88 resultados para Loop spaces.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reflected at any level of organization of the central nervous system, most of the processes ranging from ion channels to neuronal networks occur in a closed loop, where the input to the system depends on its output. In contrast, most in vitro preparations and experimental protocols operate autonomously, and do not depend on the output of the studied system. Thanks to the progress in digital signal processing and real-time computing, it is now possible to artificially close the loop and investigate biophysical processes and mechanisms under increased realism. In this contribution, we review some of the most relevant examples of a new trend in in vitro electrophysiology, ranging from the use of dynamic-clamp to multi-electrode distributed feedback stimulation. We are convinced these represents the beginning of new frontiers for the in vitro investigation of the brain, promising to open the still existing borders between theoretical and experimental approaches while taking advantage of cutting edge technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analysed a 610-bp mitochondrial (mt)DNA D-loop fragment in a sample of German draught horse breeds and compared the polymorphic sites with sequences from Arabian, Hanoverian, Exmoor, Icelandic, Sorraia and Przewalski's Horses as well as with Suffolk, Shire and Belgian horses. In a total of 65 horses, 70 polymorphic sites representing 47 haplotypes were observed. The average percentage of polymorphic sites was 11.5% for the mtDNA fragment analysed. In the nine different draught horse breeds including South German, Mecklenburg, Saxon Thuringa coldblood, Rhenisch German, Schleswig Draught Horse, Black Forest Horse, Shire, Suffolk and Belgian, 61 polymorphic sites and 24 haplotypes were found. The phylogenetic analysis failed to show monophyletic groups for the draught horses. The analysis indicated that the draught horse populations investigated consist of diverse genetic groups with respect to their maternal lineage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Angiopoietin-1 (Ang-1) and angiopoietin-2 (Ang-2) have been identified as ligands with different effector functions of the vascular assembly and maturation-mediating receptor tyrosine kinase Tie-2. To understand the molecular interactions of the angiopoietins with their receptor, we have studied the binding of Ang-1 and Ang-2 to the Tie-2 receptor. Enzyme-linked immunosorbent assay-based competition assays and co-immunoprecipitation experiments analyzing the binding of Ang-1 and Ang-2 to truncation mutants of the extracellular domain of Tie-2 showed that the first Ig-like loop of Tie-2 in combination with the epidermal growth factor (EGF)-like repeats (amino acids 1-360) is required for angiopoietin binding. The first Ig-like domain or the EGF-like repeats alone are not capable of binding Ang-1 and Ang-2. Concomitantly, we made the surprising finding that Tie-2 exon-2 knockout mice do express a mutated Tie-2 protein that lacks 104 amino acids of the first Ig-like domain. This mutant Tie-2 receptor is functionally inactive as shown by the lack of ligand binding and receptor phosphorylation. Collectively, the data show that the first 104 amino acids of the Tie-2 receptor are essential but not sufficient for angiopoietin binding. Conversely, the first 360 amino acids (Ig-like domain plus EGF-like repeats) of the Tie-2 receptor are necessary and sufficient to bind both Ang-1 and Ang-2, which suggests that differential receptor binding is not likely to be responsible for the different functions of Ang-1 and Ang-2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Benzodiazepines are widely used drugs exerting sedative, anxiolytic, muscle relaxant, and anticonvulsant effects by acting through specific high affinity binding sites on some GABA(A) receptors. It is important to understand how these ligands are positioned in this binding site. We are especially interested here in the conformation of loop A of the alpha(1)beta(2)gamma(2) GABA(A) receptor containing a key residue for the interaction of benzodiazepines: alpha(1)H101. We describe a direct interaction of alpha(1)N102 with a diazepam- and an imidazobenzodiazepine-derivative. Our observations help to better understand the conformation of this region of the benzodiazepine pocket in GABA(A) receptor.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To test the hypothesis that hyporeflective spaces in the neuroretina found on optical coherence tomography (OCT) examination have different optical reflectivities according to whether they are associated with exudation or degeneration. METHODS: Retrospective analysis of eyes with idiopathic perifoveal telangiectasia (IPT), diabetic macular edema (DME), idiopathic central serous chorioretinopathy (CSC), retinitis pigmentosa (RP), or cone dystrophy (CD) and eyes of healthy control subjects. OCT scans were performed. Raw scan data were exported and used to calculate light reflectivity profiles. Reflectivity data were acquired by projecting three rectangular boxes, each 50 pixels long and 5 pixels wide, into the intraretinal cystoid spaces, centrally onto unaffected peripheral RPE, and onto the prefoveolar vitreous. Light reflectivity in the