52 resultados para Constant amplitude


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to characterize the nociceptive withdrawal reflex (NWR) and to define the nociceptive threshold in 25 healthy, non-medicated experimental sheep in standing posture. Electrical stimulation of the dorsal lateral digital nerves of the right thoracic and the pelvic limb was performed and surface-electromyography (EMG) from the deltoid (all animals) and the femoral biceps (18 animals) or the peroneus tertius muscles (7 animals) was recorded. The behavioural reaction following each stimulation was scored on a scale from 0 (no reaction) to 5 (strong whole body reaction). A train-of-five 1 ms constant-current pulse was used and current intensity was stepwise increased until NWR threshold intensity was reached. The NWR threshold intensity (It) was defined as the minimal stimulus intensity able to evoke a reflex with a minimal Root-Mean-Square amplitude (RMSA) of 20 μV, a minimal duration of 10 ms and a minimal reaction score of 1 (slight muscle contraction of the stimulated limb) within the time window of 20 to 130 ms post-stimulation. Based on this value, further stimulations were performed below (0.9It) and above threshold (1.5It and 2It). The stimulus-response curve was described. Data are reported as medians and interquartile ranges. At the deltoid muscle It was 4.4 mA (2.9–5.7) with an RMSA of 62 μV (30–102). At the biceps femoris muscle It was 7.0 mA (4.0–10.0) with an RMSA of 43 μV (34–50) and at the peroneus tertius muscle It was 3.4 mA (3.1–4.4) with an RMSA of 38 μV (32–46). Above threshold, RMSA was significantly increased at all muscles. Below threshold, RMSA was only significantly smaller than at It for the peroneus tertius muscle but not for the other muscles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical importance of pulsatility is a recurring topic of debate in mechanical circulatory support. Lack of pulsatility has been identified as a possible factor responsible for adverse events and has also demonstrated a role in myocardial perfusion and cardiac recovery. A commonly used method for restoring pulsatility with rotodynamic blood pumps (RBPs) is to modulate the speed profile, synchronized to the cardiac cycle. This introduces additional parameters that influence the (un)loading of the heart, including the timing (phase shift) between the native cardiac cycle and the pump pulses, and the amplitude of speed modulation. In this study, the impact of these parameters upon the heart-RBP interaction was examined in terms of the pressure head-flow (HQ) diagram. The measurements were conducted using a rotodynamic Deltastream DP2 pump in a validated hybrid mock circulation with baroreflex function. The pump was operated with a sinusoidal speed profile, synchronized to the native cardiac cycle. The simulated ventriculo-aortic cannulation showed that the level of (un)loading and the shape of the HQ loops strongly depend on the phase shift. The HQ loops displayed characteristic shapes depending on the phase shift. Increased contribution of native contraction (increased ventricular stroke work [WS ]) resulted in a broadening of the loops. It was found that the previously described linear relationship between WS and the area of the HQ loop for constant pump speeds becomes a family of linear relationships, whose slope depends on the phase shift.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate a class of optimal control problems that exhibit constant exogenously given delays in the control in the equation of motion of the differential states. Therefore, we formulate an exemplary optimal control problem with one stock and one control variable and review some analytic properties of an optimal solution. However, analytical considerations are quite limited in case of delayed optimal control problems. In order to overcome these limits, we reformulate the problem and apply direct numerical methods to calculate approximate solutions that give a better understanding of this class of optimization problems. In particular, we present two possibilities to reformulate the delayed optimal control problem into an instantaneous optimal control problem and show how these can be solved numerically with a stateof- the-art direct method by applying Bock’s direct multiple shooting algorithm. We further demonstrate the strength of our approach by two economic examples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the first analysis of the input impedance and radiation properties of a dipole antenna, placed on top of Fan 's three-dimensional electromagnetic bandgap (EBG) structure, (Applied Physics Letters, 1994) constructed using a high dielectric constant ceramic. The best position of the dipole on the EBG surface is determined following impedance and radiation pattern analyses. Based on this optimum configuration an integrated Schottky heterodyne detector was designed, manufactured and tested from 0.48 to 0.52 THz. The main antenna features were not degraded by the high dielectric constant substrate due to the use of the EBG approach. Measured radiation patterns are in good agreement with the predicted ones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract. In this paper, we compare the diurnal variations in middle-atmospheric water vapor as measured by two ground-based microwave radiometers in the Alpine region near Bern, Switzerland. The observational data set is also compared to data from the chemistry–climate model WACCM. Due