45 resultados para Endocarditis Bacteriana


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Staphylococcus lugdunensis endocarditis has been associated with an aggressive course. The aim of this study was to determine factors associated with the development of endocarditis in patients with S. lugdunensis bacteremia. METHODS: A retrospective analysis of all patients with S. lugdunensis bacteremia in three tertiary care centers in Switzerland was performed. Data regarding medical history, symptoms, and susceptibility of S. lugdunensis isolates were collected. Our results were reviewed in the context of the current literature. RESULTS: A total of 28 patients with S. lugdunensis bacteremia were identified. Of the 13 patients with endocarditis, all were community acquired. Cardiac surgery was performed in 85% of these patients; mortality was 23%, reflecting the aggressive course of this disease. In contrast, in the 15 patients without endocarditis, no complications associated with S. lugdunensis bacteremia were observed. In 73%, a probable source was identified in the form of a venous catheter or other foreign device. Only three of these episodes were community acquired. No difference was observed in susceptibility of the S. lugdunensis isolates to penicillin, which was 77% in endocarditis isolates, and 87% in isolates of bacteremia without endocarditis, respectively. CONCLUSION: S. lugdunensis bacteremia is associated with endocarditis in up to 50% of patients. Every patient with community-acquired S. lugdunensis bacteremia should be carefully examined for signs of endocarditis. Once S. lugdunensis endocarditis is diagnosed, close monitoring is essential and surgical treatment should be considered early. In the nosocomial setting, endocarditis is far less frequent, and S. lugdunensis bacteremia is usually associated with a catheter or other foreign materials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The implantation of a composite graft is the treatment of choice for patients with aortic root disease if the valve cannot be preserved and the patient is not a suitable candidate for a Ross procedure. Several years ago, the Shelhigh NR-2000C (Shelhigh, Inc, Millburn, NJ) was introduced in Europe. Being a totally biologic conduit and considering the lack of homografts, the graft seemed an ideal conduit for patients with destructive endocarditis, as well as for older patients who were not suitable candidates for oral anticoagulation. METHODS: From 2001 until 2006, the Shelhigh NR-2000C stentless valved conduit was implanted in 115 patients for various aortic root pathologies. The conduit consists of a bovine pericardial straight graft with an incorporated porcine stentless valve. Aortic root repair was performed during standard cardiopulmonary bypass and mild hypothermia in the majority of patients. Deep hypothermic circulatory arrest combined with selective antegrade cerebral perfusion was used when the repair extended into the arch. RESULTS: Seven patients with uncomplicated early outcome presented with unexpected sudden disastrous findings at the level of the aortic root, although 1-year follow-up computed tomographic scans were normal. Four of these patients underwent emergency operations because of desintegration of the graft, along with rupture of the aortic root. Retrospectively, the main findings were persistent fever or subfebrility over months and a halo-like enhancement on computed tomographic scans. Extensive microbiologic examinations were performed without finding a causative organism. CONCLUSION: The use of the Shelhigh aortic stentless conduit can no longer be advocated, and meticulous follow-up of patients in whom this device has been implanted has to be recommended.