63 resultados para Measurement and processing vibrations
Resumo:
Background During production and processing of multi-walled carbon nanotubes (MWCNTs), they may be inhaled and may enter the pulmonary circulation. It is essential that interactions with involved body fluids like the pulmonary surfactant, the blood and others are investigated, particularly as these interactions could lead to coating of the tubes and may affect their chemical and physical characteristics. The aim of this study was to characterize the possible coatings of different functionalized MWCNTs in a cell free environment. Results To simulate the first contact in the lung, the tubes were coated with pulmonary surfactant and subsequently bound lipids were characterized. The further coating in the blood circulation was simulated by incubating the tubes in blood plasma. MWCNTs were amino (NH2)- and carboxyl (-COOH)-modified, in order to investigate the influence on the bound lipid and protein patterns. It was shown that surfactant lipids bind unspecifically to different functionalized MWCNTs, in contrast to the blood plasma proteins which showed characteristic binding patterns. Patterns of bound surfactant lipids were altered after a subsequent incubation in blood plasma. In addition, it was found that bound plasma protein patterns were altered when MWCNTs were previously coated with pulmonary surfactant. Conclusions A pulmonary surfactant coating and the functionalization of MWCNTs have both the potential to alter the MWCNTs blood plasma protein coating and to determine their properties and behaviour in biological systems.
Resumo:
Although magnetic resonance spectroscopy can be used as a unique tool to study molecular diffusion, it is rarely used to measure the diffusion properties of intramyocellular and extramyocellular lipids. Lipids have very low apparent diffusion coefficients (ADCs), which make these measurements difficult and necessitate strong diffusion gradients and long diffusion times. Consequence is that these measurements have inherently low signal-to-noise ratio and are prone to artifacts. The addition of physiological triggering and individual storage and processing of the spectra is seen to be a possible approach to maximize signal intensity and achieve high reproducibility of the experiments. Thus, the optimized measurement protocol was used to investigate the diffusion properties of lipids in human skeletal muscle in vivo. At a diffusion time of about 110 ms, intramyocellular lipids show a significantly lower ADC (2.0 × 10(-6) mm(2)/s, 95% confidence interval 1.10 × 10(-6) to 2.94 × 10(-6) mm(2)/s) than extramyocellular lipids (1.58 × 10(-5) mm(2)/s, 95% confidence interval 1.41 × 10(-5) to 1.75 × 10(-5) mm(2)/s). Because the chemical properties of both lipid pools can be assumed to be similar, the difference can only be attributed to restricted or severely hindered diffusion in the intramyocellular droplets.
Resumo:
The excitonic splitting between the S-1 and S-2 electronic states of the doubly hydrogen-bonded dimer 2-pyridone center dot 6-methyl-2-pyridone (2PY center dot 6M2PY) is studied in a supersonic jet, applying two-color resonant two-photon ionization (2C-R2PI), UV-UV depletion, and dispersed fluorescence spectroscopies. In contrast to the C-2h symmetric (2-pyridone) 2 homodimer, in which the S-1 <- S-0 transition is symmetry-forbidden but the S-2 <- S-0 transition is allowed, the symmetry-breaking by the additional methyl group in 2PY center dot 6M2PY leads to the appearance of both the S-1 and S-2 origins, which are separated by Delta(exp) = 154 cm(-1). When combined with the separation of the S-1 <- S-0 excitations of 6M2PY and 2PY, which is delta = 102 cm(-1), one obtains an S-1/S-2 exciton coupling matrix element of V-AB, el = 57 cm(-1) in a Frenkel-Davydov exciton model. The vibronic couplings in the S-1/S-2 <- S-0 spectrum of 2PY center dot 6M2PY are treated by the Fulton-Gouterman single-mode model. We consider independent couplings to the intramolecular 6a' vibration and to the intermolecular sigma' stretch, and obtain a semi-quantitative fit to the observed spectrum. The dimensionless excitonic couplings are C(6a') = 0.15 and C(sigma') = 0.05, which places this dimer in the weak-coupling limit. However, the S-1/S-2 state exciton splittings Delta(calc) calculated by the configuration interaction singles method (CIS), time-dependent Hartree-Fock (TD-HF), and approximate second-order coupled-cluster method (CC2) are between 1100 and 1450 cm(-1), or seven to nine times larger than observed. These huge errors result from the neglect of the coupling to the optically active intra-and intermolecular vibrations of the dimer, which lead to vibronic quenching of the purely electronic excitonic splitting. For 2PY center dot 6M2PY the electronic splitting is quenched by a factor of similar to 30 (i.e., the vibronic quenching factor is Gamma(exp) = 0.035), which brings the calculated splittings into close agreement with the experimentally observed value. The 2C-R2PI and fluorescence spectra of the tautomeric species 2-hydroxypyridine center dot 6-methyl-2-pyridone (2HP center dot 6M2PY) are also observed and assigned. (C) 2011 American Institute of Physics.
Resumo:
Data on antimicrobial use play a key role in the development of policies for the containment of antimicrobial resistance. On-farm data could provide a detailed overview of the antimicrobial use, but technical and methodological aspects of data collection and interpretation, as well as data quality need to be further assessed. The aims of this study were (1) to quantify antimicrobial use in the study population using different units of measurement and contrast the results obtained, (2) to evaluate data quality of farm records on antimicrobial use, and (3) to compare data quality of different recording systems. During 1 year, data on antimicrobial use were collected from 97 dairy farms. Antimicrobial consumption was quantified using: (1) the incidence density of antimicrobial treatments; (2) the weight of active substance; (3) the used daily dose and (4) the used course dose for antimicrobials for intestinal, intrauterine and systemic use; and (5) the used unit dose, for antimicrobials for intramammary use. Data quality was evaluated by describing completeness and accuracy of the recorded information, and by comparing farmers' and veterinarians' records. Relative consumption of antimicrobials depended on the unit of measurement: used doses reflected the treatment intensity better than weight of active substance. The use of antimicrobials classified as high priority was low, although under- and overdosing were frequently observed. Electronic recording systems allowed better traceability of the animals treated. Recording drug name or dosage often resulted in incomplete or inaccurate information. Veterinarians tended to record more drugs than farmers. The integration of veterinarian and farm data would improve data quality.
Resumo:
OBJECTIVE: Autopsy determination of fatal hemorrhage as the cause of death is often a difficult diagnosis in forensic medicine. No quantitative system for accurately measuring the blood volume in a corpse has been developed. MATERIALS AND METHODS: This article describes the measurement and evaluation of the cross-sectional areas of major blood vessels, of the diameter of the right pulmonary artery, of the volumes of thoracic aorta and spleen on MDCT, and of the volumes of heart chambers on MRI in 65 autopsy-verified cases of fatal hemorrhage or no fatal hemorrhage. RESULTS: Most cases with a cause of death of "fatal hemorrhage" had collapsed vessels. The finding of a collapsed superior vena cava, main pulmonary artery, or right pulmonary artery was 100% specific for fatal hemorrhage. The mean volumes of the thoracic aorta and of each of the heart chambers and the mean cross-sectional areas of all vessels except the inferior vena cava and abdominal aorta were significantly smaller in fatal hemorrhage than in no fatal hemorrhage. CONCLUSION: For the quantitative differentiation of fatal hemorrhage from other causes of death, we propose a three-step algorithm with measurements of the diameter of the right pulmonary artery, the cross-sectional area of the main pulmonary artery, and the volume of the right atrium (specificity, 100%; sensitivity, 95%). However, this algorithm must be corroborated in a prospective study, which would eliminate the limitations of this study. Quantitative postmortem cross-sectional imaging might become a reliable objective method to assess the question of fatal hemorrhage in forensic medicine.
Serological and DNA-based evaluation of Chlamydia pneumoniae infection in inflammatory bowel disease
Resumo:
OBJECTIVES: Chlamydia has been associated with autoimmune diseases, but a link between chlamydial infection and the aetiopathogenesis of inflammatory bowel disease (IBD) remains controversial. In this study we assessed the relationship between chlamydial infection and IBD, as evidenced by serological measurement and DNA analysis of mucosal biopsy specimens. PATIENTS AND METHODS: The sera of 78 patients with Crohn's disease (CD), 24 patients with ulcerative colitis (UC), 73 healthy family members, and 20 healthy controls were tested for anti-C. pneumoniae IgG titres. A subgroup consisting of 13 UC and 39 CD patients was screened for the presence of chlamydial DNA on 42 inflamed versus 30 non-inflamed biopsy specimens and for mutations of their NOD2/CARD15 gene. RESULTS: Anti-C. pneumoniae IgG antibodies were found in the sera of 32 (41%) patients with CD, 11 (46%) patients with UC, 35 (48%) of unaffected family members, and nine (45%) unrelated healthy controls. Thirty-five percent of the control, 18% CD and 24% UC biopsy specimens contained C. pneumoniae DNA. In CD, however, C. pneumoniae DNA was significantly more frequently found in inflamed (27%) versus non-inflamed (8%) biopsy specimens (P < 0.05, Fisher's exact test). The frequencies of NOD2/CARD15 mutations were 33% for CD patients with C. pneumoniae DNA compared to 47% for CD patients without C. pneumoniae DNA. CONCLUSION: We found no marked differences in respect to anti-C. pneumoniae serum IgG or C. pneumoniae DNA between healthy controls and patients with IBD. However, in CD patients, inflamed tissue specimens contained significantly more likely C. pneumoniae DNA compared with biopsies from unaffected areas. Thus C. pneumoniae is unlikely to be of pathogenic importance in IBD while it may still influence local clinical manifestations.
