60 resultados para Design and analyses
Resumo:
OBJECTIVES Optical scanners combined with computer-aided design and computer-aided manufacturing (CAD/CAM) technology provide high accuracy in the fabrication of titanium (TIT) and zirconium dioxide (ZrO) bars. The aim of this study was to compare the precision of fit of CAD/CAM TIT bars produced with a photogrammetric and a laser scanner. METHODS Twenty rigid CAD/CAM bars were fabricated on one single edentulous master cast with 6 implants in the positions of the second premolars, canines and central incisors. A photogrammetric scanner (P) provided digitized data for TIT-P (n=5) while a laser scanner (L) was used for TIT-L (n=5). The control groups consisted of soldered gold bars (gold, n=5) and ZrO-P with similar bar design. Median vertical distance between implant and bar platforms from non-tightened implants (one-screw test) was calculated from mesial, buccal and distal scanning electron microscope measurements. RESULTS Vertical microgaps were not significantly different between TIT-P (median 16μm; 95% CI 10-27μm) and TIT-L (25μm; 13-32μm). Gold (49μm; 12-69μm) had higher values than TIT-P (p=0.001) and TIT-L (p=0.008), while ZrO-P (35μm; 17-55μm) exhibited higher values than TIT-P (p=0.023). Misfit values increased in all groups from implant position 23 (3 units) to 15 (10 units), while in gold and TIT-P values decreased from implant 11 toward the most distal implant 15. SIGNIFICANCE CAD/CAM titanium bars showed high precision of fit using photogrammetric and laser scanners. In comparison, the misfit of ZrO bars (CAM/CAM, photogrammetric scanner) and soldered gold bars was statistically higher but values were clinically acceptable.
Resumo:
The Liquid Argon Time Projection Chamber (LArTPC) is a prime type of detector for future large-mass neutrino observatories and proton decay searches. In this paper we present the design and operation, as well as experimental results from ARGONTUBE, a LArTPC being operated at the AEC-LHEP, University of Bern. The main goal of this detector is to prove the feasibility of charge drift over very long distances in liquid argon. Many other aspects of the LArTPC technology are also investigated, such as a voltage multiplier to generate high voltage in liquid argon (Greinacher circuit), a cryogenic purification system and the application of multi-photon ionization of liquid argon by a UV laser. For the first time, tracks induced by cosmic muons and UVlaser beam pulses have been observed and studied at drift distances of up to 5 m, the longest reached to date.
Resumo:
Most medical implants run on batteries, which require costly and tedious replacement or recharging. It is believed that micro-generators utilizing intracorporeal energy could solve these problems. However, such generators do not, at this time, meet the energy requirements of medical implants.This paper highlights some essential aspects of designing and implementing a power source that scavenges energy from arterial expansion and contraction to operate an implanted medical device. After evaluating various potentially viable transduction mechanisms, the fabricated prototype employs an electromagnetic transduction mechanism. The artery is inserted into a laboratory-fabricated flexible coil which is permitted to freely deform in a magnetic field. This work also investigates the effects of the arterial wall's material properties on energy harvesting potential. For that purpose, two types of arteries (Penrose X-ray tube, which behave elastically, and an artery of a Göttinger minipig, which behaves viscoelastically) were tested. No noticeable difference could be observed between these two cases. For the pig artery, average harvestable power was 42 nW. Moreover, peak power was 2.38 μW. Both values are higher than those of the current state of the art (6 nW/16 nW). A theoretical modelling of the prototype was developed and compared to the experimental results.