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: This study reviews our experience with the Ross procedure in infants and young children. METHODS: From September 1993 to September 2004, 52 children less than 15 years of age underwent a Ross procedure. The patients ranged in age from 4 days to 15 years old (median, 5 years). Fifteen patients (29%) were less than 2 years of age. The predominant indication for the Ross procedure was aortic stenosis. Sixteen patients underwent a Ross-Konno procedure for severe left ventricular outflow tract obstruction. Thirty-four patients had 48 previous interventions. Preoperatively, 6 patients showed severe left ventricular dysfunction, and 2 of the patients required ventilation and inotropic support. Concomitant procedures were performed in 8 patients. Three patients had a mitral valve replacement, 2 patients had a ventricular septal defect closure and an aortic arch reconstruction, 2 patients had aortic arch reconstructions, and 1 patient had resection of a coarctation and a ventricular septal defect closure. RESULTS: Patients were followed up for a median of 43 months (range, 1 to 130). Overall survival was 85% +/- 5% at 1 and 82% +/- 5% at 2, 5, and 10 years. Hospital mortality was 5 of 52 patients (9.6%). All deaths occurred in neonates or infants less than 2 months of age, who needed urgent surgery. Three patients died late of noncardiac causes. At last follow-up, all patients were classified in New York Heart Association functional class I or II. No patient had endocarditis of the autograft or the right ventricular outflow tract replacement. During the follow-up, no event of thrombembolism was observed. No patient required the insertion of a permanent pacemaker. Overall freedom from reoperation is 57% +/- 15% at 10 years. One patient required the replacement of the autograft at 6 months postoperatively. The development of mild aortic insufficiency was observed in 24 patients, and moderate aortic insufficiency in 1 patient during follow-up. Freedom from reoperation for the right ventricular outflow tract replacement is 60% +/- 15% at 10 years. CONCLUSIONS: The Ross procedure represents an attractive approach to aortic valve disease in young children. However, a high early mortality rate has to be considered when performing this procedure in neonates or infants who present in critical preoperative condition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 22-year-old man with pre-existing aortic valve disease contracted acute lactobacillus endocarditis six weeks after a dental procedure despite adequate prophylaxis. We discuss the limitations of prophylaxis for infective endocarditis in use until the end of 2008 and describe the new updated guidelines. We also explain the treatment of lactobacillus endocarditis and speculate on possible health risks of the increasing use of lactobacillus-containing dairy products, especially in immune-compromised patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Calcium pyrophosphate dihydrate (CPPD) crystal deposition disease may manifest clinically as septic fever (40 degrees C), acute pseudogout attack of knee, wrist and shoulders, or as a variety of patterns of chronic inflammatory or degenerative joint disease. The association of pseudogout with fever is less widely recognised and may lead to over-investigation, delay in appropriate treatment and disproportionate costs. We report on a 67-year-old woman with a history of recurrent episodes of fever and polyarthritis every 2 months for the last 3 years. Because of this she was hospitalised several times, finally with suspected culture-negative endocarditis, and was treated for 6 weeks with gentamicin, rifampicin and vancomycin. During this therapy the patient again developed septic fever and acute arthritis of the right wrist. Radiographs of the wrist, knee and symphysis pubis revealed prominent chondrocalcinosis and destructive arthropathy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES This study reports a series of pitfalls, premature failures and explantations of the third-generation Freedom SOLO (FS) bovine pericardial stentless valve. METHODS A total of 149 patients underwent aortic valve replacement using the FS. Follow-up was 100% complete with an average observation time of 5.5 ± 2.3 years (maximum 8.7 years) and a total of 825 patient-years. Following intraoperative documentation, all explanted valve prostheses underwent histological examination. RESULTS Freedom from structural valve deterioration (SVD) at 5, 6, 7, 8 and 9 years was 92, 88, 80, 70 and 62%, respectively. Fourteen prostheses required explantation due to valve-independent dysfunction (n = 5; i.e. thrombus formation, oversizing, aortic dilatation, endocarditis and suture dehiscence) or valve-dependent failure (acute leaflet tears, n = 4 and severe stenosis, n = 5). Thus, freedom from explantation