to the small diurnal variations of usually less than 1%, averages over extended time periods are required. Therefore, two time periods of five months each, December to April and June to October, were taken for the comparison. The diurnal variations from the observational data agree well with each other in amplitude and phase. The linear correlation coefficients range from 0.8 in the upper stratosphere to 0.5 in the upper mesosphere. The observed diurnal variability is significant at all pressure levels within the sensitivity of the instruments. Comparing our observations with WACCM, we find that the agreement of the phase of the diurnal cycle between observations and model is better from December to April than from June to October. The amplitudes of the diurnal variations for both time periods increase with altitude in WACCM, but remain approximately constant at 0.05 ppm in the observations. The WACCM data are used to separate the processes that lead to diurnal variations in middle-atmospheric water vapor above Bern. The dominating processes were found to be meridional advection below 0.1 hPa, vertical advection between 0.1 and 0.02 hPa and (photo-)chemistry above 0.02 hPa. The contribution of zonal advection is small. The highest diurnal variations in water vapor as seen in the WACCM data are found in the mesopause region during the time period from June to October with diurnal amplitudes of 0.2 ppm (approximately 5% in relative units).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dexmedetomidine and lignocaine IV are used clinically to provide analgesia in horses. The aims of this study were to investigate the antinociceptive effects, plasma concentrations and sedative effects of 2, 4 and 6 µg/kg/h dexmedetomidine IV, with a bolus of 0.96 µg/kg preceding each continuous rate infusion (CRI), and 20, 40 and 60 µg/kg/min lignocaine IV, with a bolus of 550 µg/kg preceding each CRI, in 10 Swiss Warmblood horses. Electrically elicited nociceptive withdrawal reflexes were evaluated by deltoid muscle electromyography. Nociceptive threshold and tolerance were determined by electromyography and behaviour following single and repeated stimulation. Plasma concentrations of drugs were determined by liquid chromatography and mass spectrometry. Sedation was scored on a visual analogue scale. Dexmedetomidine increased nociceptive threshold to single and repeated stimulation for all CRIs, except at 2 µg/kg/h, where no increase in single stimulation nociceptive threshold was observed. Dexmedetomidine increased nociceptive tolerance to single and repeated stimulation at all CRIs. There was large individual variability in dexmedetomidine plasma concentrations and levels of sedation; the median plasma concentration providing antinociceptive effects to all recorded parameters was 0.15 ng/mL, with a range from <0.02 ng/mL (below the lower limit of quantification) to 0.25 ng/mL. Lignocaine increased nociceptive threshold and tolerance to single and repeated stimulation at CRIs of 40 and 60 µg/kg/min, corresponding to plasma lignocaine concentrations >600 ng/mL. Only nociceptive tolerance to repeated stimulation increased at 20 µg/kg/min lignocaine. Lignocaine at 40 µg/kg/min and dexmedetomidine at 4 µg/kg/h were the lowest CRIs resulting in consistent antinociception. Lignocaine did not induce significant sedation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dexmedetomidine, the most selective α2 -adrenoceptor agonist in clinical use, is increasingly being used in both conscious and anaesthetized horses; however, the pharmacokinetics and sedative effects of this drug administered alone as an infusion are not previously described in horses. Seven horses received an infusion of 8 μg dexmedetomidine/kg/h for 150 min, venous blood samples were collected, and dexmedetomidine concentrations were assayed using liquid chromatography-mass spectrometry (LC/MS) and analyzed using noncompartmental pharmacokinetic analysis. Sedation was scored as the distance from the lower lip of the horse to the ground measured in centimetre. The harmonic mean (SD) plasma elimination half-life (Lambda z half-life) for dexmedetomidine was 20.9 (5.1) min, clearance (Cl) was 0.3 (0.20) L/min/kg, and volume of distribution at steady-state (Vdss ) was 13.7 (7.9) L/kg. There was a considerable individual variation in the concentration of dexmedetomidine vs. time profile. The level of sedation covaried with the plasma concentration of dexmedetomidine. This implies that for clinical use of dexmedetomidine constant rate infusion in conscious horses, infusion rates can be easily adjusted to effect, and this is preferable to an infusion at a predetermined value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bei EKP-Experimenten ist oft nicht von vornherein klar, in welchen Zeitfenstern Effekte erwartet werden. Daher müssen Analysen die Daten über mehrere Zeitfenster hinweg explorieren. Darüber hinaus sind statistische Analysen, die alle Elektroden berücksichtigen, wünschenswert, aber nicht trivial. Zur Lösung dieser Probleme präsentieren wir hier das Programm Ragu (Randomization Graphical User interface), das spezifisch für die statistische Auswertung von Mehrkanal EEG-Experimenten eingesetzt werden kann. Ragu soll Wissenschaftlern die Möglichkeit geben, die Signifikanzen von EKP-Effekten global zu untersuchen, ohne die Notwendigkeit von A-Priori-Annahmen. Das Programm basiert auf der Messung von Feldstärke-Differenzen unter Berücksichtigung aller Elektroden. Im