59 resultados para FK-506
Resumo:
When drilling ice cores deeper than ∼100 m, drill liquid is required to maintain ice-core quality and to limit borehole closure. Due to high-pressure air bubbles in the ice, the ice core can crack during drilling and core retrieval, typically at 600–1200 m depth in Greenland. Ice from this 'brittle zone' can be contaminated by drill liquid as it seeps through cracks into the core. Continuous flow analysis (CFA) systems are routinely used to analyse ice for chemical impurities, so the detection of drill liquid is important for validating accurate measurements and avoiding potential instrument damage. An optical detector was constructed to identify drill liquid in CFA tubing by ultraviolet absorption spectroscopy at a wavelength of 290 nm. The set-up was successfully field-tested in the frame of the NEEM ice-core drilling project in Greenland. A total of 27 cases of drill liquid contamination were identified during the analysis of 175 m of brittle zone ice. The analyses most strongly affected by drill liquid contamination include insoluble dust particles, electrolytic conductivity, ammonium, hydrogen peroxide and sulphate. This method may also be applied to other types of drill liquid used at other drill sites.
Resumo:
BACKGROUND The role of fibrinolytic therapy in patients with intermediate-risk pulmonary embolism is controversial. METHODS In a randomized, double-blind trial, we compared tenecteplase plus heparin with placebo plus heparin in normotensive patients with intermediate-risk pulmonary embolism. Eligible patients had right ventricular dysfunction on echocardiography or computed tomography, as well as myocardial injury as indicated by a positive test for cardiac troponin I or troponin T. The primary outcome was death or hemodynamic decompensation (or collapse) within 7 days after randomization. The main safety outcomes were major extracranial bleeding and ischemic or hemorrhagic stroke within 7 days after randomization. RESULTS Of 1006 patients who underwent randomization, 1005 were included in the intention-to-treat analysis. Death or hemodynamic decompensation occurred in 13 of 506 patients (2.6%) in the tenecteplase group as compared with 28 of 499 (5.6%) in the placebo group (odds ratio, 0.44; 95% confidence interval, 0.23 to 0.87; P=0.02). Between randomization and day 7, a total of 6 patients (1.2%) in the tenecteplase group and 9 (1.8%) in the placebo group died (P=0.42). Extracranial bleeding occurred in 32 patients (6.3%) in the tenecteplase group and 6 patients (1.2%) in the placebo group (P<0.001). Stroke occurred in 12 patients (2.4%) in the tenecteplase group and was hemorrhagic in 10 patients; 1 patient (0.2%) in the placebo group had a stroke, which was hemorrhagic (P=0.003). By day 30, a total of 12 patients (2.4%) in the tenecteplase group and 16 patients (3.2%) in the placebo group had died (P=0.42). CONCLUSIONS In patients with intermediate-risk pulmonary embolism, fibrinolytic therapy prevented hemodynamic decompensation but increased the risk of major hemorrhage and stroke. (Funded by the Programme Hospitalier de Recherche Clinique in France and others; PEITHO EudraCT number, 2006-005328-18; ClinicalTrials.gov number, NCT00639743.).
Resumo:
BACKGROUND: Accurate projection of implanted subdural electrode contacts in presurgical evaluation of pharmacoresistant epilepsy cases by invasive EEG is highly relevant. Linear fusion of CT and MRI images may display the contacts in the wrong position due to brain shift effects. OBJECTIVE: A retrospective study in five patients with pharmacoresistant epilepsy was performed to evaluate whether an elastic image fusion algorithm can provide a more accurate projection of the electrode contacts on the pre-implantation MRI as compared to linear fusion. METHODS: An automated elastic image fusion algorithm (AEF), a guided elastic image fusion algorithm (GEF), and a standard linear fusion algorithm (LF) were used on preoperative MRI and post-implantation CT scans. Vertical correction of virtual contact positions, total virtual contact shift, corrections of midline shift and brain shifts due to pneumencephalus were measured. RESULTS: Both AEF and GEF worked well with all 5 cases. An average midline shift of 1.7mm (SD 1.25) was corrected to 0.4mm (SD 0.8) after AEF and to 0.0mm (SD 0) after GEF. Median virtual distances between contacts and cortical surface were corrected by a significant amount, from 2.3mm after LF to 0.0mm after AEF and GEF (p<.001). Mean total relative corrections of 3.1 mm (SD 1.85) after AEF and 3.0mm (SD 1.77) after GEF were achieved. The tested version of GEF did not achieve a satisfying virtual correction of pneumencephalus. CONCLUSION: The technique provided a clear improvement in fusion of pre- and post-implantation scans, although the accuracy is difficult to evaluate.
