62 resultados para Design and Geometry
Resumo:
The Liquid Argon Time Projection Chamber (LArTPC) is a prime type of detector for future large-mass neutrino observatories and proton decay searches. In this paper we present the design and operation, as well as experimental results from ARGONTUBE, a LArTPC being operated at the AEC-LHEP, University of Bern. The main goal of this detector is to prove the feasibility of charge drift over very long distances in liquid argon. Many other aspects of the LArTPC technology are also investigated, such as a voltage multiplier to generate high voltage in liquid argon (Greinacher circuit), a cryogenic purification system and the application of multi-photon ionization of liquid argon by a UV laser. For the first time, tracks induced by cosmic muons and UVlaser beam pulses have been observed and studied at drift distances of up to 5 m, the longest reached to date.
Resumo:
Most medical implants run on batteries, which require costly and tedious replacement or recharging. It is believed that micro-generators utilizing intracorporeal energy could solve these problems. However, such generators do not, at this time, meet the energy requirements of medical implants.This paper highlights some essential aspects of designing and implementing a power source that scavenges energy from arterial expansion and contraction to operate an implanted medical device. After evaluating various potentially viable transduction mechanisms, the fabricated prototype employs an electromagnetic transduction mechanism. The artery is inserted into a laboratory-fabricated flexible coil which is permitted to freely deform in a magnetic field. This work also investigates the effects of the arterial wall's material properties on energy harvesting potential. For that purpose, two types of arteries (Penrose X-ray tube, which behave elastically, and an artery of a Göttinger minipig, which behaves viscoelastically) were tested. No noticeable difference could be observed between these two cases. For the pig artery, average harvestable power was 42 nW. Moreover, peak power was 2.38 μW. Both values are higher than those of the current state of the art (6 nW/16 nW). A theoretical modelling of the prototype was developed and compared to the experimental results.
Resumo:
This paper presents the first analysis of the input impedance and radiation properties of a dipole antenna, placed on top of Fan 's three-dimensional electromagnetic bandgap (EBG) structure, (Applied Physics Letters, 1994) constructed using a high dielectric constant ceramic. The best position of the dipole on the EBG surface is determined following impedance and radiation pattern analyses. Based on this optimum configuration an integrated Schottky heterodyne detector was designed, manufactured and tested from 0.48 to 0.52 THz. The main antenna features were not degraded by the high dielectric constant substrate due to the use of the EBG approach. Measured radiation patterns are in good agreement with the predicted ones.
Resumo:
OBJECTIVE The cost-effectiveness of cast nonprecious frameworks has increased their prevalence in cemented implant crowns. The purpose of this study was to assess the effect of the design and height of the retentive component of a standard titanium implant abutment on the fit, possible horizontal rotation and retention forces of cast nonprecious alloy crowns prior to cementation. MATERIALS AND METHODS Two abutment designs were examined: Type A with a 6° taper and 8 antirotation planes (Straumann Tissue-Level RN) and Type B with a 7.5° taper and 1 antirotation plane (SICace implant). Both types were analyzed using 60 crowns: 20 with a full abutment height (6 mm), 20 with a medium abutment height (4 mm), and 20 with a minimal (2.5 mm) abutment height. The marginal and internal fit and the degree of possible rotation were evaluated by using polyvinylsiloxane impressions under a light microscope (magnification of ×50). To measure the retention force, a custom force-measuring device was employed. STATISTICAL ANALYSIS one-sided Wilcoxon rank-sum tests with Bonferroni-Holm corrections, Fisher's exact tests, and Spearman's rank correlation coefficient. RESULTS Type A exhibited increased marginal gaps (primary end-point: 55 ± 20 μm vs. 138 ± 59 μm, P < 0.001) but less rotation (P < 0.001) than Type B. The internal fit was also better for Type A than for Type B (P < 0.001). The retention force of Type A (2.49 ± 3.2 N) was higher (P = 0.019) than that of Type B (1.27 ± 0.84 N). Reduction in abutment height did not affect the variables observed. CONCLUSION Less-tapered abutments with more antirotation planes provide an increase in the retention force, which confines the horizontal rotation but widens the marginal gaps of the crowns. Thus, casting of nonprecious crowns with Type A abutments may result in clinically unfavorable marginal gaps.
Resumo:
In order to harness the unique properties of nanoparticles for novel clinical applications and to modulate their uptake into specific immune cells we designed a new library of homo- and hetero-functional fluorescence-encoded gold nanoparticles (Au-NPs) using different poly(vinyl alcohol) and poly(ethylene glycol)-based polymers for particle coating and stabilization. The encoded particles were fully characterized by UV-Vis and fluorescence spectroscopy, zeta potential and dynamic light scattering. The uptake by human monocyte derived dendritic cells in vitro was studied by confocal laser scanning microscopy and quantified by fluorescence-activated cell sorting and inductively coupled plasma atomic emission spectroscopy. We show how the chemical modification of particle surfaces, for instance by attaching fluorescent dyes, can conceal fundamental particle properties and modulate cellular uptake. In order to mask the influence of fluorescent dyes on cellular uptake while still exploiting its fluorescence for detection, we have created hetero-functionalized Au-NPs, which again show typical particle dependent cellular interactions. Our study clearly prove that the thorough characterization of nanoparticles at each modification step in the engineering process is absolutely essential and that it can be necessary to make substantial adjustments of the particles in order to obtain reliable cellular uptake data, which truly reflects particle properties.
