37 resultados para Data Generation


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To determine if adequacy of randomisation and allocation concealment is associated with changes in effect sizes (ES) when comparing physical therapy (PT) trials with and without these methodological characteristics. DESIGN Meta-epidemiological study. PARTICIPANTS A random sample of randomised controlled trials (RCTs) included in meta-analyses in the PT discipline were identified. INTERVENTION Data extraction including assessments of random sequence generation and allocation concealment was conducted independently by two reviewers. To determine the association between sequence generation, and allocation concealment and ES, a two-level analysis was conducted using a meta-meta-analytic approach. PRIMARY AND SECONDARY OUTCOME MEASURES association between random sequence generation and allocation concealment and ES in PT trials. RESULTS 393 trials included in 43 meta-analyses, analysing 44 622 patients contributed to this study. Adequate random sequence generation and appropriate allocation concealment were accomplished in only 39.7% and 11.5% of PT trials, respectively. Although trials with inappropriate allocation concealment tended to have an overestimate treatment effect when compared with trials with adequate concealment of allocation, the difference was non-statistically significant (ES=0.12; 95% CI -0.06 to 0.30). When pooling our results with those of Nuesch et al, we obtained a pooled statistically significant value (ES=0.14; 95% CI 0.02 to 0.26). There was no difference in ES in trials with appropriate or inappropriate random sequence generation (ES=0.02; 95% CI -0.12 to 0.15). CONCLUSIONS Our results suggest that when evaluating risk of bias of primary RCTs in PT area, systematic reviewers and clinicians implementing research into practice should pay attention to these biases since they could exaggerate treatment effects. Systematic reviewers should perform sensitivity analysis including trials with low risk of bias in these domains as primary analysis and/or in combination with less restrictive analyses. Authors and editors should make sure that allocation concealment and random sequence generation are properly reported in trial reports.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES The purpose of this study was to compare the 2-year safety and effectiveness of new- versus early-generation drug-eluting stents (DES) according to the severity of coronary artery disease (CAD) as assessed by the SYNTAX (Synergy between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery) score. BACKGROUND New-generation DES are considered the standard-of-care in patients with CAD undergoing percutaneous coronary intervention. However, there are few data investigating the effects of new- over early-generation DES according to the anatomic complexity of CAD. METHODS Patient-level data from 4 contemporary, all-comers trials were pooled. The primary device-oriented clinical endpoint was the composite of cardiac death, myocardial infarction, or ischemia-driven target-lesion revascularization (TLR). The principal effectiveness and safety endpoints were TLR and definite stent thrombosis (ST), respectively. Adjusted hazard ratios (HRs) with 95% confidence intervals (CIs) were calculated at 2 years for overall comparisons, as well as stratified for patients with lower (SYNTAX score ≤11) and higher complexity (SYNTAX score >11). RESULTS A total of 6,081 patients were included in the study. New-generation DES (n = 4,554) compared with early-generation DES (n = 1,527) reduced the primary endpoint (HR: 0.75 [95% CI: 0.63 to 0.89]; p = 0.001) without interaction (p = 0.219) between patients with lower (HR: 0.86 [95% CI: 0.64 to 1.16]; p = 0.322) versus higher CAD complexity (HR: 0.68 [95% CI: 0.54 to 0.85]; p = 0.001). In patients with SYNTAX score >11, new-generation DES significantly reduced TLR (HR: 0.36 [95% CI: 0.26 to 0.51]; p < 0.001) and definite ST (HR: 0.28 [95% CI: 0.15 to 0.55]; p < 0.001) to a greater extent than in the low-complexity group (TLR pint = 0.059; ST pint = 0.013). New-generation DES decreased the risk of cardiac mortality in patients with SYNTAX score >11 (HR: 0.45 [95% CI: 0.27 to 0.76]; p = 0.003) but not in patients with SYNTAX score ≤11 (pint = 0.042). CONCLUSIONS New-generation DES improve clinical outcomes compared with early-generation DES, with a greater safety and effectiveness in patients with SYNTAX score >11.