36 resultados para Generation of 1898
Resumo:
The quadrupole mass spectrometer (QMS) has over 30 years of spaceflight heritage in making important neutral gas and low energy ion observations. Given their geometrical constraints, these instruments are currently operated at the extreme limit of their capabilities. However, a technique called higher order auxiliary excitation provides a set of novel, robust, electronics-based solutions for improving the performance of these sensors. By driving the quadrupole rods with an additional frequency nearly twice that of the normal RF operating frequency, substantially increased abundance sensitivity, maximum attainable mass resolution, and peak stability can be achieved through operation of voltage scan lines through the center of formed upper stability islands. Such improvements are modeled using numerical simulations of ion trajectories in a quadrupole field with and without applied higher order auxiliary excitation. When compared to a traditional QMS with a mass range up to 500Da, sensors can be designed with the same precision electronics to have expected mass ranges beyond 1500Da with a power increase of less than twice that of its heritage implementations.
Resumo:
Background: Feedback is considered to be one of the most important drivers of learning. One form of structured feedback used in medical settings is multisource feedback (MSF). This feedback technique provides the opportunity to gain a differentiated view on a doctor’s performance from several perspectives using a questionnaire and a facilitating conversation, in which learning goals are formulated. While many studies have been conducted on the validity, reliability and feasibility of the instrument, little is known about the impact of factors that might influence the effects of MSF on clinical performance. Summary of Work: To study under which circumstances MSF is most effective, we performed a literature review on Google Scholar with focus on MSF and feedback in general. Main key-words were: MSF, multi-source-feedback, multi source feedback, and feedback each combined with influencing/ hindering/ facilitating factors, effective, effectiveness, doctors-intraining, and surgery. Summary of Results: Based on the literature, we developed a preliminary model of facilitating factors. This model includes five main factors influencing MSF: questionnaire, doctor-in-training, group of raters, facilitating supervisor, and facilitating conversation. Discussion and Conclusions: Especially the following points that might influence MSF have not yet been sufficiently studied: facilitating conversation with the supervisor, individual aspects of doctors-in-training, and the causal relations between influencing factors. Overall there are only very few studies focusing on the impact of MSF on actual and long-term performance. We developed a preliminary model of hindering and facilitating factors on MSF. Further studies are needed to better understand under which circumstances MSF is most effective. Take-home messages: The preliminary model might help to guide further studies on how to implement MSF to use it at its full potential.
Resumo:
The generation of rhythmic electrical activity is a prominent feature of spinal cord circuits that is used for locomotion and also for circuit refinement during development. The mechanisms involved in rhythm generation in spinal cord networks are not fully understood. It is for example not known whether spinal cord rhythms are driven by pacemaker neurons and if yes, which neurons are involved in this function. We studied the mechanisms involved in rhythm generation in slice cultures from fetal rats that were grown on multielectrode arrays (MEAs). We combined multisite extracellular recordings from the MEA electrodes with intracellular patch clamp recordings from single neurons. We found that spatially restricted oscillations of activity appeared in most of the cultures spontaneously. Such activity was based on intrinsic activity in a percentage of the neurons that could activate the spinal networks through recurrent excitation. The local oscillator networks critically involved NMDA, AMPA and GABA / glycine receptors at subsequent phases of the oscillation cycle. Intrinsic spiking in individual neurons (in the absence of functional synaptic coupling) was based on persistent sodium currents. Intrinsic firing as well as persistent sodium currents were increased by 5-HT through 5-HT2 receptors. Comparing neuronal activity to muscle activity in co-cultures of spinal cord slices with muscle fibers we found that a percentage of the intrinsically spiking neurons were motoneurons. These motoneurons were electrically coupled among each other and they could drive the spinal networks through cholinergic recurrent excitation. These findings open the possibility that during development rhythmic activity in motoneurons is not only involved in circuit refinement downstream at the neuromuscular endplates but also upstream at the level of spinal cord circuits.
Resumo:
We present a power-scalable approach for yellow laser-light generation based on standard Ytterbium (Yb) doped fibers. To force the cavity to lase at 1154 nm, far above the gain-maximum, measures must be taken to fulfill lasing condition and to suppress competing amplified spontaneous emission (ASE) in the high-gain region. To prove the principle we built a fiber-laser cavity and a fiber-amplifier both at 1154 nm. In between cavity and amplifier we suppressed the ASE by 70 dB using a fiber Bragg grating (FBG) based filter. Finally we demonstrated efficient single pass frequency doubling to 577 nm with a periodically poled lithium niobate crystal (PPLN). With our linearly polarized 1154 nm master oscillator power fiber amplifier (MOFA) system we achieved slope efficiencies of more than 15 % inside the cavity and 24 % with the fiber-amplifier. The frequency doubling followed the predicted optimal efficiency achievable with a PPLN crystal. So far we generated 1.5 W at 1154nm and 90 mW at 577 nm. Our MOFA approach for generation of 1154 nm laser radiation is power-scalable by using multi-stage amplifiers and large mode-area fibers and is therefore very promising for building a high power yellow laser-light source of several tens of Watt.