236 resultados para LUMBAR SPINE


Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper proposed an automated 3D lumbar intervertebral disc (IVD) segmentation strategy from MRI data. Starting from two user supplied landmarks, the geometrical parameters of all lumbar vertebral bodies and intervertebral discs are automatically extracted from a mid-sagittal slice using a graphical model based approach. After that, a three-dimensional (3D) variable-radius soft tube model of the lumbar spine column is built to guide the 3D disc segmentation. The disc segmentation is achieved as a multi-kernel diffeomorphic registration between a 3D template of the disc and the observed MRI data. Experiments on 15 patient data sets showed the robustness and the accuracy of the proposed algorithm.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper proposed an automated three-dimensional (3D) lumbar intervertebral disc (IVD) segmentation strategy from Magnetic Resonance Imaging (MRI) data. Starting from two user supplied landmarks, the geometrical parameters of all lumbar vertebral bodies and intervertebral discs are automatically extracted from a mid-sagittal slice using a graphical model based template matching approach. Based on the estimated two-dimensional (2D) geometrical parameters, a 3D variable-radius soft tube model of the lumbar spine column is built by model fitting to the 3D data volume. Taking the geometrical information from the 3D lumbar spine column as constraints and segmentation initialization, the disc segmentation is achieved by a multi-kernel diffeomorphic registration between a 3D template of the disc and the observed MRI data. Experiments on 15 patient data sets showed the robustness and the accuracy of the proposed algorithm.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

INTRODUCTION Distraction-based spinal growth modulation by growing rods or vertical expandable prosthetic titanium ribs (VEPTRs) is the mainstay of instrumented operative strategies to correct early onset spinal deformities. In order to objectify the benefits, it has become common sense to measure the gain in spine height by assessing T1-S1 distance on anteroposterior (AP) radiographs. However, by ignoring growth changes on vertebral levels and by limiting measurement to one plane, valuable data is missed regarding the three-dimensional (3D) effects of growth modulation. This information might be interesting when it comes to final fusion or, even more so, when the protective growing implants are removed and the spine re-exposed to physiologic forces at the end of growth. METHODS The goal of this retrospective radiographic study was to assess the growth modulating impact of year-long, distraction-based VEPTR treatment on the morphology of single vertebral bodies. We digitally measured lumbar vertebral body height (VBH) and upper endplate depth (VBD) at the time of the index procedure and at follow-up in nine patients with rib-to-ileum constructs (G1) spanning an anatomically normal lumbar spine. Nine patients with congenital thoracic scoliosis and VEPTR rib-to-rib constructs, but uninstrumented lumbar spines, served as controls (G2). All had undergone more than eight half-yearly VEPTR expansions. A Wilcoxon signed-rank test was used for statistical comparison of initial and follow-up VBH, VBD and height/depth (H/D) ratio (significance level 0.05). RESULTS The average age was 7.1 years (G1) and 5.2 year (G2, p > 0.05) at initial surgery; the average overall follow-up time was 5.5 years (p = 1). In both groups, VBH increased significantly without a significant intergroup difference. Group 1 did not show significant growth in depth, whereas VBD increased significantly in the control group. As a consequence, the H/D ratio increased significantly in group 1 whereas it remained unchanged in group 2. The growth rate for height in mm/year was 1.4 (group 1) and 1.1 (group 2, p = 0.45), and for depth, it was -0.3 and 1.1 (p < 0.05), respectively. CONCLUSIONS VEPTR growth modulating treatment alters the geometry of vertebral bodies by increasing the H/D ratio. We hypothesize that the implant-related deprivation from axial loads (stress-shielding) impairs anteroposterior growth. The biomechanical consequence of such slender vertebrae when exposed to unprotected loads in case of definitive VEPTR removal at the end of growth is uncertain.