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES The SOURCE XT Registry (Edwards SAPIEN XT Aortic Bioprosthesis Multi-Region Outcome Registry) assessed the use and clinical outcomes with the SAPIEN XT (Edwards Lifesciences, Irvine, California) valve in the real-world setting. BACKGROUND Transcatheter aortic valve replacement is an established treatment for high-risk/inoperable patients with severe aortic stenosis. The SAPIEN XT is a balloon-expandable valve with enhanced features allowing delivery via a lower profile sheath. METHODS The SOURCE XT Registry is a prospective, multicenter, post-approval study. Data from 2,688 patients at 99 sites were analyzed. The main outcome measures were all-cause mortality, stroke, major vascular complications, bleeding, and pacemaker implantations at 30-days and 1 year post-procedure. RESULTS The mean age was 81.4 ± 6.6 years, 42.3% were male, and the mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was 20.4 ± 12.4%. Patients had a high burden of coronary disease (44.2%), diabetes (29.4%), renal insufficiency (28.9%), atrial fibrillation (25.6%), and peripheral vascular disease (21.2%). Survival was 93.7% at 30 days and 80.6% at 1 year. At 30-day follow-up, the stroke rate was 3.6%, the rate of major vascular complications was 6.5%, the rate of life-threatening bleeding was 5.5%, the rate of new pacemakers was 9.5%, and the rate of moderate/severe paravalvular leak was 5.5%. Multivariable analysis identified nontransfemoral approach (hazard ratio [HR]: 1.84; p < 0.0001), renal insufficiency (HR: 1.53; p < 0.0001), liver disease (HR: 1.67; p = 0.0453), moderate/severe tricuspid regurgitation (HR: 1.47; p = 0.0019), porcelain aorta (HR: 1.47; p = 0.0352), and atrial fibrillation (HR: 1.41; p = 0.0014), with the highest HRs for 1-year mortality. Major vascular complications and major/life-threatening bleeding were the most frequently seen complications associated with a significant increase in 1-year mortality. CONCLUSIONS The SOURCE XT Registry demonstrated appropriate use of the SAPIEN XT THV in the first year post-commercialization in Europe. The safety profile is sustained, and clinical benefits have been established in the real-world setting. (SOURCE XT Registry; NCT01238497).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND An increased body mass index (BMI) is associated with a high risk of cardiovascular disease and reduction in life expectancy. However, several studies reported improved clinical outcomes in obese patients treated for cardiovascular diseases. The aim of the present study is to investigate the impact of BMI on long-term clinical outcomes after implantation of zotarolimus eluting stents. METHODS Individual patient data were pooled from the RESOLUTE Clinical Program comprising five trials worldwide. The study population was sorted according to BMI tertiles and clinical outcomes were evaluated at 2-year follow-up. RESULTS Data from a total of 5,127 patients receiving the R-ZES were included in the present study. BMI tertiles were as follow: I tertile (≤ 25.95 kg/m(2) -Low or normal weight) 1,727 patients; II tertile (>25.95 ≤ 29.74 kg/m(2) -overweight) 1,695 patients, and III tertile (>29.74 kg/m(2) -obese) 1,705 patients. At 2-years follow-up no difference was found for patients with high BMI (III tertile) compared with patients with normal or low BMI (I tertile) in terms of target lesion failure (I-III tertile, HR [95% CI] = 0.89 [0.69, 1.14], P = 0.341; major adverse cardiac events (I-III tertile, HR [95% CI] = 0.90 [0.72, 1.14], P = 0.389; cardiac death (I-III tertile, HR [95% CI] = 1.20 [0.73, 1.99], P = 0.476); myocardial infarction (I-III tertile, HR [95% CI] = 0.86 [0.55, 1.35], P = 0.509; clinically-driven target lesion revascularization (I-III tertile, HR [95% CI] = 0.75 [0.53, 1.08], P = 0.123; definite or probable stent thrombosis (I-III tertile, HR [95% CI] = 0.98 [0.49, 1.99], P = 0.964. CONCLUSIONS In the present study, the patients' body mass index was found to have no impact on long-term clinical outcomes after coronary artery interventions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND The safety and efficacy of new-generation drug-eluting stents (DES) in women with multiple atherothrombotic risk (ATR) factors is