40 resultados para Mean-value solution
Resumo:
Prolongation of the safe period of ischemia of the heart is an efficient way to overcome donor organ shortage, as demonstrated in renal and hepatic transplantation. We present the results of a prospective, randomized study comparing preservation with University of Wisconsin solution (UWS) versus St. Thomas' Hospital solution (STS) in clinical heart transplantation. A total of 39 patients were enrolled in the study (n = 20 for UWS and n = 19 for STS). Hemodynamic, electron microscopic, and biochemical evaluation did not reveal any significant differences in postoperative myocardial performance. Only the number of intraoperative defibrillations (0.82 for UWS versus 1.7 for STS) and the rhythm stability after reperfusion (13/20 UWS hearts versus 6/19 STS hearts in sinus rhythm) were significantly different. Heart preservation with UWS and STS appears to be of comparable efficacy at mean ischemic times of less than 4 hours.
Resumo:
PURPOSE: To determine how the ADC value of parotid glands is influenced by the choice of b-values. MATERIALS AND METHODS: In eight healthy volunteers, diffusion-weighted echo-planar imaging (DW-EPI) was performed on a 1.5 T system, with b-values (in seconds/mm2) of 0, 50, 100, 150, 200, 250, 300, 500, 750, and 1000. ADC values were calculated by two alternative methods (exponential vs. logarithmic fit) from five different sets of b-values: (A) all b-values; (B) b=0, 50, and 100; (C) b=0 and 750; (D) b=0, 500, and 1000; and (E) b=500, 750, and 1000. RESULTS: The mean ADC values for the different settings were (in 10(-3) mm2/second, exponential fit): (A) 0.732+/-0.019, (B) 2.074+/-0.084, (C) 0.947+/-0.020, (D) 0.890+/-0.023, and (E) 0.581+/-0.021. ADC values were significantly (P <0.001) different for all pairwise comparisons of settings (A-E) of b-values, except for A vs. D (P=0.172) and C vs. D (P=0.380). The ADC(B) was significantly higher than ADC(C) or ADC(D), which was significantly higher than ADC(E). ADC values from exponential vs. logarithmic fit (P=0.542), as well as left vs. right parotid gland (P=0.962), were indistinguishable. CONCLUSION: The ADC values calculated from low b-value settings were significantly higher than those calculated from high b-value settings. These results suggest that not only true diffusion but also perfusion and saliva flow may contribute to the ADC.
Resumo:
Objective Arterial lactate, base excess (BE), lactate clearance, and Sequential Organ Failure Assessment (SOFA) score have been shown to correlate with outcome in severely injured patients. The goal of the present study was to separately assess their predictive value in patients suffering from traumatic brain injury (TBI) as opposed to patients suffering from injuries not related to the brain. Materials and methods A total of 724 adult trauma patients with an Injury Severity Score (ISS) ≥ 16 were grouped into patients without TBI (non-TBI), patients with isolated TBI (isolated TBI), and patients with a combination of TBI and non-TBI injuries (combined injuries). The predictive value of the above parameters was then analyzed using both uni- and multivariate analyses. Results The mean age of the patients was 39 years (77 % males), with a mean ISS of 32 (range 16–75). Mortality ranged from 14 % (non-TBI) to 24 % (combined injuries). Admission and serial lactate/BE values were higher in non-survivors of all groups (all p < 0.01), but not in patients with isolated TBI. Admission SOFA scores were highest in non-survivors of all groups (p = 0.023); subsequently septic patients also showed elevated SOFA scores (p < 0.01), except those with isolated TBI. In this group, SOFA score was the only parameter which showed significant differences between survivors and non-survivors. Receiver operating characteristic (ROC) analysis revealed lactate to be the best overall predictor for increased mortality and further septic complications, irrespective of the leading injury. Conclusion Lactate showed the best performance in predicting sepsis or death in all trauma patients except those with isolated TBI, and the differences were greatest in patients with substantial bleeding. Following isolated TBI, SOFA score was the only parameter which could differentiate survivors from non-survivors on admission, although the SOFA score, too, was not an independent predictor of death following multivariate analysis.
Resumo:
Ecosystems are faced with high rates of species loss which has consequences for their functions and services. To assess the effects of plant species diversity on the nitrogen (N) cycle, we developed a model for monthly mean nitrate (NO3-N) concentrations in soil solution in 0-30 cm mineral soil depth using plant species and functional group richness and functional composition as drivers and assessing the effects of conversion of arable land to grassland, spatially heterogeneous soil properties, and climate. We used monthly mean NO3-N concentrations from 62 plots of a grassland plant diversity experiment from 2003 to 2006. Plant species richness (1-60) and functional group composition (1-4 functional groups: legumes, grasses, non-leguminous tall herbs, non-leguminous small herbs) were manipulated in a factorial design. Plant community composition, time since conversion from arable land to grassland, soil texture, and climate data (precipitation, soil moisture, air and soil temperature) were used to develop one general Bayesian multiple regression model for the 62 plots to allow an in-depth evaluation using the experimental design. The model simulated NO3-N concentrations with an overall Bayesian coefficient of determination of 0.48. The temporal course of NO3-N concentrations was simulated differently well for the individual plots with a maximum plot-specific Nash-Sutcliffe Efficiency of 0.57. The model shows that NO3-N concentrations decrease with species richness, but this relation reverses if more than approx. 25 % of legume species are included in the mixture. Presence of legumes increases and presence of grasses decreases NO3-N concentrations compared to mixtures containing only small and tall herbs. Altogether, our model shows that there is a strong influence of plant community composition on NO3-N concentrations.
