84 resultados para Mahoney Park (Kenilworth, Ill.)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article is a systematic review of whether everyday exposure to radiofrequency electromagnetic field (RF-EMF) causes symptoms, and whether some individuals are able to detect low-level RF-EMF (below the ICNIRP [International Commission on Non-Ionizing Radiation Protection] guidelines). Peer-reviewed articles published before August 2007 were identified by means of a systematic literature search. Meta-analytic techniques were used to pool the results from studies investigating the ability to discriminate active from sham RF-EMF exposure. RF-EMF discrimination was investigated in seven studies including a total of 182 self-declared electromagnetic hypersensitive (EHS) individuals and 332 non-EHS individuals. The pooled correct field detection rate was 4.2% better than expected by chance (95% CI: -2.1 to 10.5). There was no evidence that EHS individuals could detect presence or absence of RF-EMF better than other persons. There was little evidence that short-term exposure to a mobile phone or base station causes symptoms based on the results of eight randomized trials investigating 194 EHS and 346 non-EHS individuals in a laboratory. Some of the trials provided evidence for the occurrence of nocebo effects. In population based studies an association between symptoms and exposure to RF-EMF in the everyday environment was repeatedly observed. This review showed that the large majority of individuals who claims to be able to detect low level RF-EMF are not able to do so under double-blind conditions. If such individuals exist, they represent a small minority and have not been identified yet. The available observational studies do not allow differentiating between biophysical from EMF and nocebo effects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Indications for the most frequently used imaging modalities in implant dentistry are proposed based on clinical need and biologic risk for the patient. To calculate the biologic risk, the authors carried out dose measurements. They demonstrated that the risk from a periapical radiograph is 20% of that from a panoramic radiograph. A panoramic radiograph and a series of 4 conventional tomographs of a single-tooth gap in the molar region carry 5% and 13% of the risk from computed tomography of the maxilla, respectively. Panoramic radiography is considered the standard radiographic examination for treatment planning of implant patients, because it imparts a low dose while giving the best radiographic survey. Periapical radiographs are used to elucidate details or to complete the findings obtained from the panoramic radiograph. Other radiographic methods, such as conventional film tomography or computed tomography, are applied only in special circumstances, film tomography being preferred for smaller regions of interest and computed tomography being justified for the complete maxilla or mandible when methods for dose reduction are followed. During follow-up, intraoral radiography is considered the standard radiographic examination, particularly for implants in the anterior region of the maxilla or for scientific studies. In patients requiring more than 5 periapical images, panoramic radiography is preferred.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the Tajik National Park (TNP) - a high-altitude area of nearly 26,000 km2 in Central Asia - past and present human activities visibly contrast with standard conservation requirements for protected areas worldwide. This paper focuses on resource management, and highlights three major processes that threaten both the sustainable use of natural resources and the preservation of nature per se: (i) intensified use of biomass as a fuel resource, (ii) inappropriate pasture management, and (iii) increased pressure on endangered wildlife. From analysis of these processes - their historical background, root causes, trends and interrelationships - options and needs to improve park management are proposed and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Two noninvasive methods to measure dental implant stability are damping capacity assessment (Periotest) and resonance frequency analysis (Osstell). The objective of the present study was to assess the correlation of these 2 techniques in clinical use. MATERIALS AND METHODS: Implant stability of 213 clinically stable loaded and unloaded 1-stage implants in 65 patients was measured in triplicate by means of resonance frequency analysis and Periotest. Descriptive statistics as well as Pearson's, Spearman's, and intraclass correlation coefficients were calculated with SPSS 11.0.2. RESULTS: The mean values were 57.66 +/- 8.19 implant stability quotient for the resonance frequency analysis and -5.08 +/- 2.02 for the Periotest. The correlation of both measuring techniques was -0.64 (Pearson) and -0.65 (Spearman). The single-measure intraclass correlation coefficients for the ISQ and Periotest values were 0.99 and 0.88, respectively (95% CI). No significant correlation of implant length with either resonance frequency analysis or Periotest could be found. However, a significant correlation of implant diameter with both techniques was found (P < .005). The correlation of both measuring systems is moderate to good. It seems that the Periotest is more susceptible to clinical measurement variables than the Osstell device. The intraclass correlation indicated lower measurement precision for the Periotest technique. Additionally, the