43 resultados para FREQUENCY-RESPONSE MEASUREMENT
Resumo:
Speaking up about patient safety is vital to avoid errors reaching the patient and to improve a culture of safety. This study investigated the prevalence of non-speaking up despite concerns for safety and aimed to identify predictors for withholding voice among healthcare professionals (HCPs) in oncology. A self-administered questionnaire assessed safety concerns, speaking up beliefs and behaviours among nurses and doctors from nine oncology departments. Multiple regression analysis was used to identify predictors for withholding safety concerns. A total of 1013 HCPs returned the completed survey (response rate 65%). Safety concerns were common among responders. Fifty-four per cent reported to recognise their colleagues making potentially harmful errors at least sometimes. A majority of responders reported at least some episodes of withholding concerns about patient safety. Thirty-seven per cent said they remained silent at least once when they had information that might have helped prevent an incident. Respondents believed that a high level of interpersonal, communication and coping skills are necessary to speak up about patient safety issues at their workplace. Higher levels of perceived advocacy for patient safety and psychological safety significantly decreased the frequency of withholding voice. Remaining silent about safety concerns is a common phenomenon in oncology. Improved strategies are needed to support staff in effective communication and make cancer care safer.
Resumo:
When subjects are required to generate a random sequence of numbers they typically produce too many forward and backward 'counts' (e.g. 5-6, 4-3). This counting bias is interpreted as the consequence of an interference by overlearned tendencies to arrange numbers according to their natural order. Inhibition of such well-learned routines is known to rely on frontal lobe functioning. We examined differential effects of slow (1 Hz) and fast (10 Hz) repetitive transcranial magnetic stimulation (rTMS) over the left or right dorsolateral prefrontal cortex (DLPFC) on random number generation (RNG) performance. Eighteen healthy men performed an RNG task. Those subjects stimulated over the left DLPFC showed a frequency-dependent rTMS effect: counting bias was significantly reduced after the 1 Hz stimulation compared with baseline, but significantly exaggerated after the 10 Hz stimulation compared with 1 Hz stimulation. In contrast, the sequences of the subjects stimulated over the right DLPFC showed the well-known excess of counting in all conditions (i.e. baseline, 1 Hz and 10 Hz). These findings confirm the functional importance of specifically the left DLPFC in sequential response production and show, for the first time, that rTMS affects cognitive processing in a frequency-dependent manner.
Resumo:
This study analyzed the influence of the occupational context on the conceptualization of career satisfaction measured by the career satisfaction scale (CSS). In a large sample of N ¼ 729 highly educated professionals, a cross-occupational (i.e., physicians, economists, engineers, and teachers) measurement invariance analysis showed that the CSS was conceptualized according to occupational group membership, that is, 4 of the 5 items of the scale showed measurement noninvariance. More specifically, the relative importance, the response biases, and the reliabilities associated with different career satisfaction content domains measured by the CSS (i.e., achieved success, overall career goals, goals for advancement, goals for income, and goals for development of new skills) varied by occupational context. However, results of a comparison between manifest and latent mean differences between the occupational groups revealed that the observed measurement noninvariance did not affect the estimation of mean differences.
Resumo:
ntroduction: The ProAct study has shown that a pump switch to the Accu-Chek® Combo system (Roche Diagnostics Deutschland GmbH, Mannheim, Germany) in type 1 diabetes patients results in stable glycemic control with significant improvements in glycated hemoglobin (HbA1c) in patients with unsatisfactory baseline HbA1c and shorter pump usage time. Patients and Methods: In this post hoc analysis of the ProAct database, we investigated the glycemic control and glycemic variability at baseline by determination of several established parameters and scores (HbA1c, hypoglycemia frequency, J-score, Hypoglycemia and Hyperglycemia Indexes, and Index of Glycemic Control) in participants with different daily bolus and blood glucose measurement frequencies (less than four day, four or five per day, and more than five per day, in both cases). The data were derived from up to 299 patients (172 females, 127 males; age [mean±SD], 39.4±15.2 years; pump treatment duration, 7.0±5.2 years). Results: Participants with frequent glucose readings had better glycemic control than those with few readings (more than five readings per day vs. less than four readings per day: HbA1c, 7.2±1.1% vs. 8.0±0.9%; mean daily blood glucose, 151±22 mg/dL vs. 176±30 mg/dL; percentage of readings per month >300 mg/dL, 10±4% vs. 14±5%; percentage of readings in target range [80-180 mg/dL], 59% vs. 48% [P<0.05 in all cases]) and had a lower glycemic variability (J-score, 49±13 vs. 71±25 [P<0.05]; Hyperglycemia Index, 0.9±0.5 vs. 1.9±1.2 [P<0.05]; Index of Glycemic Control, 1.9±0.8 vs. 3.1±1.6 [P<0.05]; Hypoglycemia Index, 0.9±0.8 vs. 1.2±1.3 [not significant]). Frequent self-monitoring of blood glucose was associated with a higher number of bolus applications (6.1±2.2 boluses/day vs. 4.5±2.0 boluses/day [P<0.05]). Therefore, a similar but less pronounced effect on glycemic variability in favor of more daily bolus applications was observed (more than five vs. less than four bolues per day: J-score, 57±17 vs. 63±25 [not significant]; Hypoglycemia Index, 1.0±1.0 vs. 1.5±1.4 [P<0.05]; Hyperglycemia Index, 1.3±0.6 vs. 1.6±1.1 [not significant]; Index of Glycemic Control, 2.3±1.1 vs. 3.1±1.7 [P<0.05]). Conclusions: Pump users who perform frequent daily glucose readings have a better glycemic control with lower glycemic variability.