Resumo:
OBJECTIVE A number of factors limit the effectiveness of current aortic arch studies in assessing optimal neuroprotection strategies, including insufficient patient numbers, heterogenous definitions of clinical variables, multiple technical strategies, inadequate reporting of surgical outcomes and a lack of collaborative effort. We have formed an international coalition of centres to provide more robust investigations into this topic. METHODS High-volume aortic arch centres were identified from the literature and contacted for recruitment. A Research Steering Committee of expert arch surgeons was convened to oversee the direction of the research. RESULTS The International Aortic Arch Surgery Study Group has been formed by 41 arch surgeons from 10 countries to better evaluate patient outcomes after aortic arch surgery. Several projects, including the establishment of a multi-institutional retrospective database, randomized controlled trials and a prospectively collected database, are currently underway. CONCLUSIONS Such a collaborative effort will herald a turning point in the surgical management of aortic arch pathologies and will provide better powered analyses to assess the impact of varying surgical techniques on mortality and morbidity, identify predictors for neurological and operative risk, formulate and validate risk predictor models and review long-term survival outcomes and quality-of-life after arch surgery.
Resumo:
This thesis consists of four essays on the design and disclosure of compensation contracts. Essays 1, 2 and 3 focus on behavioral aspects of mandatory compensation disclosure rules and of contract negotiations in agency relationships. The three experimental studies develop psychology- based theory and present results that deviate from standard economic predictions. Furthermore, the results of Essay 1 and 2 also have implications for firms’ discretion in how to communicate their top management’s incentives to the capital market. Essay 4 analyzes the role of fairness perceptions for the evaluation of executive compensation. For this purpose, two surveys targeting representative eligible voters as well as investment professionals were conducted. Essay 1 investigates the role of the detailed ‘Compensation Discussion and Analysis’, which is part of the Security and Exchange Commission’s 2006 regulation, on investors’ evaluations of executive performance. Compensation disclosure complying with this regulation clarifies the relationship between realized reported compensation and the underlying performance measures and their target achievement levels. The experimental findings suggest that the salient presentation of executives’ incentives inherent in the ‘Compensation Discussion and Analysis’ makes investors’ performance evaluations less outcome dependent. Therefore, investors’ judgment and investment decisions might be less affected by noisy environmental factors that drive financial performance. The results also suggest that fairness perceptions of compensation contracts are essential for investors’ performance evaluations in that more transparent disclosure increases the perceived fairness of compensation and the performance evaluation of managers who are not responsible for a bad financial performance. These results have important practical implications as firms might choose to communicate their top management’s incentive compensation more transparently in order to benefit from less volatile expectations about their future performance. Similar to the first experiment, the experiment described in Essay 2 addresses the question of more transparent compensation disclosure. However, other than the first experiment, the second experiment does not analyze the effect of a more salient presentation of contract information but the informational effect of contract information itself. For this purpose, the experiment tests two conditions in which the assessment of the compensation contracts’ incentive compatibility, which determines executive effort, is either possible or not. On the one hand, the results suggest that the quality of investors’ expectations about executive effort is improved, but on the other hand investors might over-adjust their prior expectations about executive effort if being confronted with an unexpected financial performance and under-adjust if the financial performance confirms their prior expectations. Therefore, in the experiment, more transparent compensation disclosure does not lead to more correct overall judgments of executive effort and to even lower processing quality of outcome information. These results add to the literature on disclosure which predominantly advocates more transparency. The findings of the experiment however, identify decreased information processing quality as a relevant disclosure cost category. Firms might therefore carefully evaluate the additional costs and benefits of more transparent compensation disclosure. Together with the results from the experiment in Essay 1, the two experiments on compensation disclosure imply that firms should rather focus on their discretion how to present their compensation disclosure to benefit from investors’ improved fairness perceptions and their spill-over on performance evaluation. Essay 3 studies the behavioral effects of contextual factors in recruitment processes that do not affect the employer’s or the applicant’s bargaining power from a standard economic perspective. In particular, the experiment studies two common characteristics of recruitment processes: Pre-contractual competition among job applicants and job applicants’ non-binding effort announcements as they might be made during job interviews. Despite the standard economic irrelevance of these factors, the experiment develops theory regarding the behavioral effects on employees’ subsequent effort provision and the employers’ contract design choices. The experimental findings largely support the predictions. More specifically, the results suggest that firms can benefit from increased effort and, therefore, may generate higher profits. Further, firms may seize a larger share of the employment relationship’s profit by highlighting the competitive aspects of the recruitment process and by requiring applicants to make announcements about their future effort. Finally, Essay 4 studies the role of fairness perceptions for the public evaluation of executive compensation. Although economic criteria for the design of incentive compensation generally do not make restrictive recommendations with regard to the amount of compensation, fairness perceptions might be relevant from the perspective of firms and standard setters. This is because behavioral theory has identified fairness as an important determinant of individuals’ judgment and decisions. However, although fairness concerns about executive compensation are often stated in the popular media and even in the literature, evidence on the meaning of fairness in the context of executive compensation is scarce and ambiguous. In order to inform practitioners and standard setters whether fairness concerns are exclusive to non-professionals or relevant for investment professionals as well, the two surveys presented in Essay 4 aim to find commonalities in the opinions of representative eligible voters and investments professionals. The results suggest that fairness is an important criterion for both groups. Especially, exposure to risk in the form of the variable compensation share is an important criterion shared by both groups. The higher the assumed variable share, the higher is the compensation amount to be perceived as fair. However, to a large extent, opinions on executive compensation depend on personality characteristics, and to some extent, investment professionals’ perceptions deviate systematically from those of non-professionals. The findings imply that firms might benefit from emphasizing the riskiness of their managers’ variable pay components and, therefore, the findings are also in line with those of Essay 1.
