15B/C). Serotype/serogroup-specific antibiotic resistance rates were comparable between invasive and non-invasive isolates. Adjusted odds ratios of serotype/serogroup-specific penicillin resistance were significantly higher in the west of Switzerland for serotype 6B (1.8; 95% confidence interval (CI): 1.4-4.8), 9V (3.4; 95% CI: 2.0-5.7), 14 (5.3; 95% CI: 3.8-7.5), 19A (2.2; 95% CI: 1.6-3.1) and 19F (3.1; 95% CI: 2.1-4.6), probably due to variations in the antibiotic consumption.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study validated the accuracy of data from a self-reported questionnaire on smoking behaviour with the use of exhaled carbon monoxide (CO) level measurements in two groups of patients. Group 1 included patients referred to an oral medicine unit, whereas group 2 was recruited from the daily outpatient service. All patients filled in a standardized questionnaire regarding their current and former smoking habits. Additionally, exhaled CO levels were measured using a monitor. A total of 121 patients were included in group 1, and 116 patients were included in group 2. The mean value of exhaled CO was 7.6 ppm in the first group and 9.2 ppm in the second group. The mean CO values did not statistically significantly differ between the two groups. The two exhaled CO level measurements taken for each patient exhibited very good correlation (Spearman's coefficient of 0.9857). Smokers had a mean difference of exhaled CO values of 13.95 ppm (p < 0.001) compared to non-smokers adjusted for the first or second group. The consumption of one additional pack year resulted in an increase in CO values of 0.16 ppm (p = 0.003). The consumption of one additional cigarette per day elevated the CO measurements by 0.88 ppm (p < 0.001). Based on these results, the correlations between the self-reported smoking habits and exhaled CO values are robust and highly reproducible. CO monitors may offer a non-invasive method to objectively assess current smoking behaviour and to monitor tobacco use cessation attempts in the dental setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND The diagnostic performance of biochemical scores and artificial neural network models for portal hypertension and cirrhosis is not well established. AIMS To assess diagnostic accuracy of six serum scores, artificial neural networks and liver stiffness measured by transient elastography, for diagnosing cirrhosis, clinically significant portal hypertension and oesophageal varices. METHODS 202 consecutive compensated patients requiring liver biopsy and hepatic venous pressure gradient measurement were included. Several serum tests (alone and combined into scores) and liver stiffness were measured. Artificial neural networks containing or not liver stiffness as input variable were also created. RESULTS The best non-invasive method for diagnosing cirrhosis, portal hypertension and oesophageal varices was liver stiffness (C-statistics=0.93, 0.94, and 0.90, respectively). Among serum tests/scores the best for diagnosing cirrhosis and portal hypertension and oesophageal varices were, respectively, Fibrosis-4, and Lok score. Artificial neural networks including liver stiffness had high diagnostic performance for cirrhosis, portal hypertension and oesophageal varices (accuracy>80%), but were not statistically superior to liver stiffness alone. CONCLUSIONS Liver stiffness was the best non-invasive method to assess the presence of cirrhosis, portal hypertension and oesophageal varices. The use of artificial neural networks integrating different non-invasive tests did not increase the diagnostic accuracy of liver stiffness alone.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

NAFLD (non-alcoholic fatty liver disease) and NASH (non-alcoholic steatohepatitis) are of increasing importance, both in connection with insulin resistance and with the development of liver cirrhosis. Histological samples are still the 'gold standard' for diagnosis; however, because of the risks of a liver biopsy, non-invasive methods are needed. MAS (magic angle spinning) is a special type of NMR which allows characterization of intact excised tissue without need for additional extraction steps. Because clinical MRI (magnetic resonance imaging) and MRS (magnetic resonance spectroscopy) are based on the same physical principle as NMR, translational research is feasible from excised tissue to non-invasive examinations in humans. In the present issue of Clinical Science, Cobbold and co-workers report a study in three animal strains suffering from different degrees of NAFLD showing that MAS results are able to distinguish controls, fatty infiltration and steatohepatitis in cohorts. In vivo MRS methods in humans are not obtainable at the same spectral resolution; however, know-how from MAS studies may help to identify characteristic changes in crowded regions of the magnetic resonance spectrum.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES Application of the recently developed optical method based on the monitoring of the specular reflection intensity to study the protective potential of the salivary pellicle layer against early enamel erosion. METHODS The erosion progression was compared between two treatment groups: enamel samples coated by the 15 h-in vitro-formed salivary pellicle layer (group P, n=90) and the non-coated enamel surfaces (control group C, n=90). Different severity of the erosive impact was modelled by the enamel incubation in 1% citric acid (pH=3.6) for 2, 4, 8, 10 or 15 min. Erosion quantification was performed by the optical method as well as by the microhardness and calcium release analyses. RESULTS Optical assessment of the erosion progression showed erosion inhibition by the in vitro salivary pellicle in short term acidic treatments (≤ 4 min) which was also confirmed by microhardness measurements proving significantly less (p<0.05) enamel softening in the group P at 2 and 4 min of erosion compared to the group C. SEM images demonstrated less etched enamel interfaces in the group P at short erosion durations as well. CONCLUSIONS Monitoring of the specular reflection intensity can be successfully applied to quantify early erosion progression in comparative studies. In vitro salivary pellicle (2h) provides erosion inhibition but only in short term acidic exposures. CLINICAL SIGNIFICANCE The proposed optical technique is a promising tool for the fast and non-invasive erosion quantification in clinical studies.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Induced mild hypothermia after cardiac arrest interferes with clinical assessment of the cardiovascular status of patients. In this situation, non-invasive cardiac output measurement could be useful. Unfortunately, arterial pulse contour is altered by temperature, and the performance of devices using arterial blood pressure contour analysis to derive cardiac output may be insufficient.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Conventional MRI may still be an inaccurate method for the non-invasive detection of a microadenoma in adrenocorticotropin (ACTH)-dependent Cushing's syndrome (CS). Bilateral inferior petrosal sinus sampling (BIPSS) with ovine corticotropin-releasing hormone (oCRH) stimulation is an invasive, but accurate, intervention in the diagnostic armamentarium surrounding CS. Until now, there is a continuous controversial debate regarding lateralization data in detecting a microadenoma. Using BIPSS, we evaluated whether a highly selective placement of microcatheters without diversion of venous outflow might improve detection of pituitary microadenoma.