Resumo:
BACKGROUND: Physiological data obtained with the pulmonary artery catheter (PAC) are susceptible to errors in measurement and interpretation. Little attention has been paid to the relevance of errors in hemodynamic measurements performed in the intensive care unit (ICU). The aim of this study was to assess the errors related to the technical aspects (zeroing and reference level) and actual measurement (curve interpretation) of the pulmonary artery occlusion pressure (PAOP). METHODS: Forty-seven participants in a special ICU training program and 22 ICU nurses were tested without pre-announcement. All participants had previously been exposed to the clinical use of the method. The first task was to set up a pressure measurement system for PAC (zeroing and reference level) and the second to measure the PAOP. RESULTS: The median difference from the reference mid-axillary zero level was - 3 cm (-8 to + 9 cm) for physicians and -1 cm (-5 to + 1 cm) for nurses. The median difference from the reference PAOP was 0 mmHg (-3 to 5 mmHg) for physicians and 1 mmHg (-1 to 15 mmHg) for nurses. When PAOP values were adjusted for the differences from the reference transducer level, the median differences from the reference PAOP values were 2 mmHg (-6 to 9 mmHg) for physicians and 2 mmHg (-6 to 16 mmHg) for nurses. CONCLUSIONS: Measurement of the PAOP is susceptible to substantial error as a result of practical mistakes. Comparison of results between ICUs or practitioners is therefore not possible.
Resumo:
In honeybees (Apis niellifera), the process of nectar collection is considered a straightforward example of task partitioning with two subtasks or two intersecting cycles of activity: (1) foraging and (2) storing of nectar, linked via its transfer between foragers and food processors. Many observations suggest, however, that nectar colleclion and processing in honeybees is a complex process, involving workers of other sub-castes and depending on variables such as resource profitability or the amount of stored honey. It has been observed that food processor bees often distribute food to other hive bees after receiving it from incoming foragers, instead of storing it immediately in honey cells. While there is little information about the sub-caste affiliation and the behaviour of these second-order receivers, this stage may be important for the rapid distribution of nutrients and related information. To investigate the identity of these second-order receivers, we quantified behaviours following nectar transfer and compared these behaviours with the behaviour of average worker hive-bees. Furthermore, we tested whether food quality (sugar concentration) affects the behaviour of the second-order receivers. Of all identified second-order receivers, 59.3% performed nurse duties, 18.5% performed food-processor duties and 22.2% performed forager duties. After food intake, these bees were more active, had more trophallaxes (especially offering contacts) compared to average workers and they were found mainly in the brood area, independent of food quality. Our results show that the liquid food can be distributed rapidly among many bees of the three main worker sub-castes, without being stored in honey cells first. Furthermore, the results suggest that the rapid distribution of food partly depends on the high activity of second-order receivers.
Issues of spectral quality in clinical 1H-magnetic resonance spectroscopy and a gallery of artifacts
Resumo:
In spite of the facts that magnetic resonance spectroscopy (MRS) is applied as clinical tool in non-specialized institutions and that semi-automatic acquisition and processing tools can be used to produce quantitative information from MRS exams without expert information, issues of spectral quality and quality assessment are neglected in the literature of MR spectroscopy. Even worse, there is no consensus among experts on concepts or detailed criteria of quality assessment for MR spectra. Furthermore, artifacts are not at all conspicuous in MRS and can easily be taken for true, interpretable features. This article aims to increase interest in issues of spectral quality and quality assessment, to start a larger debate on generally accepted criteria that spectra must fulfil to be clinically and scientifically acceptable, and to provide a sample gallery of artifacts, which can be used to raise awareness for potential pitfalls in MRS.