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose Accurate three-dimensional (3D) models of lumbar vertebrae can enable image-based 3D kinematic analysis. The common approach to derive 3D models is by direct segmentation of CT or MRI datasets. However, these have the disadvantages that they are expensive, timeconsuming and/or induce high-radiation doses to the patient. In this study, we present a technique to automatically reconstruct a scaled 3D lumbar vertebral model from a single two-dimensional (2D) lateral fluoroscopic image. Methods Our technique is based on a hybrid 2D/3D deformable registration strategy combining a landmark-to-ray registration with a statistical shape model-based 2D/3D reconstruction scheme. Fig. 1 shows different stages of the reconstruction process. Four cadaveric lumbar spine segments (total twelve lumbar vertebrae) were used to validate the technique. To evaluate the reconstruction accuracy, the surface models reconstructed from the lateral fluoroscopic images were compared to the associated ground truth data derived from a 3D CT-scan reconstruction technique. For each case, a surface-based matching was first used to recover the scale and the rigid transformation between the reconstructed surface model Results Our technique could successfully reconstruct 3D surface models of all twelve vertebrae. After recovering the scale and the rigid transformation between the reconstructed surface models and the ground truth models, the average error of the 2D/3D surface model reconstruction over the twelve lumbar vertebrae was found to be 1.0 mm. The errors of reconstructing surface models of all twelve vertebrae are shown in Fig. 2. It was found that the mean errors of the reconstructed surface models in comparison to their associated ground truths after iterative scaled rigid registrations ranged from 0.7 mm to 1.3 mm and the rootmean squared (RMS) errors ranged from 1.0 mm to 1.7 mm. The average mean reconstruction error was found to be 1.0 mm. Conclusion An accurate, scaled 3D reconstruction of the lumbar vertebra can be obtained from a single lateral fluoroscopic image using a statistical shape model based 2D/3D reconstruction technique. Future work will focus on applying the reconstructed model for 3D kinematic analysis of lumbar vertebrae, an extension of our previously-reported imagebased kinematic analysis. The developed method also has potential applications in surgical planning and navigation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to assess the prevalence of incomplete distal renal tubular acidosis (idRTA) in men with recurrent calcium nephrolithiasis and its potential impact on bone mineral density. We conducted a retrospective analysis of 150 consecutive, male idiopathic recurrent calcium stone formers (RCSFs), which had originally been referred to the tertiary care stone center of the University Hospital of Berne for further metabolic evaluation. All RCSFs had been maintained on a free-choice diet while collecting two 24-h urine samples and delivered second morning urine samples after 12 h fasting. Among 12 RCSFs with a fasting urine pH >5.8, a modified 3-day ammonium chloride loading test identified idRTA in 10 patients (urine pH >5.32, idRTA group). We matched to each idRTA subject 5 control subjects from the 150 RCSFs, primary by BMI and then by age, i.e., 50 patients, without any acidification defect (non-RTA group) for comparative biochemistry and dual energy X-ray absorptiometry (DEXA) analyses. The prevalence of primary idRTA among RCSFs was 6.7% (10/150). Patients with idRTA had significantly higher 2-h fasting and 24-h urine pH (2-h urine pH: 6.6 ± 0.4 vs. 5.2 ± 0.1, p = 0.001; 24-h urine pH: 6.1 ± 0.2 vs. 5.3 ± 0.3, p = 0.001), 24-h urinary calcium excretion (7.70 ± 1.75 vs. 5.69 ± 1.73 mmol/d, p = 0.02), but significantly lower 24-h urinary urea excretion (323 ± 53 vs. 399 ± 114 mmol/d, p = 0.01), urinary citrate levels (2.32 ± 0.82 vs. 3.01 ± 0.72 mmol/d, p = 0.04) and renal phosphate threshold normalized for the glomerular filtration rate (TmPO(4)/GFR: 0.66 ± 0.17 vs. 0.82 ± 0.21, p = 0.03) compared to non-RTA patients. No significant difference in bone mineral density (BMD) was found between idRTA and non-RTA patients for the lumbar spine (LS BMD (g/cm(2)): 1.046 ± 0.245 SD vs. 1.005 ± 0.119 SD, p = 0.42) or femoral neck (FN BMD (g/cm(2)): 0.830 ± 0.135 SD vs. 0.852 ± 0.127 SD). Thus, idRTA occurs in 1 in 15 male RCSFs and should be sought in all recurrent calcium nephrolithiasis patients. Bone mineral density, however, does not appear to be significantly affected by idRTA.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Denosumab is an approved therapy for postmenopausal women with osteoporosis at high or increased risk for fracture. In the FREEDOM study, denosumab reduced fracture risk and increased bone mineral density (BMD). We report the spine and hip dual-energy X-ray absorptiometry (DXA) BMD responses from the overall study of 7808 women and from a substudy of 441 participants in which more extensive spine and hip assessments as well as additional skeletal sites were evaluated. Significant BMD improvements were observed as early as 1mo at the lumbar spine, total hip, and trochanter (all p<0.005 vs placebo and baseline). BMD increased progressively at the lumbar spine, total hip, femoral neck, trochanter, 1/3 radius, and total body from baseline to months 12, 24, and 36 (all p<0.005 vs placebo and baseline). BMD gains above the least significant change of more than 3% at 36 months were observed in 90% of denosumab-treated subjects at the lumbar spine and 74% at the total hip, and gains more than 6% occurred in 77% and 38%, respectively. In conclusion, denosumab treatment resulted in significant, early, and continued BMD increases at both trabecular and cortical sites throughout the skeleton over 36mo with important gains observed in most subjects.