Resumo:
BACKGROUND Bacterial meningitis (BM) is an infectious disease that results in high mortality and morbidity. Despite efficacious antibiotic therapy, neurological sequelae are often observed in patients after disease. Currently, the main challenge in BM treatment is to develop adjuvant therapies that reduce the occurrence of sequelae. In recent papers published by our group, we described the associations between the single nucleotide polymorphisms (SNPs) AADAT +401C > T, APEX1 Asn148Glu, OGG1 Ser326Cys and PARP1 Val762Ala and BM. In this study, we analyzed the associations between the SNPs TNF -308G > A, TNF -857C > T, IL-8 -251A > T and BM and investigated gene-gene interactions, including the SNPs that we published previously. METHODS The study was conducted with 54 BM patients and 110 healthy volunteers (as the control group). The genotypes were investigated via primer-introduced restriction analysis-polymerase chain reaction (PIRA-PCR) or polymerase chain reaction-based restriction fragment length polymorphism (PCR-RFLP) analysis. Allelic and genotypic frequencies were also associated with cytokine and chemokine levels, as measured with the x-MAP method, and cell counts. We analyzed gene-gene interactions among SNPs using the generalized multifactor dimensionality reduction (GMDR) method. RESULTS We did not find significant association between the SNPs TNF -857C > T and IL-8 -251A > T and the disease. However, a higher frequency of the variant allele TNF -308A was observed in the control group, associated with changes in cytokine levels compared to individuals with wild type genotypes, suggesting a possible protective role. In addition, combined inter-gene interaction analysis indicated a significant association between certain genotypes and BM, mainly involving the alleles APEX1 148Glu, IL8 -251 T and AADAT +401 T. These genotypic combinations were shown to affect cyto/chemokine levels and cell counts in CSF samples from BM patients. CONCLUSIONS In conclusion, this study revealed a significant association between genetic variability and altered inflammatory responses, involving important pathways that are activated during BM. This knowledge may be useful for a better understanding of BM pathogenesis and the development of new therapeutic approaches.
Resumo:
Stratospheric ozone is of major interest as it absorbs most harmful UV radiation from the sun, allowing life on Earth. Ground-based microwave remote sensing is the only method that allows for the measurement of ozone profiles up to the mesopause, over 24 hours and under different weather conditions with high time resolution. In this paper a novel ground-based microwave radiometer is presented. It is called GROMOS-C (GRound based Ozone MOnitoring System for Campaigns), and it has been designed to measure the vertical profile of ozone distribution in the middle atmosphere by observing ozone emission spectra at a frequency of 110.836 GHz. The instrument is designed in a compact way which makes it transportable and suitable for outdoor use in campaigns, an advantageous feature that is lacking in present day ozone radiometers. It is operated through remote control. GROMOS-C is a total power radiometer which uses a pre-amplified heterodyne receiver, and a digital fast Fourier transform spectrometer for the spectral analysis. Among its main new features, the incorporation of different calibration loads stands out; this includes a noise diode and a new type of blackbody target specifically designed for this instrument, based on Peltier elements. The calibration scheme does not depend on the use of liquid nitrogen; therefore GROMOS-C can be operated at remote places with no maintenance requirements. In addition, the instrument can be switched in frequency to observe the CO line at 115 GHz. A description of the main characteristics of GROMOS-C is included in this paper, as well as the results of a first campaign at the High Altitude Research Station at Jungfraujoch (HFSJ), Switzerland. The validation is performed by comparison of the retrieved profiles against equivalent profiles from MLS (Microwave Limb Sounding) satellite data, ECMWF (European Centre for Medium-Range Weather Forecast) model data, as well as our nearby NDACC (Network for the Detection of Atmospheric Composition Change) ozone radiometer measuring at Bern.