retinal pigment epithelium (RPE), vitreous, and intraretinal spaces for the different retinal conditions and control subjects were compared. RESULTS: Reflectivities of the vitreous and the RPE were similar among the groups. Hyporeflective spaces in eyes with exudation (DME, RP, and CSC) had higher reflectivity compared with the mean reflectivity of the vitreous, whereas the cystoid spaces in the maculae of the eyes without exudation (CD and IPT) had a lower reflectivity than did the normal vitreous. CONCLUSIONS: Analysis of the light reflectivity profiles may be a tool to determine whether the density of hyporeflective spaces in the macula is greater or less than that of the vitreous, and may be a way to differentiate degenerative from exudative macular disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Immune cells enter the central nervous system (CNS) from the circulation under normal conditions for immunosurveillance and in inflammatory neurologic diseases. This review describes the distinct anatomic features of the CNS vasculature that permit it to maintain parenchymal homeostasis and which necessitate specific mechanisms for neuroinflammation to occur. We review the historical evolution of the concept of the blood-brain barrier and discuss distinctions between diffusion/transport of solutes and migration of cells from the blood to CNS parenchyma. The former is regulated at the level of capillaries, whereas the latter takes place in postcapillary venules. We summarize evidence that entry of immune cells into the CNS parenchyma in inflammatory conditions involves 2 differently regulated steps: transmigration of the vascular wall into the perivascular space and progression across the glia limitans into the parenchyma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Whether or not a protective stoma reduces the rate of anastomotic leakage after distal colorectal anastomosis is still discussed controversially. It does however facilitate clinical management once leakage has occurred. Loop ileostomies seem to be associated with a lower morbidity and a better quality of life compared to loop colostomies. Generally, diverting loop ileostomies are secured at skin level by means of a supporting device in order to prevent retraction of the ileostomy into the abdomen. However, due to the supporting rod, difficulties may occur in applying a stoma bag correctly and leakage of faeces onto the skin may occur even with correct eversion of the afferent limb. Our aim was to compare morbidity and time to self-sufficient stoma-care in patients having a loop ileostomy with rod to those without rod. Methods: A total of 60 patients necessitating loop ileostomy were analyzed. Patients received surgery in of the two involved institutions according to inhouse standard procedures. 30 patients had an ileostomy with rod (VCHK Inselspital) and a further 30 without rod (KSW Winterthur). Morbidity and time to self-sufficiency regarding stoma care was analyzed during the first 90 postoperative days. Morbidity was determined according to a scoring system ranging from 0 to 4 points for any given set of possible complications (bleeding, necrosis, skin irritation, abscess, stenosis, retraction, fistula, prolapse, parastomal hernia, incomplete diversion), where 0 = no complication and 4 = severe complication. Continuous variables were expressed as median (95% Confidence Interval). For comparisons between the groups the Mann-Whitney U test was used, between categorical variables the X2 test was applied. Results: There were no significant differences in length of hospital stay or time to self-sufficient stoma-care between the groups. Although not significant, patients with a rod ileostomy had a tendency towards more stoma-related complications as well as stoma-related reoperations. The number of patients reaching total self-sufficiency regarding stoma care was higher after rodless ileostomy. Conclusion: According to our data, rodless ileostomies seemto fare just as well as those with a supporting rod, with equal morbidity rates and more patients reaching self-sufficient stoma care. Therefore routine application of a rod for diverting loop ileostomy seems unnecessary

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluates the clinical applicability of administering sodium nitroprusside by a closed-loop titration system compared with a manually adjusted system. The mean arterial pressure (MAP) was registered every 10 and 30 sec during the first 150 min after open heart surgery in 20 patients (group 1: computer regulation) and in ten patients (group 2: manual regulation). The results (16,343 and 2,912 data points in groups 1 and 2, respectively), were then analyzed in four time frames and five pressure ranges to indicate clinical efficacy. Sixty percent of the measured MAP in both groups was within the desired +/- 10% during the first 10 min. Thereafter until the end of observation, the MAP was maintained within +/- 10% of the desired set-point 90% of the time in group 1 vs. 60% of the time in group 2. One percent and 11% of data points were +/- 20% from the set-point in groups 1 and 2, respectively (p less than .05, chi-square test). The computer-assisted therapy provided better control of MAP, was safe to use, and helped to reduce nursing demands.