Resumo:
We review lattice results related to pion, kaon, D- and B-meson physics with the aim of making them easily accessible to the particle-physics community. More specifically, we report on the determination of the lightquark masses, the form factor f+(0), arising in semileptonic K → π transition at zero momentum transfer, as well as the decay-constant ratio fK / fπ of decay constants and its consequences for the CKM matrix elements Vus and Vud. Furthermore, we describe the results obtained on the lattice for some of the low-energy constants of SU(2)L × SU(2)R and SU(3)L×SU(3)R Chiral Perturbation Theory and review the determination of the BK parameter of neutral kaon mixing. The inclusion of heavy-quark quantities significantly expands the FLAG scope with respect to the previous review. Therefore, we focus here on D- and B-meson decay constants, form factors, and mixing parameters, since these are most relevant for the determination of CKM matrix elements and the global CKM unitarity-triangle fit. In addition we review the status of lattice determinations of the strong coupling constant αs.
Resumo:
OBJECTIVE To systematically review evidence on genetic risk factors for carbamazepine (CBZ)-induced hypersensitivity reactions (HSRs) and provide practice recommendations addressing the key questions: (1) Should genetic testing for HLA-B*15:02 and HLA-A*31:01 be performed in patients with an indication for CBZ therapy to reduce the occurrence of CBZ-induced HSRs? (2) Are there subgroups of patients who may benefit more from genetic testing for HLA-B*15:02 or HLA-A*31:01 compared to others? (3) How should patients with an indication for CBZ therapy be managed based on their genetic test results? METHODS A systematic literature search was performed for HLA-B*15:02 and HLA-A*31:01 and their association with CBZ-induced HSRs. Evidence was critically appraised and clinical practice recommendations were developed based on expert group consensus. RESULTS Patients carrying HLA-B*15:02 are at strongly increased risk for CBZ-induced Stevens-Johnson syndrome/toxic epidermal necrolysis (SJS/TEN) in populations where HLA-B*15:02 is common, but not CBZ-induced hypersensitivity syndrome (HSS) or maculopapular exanthema (MPE). HLA-B*15:02-positive patients with CBZ-SJS/TEN have been reported from Asian countries only, including China, Thailand, Malaysia, and India. HLA-B*15:02 is rare among Caucasians or Japanese; no HLA-B*15:02-positive patients with CBZ-SJS/TEN have been reported so far in these groups. HLA-A*31:01-positive patients are at increased risk for CBZ-induced HSS and MPE, and possibly SJS/TEN and acute generalized exanthematous pustulosis (AGEP). This association has been shown in Caucasian, Japanese, Korean, Chinese, and patients of mixed origin; however, HLA-A*31:01 is common in most ethnic groups. Not all patients carrying either risk variant develop an HSR, resulting in a relatively low positive predictive value of the genetic tests. SIGNIFICANCE This review provides the latest update on genetic markers for CBZ HSRs, clinical practice recommendations as a basis for informed decision making regarding the use of HLA-B*15:02 and HLA-A*31:01 genetic testing in patients with an indication for CBZ therapy, and identifies knowledge gaps to guide future research. A PowerPoint slide summarizing this article is available for download in the Supporting Information section here.