Resumo:
OBJECTIVE Cochlear implants (CIs) have become the gold standard treatment for deafness. These neuroprosthetic devices feature a linear electrode array, surgically inserted into the cochlea, and function by directly stimulating the auditory neurons located within the spiral ganglion, bypassing lost or not-functioning hair cells. Despite their success, some limitations still remain, including poor frequency resolution and high-energy consumption. In both cases, the anatomical gap between the electrode array and the spiral ganglion neurons (SGNs) is believed to be an important limiting factor. The final goal of the study is to characterize response profiles of SGNs growing in intimate contact with an electrode array, in view of designing novel CI devices and stimulation protocols, featuring a gapless interface with auditory neurons. APPROACH We have characterized SGN responses to extracellular stimulation using multi-electrode arrays (MEAs). This setup allows, in our view, to optimize in vitro many of the limiting interface aspects between CIs and SGNs. MAIN RESULTS Early postnatal mouse SGN explants were analyzed after 6-18 days in culture. Different stimulation protocols were compared with the aim to lower the stimulation threshold and the energy needed to elicit a response. In the best case, a four-fold reduction of the energy was obtained by lengthening the biphasic stimulus from 40 μs to 160 μs. Similarly, quasi monophasic pulses were more effective than biphasic pulses and the insertion of an interphase gap moderately improved efficiency. Finally, the stimulation with an external electrode mounted on a micromanipulator showed that the energy needed to elicit a response could be reduced by a factor of five with decreasing its distance from 40 μm to 0 μm from the auditory neurons. SIGNIFICANCE This study is the first to show electrical activity of SGNs on MEAs. Our findings may help to improve stimulation by and to reduce energy consumption of CIs and thereby contribute to the development of fully implantable devices with better auditory resolution in the future.
Resumo:
Video-oculography devices are now used to quantify the vestibulo-ocular reflex (VOR) at the bedside using the head impulse test (HIT). Little is known about the impact of disruptive phenomena (e.g. corrective saccades, nystagmus, fixation losses, eye-blink artifacts) on quantitative VOR assessment in acute vertigo. This study systematically characterized the frequency, nature, and impact of artifacts on HIT VOR measures. From a prospective study of 26 patients with acute vestibular syndrome (16 vestibular neuritis, 10 stroke), we classified findings using a structured coding manual. Of 1,358 individual HIT traces, 72% had abnormal disruptive saccades, 44% had at least one artifact, and 42% were uninterpretable. Physicians using quantitative recording devices to measure head impulse VOR responses for clinical diagnosis should be aware of the potential impact of disruptive eye movements and measurement artifacts.
Resumo:
Charcoal in unlaminated sediments dated by 210Pb was analysed by the pollen-slide and thin-section methods. The results were compared with the number and area of forest fires on different spatial scales in the area around Lago di Origlio as listed in the wildfire database of southern Switzerland since AD 1920. The influx of the number of charcoal particles > 75 µm2 in pollen slides correlates well with the number of annual forest fires recorded within a distance of 20-50 km from the coring site. Hence a size-class distinction or an area measurement by image analysis may not be absolutely necessary for the reconstruction of regional fire history. A regression equation was computed and tested against an independent data set. Its use makes it possible to estimate the charcoal area influx (or concentration) from the particle number influx (or concentration). Local fires within a radius of 2 km around the coring site correlate well with the area influx of charcoal particles estimated by the thin-section method measuring the area of charcoal particles larger than 20 000 µm2 or longer than 50 µm. Pollen percentages and influx values suggest that intensive agriculture and Castanea sativa cultivation were reduced 30-40 years ago, followed by an increase of forest area and a development to more natural woodlands. The traditional Castanea sativa cultivation was characterized by a complete use of the biomass produced, so abandonment of chestnut led to an increasing accumulation of dead biomass, thereby raising the fire risk. On the other hand, the pollen record of the regional vegetation does not show any clear response to the increase of fire frequency during the last three decades in this area.
