36 resultados para Hospital performance improvement
Resumo:
A medical cyclotron accelerating H- ions to 18 MeV is in operation at the Bern University Hospital (Inselspital). It is the commercial IBA 18/18 cyclotron equipped with a specifically conceived 6 m long external beam line ending in a separate bunker. This feature is unique for a hospital-based facility and makes it possible to conduct routine radioisotope production for PET diagnostics in parallel with multidisciplinary research activities, among which are novel particle detectors, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. Several of these activities, such as radiobiology experiments for example, require low current beams down to the pA range, while medical cyclotrons are designed for high current operation above 10 μA. In this paper, we present the first results on the low current performance of a PET medical cyclotron obtained by ion source, radio-frequency and main coil tuning. With this method, stable beam currents down to (1.5+/- 0.5 ) pA were obtained and measured with a high-sensitivity Faraday cup located at the end of the beam transport line.
Resumo:
The improvement and performance of a micellar electrokinetic capillary chromatography assay for cefepime in human serum and plasma with a 50 μm id fused-silica capillary elongated from 40 to 60 cm is reported. Sample preparation with dodecylsulfate protein precipitation at pH 4.5, the pH 9.1 separation medium and the applied voltage were as reported previously[16]. The change resulted in a significant lower current, higher resolution and increased detection time intervals. The performance of the assay with multi-level internal calibration was assessed with calibration and control samples. Quality assurance data of a two year period assessed under the new conditions demonstrated the robustness of the assay. In serum samples of patients who received both cefepime and sulfamethoxazole, cefepime could not be detected due to the inseparability of the two compounds. The presence of an interference can be recognized by an increased peak width (width > 0.2 min), the appearance of a shoulder or an unresolved double peak. The patient data gathered during a three year period reveal that introduction of therapeutic drug monitoring led to a 50% reduction of the median drug level. The data suggest that therapeutic drug monitoring can help to minimize the risk of major adverse reactions and to increase drug safety on an individual basis. This article is protected by copyright. All rights reserved.
Resumo:
Heme oxygenase-1 (HO-1) is an enzyme induced by hypoxia and reperfusion injury, and is associated with organ dysfunction in critically ill patients. Patients resuscitated from out-of-hospital cardiac arrest (OHCA) are subjected to hypoxemia, brain injury, and organ dysfunction. Accordingly, we studied HO-1 among these patients. A total of 143 OHCA patients resuscitated from a shockable initial rhythm and admitted to an ICU were included, with plasma HO-1 measured at ICU admission and at 24 h. We analyzed the associations between plasma HO-1 and time to return of spontaneous circulation (ROSC), 90-day mortality, and 12-month Cerebral Performance Category (CPC). HO-1 plasma concentrations were higher after OHCA compared with controls. HO-1 concentrations at admission and on day 1 associated with ROSC (P = 0.002 to P = 0.003). Admission and day 1 HO-1 plasma concentrations were higher in 90-day non-survivors than in survivors (P = 0.017, 0.026). In addition, poor neurological outcome (CPC 3-5) was associated with higher HO-1 plasma levels at admission (P = 0.024). Admission plasma HO-1 levels had an AUC of 0.623 to predict 90-day mortality and an AUC of 0.611 to predict CPC 3 to 5. In conclusion, we found that higher HO-1 plasma levels are associated with longer ROSC and poor long-term outcome.
Resumo:
AIM To assess whether the established cardiovascular biomarker N-terminal pro-B-type natriuretic peptide (NT-proBNP) provides prognostic information in patients with out-of-hospital cardiac arrest due to ventricular tachycardia or fibrillation (OHCA-VT/VF). METHODS We measured NT-proBNP levels in 155 patients with OHCA-VT/VF enrolled into a prospective multicenter observational study in 21 ICUs in Finland. Blood samples were drawn <6h of OHCA-VT/VF and later after 24h, 48h, and 96h. The end-points were mortality and neurological outcome classified according to Cerebral Performance Category (CPC) after one year. NT-proBNP levels were compared to high-sensitivity troponin T (hs-TnT) levels and established risk scores. RESULTS NT-proBNP levels were higher in non-survivors compared to survivors on study inclusion (median 1003 [quartile (Q) 1-3 502-2457] vs. 527 [179-1284]ng/L, p=0.001) and after 24h (1913 [1012-4573] vs. 1080 [519-2210]ng/L, p<0.001). NT-proBNP levels increased from baseline to 96h after ICU admission (p<0.001). NT-proBNP levels were significantly correlated to hs-TnT levels after 24h (rho=0.27, p=0.001), but not to hs-TnT levels on study inclusion (rho=0.05, p=0.67). NT-proBNP levels at all time points were associated with clinical outcome, but only NT-proBNP levels after 24h predicted mortality and poor neurological outcome, defined as CPC 3-5, in models that adjusted for SAPS II and SOFA scores. hs-TnT levels did not add prognostic information to NT-proBNP measurements alone. CONCLUSION NT-proBNP levels at 24h improved risk assessment for poor outcome after one year on top of established risk indices, while hs-TnT measurements did not further add to risk prediction.
