44 resultados para Maxillofacial, Prosthesis.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The surgical treatment of oral cancer results in functional and aesthetical impairments. Patients' quality of life is considerably impaired by oral symptoms resulting from therapy of oral cancer. In many cases the inevitable resection of the tumor, as well as the adjuvant radiochemotherapy will cause the destruction of physiologically and anatomically important structures. One focus of research was the specific rehabilitation of dental loss by functional dentures. Another was the course of 19 impairments (comprehension of speech for unknown others, comprehension of speech for familiar others, eating/swallowing, mobility of the tongue, opening range of the mouth, mobility of lower jaw, mobility of neck, mobility of arms and shoulders, sense of taste, sense of smell, appearance, strength, appetite, respiration, pain, swelling, xerostomia, halitosis). METHODS: Commissioned by the German, Austrian and Swiss cooperative group on tumors of the maxillofacial region (DOSAK), data were collected in 3.894 questionnaires at 43 hospitals in Germany, Austria and Switzerland. The catalogue comprised 147 items in 9 chapters. At the end of the enquiry, 1.761 anonymous questionnaires were returned by 38 hospitals. 1.652 of these could be evaluated regarding the question. RESULTS: The sum score of the 19 impairments was highly increased immediately after the operation and recovered over the next 6 months, without, however, reaching the pre-surgery level. Of 1.652 patients, only 35% did not lose any teeth during therapy. 23% lost up to 5, 17% up to 10 teeth. A quarter of the patients lost more than 10 teeth. The more teeth were lost, the greater the decline of quality of life (p < or = 0.001), although this could be allayed by the functionality of the dentures (p < or = 0.001). There is a reciprocal dependence between the functionality of dental prosthetics and impairment by eating/swallowing (p < or = 0.001). CONCLUSIONS: Patients' quality of life after radical surgery of a carcinoma of the oral cavity depends not only on the functionality of dentures and the specificity of rehabilitation, but also from the initial findings, the extent and location of the resection, the chosen therapy, the general circumstances of the patient's life as well as their strategies of coping. These factors, however, unlike those of functionality of dental prosthesis and rehabilitation, are not modifiable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: The aim of this study was to analyse the character of assault-related facial fractures in central Switzerland and to compare their prevalence with the data presented in similar reports from other countries. MATERIAL: The present study comprised 65 patients with assault-related maxillofacial fractures treated in the Department of Cranio-Maxillofacial Surgery, University Hospital of Bern between 2000 and 2002. METHODS: The mechanism, the causes of the injuries and the location of the fractures were analysed by reviewing emergency and hospital records. Concomitant injuries were also studied. RESULTS: The mean age of the patients was 33 years with the largest group being below 25 years. The male-to-female ratio was 56:9. The most common causes of assault-related injuries were fights, most frequently facial blows, accounting for 92.5% of all patients. Seventy-six per cent of the fractures occurred in the middle and upper facial skeleton with a predominance of 2:1 for the left side. In 39 patients (60%) surgery was necessary, with a mean hospital stay of 3.3 days. Thirty-five patients (54%) had concomitant injuries. Alcohol and drug abuse was found in 15 patients (23%). CONCLUSION: It seems that mostly young men suffer assault-related maxillofacial injuries. A contributing factor to the increased disposition for violence could be alcohol and drug abuse. Therefore, national prevention programmes for alcohol or drug abuse and addiction might have a positive effect on reducing the incidence of assault-related maxillofacial injuries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The inevitable detachment of tendons and the loss of the forefoot in Chopart and Lisfranc amputations result in equinus and varus of the residual foot. In an insensate foot these deformities can lead to keratotic lesions and ulcerations. The currently available prostheses cannot safely counteract the deforming forces and the resulting complications. METHODS: A new below-knee prosthesis was developed, combining a soft socket with a rigid shaft. The mold is taken with the foot in the