Resumo:
Introduction: Clinical reasoning is essential for the practice of medicine. In theory of development of medical expertise it is stated, that clinical reasoning starts from analytical processes namely the storage of isolated facts and the logical application of the ‘rules’ of diagnosis. Then the learners successively develop so called semantic networks and illness-scripts which finally are used in an intuitive non-analytic fashion [1], [2]. The script concordance test (SCT) is an example for assessing clinical reasoning [3]. However the aggregate scoring [3] of the SCT is recognized as problematic [4]. The SCT`s scoring leads to logical inconsistencies and is likely to reflect construct-irrelevant differences in examinees’ response styles [4]. Also the expert panel judgments might lead to an unintended error of measurement [4]. In this PhD project the following research questions will be addressed: 1. How does a format look like to assess clinical reasoning (similar to the SCT but) with multiple true-false questions or other formats with unambiguous correct answers, and by this address the above mentioned pitfalls in traditional scoring of the SCT? 2. How well does this format fulfill the Ottawa criteria for good assessment, with special regards to educational and catalytic effects [5]? Methods: 1. In a first study it shall be assessed whether designing a new format using multiple true-false items to assess clinical reasoning similar to the SCT-format is arguable in a theoretically and practically sound fashion. For this study focus groups or interviews with assessment experts and students will be undertaken. 2. In an study using focus groups and psychometric data Norcini`s and colleagues Criteria for Good Assessment [5] shall be determined for the new format in a real assessment. Furthermore the scoring method for this new format shall be optimized using real and simulated data.
Resumo:
OBJECTIVE Ocular vestibular-evoked myogenic potentials (oVEMPs) represent extraocular muscle activity in response to vestibular stimulation. The authors sought to investigate whether posture-induced increase of the intracranial pressure (ICP) modulated oVEMP frequency tuning, that is, the amplitude ratio between 500-Hz and 1000-Hz stimuli. DESIGN Ten healthy subjects were enrolled in this study. The subjects were positioned in the horizontal plane (0 degree) and in a 30-degree head-downwards position to elevate the ICP. In both positions, oVEMPs were recorded using 500-Hz and 1000-Hz air-conducted tone bursts. RESULTS When tilting the subject from the horizontal plane to the 30-degree head-down position, oVEMP amplitudes in response to 500-Hz tone bursts distinctly decreased (3.40 μV versus 2.06 μV; p < 0.001), whereas amplitudes to 1000 Hz were only slightly diminished (2.74 μV versus 2.48 μV; p = 0.251). Correspondingly, the 500/1000-Hz amplitude ratio significantly decreased when tilting the subjects from 0- to 30-degree inclination (1.59 versus 1.05; p = 0.029). Latencies were not modulated by head-down position. CONCLUSIONS Increasing ICP systematically alters oVEMPs in terms of absolute amplitudes and frequency tuning characteristics. oVEMPs are therefore in principle suited for noninvasive ICP monitoring.
Resumo:
Transient versus sustained ERK MAP kinase (MAPK) activation dynamics induce proliferation versus differentiation in response to epidermal (EGF) or nerve (NGF) growth factors in PC-12 cells. Duration of ERK activation has therefore been proposed to specify cell fate decisions. Using a biosensor to measure ERK activation dynamics in single living cells reveals that sustained EGF/NGF application leads to a heterogeneous mix of transient and sustained ERK activation dynamics in distinct cells of the population, different than the population average. EGF biases toward transient, while NGF biases toward sustained ERK activation responses. In contrast, pulsed growth factor application can repeatedly and homogeneously trigger ERK activity transients across the cell population. These datasets enable mathematical modeling to reveal salient features inherent to the MAPK network. Ultimately, this predicts pulsed growth factor stimulation regimes that can bypass the typical feedback activation to rewire the system toward cell differentiation irrespective of growth factor identity.
Resumo:
Measuring the ratio of heterophils and lymphocytes (H/L) in response to different stressors is a standard tool for assessing long-term stress in laying hens but detailed information on the reliability of measurements, measurement techniques and methods, and absolute cell counts is often lacking. Laying hens offered different sites of the nest boxes at different ages were compared in a two-treatment crossover experiment to provide detailed information on the procedure for measuring and the difficulties in the interpretation of H/L ratios in commercial conditions. H/L ratios were pen-specific and depended on the age and aviary system. There was no effect for the position of the nest. Heterophiles and lymphocytes were not correlated within individuals. Absolute cell counts differed in the number of heterophiles and lymphocytes and H/L ratios, whereas absolute leucocyte counts between individuals were similar. The reliability of the method using relative cell counts was good, yielding a correlation coefficient between double counts of r > 0.9. It was concluded that population-based reference values may not be sensitive enough to detect individual stress reactions and that the H/L ratio as an indicator of stress under commercial conditions may not be useful because of confounding factors and that other, non-invasive, measurements should be adopted.