Periotest values differed more from the normal (Gaussian) curve of distribution than the ISQs. Both measurement techniques show a significant correlation to the implant diameter. CONCLUSION: Resonance frequency analysis appeared to be the more precise technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Resonance frequency analysis (RFA) is a method of measuring implant stability. However, little is known about RFA of implants with long loading periods. The objective of the present study was to determine standard implant stability quotients (ISQs) for clinical successfully osseointegrated 1-stage implants in the edentulous mandible. MATERIALS AND METHODS: Stability measurements by means of RFA were performed in regularly followed patients who had received 1- stage implants for overdenture support. The time interval between implant placement and measurement ranged from 1 year up to 10 years. The short-term group comprised patients who were followed up to 5 years, while the long-term group included patients with an observation time of > 5 years up to 10 years. For further comparison RFA measurements were performed in a matching group with unloaded implants at the end of the surgical procedure. For statistical analysis various parameters that might influence the ISQs of loaded implants were included, and a mixed-effects model applied (regression analysis, P <.0125). RESULTS: Ninety-four patients were available with a total of 205 loaded implants, and 16 patients with 36 implants immediately after the surgical procedure. The mean ISQ of all measured implants was 64.5 +/- 7.9 (range, 58 to 72). Statistical analysis did not reveal significant differences in the mean ISQ related to the observation time. The parameters with overall statistical significance were the diameter of the implants and changes in the attachment level. In the short-term group, the gender and the clinically measured attachment level had a significant effect. Implant diameter had a significant effect in the long-term group. CONCLUSIONS: A mean ISQ of 64.5 +/- 7.9 was found to be representative for stable asymptomatic interforaminal implants measured by the RFA instrument at any given time point. No significant differences in ISQ values were found between implants with different postsurgical time intervals. Implant diameter appears to influence the ISQ of interforaminal implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This retrospective study analyzed the pool of patients referred for treatment with dental implants over a 3-year period in a referral specialty clinic. Materials and Methods: All patients receiving dental implants between 2002 and 2004 in the Department of Oral Surgery and Stomatology, University of Bern, were included in this retrospective study. Patients were analyzed according to age, gender, indications for implant therapy, location of implants, and type and length of implants placed. A cumulative logistic regression analysis was performed to identify and analyze potential risk factors for complications or failures. Results: A total of 1,206 patients received 1,817 dental implants. The group comprised 573 men and 633 women with a mean age of 55.2 years. Almost 60% of patients were age 50 or older. The most frequent indication for implant therapy was single-tooth replacement in the maxilla (522 implants or 28.7%). A total of 726 implants (40%) were inserted in the esthetically demanding region of the anterior maxilla. For 939 implants (51.7%), additional bone-augmentation procedures were required. Of these, ridge augmentation with guided bone regeneration was performed more frequently than sinus grafting. Thirteen complications leading to early failures were recorded, resulting in an early failure rate of 0.7%. The regression analysis failed to identify statistically significant failure etiologies for the variables assessed. Conclusions: From this study it can be concluded that patients referred to a specialty clinic for implant placement were more likely to be partially edentulous and over 50 years old. Single-tooth replacement was the most frequent indication (> 50%). Similarly, additional bone augmentation was indicated in more than 50% of cases. Adhering to strict patient selection criteria and a standardized surgical protocol, an early failure rate of 0.7% was experienced in this study population

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Sedative and analgesic drugs are frequently used in critically ill patients. Their overuse may prolong mechanical ventilation and length of stay in the intensive care unit. Guidelines recommend use of sedation protocols that include sedation scores and trials of sedation cessation to minimize drug use. We evaluated processed electroencephalography (response and state entropy and bispectral index) as an adjunct to monitoring effects of commonly used sedative and analgesic drugs and intratracheal suctioning. METHODS: Electrodes for monitoring bispectral index and entropy were placed on the foreheads of 44 critically ill patients requiring mechanical ventilation and who previously had no brain dysfunction. Sedation was targeted individually using the Ramsay Sedation Scale, recorded every 2 hours or more frequently. Use of and indications for sedative and analgesic drugs and intratracheal suctioning were recorded manually and using a camera. At the end of the study, processed electroencephalographical and haemodynamic variables collected before and after each drug application and tracheal suctioning