Resumo:
BACKGROUND The application of therapeutic hypothermia (TH) for 12 to 24 hours following out-of-hospital cardiac arrest (OHCA) has been associated with decreased mortality and improved neurological function. However, the optimal duration of cooling is not known. We aimed to investigate whether targeted temperature management (TTM) at 33 ± 1 °C for 48 hours compared to 24 hours results in a better long-term neurological outcome. METHODS The TTH48 trial is an investigator-initiated pragmatic international trial in which patients resuscitated from OHCA are randomised to TTM at 33 ± 1 °C for either 24 or 48 hours. Inclusion criteria are: age older than 17 and below 80 years; presumed cardiac origin of arrest; and Glasgow Coma Score (GCS) <8, on admission. The primary outcome is neurological outcome at 6 months using the Cerebral Performance Category score (CPC) by an assessor blinded to treatment allocation and dichotomised to good (CPC 1-2) or poor (CPC 3-5) outcome. Secondary outcomes are: 6-month mortality, incidence of infection, bleeding and organ failure and CPC at hospital discharge, at day 28 and at day 90 following OHCA. Assuming that 50 % of the patients treated for 24 hours will have a poor outcome at 6 months, a study including 350 patients (175/arm) will have 80 % power (with a significance level of 5 %) to detect an absolute 15 % difference in primary outcome between treatment groups. A safety interim analysis was performed after the inclusion of 175 patients. DISCUSSION This is the first randomised trial to investigate the effect of the duration of TTM at 33 ± 1 °C in adult OHCA patients. We anticipate that the results of this trial will add significant knowledge regarding the management of cooling procedures in OHCA patients. TRIAL REGISTRATION NCT01689077.
Resumo:
THE AIM OF THE STUDY There are limited data on blood pressure targets and vasopressor use following cardiac arrest. We hypothesized that hypotension and high vasopressor load are associated with poor neurological outcome following out-of-hospital cardiac arrest (OHCA). METHODS We included 412 patients with OHCA included in FINNRESUSCI study conducted between 2010 and 2011. Hemodynamic data and vasopressor doses were collected electronically in one, two or five minute intervals. We evaluated thresholds for time-weighted (TW) mean arterial pressure (MAP) and outcome by receiver operating characteristic (ROC) curve analysis, and used multivariable analysis adjusting for co-morbidities, factors at resuscitation, an illness severity score, TW MAP and total vasopressor load (VL) to test associations with one-year neurologic outcome, dichotomized into either good (1-2) or poor (3-5) according to the cerebral performance category scale. RESULTS Of 412 patients, 169 patients had good and 243 patients had poor one-year outcomes. The lowest MAP during the first six hours was 58 (inter-quartile range [IQR] 56-61) mmHg in those with a poor outcome and 61 (59-63) mmHg in those with a good outcome (p<0.01), and lowest MAP was independently associated with poor outcome (OR 1.02 per mmHg, 95% CI 1.00-1.04, p=0.03). During the first 48h the median (IQR) of the TW mean MAP was 80 (78-82) mmHg in patients with poor, and 82 (81-83) mmHg in those with good outcomes (p=0.03) but in multivariable analysis TWA MAP was not associated with outcome. Vasopressor load did not predict one-year neurologic outcome. CONCLUSIONS Hypotension occurring during the first six hours after cardiac arrest is an independent predictor of poor one-year neurologic outcome. High vasopressor load was not associated with poor outcome and further randomized trials are needed to define optimal MAP targets in OHCA patients.