395 resultados para Lorenz`s attractor


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract Introduction Vertebroplasty (VP) is a cost-efficient alternative to kyphoplasty; however, regarding safety and vertebral body (VB) height restoration, it is considered inferior. We assessed the safety and efficacy of VP in alleviating pain, improving quality of life (QoL) and restoring alignment. Methods In a prospective monocenter case series from May 2007 until July 2008, there were 1,408 vertebroplasties performed during 319 interventions in 306 patients with traumatic, lytic and osteoporotic fractures. The 249 interventions in 233 patients performed because of osteoporotic vertebral fractures were analyzed regarding demographics, treatment and radiographic details, pain alleviation (VAS), QoL improvement (NASS and EQ-5D), complications and predictors for new fractures requiring a reoperation. Results The osteoporotic patient sample consisted of 76.7% (179) females with a median age of 80 years. A total of 54 males had a median age of 77 years. On average, there were 1.8 VBs fractured and 5 VBs treated. The preoperative pain was assessed by the visual analog scale (VAS) and decreased from 54.9 to 40.4 pts after 2 months and 31.2 pts after 6 months. Accordingly, the QoL on the EQ-5D measure (−0.6 to 1) improved from 0.35 pts before surgery to 0.56 pts after 2 and to 0.68 pts after 6 months. The preoperative Beck Index (anterior height/posterior height) improved from a mean of 0.64 preoperative to 0.76 postoperative, remained stable at 2 months and slightly deteriorated to 0.72 at 6 months postoperatively. There were cement leakages in 26% of the fractured VBs and in 1.4% of the prophylactically cemented VBs; there were symptoms in 4.3%, and most of them were temporary hypotension and one pulmonary cement embolism that remained asymptomatic. The univariate regression model revealed a tendency for a reduced risk for new or refractures on radiographs (OR = 2.61, 95% CI 0.92–7.38, p = 0.12) and reoperations (OR = 2.9, 95% CI 0.94–8.949, p = 0.1) when prophylactic augmentation was performed. The final multivariate regression model revealed male patients to have an about three times higher refracture risk (radiographic) (OR = 2.78, p = 0.02) at 6 months after surgery. Patients with a lumbar index fracture had an about three to five times higher refracture/reoperation risk than patients with a thoracic (OR = 0.33/0.35, p = 0.009/0.01) or thoracolumbar (OR = 0.32/0.22, p = 0.099/0.01) index fracture. Conclusion If routinely used, VP is a safe and efficacious treatment option for osteoporotic vertebral fractures with regard to pain relief and improvement of the QoL. Even segmental realignment can be partially achieved with proper patient positioning. Certain patient or fracture characteristics increase the risk for early radiographic refractures or new fractures, or a reoperation; a consequent prophylactic augmentation showed protective tendencies, but the study was underpowered for a final conclusion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This prospective, randomized, controlled trial compares the performance of the pediatric i-gel (Intersurgical Ltd., Wokingham, United Kingdom) with the Ambu AuraOnce laryngeal mask (Ambu A/S, Ballerup, Denmark) in anesthetized and ventilated children.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To determine the incidence of and risk factors for adverse cardiac events during catecholamine vasopressor therapy in surgical intensive care unit patients with cardiovascular failure. METHODS: The occurrence of any of seven predefined adverse cardiac events (prolonged elevated heart rate, tachyarrhythmia, myocardial cell damage, acute cardiac arrest or death, pulmonary hypertension-induced right heart dysfunction, reduction of systemic blood flow) was prospectively recorded during catecholamine vasopressor therapy lasting at least 12 h. RESULTS: Fifty-four of 112 study patients developed a total of 114 adverse cardiac events, an incidence of 48.2 % (95 % CI, 38.8-57.6 %). New-onset tachyarrhythmia (49.1 %), prolonged elevated heart rate (23.7 %), and myocardial cell damage (17.5 %) occurred most frequently. Aside from chronic liver diseases, factors independently associated with the occurrence of adverse cardiac events included need for renal replacement therapy, disease severity (assessed by the Simplified Acute Physiology Score II), number of catecholamine vasopressors (OR, 1.73; 95 % CI, 1.08-2.77; p = 0.02) and duration of catecholamine vasopressor therapy (OR, 1.01; 95 % CI, 1-1.01; p = 0.002). Patients developing adverse cardiac events were on catecholamine vasopressors (p < 0.001) and mechanical ventilation (p < 0.001) for longer and had longer intensive care unit stays (p < 0.001) and greater mortality (25.9 vs. 1.7 %; p < 0.001) than patients who did not. CONCLUSIONS: Adverse cardiac events occurred in 48.2 % of surgical intensive care unit patients with cardiovascular failure and were related to morbidity and mortality. The extent and duration of catecholamine vasopressor therapy were independently associated with and may contribute to the pathogenesis of adverse cardiac events.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Femoro-acetabular impingement can cause pain and degenerative changes of the hip joint. Traditionally, surgical dislocation of the hip joint has been performed for correction of pathologic abnormalities in the proximal part of the femur and the acetabulum. Failures of surgical treatment are often related to postoperative pain in the groin or in the area of the greater trochanter, associated with this surgical approach. The aim of our study was to determine the prevalence and functional impact of pain at the greater trochanter after surgical dislocation of the hip.