Resumo:
OBJECTIVE The cost-effectiveness of cast nonprecious frameworks has increased their prevalence in cemented implant crowns. The purpose of this study was to assess the effect of the design and height of the retentive component of a standard titanium implant abutment on the fit, possible horizontal rotation and retention forces of cast nonprecious alloy crowns prior to cementation. MATERIALS AND METHODS Two abutment designs were examined: Type A with a 6° taper and 8 antirotation planes (Straumann Tissue-Level RN) and Type B with a 7.5° taper and 1 antirotation plane (SICace implant). Both types were analyzed using 60 crowns: 20 with a full abutment height (6 mm), 20 with a medium abutment height (4 mm), and 20 with a minimal (2.5 mm) abutment height. The marginal and internal fit and the degree of possible rotation were evaluated by using polyvinylsiloxane impressions under a light microscope (magnification of ×50). To measure the retention force, a custom force-measuring device was employed. STATISTICAL ANALYSIS one-sided Wilcoxon rank-sum tests with Bonferroni-Holm corrections, Fisher's exact tests, and Spearman's rank correlation coefficient. RESULTS Type A exhibited increased marginal gaps (primary end-point: 55 ± 20 μm vs. 138 ± 59 μm, P < 0.001) but less rotation (P < 0.001) than Type B. The internal fit was also better for Type A than for Type B (P < 0.001). The retention force of Type A (2.49 ± 3.2 N) was higher (P = 0.019) than that of Type B (1.27 ± 0.84 N). Reduction in abutment height did not affect the variables observed. CONCLUSION Less-tapered abutments with more antirotation planes provide an increase in the retention force, which confines the horizontal rotation but widens the marginal gaps of the crowns. Thus, casting of nonprecious crowns with Type A abutments may result in clinically unfavorable marginal gaps.
Resumo:
In order to harness the unique properties of nanoparticles for novel clinical applications and to modulate their uptake into specific immune cells we designed a new library of homo- and hetero-functional fluorescence-encoded gold nanoparticles (Au-NPs) using different poly(vinyl alcohol) and poly(ethylene glycol)-based polymers for particle coating and stabilization. The encoded particles were fully characterized by UV-Vis and fluorescence spectroscopy, zeta potential and dynamic light scattering. The uptake by human monocyte derived dendritic cells in vitro was studied by confocal laser scanning microscopy and quantified by fluorescence-activated cell sorting and inductively coupled plasma atomic emission spectroscopy. We show how the chemical modification of particle surfaces, for instance by attaching fluorescent dyes, can conceal fundamental particle properties and modulate cellular uptake. In order to mask the influence of fluorescent dyes on cellular uptake while still exploiting its fluorescence for detection, we have created hetero-functionalized Au-NPs, which again show typical particle dependent cellular interactions. Our study clearly prove that the thorough characterization of nanoparticles at each modification step in the engineering process is absolutely essential and that it can be necessary to make substantial adjustments of the particles in order to obtain reliable cellular uptake data, which truly reflects particle properties.
Resumo:
This thesis consists of four essays on the design and disclosure of compensation contracts. Essays 1, 2 and 3 focus on behavioral aspects of mandatory compensation disclosure rules and of contract negotiations in agency relationships. The three experimental studies develop psychology- based theory and present results that deviate from standard economic predictions. Furthermore, the results of Essay 1 and 2 also have implications for firms’ discretion in how to communicate their top management’s incentives to the capital market. Essay 4 analyzes the role of fairness perceptions for the evaluation of executive compensation. For this purpose, two surveys targeting representative eligible voters as well as investment professionals were conducted. Essay 1 investigates the role of the detailed ‘Compensation Discussion and Analysis’, which is part of the Security and Exchange Commission’s 2006 regulation, on investors’ evaluations of executive performance. Compensation disclosure complying with this regulation clarifies the relationship between realized reported compensation and the underlying performance measures and their target achievement levels. The experimental findings suggest that the salient presentation of executives’ incentives inherent in the ‘Compensation Discussion and Analysis’ makes investors’ performance evaluations less outcome dependent. Therefore, investors’ judgment and investment decisions might be less affected by noisy environmental factors that drive financial performance. The results also suggest that fairness perceptions of compensation contracts are essential for investors’ performance evaluations in that more transparent disclosure increases the perceived fairness of compensation and the performance evaluation of managers who are not responsible for a bad financial performance. These results have important practical implications as firms might choose to communicate their top management’s incentive compensation more transparently in order to benefit from less volatile expectations about their future performance. Similar to the first experiment, the experiment described in Essay 2 addresses the question of more transparent compensation disclosure. However, other than the first experiment, the second experiment does not analyze the effect of a more salient presentation of contract information but the informational effect of contract information itself. For this purpose, the experiment tests two conditions in which the assessment of the compensation contracts’ incentive compatibility, which determines executive effort, is either possible or not. On the one hand, the results suggest that the quality of investors’ expectations about executive effort is improved, but on the other hand investors might over-adjust their prior expectations about executive effort if being confronted with an unexpected financial performance and under-adjust if the