corrected position. After manufacturing the shaft, the lateral third of the circumference of the shaft is cut away and reattached distally with a hinge, creating a lateral flap. By closing this flap the hindfoot is gently levered from the varus position into valgus. Ten patients (seven amputations at the Chopart-level, three amputations at the Lisfranc-level) with insensate feet were fitted with this prosthesis at an average of 3 (range 1.5 to 9) months after amputation. The handling, comfort, time of daily use, mobility, correction of malposition and complications were recorded to the latest followup (average 31 months, range 24 to 37 months after amputation). RESULTS: Eight patients evaluated the handling as easy, two as difficult. No patient felt discomfort in the prosthesis. The average time of daily use was 12 hours, and all patients were able to walk. All varus deformities were corrected in the prosthesis. Sagittal alignment was kept neutral. Complications were two minor skin lesions and one small ulcer, all of which responded to conservative treatment, and one ulcer healed after debridement and lengthening of the Achilles tendon. CONCLUSIONS: The "flap-shaft" prosthesis is a valuable option for primary or secondary prosthetic fitting of Chopart-level and Lisfranc-level amputees with insensate feet and flexible equinus and varus deformity at risk for recurrent ulceration. It provided safe and sufficient correction of malpositions and enabled the patients to walk as much as their general condition permitted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Recently recommended treatment modalities for prosthetic joint infection (PJI) were evaluated. METHODS: A retrospective cohort analysis of 68 patients with PJI of hip or knee who were treated from 1995 through 2004 was conducted at the University Hospital Bern (Bern, Switzerland). RESULTS: A 2-stage exchange was the most frequent (75.0%) surgical strategy, followed by retention and debridement (17.6%), 1-stage exchange (5.9%), and resection arthroplasty or suppressive antimicrobial treatment (1.5%). The chosen strategy was in 88% agreement with the recommendations. Adherence was only 17% for retention and debridement and was 0% for 1-stage exchange. Most PJIs (84%) were treated with an adequate or partially adequate antimicrobial regimen. Recurrence-free survival was observed in 51.5% of PJI episodes after 24 months of follow-up. The risk of treatment failure was significantly higher for PJI treated with a surgical strategy other than that recommended (hazard ratio, 2.34; 95% confidence interval, 1.10-4.70; P = .01) and for PJIs treated with antibiotics not corresponding to recommendations (hazard ratio, 3.45; confidence interval, 1.50-7.60; P = .002). Other risk factors associated with lack of healing were a high infection score at the time of diagnosis (hazard ratio, 1.29; 95% confidence interval, 1.10-1.40; P < .001) and presence of a sinus tract (hazard ratio, 2.35; 95% confidence interval, 1.10-5.0; P = .02). CONCLUSIONS: Our study demonstrates the value of current treatment recommendations. Inappropriate choice of conservative surgical strategies (such as debridement and retention) and inadequate antibiotic treatment are associated with failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: We sought to determine both the procedural performance and safety of percutaneous implantation of the second (21-French [F])- and third (18-F)-generation CoreValve aortic valve prosthesis (CoreValve Inc., Irvine, California). BACKGROUND: Percutaneous aortic valve replacement represents an emerging alternative therapy for high-risk and inoperable patients with severe symptomatic aortic valve stenosis. METHODS: Patients with: 1) symptomatic, severe aortic valve stenosis (area <1 cm2); 2) age > or =80 years with a logistic EuroSCORE > or =20% (21-F group) or age > or =75 years with a logistic EuroSCORE > or =15% (18-F group); or 3) age > or =65 years plus additional prespecified risk factors were included. Introduction of the 18-F device enabled the transition from a multidisciplinary approach involving general anesthesia, surgical cut-down, and cardiopulmonary bypass to a truly percutaneous approach under local anesthesia without hemodynamic support. RESULTS: A total of 86 patients (21-F, n = 50; 18-F, n = 36) with a mean valve area of 0.66 +/- 0.19 cm2 (21-F) and 0.54 +/- 0.15 cm2 (18-F), a mean age of 81.3 +/- 5.2 years (21-F) and 83.4 +/- 6.7 years (18-F), and a mean logistic EuroSCORE of 23.4 +/- 13.5% (21-F) and 19.1 +/- 11.1% (18-F) were recruited. Acute device success was 88%. Successful device implantation