Resumo:
INTRODUCTION Even though arthroplasty of the ankle joint is considered to be an established procedure, only about 1,300 endoprostheses are implanted in Germany annually. Arthrodeses of the ankle joint are performed almost three times more often. This may be due to the availability of the procedure - more than twice as many providers perform arthrodesis - as well as the postulated high frequency of revision procedures of arthroplasties in the literature. In those publications, however, there is often no clear differentiation between revision surgery with exchange of components, subsequent interventions due to complications and subsequent surgery not associated with complications. The German Orthopaedic Foot and Ankle Association's (D. A. F.) registry for total ankle replacement collects data pertaining to perioperative complications as well as cause, nature and extent of the subsequent interventions, and postoperative patient satisfaction. MATERIAL AND METHODS The D. A. F.'s total ankle replacement register is a nation-wide, voluntary registry. After giving written informed consent, the patients can be added to the database by participating providers. Data are collected during hospital stay for surgical treatment, during routine follow-up inspections and in the context of revision surgery. The information can be submitted in paper-based or online formats. The survey instruments are available as minimum data sets or scientific questionnaires which include patient-reported outcome measures (PROMs). The pseudonymous clinical data are collected and evaluated at the Institute for Evaluative Research in Medicine, University of Bern/Switzerland (IEFM). The patient-related data remain on the register's module server in North Rhine-Westphalia, Germany. The registry's methodology as well as the results of the revisions and patient satisfaction for 115 patients with a two year follow-up period are presented. Statistical analyses are performed with SAS™ (Version 9.4, SAS Institute, Inc., Cary, NC, USA). RESULTS About 2½ years after the register was launched there are 621 datasets on primary implantations, 1,427 on follow-ups and 121 records on re-operation available. 49 % of the patients received their implants due to post-traumatic osteoarthritis, 27 % because of a primary osteoarthritis and 15 % of patients suffered from a rheumatic disease. More than 90 % of the primary interventions proceeded without complications. Subsequent interventions were recorded for 84 patients, which corresponds to a rate of 13.5 % with respect to the primary implantations. It should be noted that these secondary procedures also include two-stage procedures not due to a complication. "True revisions" are interventions with exchange of components due to mechanical complications and/or infection and were present in 7.6 % of patients. 415 of the patients commented on their satisfaction with the operative result during the last follow-up: 89.9 % of patients evaluate their outcome as excellent or good, 9.4 % as moderate and only 0.7 % (3 patients) as poor. In these three cases a component loosening or symptomatic USG osteoarthritis was present. Two-year follow-up data using the American Orthopedic Foot and Ankle Society Ankle and Hindfoot Scale (AOFAS-AHS) are already available for 115 patients. The median AOFAS-AHS score increased from 33 points preoperatively to more than 80 points three to six months postoperatively. This increase remained nearly constant over the entire two-year follow-up period. CONCLUSION Covering less than 10 % of the approximately 240 providers in Germany and approximately 12 % of the annually implanted total ankle-replacements, the D. A. F.-register is still far from being seen as a national registry. Nevertheless, geographical coverage and inclusion of "high-" (more than 100 total ankle replacements a year) and "low-volume surgeons" (less than 5 total ankle replacements a year) make the register representative for Germany. The registry data show that the number of subsequent interventions and in particular the "true revision" procedures are markedly lower than the 20 % often postulated in the literature. In addition, a high level of patient satisfaction over the short and medium term is recorded. From the perspective of the authors, these results indicate that total ankle arthroplasty - given a correct indication and appropriate selection of patients - is not inferior to an ankle arthrodesis concerning patients' satisfaction and function. First valid survival rates can be expected about 10 years after the register's start.