Resumo:
Whole-body vibration exposure of locomotive engineers and the vibration attenuation of seats in 22 U.S. locomotives (built between 1959 and 2000) was studied during normal revenue service and following international measurement guidelines. Triaxial vibration measurements (duration mean 155 min, range 84-383 min) on the seat and on the floor were compared. In addition to the basic vibration evaluation (aw rms), the vector sum (av), the maximum transient vibration value (MTVV/aw), the vibration dose value (VDV/(aw T1/4)), and the vibration seat effective transmissibility factor (SEAT) were calculated. The power spectral densities are also reported. The mean basic vibration level (aw rms) was for the fore-aft axis x = 0.18 m/sec2, the lateral axis y = 0.28 m/sec2, and the vertical axis z = 0.32 m/sec2. The mean vector sum was 0.59 m/sec2 (range 0.27 to 1.44). The crest factors were generally at or above 9 in the horizontal and vertical axis. The mean MTVV/aw was 5.3 (x), 5.1 (y), and 4.8 (z), and the VDV/(aw T1/4) values ranged from 1.32 to 2.3 (x-axis), 1.33 to 1.7 (y-axis), and 1.38 to 1.86 (z-axis), generally indicating high levels of shocks. The mean seat transmissibility factor (SEAT) was 1.4 (x) and 1.2 (y) and 1 (z), demonstrating a general ineffectiveness of any of the seat suspension systems. In conclusion, these data indicate that locomotive rides are characterized by relatively high shock content (acceleration peaks) of the vibration signal in all directions. Locomotive vertical and lateral vibrations are similar, which appears to be characteristic for rail vehicles compared with many road/off-road vehicles. Tested locomotive cab seats currently in use (new or old) appear inadequate to reduce potentially harmful vibration and shocks transmitted to the seated operator, and older seats particularly lack basic ergonomic features regarding adjustability and postural support.
Resumo:
Target difficulty is often argued to increase performance. While this association is well established in experimental research, empirical evidence in field research is rather mixed. We attempt to explain this inconsistency by analyzing the importance of intra-year target revisions, which are especially prevalent in real-world field settings. Using survey and archival data from 97 firms, we find that firms with more challenging business unit targets revise targets more often, in line with asymmetric, downward target revisions. Results further show that the degree to which targets are revised during a period results in negative effects on firm performance, as the anticipation of revision negatively affects the business unit management’s performance incentives. Additionally, we find that using targets predominantly for either decision-making or control influences the overall performance effects of target revisions. Our findings may partially explain the mixed field study evidence regarding the effects of target difficulty.
Resumo:
The aim of this study was to assess the effect of the moments generated with low- and high-torque brackets. Four different bracket prescription-slot combinations of the same bracket type (Mini Diamond® Twin) were evaluated: high-torque 0.018 and 0.022 inch and low-torque 0.018 and 0.022 inch. These brackets were bonded on identical maxillary acrylic resin models with levelled and aligned teeth and each model was mounted on the orthodontic measurement and simulation system (OMSS). Ten specimens of 0.017 × 0.025 inch and ten 0.019 × 0.025 inch stainless steel archwires (ORMCO) were evaluated in the low- and high-torque 0.018 inch and 0.022 inch brackets, respectively. The wires were ligated with elastomerics into the brackets and each measurement was repeated once after religation. Two-way analysis of variance and t-test were conducted to compare the generated moments between wires at low- and high-torque brackets separately. The maximum moment generated by the 0.017 × 0.025 inch stainless steel archwire in the 0.018 inch brackets at +15 degrees ranged from 14.33 and 12.95 Nmm for the high- and low-torque brackets, respectively. The measured torque in the 0.022 inch brackets with the 0.019 × 0.025 inch stainless steel archwire was 9.32 and 6.48 Nmm, respectively. The recorded differences of maximum moments between the high- and low-torque series were statistically significant. High-torque brackets produced higher moments compared with low-torque brackets. Additionally, in both high- and low-torque configurations, the thicker 0.019 × 0.025 inch steel archwire in the 0.022 inch slot system generated lower moments in comparison with the 0.017 × 0.025 inch steel archwire in the 0.018 inch slot system.