unclear. METHODS AND RESULTS We pooled patient-level data for women enrolled in 26 randomized trials. Study population was categorized based on the presence or absence of high ATR, which was defined as having history of diabetes mellitus, prior percutaneous or surgical coronary revascularization, or prior myocardial infarction. The primary end point was major adverse cardiovascular events defined as a composite of all-cause mortality, myocardial infarction, or target lesion revascularization at 3 years of follow-up. Out of 10 449 women included in the pooled database, 5333 (51%) were at high ATR. Compared with women not at high ATR, those at high ATR had significantly higher risk of major adverse cardiovascular events (15.8% versus 10.6%; adjusted hazard ratio: 1.53; 95% confidence interval: 1.34-1.75; P=0.006) and all-cause mortality. In high-ATR risk women, the use of new-generation DES was associated with significantly lower risk of 3-year major adverse cardiovascular events (adjusted hazard ratio: 0.69; 95% confidence interval: 0.52-0.92) compared with early-generation DES. The benefit of new-generation DES on major adverse cardiovascular events was uniform between high-ATR and non-high-ATR women, without evidence of interaction (Pinteraction=0.14). At landmark analysis, in high-ATR women, stent thrombosis rates were comparable between DES generations in the first year, whereas between 1 and 3 years, stent thrombosis risk was lower with new-generation devices. CONCLUSIONS Use of new-generation DES even in women at high ATR is associated with a benefit consistent over 3 years of follow-up and a substantial improvement in very-late thrombotic safety.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND In percutaneous coronary intervention (PCI) patients new-generation drug-eluting stent (DES) has reduced adverse events in comparison to early-generation DES. The aim of the current study was to investigate the long-term clinical efficacy and safety of new-generation DES versus early-generation DES for PCI of unprotected left main coronary artery (uLMCA) disease. METHODS The patient-level data from the ISAR-LEFT MAIN and ISAR-LEFT MAIN 2 randomized trials were pooled. The clinical outcomes of PCI patients assigned to new-generation DES (everolimus- or zotarolimus-eluting stent) versus early-generation DES (paclitaxel- or sirolimus-eluting stent) were studied. The primary endpoint was the composite of death, myocardial infarction (MI), target lesion revascularization and stroke (MACCE, major adverse cardiac and cerebrovascular event). RESULTS In total, 1257 patients were available. At 3 years, the risk of MACCE was comparable between patients assigned to new-generation DES or early-generation DES (28.2 versus 27.5 %, hazard ratio-HR 1.03, 95 % confidence intervals-CI 0.83-1.26; P = 0.86). Definite/probable stent thrombosis was low and comparable between new-generation DES and early-generation DES (0.8 versus 1.6 %, HR 0.52, 95 % CI 0.18-1.57; P = 0.25); in patients treated with new-generation DES no cases occurred beyond 30 days. Diabetes increased the risk of MACCE in patients treated with new-generation DES but not with early-generation DES (P interaction = 0.004). CONCLUSIONS At 3-year follow-up, a PCI with new-generation DES for uLMCA disease shows comparable efficacy to early-generation DES. Rates of stent thrombosis were low in both groups. Diabetes significantly impacts the risk of MACCE at 3 years in patients treated with new-generation DES for uLMCA disease. ClinicalTrials.gov Identifiers: NCT00133237; NCT00598637.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We analyse the access to different institutional pathways to higher education for second-generation students, focusing on youths that hold a higher-education entrance certificate. The alternative vocational pathway appears to compensate to some degree, compared to the traditional academic one, for North-African and Southern-European youths in France, those from Turkey in Germany, and to a lesser degree those from Portugal, Turkey, Ex-Yugoslavia, Albania/Kosovo in Switzerland. This is not the case in Switzerland for Western-European, Italian, and Spanish youths who indeed access higher education via the academic pathway more often than Swiss youths. Using youth panel and survey data, multinomial models are applied to analyse these pathway choices.