ersten Teil dieses Workshops werden wir die Notwendigkeit von topografischen ERP-Analysen angesichts des Volumenleitungsproblems herausarbeiten und Vergleiche zu Einzelelektroden-Ansätzen anstellen. Wir werden an Hand unserer frei erhältlichen in-house Software Ragu das Prinzip von Randomisierungsstatistiken erklären und deren unterschiedliche Anwendungsmöglichkeiten für ERP-Analysen. In einem zweiten Teil haben die Teilnehmenden die Gelegenheit, Ragu an einem Beispielsatz auszuprobieren und Möglichkeiten der Anwendung von Ragu in ihrer eigenen Forschungs zu besprechen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The gas-phase rotational motion of hexafluorobenzene has been measured in real time using femtosecond (fs) time-resolved rotational Raman coherence spectroscopy (RR-RCS) at T = 100 and 295 K. This four-wave mixing method allows to probe the rotation of non-polar gas-phase molecules with fs time resolution over times up to ∼5 ns. The ground state rotational constant of hexafluorobenzene is determined as B 0 = 1029.740(28) MHz (2σ uncertainty) from RR-RCS transients measured in a pulsed seeded supersonic jet, where essentially only the v = 0 state is populated. Using this B 0 value, RR-RCS measurements in a room temperature gas cell give the rotational constants B v of the five lowest-lying thermally populated vibrationally excited states ν7/8, ν9, ν11/12, ν13, and ν14/15. Their B v constants differ from B 0 by between −1.02 MHz and +2.23 MHz. Combining the B 0 with the results of all-electron coupled-cluster CCSD(T) calculations of Demaison et al. [Mol. Phys.111, 1539 (2013)] and of our own allow to determine the C-C and C-F semi-experimental equilibrium bond lengths r e(C-C) = 1.3866(3) Å and r e(C-F) = 1.3244(4) Å. These agree with the CCSD(T)/wCVQZ r e bond lengths calculated by Demaison et al. within ±0.0005 Å. We also calculate the semi-experimental thermally averaged bond lengths r g(C-C)=1.3907(3) Å and r g(C-F)=1.3250(4) Å. These are at least ten times more accurate than two sets of experimental gas-phase electron diffraction r g bond lengths measured in the 1960s.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE The aim of the present study was to evaluate a dose reduction in contrast-enhanced chest computed tomography (CT) by comparing the three latest generations of Siemens CT scanners used in clinical practice. We analyzed the amount of radiation used with filtered back projection (FBP) and an iterative reconstruction (IR) algorithm to yield the same image quality. Furthermore, the influence on the radiation dose of the most recent integrated circuit detector (ICD; Stellar detector, Siemens Healthcare, Erlangen, Germany) was investigated. MATERIALS AND METHODS 136 Patients were included. Scan parameters were set to a thorax routine: SOMATOM Sensation 64 (FBP), SOMATOM Definition Flash (IR), and SOMATOM Definition Edge (ICD and IR). Tube current was set constantly to the reference level of 100 mA automated tube current modulation using reference milliamperes. Care kV was used on the Flash and Edge scanner, while tube potential was individually selected between 100 and 140 kVp by the medical technologists at the SOMATOM Sensation. Quality assessment was performed on soft-tissue kernel reconstruction. Dose was represented by the dose length product. RESULTS Dose-length product (DLP) with FBP for the average chest CT was 308 mGy*cm ± 99.6. In contrast, the DLP for the chest CT with IR algorithm was 196.8 mGy*cm ± 68.8 (P = 0.0001). Further decline in dose can be noted with IR and the ICD: DLP: 166.4 mGy*cm ± 54.5 (P = 0.033). The dose reduction compared to FBP was 36.1% with IR and 45.6% with IR/ICD. Signal-to-noise ratio (SNR) was favorable in the aorta, bone, and soft tissue for IR/ICD in combination compared to FBP (the P values ranged from 0.003 to 0.048). Overall contrast-to-noise ratio (CNR) improved with declining DLP. CONCLUSION The most recent technical developments, namely IR in combination with integrated circuit detectors, can significantly lower radiation dose in chest CT examinations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work investigates the subcritical spatial transition in the swept Hiemenz boundary layer by means of direct numerical simulations (DNS). A pair of steady co-rotating vortices located at the attachment line is enforced as a primary disturbance leading to streaks which are stable. A small secondary, time-dependent disturbance interacts with these streaks such that instability and breakdown to turbulence may occur. The instability only occurs for a certain band of secondary disturbance frequencies. Positive secondary instability growth rates could be observed for Reynolds numbers as low as , whereas the linear critical Reynolds number is. Uniform wall suction is shown to stabilise this transition mechanism, analogously to results from linear stability theory. The effects of suction on the formation of primary streaks and on the secondary growth rate are decoupled. For streaks of different suction whose amplitude is held constant by adjusting the Reynolds number, the suction is shown to increase the growth rate of the secondary instability. The stabilising influence of wall suction consists in decreasing the streak amplitude only. Depending on the Reynolds number and the suction strength, breakdown may either occur locally and may be convected along the far-field streamlines, or occur globally and cover broad regions in the downstream direction.