Resumo:
The aim of this study was to assess the effect of bracket type on the labiopalatal moments generated by lingual and conventional brackets. Incognito™ lingual brackets (3M Unitek), STb™ lingual brackets (Light Lingual System; ORMCO), In-Ovation L lingual brackets (DENTSPLY GAC), and conventional 0.018 inch slot brackets (Gemini; 3M Unitek) were bonded on identical maxillary acrylic resin models with levelled and aligned teeth. Each model was mounted on the orthodontic measurement and simulation system and 10 0.0175 × 0.0175 TMA wires were used for each bracket type. The wire was ligated with elastomerics into the Incognito, STb, and conventional brackets and each measurement was repeated once after religation. A 15 degrees buccal root torque (+15 degrees) and then a 15 degrees palatal root torque (-15 degrees) were gradually applied to the right central incisor bracket. After each activation, the bracket returned to its initial position and the moments in the sagittal plane were recorded during these rotations of the bracket. One-way analysis of variance with post hoc multiple comparisons (Tukey test at 0.05 error rate) was conducted to assess the effect on bracket type on the generated moments. The magnitude of maximum moment at +15 degrees ranged 8.8, 8.2, 7.1, and 5.8 Nmm for the Incognito, STb, conventional Gemini, and the In-Ovation L brackets, respectively; similar values were recorded at -15 degrees: 8.6, 8.1, 7.0, and 5.7 Nmm, respectively. The recorded differences of maximum moments were statistically significant, except between the Incognito and STb brackets. Additionally, the torque angles were evaluated at which the crown torque fell well below the minimum levels of 5.0 Nmm, as well as the moment/torque ratio at the last part of the activation/deactivation curve, between 10 and 15 degrees. The lowest torque expression was observed at the self-ligating lingual brackets, followed by the conventional brackets. The Incognito and STb lingual brackets generated the highest moments.
Resumo:
The aim of this study was to assess the effect of bracket type on the labiopalatal forces and moments generated in the sagittal plane. Incognito™ lingual brackets (3M Unitek), STb™ lingual brackets (Light Lingual System; ORMCO), and conventional 0.018 inch slot brackets (Gemini; 3M Unitek) were bonded on three identical maxillary acrylic resin models, with a palatally displaced right lateral incisor. The transfer trays for the indirect bonding of the lingual brackets were constructed in certified laboratories. Each model was mounted on the orthodontic measurement and simulation system and ten 0.013 inch CuNiTi wires were used for each bracket type. The wire was ligated with elastomerics and each measurement was repeated once after re-ligation. The labiopalatal forces and the moments in the sagittal plane were recorded on the right lateral incisor. One-way analysis of variance and post hoc Scheffe pairwise comparisons were used to assess the effect on bracket type on the generated forces and moments. The magnitude of forces ranged from 1.62, 1.27, and 1.81 N for the STb, conventional, and Incognito brackets, respectively; the corresponding moments were 2.01, 1.45, and 2.19 N mm, respectively. Bracket type was a significant predictor of the generated forces (P < 0.001) and moments (P < 0.001). The produced forces were different among all three bracket types, whereas the generated moments differed between conventional and lingual brackets but not between lingual brackets.
Resumo:
Protozoan parasites are one of the major causes of diseases worldwide. The vector transmitted parasites exhibit complex life cycles involving interactions between humans, protozoa, and arthropods. In order to adapt themselves to the changing microenvironments, they have to undergo complex morphological and metabolic changes. These changes can be brought about by expressing a new pool of proteins in the cell or by modifying the existing repertoire of proteins via posttranslational modifications (PTMs). PTMs involve covalent modification and processing of proteins thereby modulating their functions. Some of these changes may involve PTMs of parasite proteins to help the parasite survive within the host and the vector. Out of many PTMs known, three are unique since they occur only on single proteins: ethanolamine phosphoglycerol (EPG) glutamate, hypusine and diphthamide. These modifications occur on eukaryotic elongation factor 1A (eEF1A), eukaryotic initiation factor 5A (eIF5A) and eukaryotic elongation factor 2 (eEF2), respectively. Interestingly, the proteins carrying these unique modifications are all involved in the elongation steps of translation. Here we review these unique PTMs, which are well conserved in protozoan parasites, and discuss their roles in viability and pathogenesis of parasites. Characterization of these modifications and studying their roles in physiology as well as pathogenesis will provide new insights in parasite biology, which may also help in developing new therapeutic interventions.