at 5, 6, 7, 8 and 9 years was 95, 94, 91, 81 and 72%, respectively. An acute vertical tear along the non-coronary/right coronary commissure to the base occurred at a mean of 6.0 years (range 4.3-7.3 years) and affected size 25 and 27 prostheses exclusively. Four FS required explantation after a mean of 7.5 years (range 7.0-8.3 years) due to severe functional stenosis and gross calcification that included the entire aortic root. CONCLUSIONS The FS stentless valve is safe to implant and shows satisfying mid-term results in our single institution experience. Freedom from SVD and explantation decreased markedly after only 6-7 years, so that patients with FS require close observation and follow-up. Exact sizing, symmetric positioning and observing patient limitations are crucial for optimal outcome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The Sorin Freedom SOLO (FS) bovine pericardial stentless valve prosthesis is designed for supraannular, subcoronary implantation. We report our experience and results with 277 consecutively implanted FS bioprostheses. METHODS 277 patients (mean age, 74.2 ± 7.3 years; 139 (50.2%) female) underwent aortic valve replacement (AVR) with the FS stentless bioprosthesis. The hemodynamic performance was investigated with transthoracic echocardiography at discharge, 6 months later, and yearly thereafter. Follow-up was 100% complete, with an average observation time of 2.6 ± 1.7 years and a total of 697.3 patient-years. RESULTS The overall 30-day mortality was 4.3%. The mortalities for isolated AVR and combined procedures were 1.9% and 7.3%, respectively. No causes of death were valve-related. Preoperative peak (74.2 ± 23.0 mm Hg) and mean (48.6 ± 16.3 mm Hg) gradients decreased to 15.6 ± 5.4 mm Hg and 8.8 ± 3.0 mm Hg postoperatively and remained unchanged for as long as 5 years. The postoperative mean effective orifice area (EOA) for valve sizes 19, 21, 23, 25, and 27 were 1.49 ± 0.32 cm(2), 1.67 ± 0.40 cm(2), 1.92 ± 0.38 cm(2), 2.01 ± 0.42 cm(2), and 2.13 ± 0.36 cm(2), respectively. Severe prosthesis-patient mismach (PPM) was completely absent, and moderate PPM occurred in 17 patients (6.1%). In isolated AVR, 0.8% of patients with preoperative sinus rhythm required a permanent pacemaker before hospital discharge. There was 100% freedom from structural valve deterioration, 99.6 % freedom from endocarditis and reoperation, and 97.3% freedom from thromboembolism at 5 years. CONCLUSIONS The FS stentless aortic valve is safe to implant, and it shows excellent hemodynamic performance and early and midterm results. Owing to the favorable EOA, the valve appears particularly attractive for patients at risk for PPM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES To report the mid-term results of aortic root replacement using a self-assembled biological composite graft, consisting of a vascular tube graft and a stented tissue valve. METHODS Between January 2005 and December 2011, 201 consecutive patients [median age 66 (interquartile range, IQR, 55-77) years, 31 female patients (15.4%), median logistic EuroSCORE 10 (IQR 6.8-23.2)] underwent aortic root replacement using a stented tissue valve for the following indications: annulo-aortic ectasia or ascending aortic aneurysm with aortic valve disease in 162 (76.8%) patients, active infective endocarditis in 18 (9.0%) and acute aortic dissection Stanford type A in 21 (10.4%). All patients underwent clinical and echocardiographic follow-up. We analysed survival and valve-related events. RESULTS The overall in-hospital mortality rate was 4.5%. One- and 5-year cardiac-related mortality rates were 3 and 6%, and overall survival was 95 ± 1.5 and 75 ± 3.6%, respectively. The rate of freedom from structural valve failure was 99% and 97 ± 0.4% at the 1- and 5-year follow-up, respectively. The incidence rates of prosthetic valve endocarditis were 3 and 4%, respectively. During a median follow-up of 28 (IQR 14-51) months, only 2 (1%) patients required valve-related redo surgery due to prosthetic valvular endocarditis and none suffered from thromboembolic events. One percent of patients showed structural valve deterioration without any clinical symptoms; none of the patients suffered greater than mild aortic regurgitation. CONCLUSIONS Aortic root replacement using a self-assembled biological composite graft is an interesting option. Haemodynamic results are excellent, with freedom from structured valve failure. Need for reoperation is extremely low, but long-term results are necessary to prove the durability of this concept.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE Sutureless valves are designed to facilitate surgical implantation, including less-invasive techniques in aortic valve replacement, by maintaining surgical precision of implantation compared with transcatheter techniques. Long-term clinical experience with sutureless valves is lacking. We report the 5-year follow-up results of an international, prospective, multicenter study evaluating the clinical performance and safety of the 3f Enable valve (Medtronic Inc, Minneapolis, Minn). METHODS Between March 2007 and December 2009, 141 patients (54 male; mean age, 76.1±5.7 years) undergoing aortic valve replacement with the 3f Enable valve were enrolled in 10 European sites. The mean follow-up was 2.76 years (range, 2 days to 5.1 years; total, 388.7 patient-years). Echocardiographic valvular hemodynamic and morphologic analyses were performed by an independent core laboratory. RESULTS The mean systolic gradient was 10.4±4.4 mm Hg at discharge and 7.7±4.1 mm Hg at 5 years. The mean effective orifice area was 1.7±0.5 cm2 at discharge and 1.6±0.2 cm2 at 5 years. Freedom from all-cause and valve-related mortality was 87.6%±2.9% and 96.8%±1.6% at 1 year (113 patients at risk) and 77.0%±7.5% and 93.8%±4.8% at 5 years (24 patients at risk), respectively. Six patients underwent reoperation (4 because of major paravalvular leakage and 2 because of endocarditis). Freedom from reoperation was 95.4%±1.9% at 1 year and 95.4%±6.1% at 5 years. No structural valve deterioration occurred during the follow-up period. CONCLUSIONS The sutureless 3f Enable valve represents a safe and effective treatment for aortic valve stenosis, providing an excellent hemodynamic profile. This study represents the longest follow-up study for a sutureless bioprosthesis. Sutureless valves may become an option for all patients with indicated biological aortic valve replacement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The rapid further development of computed tomography (CT) and magnetic resonance imaging (MRI) induced the idea to use these techniques for postmortem documentation of forensic findings. Until now, only a few institutes of forensic medicine have acquired experience in postmortem cross-sectional imaging. Protocols, image interpretation and visualization have to be adapted to the postmortem conditions. Especially, postmortem alterations, such as putrefaction and livores, different temperature of the corpse and the loss of the circulation are a challenge for the imaging process and interpretation. Advantages of postmortem imaging are the higher exposure and resolution available in CT when there is no concern for biologic effects of ionizing radiation, and the lack of cardiac motion artifacts during scanning. CT and MRI may become useful tools for postmortem documentation in forensic medicine. In Bern, 80 human corpses underwent postmortem imaging by CT and MRI prior to traditional autopsy until the month of August 2003. Here, we describe the imaging appearance of postmortem alterations--internal livores, putrefaction, postmortem clotting--and distinguish them from the forensic findings of the heart, such as calcification, endocarditis, myocardial infarction, myocardial scarring, injury and other morphological alterations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES Long-term follow-up reports after implantation of the Shelhigh® (Shelhigh, Inc., NJ, USA) No-React® aortic valved conduit used for aortic root replacement do not exist. METHODS Between November 1998 and December 2007, the Shelhigh® No-React® aortic valved conduit was implanted in 291 consecutive patients with a mean age of 69.6 ± 9.1 years, and 33.7% were female (n = 98). Indications were annulo-aortic ectasia (n = 202), aortic valve stenosis combined with ascending aortic aneurysm (n = 67), acute type A aortic dissection (n = 29), endocarditis (n = 26) and other related pathologies (n = 48) including 62 patients with previous cardiac surgery. Data from two cardiac institutions were analysed retrospectively using SPSS (SPSS Software IBM, Inc., 2014, NY, USA). RESULTS Operative mortality was 10% (n = 29). Main cause of death was cardiac failure in 15 patients (51.8%), neurological events in 6 patients (20.7%), respiratory failure in 4 patients (13.8%), bleeding complications in 2 patients (6.9%) and gastrointestinal ischaemia in 2 cases (6.9%). There were 262 hospital survivors and all were entered in the follow-up study (100% complete). During the long-term follow-up (mean 70.3 ± 53.1 in months), a total of 126/262 patients (44.3%) died. Main causes of death in patients after discharge were cardiac (n = 37, 14.1%), neurological (n = 15, 5.7%) respiratory (n = 12, 4.6%), endocarditis (n = 12, 4.6%) and peripheral vascular disease (n = 5, 1.9%). In 29 (11.1%) patients, the cause of death could not be determined. Reoperation was required in 25 (8.6%) patients due to infection of the conduit (n = 9), aortoventricular disconnection (n = 4), pseudoaneurysm formation (n = 4) and structural valve degeneration (n = 8). Reoperations were performed 5.0 ± 3.8 (range 0.1-11.7) years after index surgery. CONCLUSIONS The Shelhigh® No-React® aortic valved conduit showed satisfactory short-term operative results. However, the long-term follow-up revealed a relatively high rate of deaths, which may be explained by the epidemiology of the patient group, but a substantial proportion of deaths could not be clarified. The overall rate of reoperation (8.6%) during the mid-term follow-up is worrisome and the failures due to aortoventricular disconnection, endocarditis and pseudoaneurysm formation remain unexplained. The redo-procedures were technically demanding. We recommend close follow-up of patients with the Shelhigh® No-React® aortic valved conduit, because besides classical structural valve degeneration, unexpected findings may be observed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES The aim of the Cavalier trial was to evaluate the safety and performance of the Perceval sutureless aortic valve in patients undergoing aortic valve replacement (AVR). We report the 30-day clinical and haemodynamic outcomes from the largest study cohort with a sutureless valve. METHODS From February 2010 to September 2013, 658 consecutive patients (mean age 77.8 years; 64.4% females; mean logistic EuroSCORE 10.2%) underwent AVR in 25 European Centres. Isolated AVRs were performed in 451 (68.5%) patients with a less invasive approach in 219 (33.3%) cases. Of the total, 40.0% were octogenarians. Congenital bicuspid aortic valve was considered an exclusion criterion. RESULTS Implantation was successful in 628 patients (95.4%). In isolated AVR through sternotomy, the mean cross-clamp time and the cardiopulmonary bypass (CPB) time were 32.6 and 53.7 min, and with the less invasive approach 38.8 and 64.5 min, respectively. The 30-day overall and valve-related mortality rates were 3.7 and 0.5%, respectively. Valve explants, stroke and endocarditis occurred in 0.6, 2.1 and in 0.1% of cases, respectively. Preoperative mean and peak pressure gradients decreased from 44.8 and 73.24 mmHg to 10.24 and 19.27 mmHg at discharge, respectively. The mean effective orifice area improved from 0.72 to 1.46 cm(2). CONCLUSIONS The current 30-day results show that the Perceval valve is safe (favourable haemodynamic effect and low complication rate), and can be implanted with a fast and reproducible technique after a short learning period. Short cross-clamp and CPB times were achieved in both isolated and combined procedures. The Perceval valve represents a promising alternative to biological AVR, especially with a less invasive approach and in older patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gebiet: Chirurgie Abstract: Objectives This study reports a series of pitfalls, premature failures and explantations of the third generation Freedom SOLO bovine pericardial stentless valve. – – Methods 149 patients underwent aortic valve replacement (AVR) using the FS. Follow-up was 100% complete with an average observation time of 5.5±2.3 years (max. 8.7 years) and a total of 825 patient years. Following intraoperative documentation, all explanted valve prostheses underwent histological examination. – – Results Freedom from structural valve deterioration (SVD) at 5, 6, 7, 8 and 9 years was 92%, 88%, 80% and 70% and 62%, respectively. 14 prostheses required explantation due to valve-independent dysfunction (n=5, i.e. thrombus formation, oversizing, aortic dilatation, endocarditis and suture dehiscence) or valve-dependent failure (acute leaflet tears, n=4, severe stenosis, n=5). Thus freedom from explantation at 5, 6, 7, 8 and 9 years was 95%, 94%, 91% and 81% and 72%, respectively. An acute vertical tear along the non-coronary/right-coronary commissure to the base occurred at a mean of 6.0 years [range 4.3?7.3 years] and affected size 25 and 27 prostheses exclusively. Four FS required explantation after a mean of 7.5 years [range 7.0?8.3 years] due to severe functional stenosis and gross calcification that included the entire aortic root. – – Conclusions The Freedom SOLO stentless valve is safe to implant and shows satisfying mid-term results in our single institution experience. Freedom from SVD and explantation decreased markedly after only 6 ? 7 years, so that patients with FS require close observation and follow-up. Exact sizing, symmetric positioning and observing patient limitations are crucial for optimal outcome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE Sutureless aortic valve replacement (AVR) offers an alternative to standard AVR in aortic stenosis. This prospective, single-arm study aimed to demonstrate safety and effectiveness of a bovine pericardial sutureless aortic valve at 1 year. METHODS From February 2010 to September 2013, 658 patients (mean age 78.3 ± 5.6 years; 40.0% octogenarian; 64.4% female; mean Society of Thoracic Surgeons score 7.2 ± 7.4) underwent sutureless AVR in 25 European centers. Concomitant cardiac procedures were performed in 29.5% and minimally invasive cardiac surgery in 33.3%. RESULTS One-year site-reported event rates were 8.1% for all-cause mortality, 4.5% for cardiac mortality, 3.0% for stroke, 1.9% for valve-related reoperation, 1.4% for endocarditis, and 0.6% for major paravalvular leak. No valve thrombosis, migration, or structural valve deterioration occurred. New York Heart Association class improved at least 1 level in 77.5% and remained stable (70.4% New York Heart Association class I or II at 1 year). Mean effective orifice area was 1.5 ± 0.4 cm(2); pressure gradient was 9.2 ± 5.0 mm Hg. Left ventricular mass decreased from 138.5 g/m(2) before surgery to 115.3 g/m(2) at 1 year (P < .001). Echocardiographic core laboratory findings confirmed that paravalvular leak was rare and remained stable during follow-up. CONCLUSIONS The Perceval sutureless valve resulted in low 1-year event rates in intermediate-risk patients undergoing AVR. New York Heart Association class improved in more than three-quarters of patients and remained stable. These data support the safety and efficacy to 1 year of the Perceval sutureless valve in this intermediate-risk population.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die Chance, mit einem angeborenen Herzfehler erwachsen zu werden, liegt mittlerweile bei über 90 %. Trotz aller Erfolge der Medizin können Herzfehler auch nach erfolgreicher Korrektur nicht als geheilt betrachtet werden. Langzeitkomplikationen im Sinn von Herzrhythmusstörungen, Herzinsuffizienz, embolischen Ereignissen, Endokarditis, oder Reoperationen aufgrund residualer Befunde oder Klappendegenerationen sind häufig. Aus diesem Grund wird für eine Vielzahl angeborener Herzfehler eine lebenslange spezialisierte Betreuung empfohlen. Jugendliche mit Herzfehlern müssen darauf vorbereitet werden, im Erwachsenenalter Eigenverantwortung zu übernehmen. Dazu ist eine strukturierte Transition ein entscheidender Vorteil. Dadurch werden einerseits Jugendliche selbst auf ihre Erwachsenenrolle vorbereitet und andererseits kann ein adäquater Transfer der Betreuung vom Kinder- zum Erwachsenenmediziner gewährleistet werden. Jugendliche ohne Transfer und ohne spezialisierte Betreuung im Erwachsenenalter haben ein erhöhtes Risiko, kardiovaskuläre Komplikationen zu erleiden. Es wurde gezeigt, dass die Mortalität bei angeborenen Herzfehlern bei Erwachsenen mit spezialisierter Betreuung geringer ist als bei Patienten ohne entsprechende Betreuung. Am Beispiel des Zentrums für angeborene Herzfehler in Bern wird aufgezeigt, wie eine pflegegeleitete Transitionssprechstunde aufgebaut und erfolgreich umgesetzt werden kann.