were analyzed. Ramsay score was used for comparison with processed electroencephalography when assessed within 15 minutes of an intervention. RESULTS: The indications for boli of sedative drugs exhibited statistically significant, albeit clinically irrelevant, differences in terms of their association with processed electroencephalographical parameters. Electroencephalographical variables decreased significantly after bolus, but a specific pattern in electroencephalographical variables before drug administration was not identified. The same was true for opiate administration. At both 30 minutes and 2 minutes before intratracheal suctioning, there was no difference in electroencephalographical or clinical signs in patients who had or had not received drugs 10 minutes before suctioning. Among patients who received drugs, electroencephalographical parameters returned to baseline more rapidly. In those cases in which Ramsay score was assessed before the event, processed electroencephalography exhibited high variation. CONCLUSIONS: Unpleasant or painful stimuli and sedative and analgesic drugs are associated with significant changes in processed electroencephalographical parameters. However, clinical indications for drug administration were not reflected by these electroencephalographical parameters, and barely by sedation level before drug administration or tracheal suction. This precludes incorporation of entropy and bispectral index as target variables for sedation and analgesia protocols in critically ill patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Neurally adjusted ventilatory assist (NAVA) delivers assist in proportion to the patient's respiratory drive as reflected by the diaphragm electrical activity (EAdi). We examined to what extent NAVA can unload inspiratory muscles, and whether unloading is sustainable when implementing a NAVA level identified as adequate (NAVAal) during a titration procedure. METHODS: Fifteen adult, critically ill patients with a Pao(2)/fraction of inspired oxygen (Fio(2)) ratio < 300 mm Hg were studied. NAVAal was identified based on the change from a steep increase to a less steep increase in airway pressure (Paw) and tidal volume (Vt) in response to systematically increasing the NAVA level from low (NAVAlow) to high (NAVAhigh). NAVAal was implemented for 3 h. RESULTS: At NAVAal, the median esophageal pressure time product (PTPes) and EAdi values were reduced by 47% of NAVAlow (quartiles, 16 to 69% of NAVAlow) and 18% of NAVAlow (quartiles, 15 to 26% of NAVAlow), respectively. At NAVAhigh, PTPes and EAdi values were reduced by 74% of NAVAlow (quartiles, 56 to 86% of NAVAlow) and 36% of NAVAlow (quartiles, 21 to 51% of NAVAlow; p < or = 0.005 for all). Parameters during 3 h on NAVAal were not different from parameters during titration at NAVAal, and were as follows: Vt, 5.9 mL/kg predicted body weight (PBW) [quartiles, 5.4 to 7.2 mL/kg PBW]; respiratory rate (RR), 29 breaths/min (quartiles, 22 to 33 breaths/min); mean inspiratory Paw, 16 cm H(2)O (quartiles, 13 to 20 cm H(2)O); PTPes, 45% of NAVAlow (quartiles, 28 to 57% of NAVAlow); and EAdi, 76% of NAVAlow (quartiles, 63 to 89% of NAVAlow). Pao(2)/Fio(2) ratio, Paco(2), and cardiac performance during NAVAal were unchanged, while Paw and Vt were lower, and RR was higher when compared to conventional ventilation before implementing NAVAal. CONCLUSIONS: Systematically increasing the NAVA level reduces respiratory drive, unloads respiratory muscles, and offers a method to determine an assist level that results in sustained unloading, low Vt, and stable cardiopulmonary function when implemented for 3 h.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The paucity of data on resource use in critically ill patients with hematological malignancy and on these patients' perceived poor outcome can lead to uncertainty over the extent to which intensive care treatment is appropriate. The aim of the present study was to assess the amount of intensive care resources needed for, and the effect of treatment of, hemato-oncological patients in the intensive care unit (ICU) in comparison with a nononcological patient population with a similar degree of organ dysfunction. METHODS: A retrospective cohort study of 101 ICU admissions of 84 consecutive hemato-oncological patients and 3,808 ICU admissions of 3,478 nononcological patients over a period of 4 years was performed. RESULTS: As assessed by Therapeutic Intervention Scoring System points, resource use was higher in hemato-oncological patients than in nononcological patients (median (interquartile range), 214 (102 to 642) versus 95 (54 to 224), P < 0.0001). Severity of disease at ICU admission was a less important predictor of ICU resource use than necessity for specific treatment modalities. Hemato-oncological patients and nononcological patients with similar admission Simplified Acute Physiology Score scores had the same ICU mortality. In hemato-oncological patients, improvement of organ function within the first 48 hours of the ICU stay was the best predictor of 28-day survival. CONCLUSION: The presence of a hemato-oncological disease per se is associated with higher ICU resource use, but not with increased mortality. If withdrawal of treatment is considered, this decision should not be based on admission parameters but rather on the evolutional changes in organ dysfunctions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Treatment of central and paracentral pulmonary embolism in patients with hemodynamic compromise