financial performance confirms their prior expectations. Therefore, in the experiment, more transparent compensation disclosure does not lead to more correct overall judgments of executive effort and to even lower processing quality of outcome information. These results add to the literature on disclosure which predominantly advocates more transparency. The findings of the experiment however, identify decreased information processing quality as a relevant disclosure cost category. Firms might therefore carefully evaluate the additional costs and benefits of more transparent compensation disclosure. Together with the results from the experiment in Essay 1, the two experiments on compensation disclosure imply that firms should rather focus on their discretion how to present their compensation disclosure to benefit from investors’ improved fairness perceptions and their spill-over on performance evaluation. Essay 3 studies the behavioral effects of contextual factors in recruitment processes that do not affect the employer’s or the applicant’s bargaining power from a standard economic perspective. In particular, the experiment studies two common characteristics of recruitment processes: Pre-contractual competition among job applicants and job applicants’ non-binding effort announcements as they might be made during job interviews. Despite the standard economic irrelevance of these factors, the experiment develops theory regarding the behavioral effects on employees’ subsequent effort provision and the employers’ contract design choices. The experimental findings largely support the predictions. More specifically, the results suggest that firms can benefit from increased effort and, therefore, may generate higher profits. Further, firms may seize a larger share of the employment relationship’s profit by highlighting the competitive aspects of the recruitment process and by requiring applicants to make announcements about their future effort. Finally, Essay 4 studies the role of fairness perceptions for the public evaluation of executive compensation. Although economic criteria for the design of incentive compensation generally do not make restrictive recommendations with regard to the amount of compensation, fairness perceptions might be relevant from the perspective of firms and standard setters. This is because behavioral theory has identified fairness as an important determinant of individuals’ judgment and decisions. However, although fairness concerns about executive compensation are often stated in the popular media and even in the literature, evidence on the meaning of fairness in the context of executive compensation is scarce and ambiguous. In order to inform practitioners and standard setters whether fairness concerns are exclusive to non-professionals or relevant for investment professionals as well, the two surveys presented in Essay 4 aim to find commonalities in the opinions of representative eligible voters and investments professionals. The results suggest that fairness is an important criterion for both groups. Especially, exposure to risk in the form of the variable compensation share is an important criterion shared by both groups. The higher the assumed variable share, the higher is the compensation amount to be perceived as fair. However, to a large extent, opinions on executive compensation depend on personality characteristics, and to some extent, investment professionals’ perceptions deviate systematically from those of non-professionals. The findings imply that firms might benefit from emphasizing the riskiness of their managers’ variable pay components and, therefore, the findings are also in line with those of Essay 1.
Resumo:
The scientific literature of laboratory animal research is replete with papers reporting poor reproducibility of results as well as failure to translate results to clinical trials in humans. This may stem in part from poor experimental design and conduct of animal experiments. Despite widespread recognition of these problems and implementation of guidelines to attenuate them, a review of the literature suggests that experimental design and conduct of laboratory animal research are still in need of refinement. This paper will review and discuss possible sources of biases, highlight advantages and limitations of strategies proposed to alleviate them, and provide a conceptual framework for improving the reproducibility of laboratory animal research.
Resumo:
Humans possess a highly developed sensitivity for facial features. This sensitivity is also deployed to non-human beings and inanimate objects such as cars. In the present study we aimed to investigate whether car design has a bearing on the behaviour of pedestrians. Methods: An immersive virtual reality environment with a zebra crossing was used to determine a) whether the minimum accepted distance for crossing the street is bigger for cars with dominant appearance than for cars with friendly appearance (Block 1) and b) whether the speed of dominant cars are overestimated compared to friendly cars (Block 2). In Block 1, the participant's task was to cross the road in front of an approaching car at the latest moment. The point of time when entering and leaving the street was measured. In Block 2 they were asked to estimate the speed of each passing car. An independent sample rated dominant cars as being more dominant, angry and hostile than friendly cars. Results: None of the predictions regarding the car design was confirmed. Instead, there was an effect of starting position: From the centre island, participants entered the road significantly later (smaller accepted distance) and left the road later than when starting from the pavement. Consistently, the speed of the cars was estimated significantly lower when standing on the centre island compared to the pavement. When entering the visual size of the cars as factor (instead of dominance), we found that participants started to cross the road significantly later in front of small cars compared to big cars and that the speed of smaller cars was overestimated compared to big cars (size-speed bias). Conclusions: Car size and starting position, not car design seem to have an influence on road crossing behaviour.