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE: Postmenopausal bone loss and osteoporotic fractures can be prevented by hormone replacement therapy (HRT). However, opposed HRT may increase the risk of breast cancer above that associated with estrogen alone and in non-hysterectomized women estrogen substitution alone increases the risk of uterine cancer, which triggered renewed interest in long-cycle HRT regimens (estrogen replacement therapy with progesterone-free intervals up to 6 months). The effects on bone of such long-cycle HRT regimens are unknown. The objective of the present study was to compare the effects on bone and the endometrium of long-cycle HRT and conventional HRT. METHODS: Seventy-three healthy non-hysterectomized postmenopausal women were randomized to either conventional HRT (estradiol (E2) 2 mg/d during 12 days, E2 2 mg/d plus 1 mg/d of norethisterone acetate (NETA) during 10 days, E2 1 mg/d for 6 days) or long-cycle HRT treatment (two cycles with E2 2 mg/d during 28 days, followed by one cycle of conventional HRT and repeated every 3 months). Primary endpoint was the change in bone mineral density (BMD) at the lumbar spine (LS) over 24 months. RESULTS: BMD at LS increased significantly versus baseline in both treatment groups (conventional HRT +3.8 +/- 0.6%, long-cycle HRT +3.3 +/- 0.5%, p < 0.0001 for both) with no significant difference between treatment groups over 24 months. Similar significant BMD increases versus baseline were observed at the femoral neck, while biochemical markers of bone turnover (osteocalcin and deoxypyridinoline) were significantly decreased over 24 months. There were no endometrial or breast related adverse events reported. CONCLUSION: Long-cycle HRT may be a valid alternative to conventional HRT with regard to protection against postmenopausal bone loss.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCTION: Osteoporosis is not only responsible for an increased number of metaphyseal and spinal fractures but it also complicates their treatment. To prevent the initial loosening, we developed a new implant with an enlarged implant/bone interface based on the concept of perforated, hollow cylinders. We evaluated whether osseointegration of a hollow cylinder based implant takes place in normal or osteoporotic bone of sheep under functional loading conditions during anterior stabilization of the lumbar spine. MATERIALS AND METHODS: Osseointegration of the cylinders and status of the fused segments (ventral corpectomy, replacement with iliac strut, and fixation with testing implant) were investigated in six osteoporotic (age 6.9 +/- 0.8 years, mean body weight 61.1 +/- 5.2 kg) and seven control sheep (age 6.1 +/- 0.2 years, mean body weight 64.9 +/- 5.7 kg). Osteoporosis was introduced using a combination protocol of ovariectomy, high-dose prednisone, calcium and phosphor reduced diet and movement restriction. Osseointegration was quantified using fluorescence and conventional histology; fusion status was determined using biomechanical testing of the stabilized segment in a six-degree-of-freedom loading device as well as with radiological and histological staging. RESULTS: Intact bone trabeculae were found in 70% of all perforations without differences between the two groups (P = 0.26). Inside the cylinders, bone volume/total volume was significantly higher than in the control vertebra (50 +/- 16 vs. 28 +/- 13%) of the same animal (P<0.01), but significantly less (P<0.01) than in the near surrounding (60 +/- 21%). After biomechanical testing as described in Sect. "Materials and methods", seven spines (three healthy and four osteoporotic) were classified as completely fused and six (four healthy and two osteoporotic) as not fused after a 4-month observation time. All endplates were bridged with intact trabeculae in the histological slices. CONCLUSIONS: The high number of perforations, filled with intact trabeculae, indicates an adequate fixation; bridging trabeculae between adjacent endplates and tricortical iliac struts in all vertebrae indicates that the anchorage is adequate to promote fusion in this animal model, even in the osteoporotic sheep.