Resumo:
RATIONALE In biomedical journals authors sometimes use the standard error of the mean (SEM) for data description, which has been called inappropriate or incorrect. OBJECTIVE To assess the frequency of incorrect use of SEM in articles in three selected cardiovascular journals. METHODS AND RESULTS All original journal articles published in 2012 in Cardiovascular Research, Circulation: Heart Failure and Circulation Research were assessed by two assessors for inappropriate use of SEM when providing descriptive information of empirical data. We also assessed whether the authors state in the methods section that the SEM will be used for data description. Of 441 articles included in this survey, 64% (282 articles) contained at least one instance of incorrect use of the SEM, with two journals having a prevalence above 70% and "Circulation: Heart Failure" having the lowest value (27%). In 81% of articles with incorrect use of SEM, the authors had explicitly stated that they use the SEM for data description and in 89% SEM bars were also used instead of 95% confidence intervals. Basic science studies had a 7.4-fold higher level of inappropriate SEM use (74%) than clinical studies (10%). LIMITATIONS The selection of the three cardiovascular journals was based on a subjective initial impression of observing inappropriate SEM use. The observed results are not representative for all cardiovascular journals. CONCLUSION In three selected cardiovascular journals we found a high level of inappropriate SEM use and explicit methods statements to use it for data description, especially in basic science studies. To improve on this situation, these and other journals should provide clear instructions to authors on how to report descriptive information of empirical data.
Resumo:
Alveolar echinococcosis (AE), caused by larva stage of Echinococcus multilocularis, is one of the lethal parasitic diseases of man and a major public health problem in many countries in the northern hemisphere. When the living conditions and habits in Turkey were considered in terms of relation with the life cycle of the parasite, it was suggested that AE has been much more common than reported mainly from the Eastern Anatolia region of Turkey. Since in vitro serologic diagnosis tests with high specificity for AE have not been used in our country, most of the cases with liver lesions were misdiagnosed by radiological investigations as malignancies. The aim of this study was to evaluate the diagnostic value of the in-house ELISA methods developed by using three different antigens (EgHF, Em2, EmII/3-10) in the serological diagnosis of AE. The study samples included a total of 100 sera provided by Bern University Parasitology Institute where samples were obtained from patients with helminthiasis and all were confirmed by clinical, parasitological and/or histopathological means. Ten samples from each of the cases infected by E.multilocularis, E.granulosus, Taenia solium, Wuchereria bancrofti, Strongyloides stercolaris, Ascaris lumbricoides, Toxocara canis, Trichinella spiralis, Fasciola hepatica and Schistosoma haematobium were studied. In the study, EgHF (E.granulosus hydatid fluid) antigens were prepared in our laboratory from the liver cyst fluids of sheeps with cystic echinococcosis, however Em2 (E.multilocularis metacestode-purified laminated layer) and EmII/3-10 (E.multilocularis recombinant protoscolex tegument) antigens were provided by Bern University Parasitology Institute. Flat bottom ELISA plates were covered with EgHF, Em2 and EmII/3-10 antigens in the concentrations of 2.5 µg, 1 µg and 0.18 µg per well, respectively, and all sera were tested by EgHF-ELISA, Em2-ELISA and EmII/3-10-ELISA methods. For each tests, the samples which were reactive above the cut-off value (mean OD of negative controls+2 SD) were accepted as positive. The sensitivity of the ELISA tests performed with EgHF, Em2 and Em2II/3-10 antigens were estimated as 100%, 90% and 90%, respectively, whereas the specificity were 63%, 91% and 91%, respectively. When Em2-ELISA and EmII/3-10-ELISA tests were evaluated together, the specificity increased to 96%. Our data indicated that the highest sensitivity (100% with EgHF-ELISA) and specificity (96% with Em2-ELISA + EmII/3-10-ELISA) for the serodiagnosis of AE can be achieved by the combined use of the ELISA tests with three different antigens. It was concluded that the early and accurate diagnosis of AE in our country which is endemic for that disease, could be supported by the use of highly specific serological tests such as Em2-ELISA ve EmII/3-10-ELISA contributing radiological data.