Resumo:
In the current study, we consider that optimal sprint start performance requires the self-control of responses. Therefore, start performance should depend on athletes' self-control strength. We assumed that momentary depletion of self-control strength (ego depletion) would either speed up or slow down the initiation of a sprint start, where an initiation that was sped up would carry the increased risk of a false start. Applying a mixed between- (depletion vs. nondepletion) and within- (before vs. after manipulation of depletion) subjects design, we tested the start reaction times of 37 sport students. We found that participants' start reaction times decelerated after finishing a depleting task, whereas it remained constant in the nondepletion condition. These results indicate that sprint start performance can be impaired by unrelated preceding actions that lower momentary self-control strength. We discuss practical implications in terms of optimizing sprint starts and related overall sprint performance.
Resumo:
OBJECTIVE To evaluate antenatal surveillance strategies and the optimal timing of delivery for monoamniotic twin pregnancies. METHODS Obstetric and perinatal outcomes were retrospectively retrieved for 193 monoamniotic twin pregnancies. Fetal and neonatal outcomes were compared between fetuses followed in an inpatient setting and those undergoing intensive outpatient follow-up from 26 to 28 weeks of gestation until planned cesarean delivery between 32 and 35 weeks of gestation. The risk of fetal death was compared with the risk of neonatal complications. RESULTS Fetal deaths occurred in 18.1% of fetuses (70/386). Two hundred ninety-five neonates from 153 pregnancies were born alive after 23 weeks of gestation. There were 17 neonatal deaths (5.8%), five of whom had major congenital anomalies. The prospective risk of a nonrespiratory neonatal complication was lower than the prospective risk of fetal death after 32 4/7 weeks of gestation (95% confidence interval 32 0/7-33 4/7). The incidence of death or a nonrespiratory neonatal complication was not significantly different between fetuses managed as outpatients (14/106 [13.2%]) or inpatients (15/142 [10.5%]; P=.55). Our statistical power to detect a difference in outcomes between these groups was low. CONCLUSIONS The in utero risk of a monoamniotic twin fetus exceeds the risk of a postnatal nonrespiratory complication at 32 4/7 weeks of gestation. If close fetal surveillance is instituted after 26-28 weeks of gestation and delivery takes place at approximately 33 weeks of gestation, the risk of fetal or neonatal death is low, no matter the surveillance setting. LEVEL OF EVIDENCE II.
Resumo:
AIMS A better understanding of pelvic floor muscle (PFM) activation and strength components is a prerequisite to get better insight in PFM contraction mechanisms and develop more specific PFM-training regimens for female stress urinary incontinence (SUI) patients. The aim of this systematic review (2012:CRD42012002547) was to evaluate and summarize existing studies investigating PFM activation and strength components influencing female continence and SUI. METHODS PubMed, EMBASE, and Cochrane databases were systematically searched for literature from January 1980 to November 2013 for cross-sectional studies comparing female SUI patients with healthy controls and intervention studies with SUI patients reporting on the association between PFM activation and strength components and urine loss. Trial characteristics, evaluated PFM components, their definitions, measurement methods, study outcomes, as well as quality measures, based on the Cochrane risk of bias tool, were independently extracted. The high heterogeneity of the retrieved data made pooling of results impossible and therefore restricted the analysis to a systematic review. RESULTS Cross-sectional studies showed group differences in favor of the continent women compared to SUI patients for PFM activation or PFM maximal strength, mean strength or sustained contraction. All intervention studies showed an improvement of PFM strength and decrease in urine loss in SUI patients after physical therapy. CONCLUSIONS Higher PFM activation and strength components influence female continence positively. This systematic review underscored the need for a standardized PFM components' terminology (similar to rehabilitation and training science), standardized test procedures and well matched diagnostic instruments. Neurourol. Urodynam. © 2014 Wiley Periodicals, Inc.