resulted in a marked reduction of aortic transvalvular gradients (mean pre 43.7 mm Hg vs. post 9.0 mm Hg, p < 0.001) with aortic regurgitation grade remaining unchanged. Acute procedural success rate was 74% (21-F: 78%; 18-F: 69%). Procedural mortality was 6%. Overall 30-day mortality rate was 12%; the combined rate of death, stroke, and myocardial infarction was 22%. CONCLUSIONS: Treatment of severe aortic valve stenosis in high-risk patients with percutaneous implantation of the CoreValve prosthesis is feasible and associated with a lower mortality rate than predicted by risk algorithms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The literature shows that hardware removal rates after the fixation of maxillofacial fractures with miniplates are not insignificant. The aim of the present survey was to clarify the policies of Finnish oral and maxillofacial consultants for the removal of titanium miniplates after the treatment of facial fractures in adults. Additional aims were to clarify the factors influencing plate removal policy in general, and the reasons for routine plate removal in particular. MATERIALS AND METHODS: Twenty-six consultant oral and maxillofacial surgeons responded to a questionnaire about miniplate removal policy after treating 5 types of simple, noncomminuted fractures. RESULTS: Overall, routine plate removal was uncommon. However, 12 consultants (46.2%) routinely removed the plate after treating mandibular angle fractures, and simultaneously extracted the third molar because of an increased risk of infection. Most respondents (88.5%) stated that clinical experience guided their plate-removal policy. A policy of routine plate removal was most infrequent among the consultants who had the most experience. CONCLUSIONS: The literature provides no definitive answer to the question of whether routine removal of miniplates could or should be indicated, and in what situations. Considering the fairly significant frequency of plate-related complications in general and infection-related complications in particular, long-term follow-up after treatment is indicated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To systematically appraise the impact of mechanical/technical risk factors on implant-supported reconstructions. MATERIAL AND METHODS: A MEDLINE (PubMed) database search from 1966 to April 2008 was conducted. The search strategy was a combination of MeSH terms and the key words: design, dental implant(s), risk, prosthodontics, fixed prosthodontics, fixed partial denture(s), fixed dental prosthesis (FDP), fixed reconstruction(s), oral rehabilitation, bridge(s), removable partial denture(s), overdenture(s). Randomized controlled trials, controlled trials, and prospective and retrospective cohort studies with a mean follow-up of at least 4 years were included. The material evaluated in each study had to include cases with/without exposure to the risk factor. RESULTS: From 3,568 articles, 111 were selected for full text analysis. Of the 111 articles, 33 were included for data extraction after grouping the outcomes into 10 risk factors: type of retentive elements supporting overdentures, presence of cantilever extension(s), cemented versus screw-retained FDPs, angled/angulated abutments, bruxism, crown/implant ratio, length of the suprastructure, prosthetic materials, number of implants supporting an FDP, and history of mechanical/technical complications. CONCLUSIONS: The absence of a metal framework in overdentures, the presence of cantilever extension(s) > 15 mm and of bruxism, the length of the reconstruction, and a history of repeated complications were associated with increased mechanical/technical complications. The type of retention, the presence of angled abutments, the crown-implant ratio, and the number of implants supporting an FDP were not associated with increased mechanical/technical complications. None of the mechanical/technical risk factors had an impact on implant survival and success rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To evaluate prosthetic parameters in the edentulous anterior maxilla for decision making between fixed and removable implant prosthesis using virtual planning software. MATERIAL AND METHODS CT- or DVT-scans of 43 patients (mean age 62 ± 8 years) with an edentulous maxilla were analyzed with the NobelGuide software. Implants (≥3.5 mm diameter, ≥10 mm length) were virtually placed in the optimal three-dimensional prosthetic position of all maxillary front teeth. Anatomical and prosthetic landmarks, including the cervical crown point (C-Point), the acrylic flange border (F-Point), and the