185 resultados para Multi-slice computed tomography


Relevância:

100.00% 100.00%

Publicador:

Resumo:

To determine the frequency of incidental maxillary sinus findings using cone-beam computed tomography (CBCT) images made for orthodontic purposes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

For the determination of brain death (BD) in potential organ donors, confirmatory tests that show cessation of cerebral circulation are used in many countries. Conventional angiography is considered the golden standard among these ancillary examinations. In recent years other angiographic techniques such as CT angiography (CTA) have been increasingly employed to establish the diagnosis of BD. We report our experience with CTA in this setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this pilot investigation was to evaluate the utility and precision of already existing limited cone-beam computed tomography (CBCT) scans in measuring the endodontic working length, and to compare it with standard clinical procedures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To assess retrospectively the frequency and location of mandibular lingual foramina and their bony canals with limited cone-beam computed tomography.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this retrospective radiographic study was to analyze the thickness of the facial bone wall at teeth in the anterior maxilla based on cone beam computed tomography (CBCT) images, since this anatomical structure is important for the selection of an appropriate treatment approach in patients undergoing postextraction implant placement. A total of 125 CBCT scans met the inclusion criteria, resulting in a sample size of 498 teeth. The thickness of the facial bone wall in the respective sagittal scans was measured perpendicular to the long axis of the tooth at two locations: at the crest level (4 mm apical to the cementoenamel junction; MP1) and at the middle of the root (MP2). No existing bone wall was found in 25.7% of all teeth at MP1 and in 10.0% at MP2. The majority of the examined teeth exhibited a thin facial bone wall (< 1 mm; 62.9% at MP1, 80.1% at MP2). A thick bone wall (? 1 mm) was found in only 11.4% of all examined teeth at MP1 and 9.8% at MP2. There was a statistically significant decrease in facial bone wall thickness from the first premolars to the central incisors. The facial bone wall in the crestal area of teeth in the anterior maxilla was either missing or thin in roughly 90.0% of patients. Both a missing and thin facial wall require simultaneous contour augmentation at implant placement because of the well-documented bone resorption that occurs at a thin facial bone wall following tooth extraction. Consequently, radiographic analysis of the facial bone wall using CBCT prior to extraction is recommended for selection of the appropriate treatment approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To determine the dimensions of the Schneiderian membrane using limited cone beam computed tomography (CBCT) in individuals referred for dental implant surgery, and to determine factors influencing the mucosal thickness.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluates the dimensions of nasopalatine duct cysts (NPDCs) and the involvement of neighboring anatomical structures using standardized limited cone beam computed tomography (CBCT) and a possible correlation to the patient's age, gender, preoperative symptoms, and postsurgical complications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate the detectability and dimensions of periapical lesions, the relationship of the mandibular canal to the roots of the respective teeth, and the dimension of the buccal bone by using limited cone-beam computed tomography (CBCT) in comparison to conventional periapical (PA) radiographs for evaluation of mandibular molars before apical surgery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this experimental study was to investigate the effect of tube tension reduction on image contrast and image quality in pediatric temporal bone computed tomography (CT).