remains a subject of debate, and no consensus exists regarding the best method: thrombolytic agents, catheter-based thrombus aspiration or fragmentation, or surgical embolectomy. We reviewed our experience with emergency surgical pulmonary embolectomy. METHODS: Between January of 2000 and March of 2007, 25 patients (17 male, mean age 60 years) underwent emergency open embolectomy for central and paracentral pulmonary embolism. Eighteen patients presented in cardiogenic shock, 8 of whom had cardiac arrest and required cardiopulmonary resuscitation. All patients underwent operation with mild hypothermic cardiopulmonary bypass. Concomitant procedures were performed in 8 patients (3 coronary artery bypass grafts, 2 patent foramen ovale closures, 4 ligations of the left atrial appendage, 3 removals of a right atrial thrombus). Follow-up is 96% complete with a median of 2 years (range, 2 months to 6 years). RESULTS: All patients survived the procedure, but 2 patients died in the hospital on postoperative days 1 (intracerebral bleeding) and 11 (multiorgan failure), accounting for a 30-day mortality of 8% (95% confidence interval: 0.98-0.26). Four patients died later because of their underlying disease. Pre- and postoperative echocardiographic pressure measurements demonstrated the reduction of the pulmonary hypertension to half of the systemic pressure values or less. CONCLUSION: Surgical pulmonary embolectomy is an excellent option for patients with major pulmonary embolism and can be performed with minimal mortality and morbidity. Even patients who present with cardiac arrest and require preoperative cardiopulmonary resuscitation show satisfying results. Immediate surgical desobstruction favorably influences the pulmonary pressure and the recovery of right ventricular function, and remains the treatment of choice for patients with massive central and paracentral embolism with hemodynamic and respiratory compromise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: A satisfactory clinical outcome in dental implant treatment relies on primary stability for immediate load bearing. While the geometric design of an implant contributes to mechanical stability, the nature of the implant surface itself is also critically important. Biomechanical and microcomputerized tomographic evaluation of implant osseointegration was performed to compare alternative structural, chemical and biochemical, and/or pharmaceutical surface treatments applied to an identical established implant design. Materials and Methods: Dental implants with the same geometry but with 6 different surface treatments were tested in vivo in a sheep model (pelvis). Peri-implant bone density and removal torque were compared at 2, 4, and 8 weeks after implantation. Implant surfaces tested were: sandblasted and acid-etched titanium (Ti), sandblasted and etched zirconia, Ti coated with calcium phosphate (CaP), Ti modified via anodic plasma-chemical treatment (APC), bisphosphonate-coated Ti (Ti + Bisphos), and Ti coated with collagen containing chondroitin sulfate (CS). Results: All dental implants were well integrated at the time of sacrifice. There were no significant differences observed in peri-implant bone density between implant groups. After 8 weeks of healing, removal torque values for Ti, Ti + CaP, Ti + Bisphos, and Ti + collagen + CS were significantly higher than those for zirconia and Ti + APC. Conclusions: Whereas the sandblasted/acid-etched Ti implant can still be considered the reference standard surface for dental implants, functional surface modifications such as bisphosphonate or collagen coating seem to enhance early peri-implant bone formation and should be studied further.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the literature on accuracy and clinical performance of computer technology applications in surgical implant dentistry. MATERIALS AND METHODS: Electronic and manual literature searches were conducted to collect information about (1) the accuracy and (2) clinical performance of computer-assisted implant systems. Meta-regression analysis was performed for summarizing the accuracy studies. Failure/complication rates were analyzed using random-effects Poisson regression models to obtain summary estimates of 12-month proportions. RESULTS: Twenty-nine different image guidance systems were included. From 2,827 articles, 13 clinical and 19 accuracy studies were included in this systematic review. The meta-analysis of the accuracy (19 clinical and preclinical studies) revealed a total mean error of 0.74 mm (maximum of 4.5 mm) at the entry point in the bone and 0.85 mm at the apex (maximum of 7.1 mm). For the 5 included clinical studies (total of 506 implants) using computer-assisted implant dentistry, the mean failure rate was 3.36% (0% to 8.45%) after an observation period of at least 12 months. In 4.6% of the treated cases, intraoperative complications were reported; these included limited interocclusal distances to perform guided implant placement, limited primary implant stability, or need for additional grafting procedures. CONCLUSION: Differing levels and quantity of evidence were available for computer-assisted implant placement, revealing high implant survival rates after only 12 months of observation in different indications and a reasonable level of accuracy. However, future long-term clinical data are necessary to identify clinical indications and to justify additional radiation doses, effort, and costs associated with computer-assisted implant surgery.