implant-platform buccal-end (I-Point) were defined in each middle section to determine four measuring parameters: (1) acrylic flange height (FLHeight), (2) mucosal coverage (MucCov), (3) crown-Implant distance (CID) and (4) buccal prosthesis profile (ProsthProfile). Based on these parameters, all patients were assigned to one of three classes: (A) MucCov ≤ 0 mm and ProsthProfile≥45(0) allowing for fixed prosthesis, (B) MucCov = 0-5 mm and/or ProsthProfile = 30(0) -45(0) probably allowing for fixed prosthesis, and (C) MucCov ≥ 5 mm and/or ProsthProfile ≤ 30(0) where removable prosthesis is favorable. Statistical analyses included descriptive methods and non-parametric tests. RESULTS Mean values were for FLHeight 10.0 mm, MucCov 5.6 mm, CID 7.4 mm, and ProsthProfile 39.1(0) . Seventy percent of patients fulfilled class C criteria (removable), 21% class B (probably fixed), and 2% class A (fixed), while in 7% (three patients) bone volume was insufficient for implant planning. CONCLUSIONS The proposed classification and virtual planning procedure simplify the decision-making process regarding type of prosthesis and increase predictability of esthetic treatment outcomes. It was demonstrated that in the majority of cases, the space between the prosthetic crown and implant platform had to be filled with prosthetic materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Periprosthetic infections remain a devastating problem in the field of joint arthroplasty. In the following study, the results of a two-stage treatment protocol for chronic periprosthetic infections using an intraoperatively molded cement prosthesis-like spacer (CPLS) are presented. METHODS Seventy-five patients with chronically infected knee prosthesis received a two-stage revision procedure with the newly developed CPLS between June 2006 and June 2011. Based on the microorganism involved, patients were grouped into either easy to treat (ETT) or difficult to treat (DTT) and treated accordingly. Range of motion (ROM) and the knee society score (KSS) were utilized for functional assessment. RESULTS Mean duration of the CPLS implant in the DTT group was 3.6 months (range 3-5 months) and in the ETT group 1.3 months (range 0.7-2.5 months). Reinfection rates of the final prosthesis were 9.6% in the ETT and 8.3% in the DTT group with no significant difference between both groups regarding ROM or KSS (P = 0.87, 0.64, resp.). CONCLUSION The results show that ETT patients do not necessitate the same treatment protocol as DTT patients to achieve the same goal, emphasizing the need to differentiate between therapeutic regimes. We also highlight the feasibility of CLPS in two-stage protocols.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives The aim of this study was to quantify potential differences in count, frequency and pattern of high-intensity transient signals (HITS) during transapical transcatheter aortic valve implantation (TA-TAVI), by comparing the Symetis Acurate TA (SA) with the balloon-expandable Edwards Sapien XT (ES) system. Background Recently, the Symetis Acurate TA revalving system has been introduced for TA-TAVI. The Symetis Acurate TA aortic bioprosthesis is self-expanding and is deployed by a specific two-step implantation technique. Whether this novel method increases the load of intraprocedural emboli, detected by transcranial Doppler ultrasound (TCD) as HITS, or not is not clear. Methods Twenty-two patients (n = 11 in each study arm, median logistic EuroScore 20%, median STS score 7%) displayed continuous TCD signals of good quality throughout the entire TA-TAVI procedure and were included in the final analysis. Data are presented as median with interquartile ranges. Results No significant differences were detected in total procedural or interval-related HITS load (SA: 303 [200; 594], ES: 499 [285; 941]; p = 0.16). With both devices, HITS peaked during prosthesis deployment (PD), whereas significantly fewer HITS occurred during instrumentation (SA: p = 0.002; ES: <0.001) or post-implantation PI (SA: p = 0.007; ES: <0.001). PD-associated HITS amounted to almost half of the total HITS load. One patient suffered new disabling stroke at 30 days. Thirty-day mortality amounted to 13.6% (3 of 22 patients). Conclusions Simplified transapical delivery using the self-expanding SA device does not increase HITS, despite of a two-step deployment technique with more interactions with the native aortic valve, when compared to the balloon-expandable ES valve. The similarity in HITS count, frequency and pattern with the two systems suggests a common mechanism for the release of cerebral microemboli.