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: The purpose of our study was to retrospectively evaluate the specificity, sensitivity and accuracy of computed tomography (CT), digital radiography (DR) and low-dose linear slit digital radiography (LSDR, Lodox(®)) in the detection of internal cocaine containers. METHODS: Institutional review board approval was obtained. The study collectively consisted of 83 patients (76 males, 7 females, 16-45 years) suspected of having incorporated cocaine drug containers. All underwent radiological imaging; a total of 135 exams were performed: nCT=35, nDR=70, nLSDR=30. An overall calculation of all "drug mules" and a specific evaluation of body packers, pushers and stuffers were performed. The gold standard was stool examination in a dedicated holding cell equipped with a drug toilet. RESULTS: There were 54 drug mules identified in this study. CT of all drug carriers showed the highest diagnostic accuracy 97.1%, sensitivity 100% and specificity 94.1%. DR in all cases was 71.4% accurate, 58.3% sensitive and 85.3% specific. LSDR of all patients with internal cocaine was 60% accurate, 57.9% sensitive and 63.4% specific. CONCLUSIONS: CT was the most accurate test studied. Therefore, the detection of internal cocaine drug packs should be performed by CT, rather than by conventional X-ray, in order to apply the most sensitive exam in the medico-legal investigation of suspected drug carriers. Nevertheless, the higher radiation applied by CT than by DR or LSDR needs to be considered. Future studies should include evaluation of low dose CT protocols in order to address germane issues and to reduce dosage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to determine the influence of iodinated contrast agents on the formation of DNA double-strand breaks in vitro in lymphocytes and to verify these results in patients undergoing diagnostic computed tomography examinations. Blood samples were irradiated in vitro in the presence of iodinated X-ray contrast agent. Controls were irradiated without contrast agent. Fourteen patients were investigated using contrast-enhanced computed tomography (CT), and 14 other patients with unenhanced CT. Blood samples were taken prior to and 5 min and 1, 2 and 24 h after the CT examination. In these blood samples the average number of γH2Ax-foci per lymphocyte was enumerated by fluorescence microscopy. Statistical differences between foci numbers developed in the presence and absence of contrast agent were tested using an independent sample t-test. In vitro foci numbers after irradiation were significantly higher when contrast agent was present during irradiation. In vivo, γH2Ax-foci levels were 58% higher in patients undergoing contrast-enhanced CT compared with those undergoing unenhanced CT. In the presence of iodinated contrast agents DNA, damage is increased and the radiation dose is not the only factor affecting the amount of DNA damage. Individual patient characteristics and biological dosimetry applications, e.g. the analysis of γH2Ax-foci, have to be considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new radiation dose-saving technique for noninvasive coronary artery imaging with computed tomography (CT) is available.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We prospectively investigated the potential of positron emission tomography (PET) using the somatostatin receptor (SSTR) analogue ⁶⁸Ga-DOTATATE and 2-deoxy-2[¹⁸F]fluoro-D-glucose (¹⁸F-FDG) in diffuse parenchymal lung disease (DPLD). Twenty-six patients (mean age 68.9 ± 11.0 years) with DPLD were recruited for ⁶⁸Ga-DOTATATE and ¹⁸F-FDG combined PET/high-resolution computed tomography (HRCT) studies. Ten patients had idiopathic pulmonary fibrosis (IPF), 12 patients had nonspecific interstitial pneumonia (NSIP), and 4 patients had other forms of DPLD. Using PET, the pulmonary tracer uptake (maximum standardized uptake value [SUV(max)]) was calculated. The distribution of PET tracer was compared to the distribution of lung parenchymal changes on HRCT. All patients demonstrated increased pulmonary PET signal with ⁶⁸Ga-DOTATATE and ¹⁸F-FDG. The distribution of parenchymal uptake was similar, with both tracers corresponding to the distribution of HRCT changes. The mean SUV(max) was 2.2 ± 0.7 for ⁶⁸Ga-DOTATATE and 2.8 ± 1.0 (t-test, p  =  .018) for ¹⁸F-FDG. The mean ⁶⁸Ga-DOTATATE SUV(max) in IPF patients was 2.5 ± 0.9, whereas it was 2.0 ± 0.7 (p  =  .235) in NSIP patients. The correlation between ⁶⁸Ga-DOTATATE SUV(max) and gas transfer (transfer factor of the lung for carbon monoxide [TLCO]) was r  =  -.34 (p  =  .127) and r  =  -.49 (p  =  .028) between ¹⁸F-FDG SUV(max) and TLCO. We provide noninvasive in vivo evidence in humans showing that SSTRs may be detected in the lungs of patients with DPLD in a similar distribution to sites of increased uptake of ¹⁸F-FDG on PET.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The determination of root canal length is a significant outcome predictor for endodontic treatments. The aim of this prospective, controlled clinical study was to analyze endodontic working length measurements in preexisting cone-beam computed tomography (CBCT) scans and to compare them with clinical root canal length determination by using an electronic apex locator (EAL).