103 resultados para Ferrovia Milano-Como.


Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The diagnosis of a periprosthetic joint infection (PJI) can be challenging, either because of the variable clinical presentation or because of previous antimicrobial treatment interfering with the detection of the pathogen. In recent years, various means to diagnose PJI have been analyzed. These include invasive and non-invasive laboratory tests, imaging procedures, and novel techniques such as sonication of implants and the use of molecular microbiology. In this review, both established and novel diagnostic procedures are presented. An algorithm for detecting PJI in patients with acute and chronic symptoms is proposed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Mismatches between pump output and venous return in a continuous-flow ventricular assist device may elicit episodes of ventricular suction. This research describes a series of in vitro experiments to characterize the operating conditions under which the EVAHEART centrifugal blood pump (Sun Medical Technology Research Corp., Nagano, Japan) can be operated with minimal concern regarding left ventricular (LV) suction. Methods: The pump was interposed into a pneumatically driven pulsatile mock circulatory system (MCS) in the ventricular apex to aorta configuration. Under varying conditions of preload, afterload, and systolic pressure, the speed of the pump was increased step-wise until suction was observed. Identification of suction was based on pump inlet pressure. Results: In the case of reduced LV systolic pressure, reduced preload (=10 mmHg), and afterload (=60 mmHg), suction was observed for speeds =2,200 rpm. However, suction did not occur at any speed (up to a maximum speed of 2,400 rpm) when preload was kept within 10-14 mmHg and afterload =80 mmHg. Although in vitro experiments cannot replace in vivo models, the results indicated that ventricular suction can be avoided if sufficient preload and afterload are maintained. Conclusion: Conditions of hypovolemia and/or hypotension may increase the risk of suction at the highest speeds, irrespective of the native ventricular systolic pressure. However, in vitro guidelines are not directly transferrable to the clinical situation; therefore, patient-specific evaluation is recommended, which can be aided by ultrasonography at various points in the course of support.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chorea-acanthocytosis is a rare autosomal recessive disorder. To date, treatment is only symptomatic and supportive. Results from the few reports of chorea-acanthocytosis patients treated with deep brain stimulation (DBS) have been inconsistent. We present case reports for two patients with chorea-acanthocytosis who received DBS treatment and compare the outcomes with results from the literature. Both patients showed the typical clinical features of chorea-acanthocytosis with motor symptoms resistant to medical treatment. Chorea was significantly improved following low-frequency DBS treatment in both patients. However, dystonia was only mildly improved. Four chorea-acanthocytosis patients treated with DBS treatment have been reported in the literature. One patient had improvement with low-frequency DBS stimulation, while another two had improvement with higher-frequency DBS. One patient, however, did not improve with either low-frequency or high-frequency DBS. Bilateral DBS to the GPi can improve chorea and dystonia in some patients with intractable chorea-acanthocytosis. However, selection criteria for the most promising candidates must be defined, and the long-term benefits evaluated in clinical studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The low diagnostic yield of vitrectomy specimen analysis in chronic idiopathic uveitis (CIU) has been related to the complex nature of the underlying disease and to methodologic and tissue immanent factors in older studies. In an attempt to evaluate the impact of recently acquired analytic methods, the authors assessed the current diagnostic yield in CIU. METHODS: Retrospective analysis of consecutive vitrectomy specimens from patients with chronic endogenous uveitis (n = 56) in whom extensive systemic workup had not revealed a specific diagnosis (idiopathic) and medical treatment had not resulted in a satisfying clinical situation. Patients with acute postoperative endophthalmitis served a basis for methodologic comparison (Group 2; n = 21). RESULTS: In CIU, a specific diagnosis provided in 17.9% and a specific diagnosis excluded in 21.4%. In 60.7% the laboratory investigations were inconclusive. In postoperative endophthalmitis, microbiological culture established the infectious agent in 47.6%. In six of eight randomly selected cases, eubacterial PCR identified bacterial DNA confirming the culture results in three, remaining negative in two with a positive culture and being positive in three no growth specimens. A double negative result never occurred, suggesting a very high detection rate, when both tests were applied. CONCLUSIONS: The diagnostic yield of vitrectomy specimen analysis has not been improved by currently routinely applied methods in recent years in contrast to the significantly improved sensitivity of combined standardized culture and PCR analysis in endophthalmitis. Consequently, the low diagnostic yield in CIU has to be attributed to insufficient understanding of the underlying pathophysiologic mechanisms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Patency of small synthetic bypass grafts is inferior compared to autologous grafts for revascularization procedures. Titanium coating of foreign surfaces has shown to decrease thrombogenicity, enhance biocompatibility and promote adhesion of endothelial cells. The aim of this study was to test the effect of titanium coating of small diameter ePTFE grafts on short term patency, neo-endothelialization and neointimal proliferation. METHODS: Bilateral carotid graft interposition was performed in 5 pigs with uncoated (n=5) and titanium-coated (n=5) ePTFE grafts (internal diameter=4 mm, length=5 cm), thus each pig served as its own control. At the end of the study (30 +/- 3 days), patency and stenosis severity was assessed by carotid angiography. Animals were sacrificed and grafts were excised for histology and scanning electron microscopy. Morphometry of histologic sections was carried out to determine neointimal proliferation and percentage of neo-endothelial coverage. RESULTS: Patency rate was 80% for uncoated and titanium-coated grafts. Quantitative angiography did not show any significant difference in lumen size between two groups. Morphometry revealed a significantly higher cellular coverage with CD31 positive endothelial cells for titanium-coated (84 +/- 19%) than uncoated grafts (48 +/- 26%, p<0.001). There was a non significant trend (p=0.112) towards increased neointimal proliferation in titanium-coated (94 +/- 61 micron2/micron) compared to uncoated grafts (60 +/- 57 micron2/micron). CONCLUSIONS: Patency rate in uncoated and titanium-coated ePTFE grafts is similar at one month. However, titanium coated grafts show a significant improvement in neo-endothelialization compared to uncoated grafts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: In view of the obvious practical advantages, the most common test for hematuria is currently a reagent strip. METHODS: A standardized microscopic examination of the sediment was performed in 20 asymptomatic children referred for evaluation of chronic isolated microhematuria detected by means of a reagent strip. RESULTS: In 6 of the 20 children the microscopic examination failed to confirm the result of the dipstick test. CONCLUSIONS: Confirmation for the presence of hematuria by microscopy is the most important step in children with a positive dipstick for urinary blood.

Relevância:

10.00% 10.00%

Publicador: