74 resultados para Doppler Shift
Resumo:
PURPOSE: In this study we examined the arterial-adaptive dilatation and Doppler velocimetry, especially RI values, in normal fetuses with a single umbilical artery (SUA). MATERIALS AND METHODS: We studied 195 fetuses from 18 to 39 weeks of gestational age with a prenatally identified SUA retrospectively. They were enrolled in this study if the following information applied: > 18 weeks of gestational age, no structural or chromosomal abnormalities, and histopathological confirmation of SUA. Sonographic examination included evaluation of the umbilical artery resistance and the cross-sectional area of the umbilical cord, and its vessels were measured in all cases. Small for gestational age (SGA) was diagnosed when the birth weight was below the 10th percentile for gestational age. Fetuses with intrauterine growth restriction were defined as those with biometric data below the 5th percentile. RESULTS: There were 119 cases of prenatally identified SUA which met the inclusion criteria. RI values were below the 10th percentile in 33/119 (27.33) and below the 50th percentile in 73/119 (61.33). RI values below the 10th percentile were significantly more likely to be in the normal collective than in the growth restricted collective [31/87 (35.63%) vs. 2/32 (6.25%); p = 0.001]. Even more significant differences became apparent when comparing the RI values below the 50th percentile of both groups. An umbilical artery diameter over the 90th percentile was found in 49 (41.9%) of cases and was significantly more likely to be present in normal growing fetuses than in the growth restricted group. CONCLUSION: Normal fetuses with SUA are at higher risk to be born as SGA. With our study results we can confirm the hypothesis that Doppler flow measurements and arterial diameter in SUA are different from those found in normal fetal umbilical arteries. RI values over the 50th percentile or a cross-sectional area of the artery below 95th percentile after 26th week of gestation significantly increases the risk of SGA.
Resumo:
Cord entanglement affects the majority of monoamniotic (MA) twins, accounting for the high proportion of intrauterine deaths of MA twins, and it is often present from early gestation. 3D ultrasound can be used to acquire volume data comprising information on umbilical colour Doppler flow, providing a very graphic depiction of cord entanglement. We have used 2D, "conventional" and a novel 3D display of colour Doppler ultrasound showing cord entanglement.
Resumo:
QUESTION UNDER STUDY: Purpose was to validate accuracy and reliability of automated oscillometric ankle-brachial (ABI) measurement prospectively against the current gold standard of Doppler-assisted ABI determination. METHODS: Oscillometric ABI was measured in 50 consecutive patients with peripheral arterial disease (n = 100 limbs, mean age 65 +/- 6 years, 31 men, 19 diabetics) after both high and low ABI had been determined conventionally by Doppler under standardised conditions. Correlation was assessed by linear regression and Pearson product moment correlation. Degree of inter-modality agreement was quantified by use of Bland and Altman method. RESULTS: Oscillometry was performed significantly faster than Doppler-assisted ABI (3.9 +/- 1.3 vs 11.4 +/- 3.8 minutes, P <0.001). Mean readings were 0.62 +/- 0.25, 0.70 +/- 0.22 and 0.63 +/- 0.39 for low, high and oscillometric ABI, respectively. Correlation between oscillometry and Doppler ABI was good overall (r = 0.76 for both low and high ABI) and excellent in oligo-symptomatic, non-diabetic patients (r = 0.81; 0.07 +/- 0.23); it was, however, limited in diabetic patients and in patients with critical limb ischaemia. In general, oscillometric ABI readings were slightly higher (+0.06), but linear regression analysis showed that correlation was sustained over the whole range of measurements. CONCLUSIONS: Results of automated oscillometric ABI determination correlated well with Doppler-assisted measurements and could be obtained in shorter time. Agreement was particularly high in oligo-symptomatic non-diabetic patients.
Resumo:
The identification and accurate location of centers of brain activity are vital both in neuro-surgery and brain research. This study aimed to provide a non-invasive, non-contact, accurate, rapid and user-friendly means of producing functional images intraoperatively. To this end a full field Laser Doppler imager was developed and integrated within the surgical microscope and perfusion images of the cortical surface were acquired during awake surgery whilst the patient performed a predetermined task. The regions of brain activity showed a clear signal (10-20% with respect to the baseline) related to the stimulation protocol which lead to intraoperative functional brain maps of strong statistical significance and which correlate well with the preoperative fMRI and intraoperative cortical electro-stimulation. These initial results achieved with a prototype device and wavelet based regressor analysis (the hemodynamic response function being derived from MRI applications) demonstrate the feasibility of LDI as an appropriate technique for intraoperative functional brain imaging.
Resumo:
Doppler Optical Coherence Tomography (DOCT) is a biomedical imaging technique that allows simultaneous structural imaging and flow monitoring inside biological tissues and materials with spatial resolution in the micrometer scale. It has recently been applied to the characterization of microfluidic systems. Structural and flow imaging of novel microfluidics platforms for cytotoxicologic applications were obtained with a real-time, Near Infrared Spectral Domain DOCT system. Characteristics such as flow homogeneity in the chamber, which is one of the most important parameters for cell culture, are investigated. OCT and DOCT images were used to monitor flow inside a specific platform that is based on microchannel division for a better flow homogeneity. In particular, the evolution of flow profile at the transition between the microchannel structure and the chamber is studied.
Resumo:
OBJECTIVES: (1) To assess spinal cord blood flow (SCBF) during surgical treatment of disk extrusion in dogs and (2) to investigate associations between SCBF, clinical signs, presurgical MRI images, and 24-hour surgical outcome. STUDY DESIGN: Cohort study. ANIMALS: Chondrodystrophic dogs with thoracolumbar disk extrusion (n=12). METHODS: Diagnosis was based on clinical signs and MRI findings, and confirmed at surgery. Regional SCBF was measured intraoperatively by laser-Doppler flowmetry before, immediately after surgical spinal cord decompression, and after 15 minutes of lavaging the lesion. Care was taken to ensure a standardized surgical procedure to minimize factors that could influence measurement readings. RESULTS: A significant increase in intraoperative SCBF was found in all dogs (Wilcoxon's signed-rank test; P=.05) immediately after spinal cord decompression and after 15 minutes. Changes in SCBF were not associated with duration of clinical signs; initial or 24-hour neurologic status; or degree of spinal cord compression assessed by MRI. CONCLUSION: SCBF increases immediately after spinal cord decompression in dogs with disk herniation; however, increased SCBF was not associated with a diminished 24-hour neurologic status. CLINICAL RELEVANCE: An increase in SCBF does not appear to be either associated with the degree of spinal cord compression or of a magnitude sufficient to outweigh the benefit of surgical decompression by resulting in clinically relevant changes in 24-hour outcome.
Resumo:
PURPOSE To evaluate the biologic width dimensions around implants with nonmatching implant-abutment diameters. MATERIALS AND METHODS Five canines had their mandibular premolars and first molars removed bilaterally and replaced with 12 implants that had nonmatching implant-abutment diameters. On one side, six implants were placed in a submerged surgical approach, and the other side utilized a nonsubmerged approach. Two of the implants on each side were placed either 1 mm above, even with, or 1 mm below the alveolar crest. Two months later, gold crowns were attached, and the dogs were sacrificed 6 months postloading. Block sections were processed for histologic and histomorphometric analyses. RESULTS The bone level, connective tissue length, epithelial dimension, and biologic width were not significantly different when the implants were initially placed in a submerged or nonsubmerged surgical approach. The bone level was significantly different around implants placed 1 mm above the crest compared to implants placed even with or 1 mm below the alveolar crest. The connective tissue dimension was not different for any implant level placement. The epithelial dimension and biologic width were significantly greater for implants placed 1 mm below the alveolar crest compared to implants placed even with or 1 mm above the alveolar crest. For five of six implant placements, connective tissue covered the implant/abutment interface. CONCLUSIONS This study reveals a fundamental change in the biologic response to implants with nonmatching implant-abutment diameters. Unlike implants with matching implant-abutment diameters, the connective tissue extended coronally past the interface (microgap). This morphologic tissue alteration represents a significant change in the biologic reaction to implant-abutment interfaces and suggests that marginal inflammation is eliminated or greatly reduced in these implant designs.
Resumo:
In the past few years indications for the use of the air polishing technology have been expanded from supragingival use (airflow) to subgingival air polishing (perioflow) by the development of new low-abrasive glycine-based powders and devices with a subgingival nozzle. Several studies on the subgingival use of air polishing have been completed. On 7 June 2012, during the Europerio 7 Congress in Vienna, a consensus conference on mechanical biofilm management took place aiming to review the current evidence from the literature on the clinical relevance of the subgingival use of air polishing and to make practical recommendations for the clinician. Bernita Bush (Bern), Prof Johannes Einwag (Stuttgart), Prof Thomas Flemmig (Seattle), Carmen Lanoway (Munich), Prof Ursula Platzer (Hamburg), Prof Petra Schmage (Hamburg), Brigitte Schoeneich (Zurich), Prof Anton Sculean (Bern), Dr Clemens Walter (Basel), and Prof Jan Wennström (Gothenburg) discussed under the moderation of Klaus-Dieter Bastendorf and Christian Becker (both ADIC Association for Dental Infection Control) the available clinical studies to reach a consensus on available clinical evidence. This paper summarizes the main conclusions of the consensus conference and points to the clinical relevance of the findings for the dental practitioner.
Resumo:
BACKGROUND In 2007, leading international experts in the field of inflammatory bowel disease (IBD) recommended intravenous (IV) iron supplements over oral (PO) ones because of superior effectiveness and better tolerance. We aimed to determine the percentage of patients with IBD undergoing iron therapy and to assess the dynamics of iron prescription habits (IV versus PO). METHODS We analyzed anonymized data on patients with Crohn's disease and ulcerative colitis extracted from the Helsana database. Helsana is a Swiss health insurance company providing coverage for 18% of the Swiss population (1.2 million individuals). RESULTS In total, 629 patients with Crohn's disease (61% female) and 398 patients with ulcerative colitis (57% female) were identified; mean observation time was 31.8 months for Crohn's disease and 31.0 months for ulcerative colitis patients. Of all patients with IBD, 27.1% were prescribed iron (21.1% in males; 31.1% in females). Patients treated with steroids, immunomodulators, and/or anti-tumor necrosis factor drugs were more frequently treated with iron supplements when compared with those not treated with any medications (35.0% versus 20.9%, odds ratio, 1.94; P < 0.001). The frequency of IV iron prescriptions increased significantly from 2006 to 2009 for both genders (males: from 2.6% to 10.1%, odds ratio = 3.84, P < 0.001; females: from 5.3% to 12.1%, odds ratio = 2.26, P = 0.002), whereas the percentage of PO iron prescriptions did not change. CONCLUSIONS Twenty-seven percent of patients with IBD were treated with iron supplements. Iron supplements administered IV were prescribed more frequently over time. These prescription habits are consistent with the implementation of guidelines on the management of iron deficiency in IBD.