Resumo:
BACKGROUND Acute mesenteric ischemia (AMI) is an emergency with a mortality rate up to 50 %. Detecting AMI continues to be a major challenge. This study assed the correlation of repeated preoperative serum lactate with bowel necrosis and to identify risk factors for a lethal outcome in patients with AMI. METHODS A retrospective study of 91 patients with clinically and pathologically confirmed AMI from January 2006 to December 2012 was performed. RESULTS In-hospital mortality rate was 42.9 %. Two hundred nine preoperative lactate measurements were analyzed (2.3 ± 1.1 values per patient). Less than or equal to six hours prior to surgery, the mean serum lactate level was significantly higher (4.97 ± 4.21 vs. 3.24 ± 3.05 mmol/L, p = 0.006) and the mean pH significantly lower (7.28 ± 0.12 vs. 7.37 ± 0.08, p = 0.001) compared to >6 h before surgery. Thirty-four patients had at least two lactate measurements within 24 h prior to surgery. In this subgroup, 17 patients (50 %) exhibited an increase, 17 patients (50 %) a decrease in lactate levels. Forward logistic regression analysis showed that length of necrotic bowel and the highest lactate value 24 h prior to surgery were independent risk factors for mortality (r (2) = 0.329). CONCLUSION The value of serial lactate and pH measurements to predict the length of necrotic bowel is very limited. Length of necrotic bowel and lactate values are independent risk factors for mortality.
Resumo:
In this chapter a low-cost surgical navigation solution for periacetabular osteotomy (PAO) surgery is described. Two commercial inertial measurement units (IMU, Xsens Technologies, The Netherlands), are attached to a patient’s pelvis and to the acetabular fragment, respectively. Registration of the patient with a pre-operatively acquired computer model is done by recording the orientation of the patient’s anterior pelvic plane (APP) using one IMU. A custom-designed device is used to record the orientation of the APP in the reference coordinate system of the IMU. After registration, the two sensors are mounted to the patient’s pelvis and acetabular fragment, respectively. Once the initial position is recorded, the orientation is measured and displayed on a computer screen. A patient-specific computer model generated from a pre-operatively acquired computed tomography (CT) scan is used to visualize the updated orientation of the acetabular fragment. Experiments with plastic bones (7 hip joints) performed in an operating room comparing a previously developed optical navigation system with our inertial-based navigation system showed no statistical difference on the measurement of acetabular component reorientation (anteversion and inclination). In six out of seven hip joints the mean absolute difference was below five degrees for both anteversion and inclination.
Resumo:
AIM To evaluate the diagnostic value (sensitivity, specificity) of positron emission mammography (PEM) in a single site non-interventional study using the maximum PEM uptake value (PUVmax). PATIENTS, METHODS In a singlesite, non-interventional study, 108 patients (107 women, 1 man) with a total of 151 suspected lesions were scanned with a PEM Flex Solo II (Naviscan) at 90 min p.i. with 3.5 MBq 18F-FDG per kg of body weight. In this ROI(region of interest)-based analysis, maximum PEM uptake value (PUV) was determined in lesions, tumours (PUVmaxtumour), benign lesions (PUVmaxnormal breast) and also in healthy tissues on the contralateral side (PUVmaxcontralateral breast). These values were compared and contrasted. In addition, the ratios of PUVmaxtumour / PUVmaxcontralateral breast and PUVmaxnormal breast / PUVmaxcontralateral breast were compared. The image data were interpreted independently by two experienced nuclear medicine physicians and compared with histology in cases of suspected carcinoma. RESULTS Based on a criteria of PUV>1.9, 31 out of 151 lesions in the patient cohort were found to be malignant (21%). A mean PUVmaxtumour of 3.78 ± 2.47 was identified in malignant tumours, while a mean PUVmaxnormal breast of 1.17 ± 0.37 was reported in the glandular tissue of the healthy breast, with the difference being statistically significant (p < 0.001). Similarly, the mean ratio between tumour and healthy glandular tissue in breast cancer patients (3.15 ± 1.58) was found to be significantly higher than the ratio for benign lesions (1.17 ± 0.41, p < 0.001). CONCLUSION PEM is capable of differentiating breast tumours from benign lesions with 100% sensitivity along with a high specificity of 96%, when a threshold of PUVmax >1.9 is applied.
Resumo:
PURPOSE To evaluate a low-cost, inertial sensor-based surgical navigation solution for periacetabular osteotomy (PAO) surgery without the line-of-sight impediment. METHODS Two commercial inertial measurement units (IMU, Xsens Technologies, The Netherlands), are attached to a patient's pelvis and to the acetabular fragment, respectively. Registration of the patient with a pre-operatively acquired computer model is done by recording the orientation of the patient's anterior pelvic plane (APP) using one IMU. A custom-designed device is used to record the orientation of the APP in the reference coordinate system of the IMU. After registration, the two sensors are mounted to the patient's pelvis and acetabular fragment, respectively. Once the initial position is recorded, the orientation is measured and displayed on a computer screen. A patient-specific computer model generated from a pre-operatively acquired computed tomography scan is used to visualize the updated orientation of the acetabular fragment. RESULTS Experiments with plastic bones (eight hip joints) performed in an operating room comparing a previously developed optical navigation system with our inertial-based navigation system showed no statistically significant difference on the measurement of acetabular component reorientation. In all eight hip joints the mean absolute difference was below four degrees. CONCLUSION Using two commercially available inertial measurement units we show that it is possible to accurately measure the orientation (inclination and anteversion) of the acetabular fragment during PAO surgery and therefore to successfully eliminate the line-of-sight impediment that optical navigation systems have.