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives This study sought to compare the efficacy of passive stent coating with titanium-nitride-oxide (TiNO) with drug-eluting stents releasing zotarolimus (ZES) (Endeavor, Medtronic, Minneapolis, Minnesota). Background Stent coating with TiNO has been shown to reduce restenosis compared with bare-metal stents in experimental and clinical studies. Methods In an assessor-blind noninferiority study, 302 patients undergoing percutaneous coronary intervention were randomized to treatment with TiNO or ZES. The primary endpoint was in-stent late loss at 6 to 8 months, and analysis was by intention to treat. Results Both groups were well balanced with respect to baseline clinical and angiographic characteristics. The TiNO group failed to reach the pre-specified noninferiority margin for the primary endpoint (in-stent late loss: 0.64 ± 0.61 mm vs. 0.47 ± 0.48 mm, difference: 0.16, upper 1-sided 95% confidence interval [CI]: 0.26; pnoninferiority = 0.54), and subsequent superiority testing was in favor of ZES (psuperiority = 0.02). In-segment binary restenosis was lower with ZES (11.1%) than with TiNO (20.5%; psuperiority = 0.04). A stratified analysis of the primary endpoint found particularly pronounced differences between stents among diabetic versus nondiabetic patients (0.90 ± 0.69 mm vs. 0.39 ± 0.38 mm; pinteraction = 0.04). Clinical outcomes showed a similar rate of death (0.7% vs. 0.7%; p = 1.00), myocardial infarction (5.3% vs. 6.7%; p = 0.60), and major adverse cardiac events (21.1% vs. 18.0%, hazard ratio: 1.19, 95% CI: 0.71 to 2.00; p = 0.50) at 1 year. There were no differences in rates of definite or probable stent thrombosis (0.7% vs. 0%; p = 0.51) at 1 year. Conclusions Compared with TiNO, ZES was superior with regard to late loss and binary restenosis. The concept of passive stent coating with TiNO remains inferior to drug-eluting stent technology in reducing restenosis. ([TIDE] Randomized Trial Comparing Titan Stent With Zotarolimus-Eluting Stent: NCT00492908)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To investigate the ability of SYNTAX score and Clinical SYNTAX score (CSS) to predict very long-term outcomes in an all-comers population receiving drug-eluting stents.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study sought to assess the impact of the SYNTAX (Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery) score (SXscore) on clinical outcomes in patients undergoing percutaneous coronary intervention.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to assess the impact of body mass index (BMI) on clinical outcome of patients treated by percutaneous coronary intervention (PCI) using drug-eluting stents. Patients were stratified according to BMI as normal (<25 kg/m(2)), overweight (25 to 30 kg/m(2)), or obese (>30 kg/m(2)). At 5-year follow-up all-cause death, myocardial infarction, clinically justified target vessel revascularization (TVR), and definite stent thrombosis were assessed. A complete dataset was available in 7,427 patients, of which 45%, 22%, and 33% were classified according to BMI as overweight, obese, and normal, respectively. Mean age of patients was significantly older in those with a normal BMI (p <0.05). Incidence of diabetes mellitus, hypertension, and dyslipidemia increased as BMI increased (p <0.05). Significantly higher rates of TVR (15.3% vs 12.8%, p = 0.02) and early stent thrombosis (1.5% vs 0.9%, p = 0.04) were observed in the obese compared to the normal BMI group. No significant difference among the 3 BMI groups was observed for the composite of death/myocardial infarction/TVR or for definite stent thrombosis at 5 years, whereas the normal BMI group was at higher risk for all-cause death at 5 years (obese vs normal BMI, hazard ratio 0.74, confidence interval 0.53 to 0.99, p = 0.05; overweight vs normal BMI, hazard ratio 0.73, confidence interval 0.59 to 0.94, p = 0.01) in the multivariate Cox proportional hazard model. Age resulted in a linearly dependent covariate with BMI in the all-cause 5-year mortality multivariate model (p = 0.001). In conclusion, the "obesity paradox" observed in 5-year all-cause mortality could be explained by the higher rate of elderly patients in the normal BMI group and the existence of colinearity between BMI and age. However, obese patients had a higher rate of TVR and early stent thrombosis and a higher rate of other risk factors such as diabetes mellitus, hypertension, and hypercholesterolemia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This prospective study on symptomatic adult patients with femoroacetabular impingement (FAI) who underwent open surgical intervention for management was designed to identify any obvious histological differences in the damaged acetabular cartilage within different subgroups of FAI. 20 patients underwent surgical intervention following safe surgical dislocation of the hip. There were 6 cases of cam impingement, 5 cases of pincer impingement and 9 of the mixed type. Pincer impingement cases demonstrated a characteristic focal, well-circumscribed and localized area of severe damage. On the other hand, cases with cam impingement showed a diffuse area of involvement affecting a larger surface of the acetabular cartilage, with degenerative changes, superficial erosions and some discontinuities. A small biopsy specimen of the acetabular rim including bone, cartilage and labrum from the affected zone was obtained in all cases. Histological evaluation was performed under normal and polarized light microscopy. Histological findings helped corroborate the pre-operative diagnosis and also define the unique nature of impingement and specific damage according to the type of impingement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Compared with bare metal stents (BMS), early generation drug-eluting stents (DES) reduce the risk of revascularisation in patients with ST-elevation myocardial infarction (STEMI) at the expense of an increased risk of very late stent thrombosis (ST). Durable polymer coatings for controlled drug release have been identified as a potential trigger for these late adverse events and this has led to the development of newer generation DES with durable and biodegradable polymer surface coatings with improved biocompatibility. In a recent all-comers trial, biolimus-eluting stents with a biodegradable polymer surface coating were found to reduce the risk of very late ST by 80% compared with sirolimus-eluting stents with durable polymer, which also translated into a lower risk of cardiac death and myocardial infarction (MI) beyond one year.